Solar Irradiance Monitoring in Solar Energy Projects

Similar documents
Pyranometers. for the Accurate Measurement of Solar Irradiance

Make the most of the sun

Newsletter 21 ACCIONA s Palma del Río I & II CSP Plants

Newsletter 21 ACCIONA s Palma del Río I & II CSP Plants

Solar-Tech innovations inspired by rice fields. Content April 2017

SOLAR PHOTOVOLTAICS Part 1

Solar Project Yield Assessment. Workshop on Solar Power Project Development, Sept 20-21, 2012

Newsletter 34. The Winterlight Greenhouse Real-world Yield Measurements of Solar Modules How a University Serves its Island Using the Sun to Cool Down

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

SUV-B. New Generation of UV Radiometers UVA, UVB and UVE. Vintage pyranometer in pursuit of South African solar energy

UV, PAR and POM Applications

Content October Global Solar Energy Market Expanding. Contact

Newsletter 41. RT1: affordably measure solar irradiation and panel temperature for rooftop PV installations

Concentrating Solar Systems Radiation Resources Measurements, Data, and Uncertainty

Reducing Solar Performance Uncertainty. Presented by: Gwendalyn Bender, Head of Solar Product Development

THE SOUTH AFRICAN REFIT: SOLAR RESOURCE ASSESSMENT OPTIONS FOR SOLAR DEVELOPERS

Newsletter37 Our Innovative New Development: RaZON+

Newsletter 41. RT1: affordably measure solar irradiation and panel temperature for rooftop PV installations

SOLAR ENERGY. Nicholas KWARIKUNDA Physics Department, UNAM

CHP 1. Pyrheliometer. Instruction Manual

Global Atmosphere Watch Activities in Thailand for

Solar PV Performance and New Technologies in Northern Latitude Regions

Content January A New Year has begun. Contact

Giant power plants in Morocco equipped with Kipp & Zonen

Simply follow the sun. up to Maximize the yields of solar power plants with solar tracking control

Solar power status and perspectives DESERTEC an update. Dr. Bernd Utz Head of the Project Desertec Initiative of the Renewable Energy Division

Newsletter 17. Barchan Dunes: Silent Travelers of the Desert LAS MkII: the Next Generation Scintillometer Moldova s Solar Monitoring Station

Using PVSYST for Grid-Connected Systems. PV design engineers, PV installers (with experience), PV project managers and teachers.

SOLAR ENGINEERING OF THERMAL PROCESSES

Enel is about to launch a global Call for startups to select innovative projects in the field of the Renewable Energies.

The promise of concentrators. JUNBA Symposium January 13 th, 2009 Steve Horne,CTO SolFocus inc.

SOLAR ENERGY ASSESSMENT REPORT. For 80.5 kwp. Meteorological Data Source NASA-SSE. Date 18 October, Name of Place Uttar Pradesh.

Newsletter 23 SUV5, the Smart Total UV Radiometer

CASE STUDY How Uzbekistan is Becoming a Solar Energy Powerhouse

DESIGN AND EXPERIMENT OF PARABOLIC TROUGH COLLECTOR WITH NORTH-SOUTH ORIENTATION

Newsletter 39 RaZON+ Fully Tested and Ready To Go

Design of a new concentrated photovoltaic system under UAE conditions

Improvement in Efficiency of Solar Panel

ACRYLITE. for Solar Applications

Basic of Bifacial. 1-1 What is Bifacial? 1-2 Terms related to Bifacial. Design guide for Bifacial

Quantifying Gains in Solar Project Value from Quality Satellite & Ground Data

Southwest Solar Technologies, Inc. ASSETS FOR COLLABORATION IN CONCENTRATING SOLAR Herb Hayden, CTO

FUNDAMENTALS OF SOLAR ENERGY

Photovoltaic. - it is the main energy source of the planet since its inception 4 billion years ago and another 4 billion years it will be

SOLAR RADIATION ESTIMATION UNDER CLEAR SKY CONDITIONS FOR BRAŞOV AREA (ROMANIA) LINKE TURBIDITY FACTOR

Solar Energy Modeling for Residential Applications

Concentrated Solar Thermal Power Technology

Solar Energy Deployment in the UAE: The role of the Masdar Institute

SMART SOLAR RESOURCE ASSESSMENTS

How do weather, environment and location affect solar?

Solar (PV) Panel Installation and Maintenance With The Help Of PVSYST And PVSOL

Cutting edge technology since 1927.

Content January Successful Debut of SOLYS 2 Sun Tracker. Contact

INACCURACIES OF INPUT DATA RELEVANT FOR PV YIELD PREDICTION

Thin Film TECHNOLOGY ADVANTAGE

APPLICATION NOTE PREDICTING AND MONITORING PV ENERGY PRODUCTION

Volume I Issue X Dec 2012 IJLTEMAS ISSN

SOLAR ENERGY CHRIS PRICE TECHNICAL SERVICES OFFICER BIMOSE TRIBAL COUNCIL

SOLAR ENERGY Recent growth and future prospects South Africa s Electricity Supply Conference

WREF 2012: P50/P90 ANALYSIS FOR SOLAR ENERGY SYSTEMS USING THE SYSTEM ADVISOR MODEL

Solar Monitoring Stations

Newsletter 24 Improved Alignment and Testing of LAS MkII

Solar Energy implementation in the Middle East: Challenges and Opportunities Matteo Chiesa Laboratory for Energy and Nano Science Masdar Institute

UW-Rock County Solar Project

Solar Input Data for PV Energy Modeling

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

20-CSP Technologies. ECEGR 452 Renewable Energy Systems

Product Portfolio 2016 v2. Trace the sun Capture the benefit

AR No. # - Install Photovoltaic Array

Green Star Photovoltaic Modelling Guidelines

Performance Characterization of Cadmium Telluride Modules Validated by Utility-Scale and Test Systems

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Scintillometry in China. Introduction of SOLYS 2. Industrial Applications in Germany

Introduction to Solar Energy Technology. Introduction to Solar Energy Technology. Introduction to Solar Energy Technology

Photovoltaics under concentrated sunlight

Australian Technical Guidelines for Monitoring and Analysing Photovoltaic Systems

DEVELOPMENT OF A SOLAR COLLECTOR/SOLAR WATER HEATING SYSTEM TEST CENTER IN IRAN

AR No. # - Solar Thermal

SolFocus Concentrator Photovoltaics An Introduction

Journal of American Science 2014;10(8) Software Design of Photovoltaic Grid-Connected Power Plants

Basic principles for designing PV plant monitoring systems

An innovative HCP/T collector and its potential SHC applications

Solar energy. Energy Centre summer school in Energy Economics February Kiti Suomalainen

A technique for accurate energy yields prediction of photovoltaic system

AN EFFECTIVE STUDY ON PERFORMANCE ANALYSIS OF GRID CONNECTED PV SYSTEM

IN SITU PERFORMANCE TESTING OF BIFACIAL PHOTOVOLTAIC PANELS

Solar Learning Lab. User s Guide. Heliotronics, Inc Main Street Hingham, MA (781) FAX (781)

LESSON PLAN B.S.C. THIRD YEAR ( REGULATION)

Introduction to Solar Energy Technology

BUILDING INTEGRATED PHOTOVOLTAIC TEST FACILITY

Concentrated Solar Power (CSP)

Solar Technology. Solar Lenses We have developed a unique thin film lens that focuses the sun s energy to a hightemperature

Extreme Engineering for Extreme Conditions

Guide to Data Requirements for AWEFS and ASEFS. December Supplementary material to the Solar and Wind Energy Conversion Models

A Guide to Data Requirements for AWEFS and ASEFS. October Supplementary material to the Solar and Wind Energy Conversion Models

Monitoring of 20 kwp photovoltaic system

Estimating Solar Radiation and Photovoltaic System Performance, the PVGIS Approach

Estimating Solar Radiation and Photovoltaic System Performance, the PVGIS Approach

Will your product last? Put it to the test.

Radiant energy from the sun has powered life on Earth for many millions of years.

Transcription:

optimal solutions and systems Solar Irradiance Monitoring in Solar Energy Projects Learn what is important in solar irradiance measurements in solar energy projects. Find optimal solutions and systems for PV, CPV and CSP projects. Solar radiation is the input for all solar energy generation systems. Measuring solar irradiance provides knowledge to make important decisions on future energy yield, efficiency, performance and maintenance crucial factors for investments! This brochure provides helpful guidelines for Photovoltaic and Solar Thermal projects, including practical information on site prospecting and the efficiency monitoring of solar power plants.

Glossary of Terms Irradiance radiant flux received by a surface per unit area, irradiance is measured in W/m 2 Direct Normal Irradiance (DNI) DNI is the amount of solar radiation received per unit area by a surface that is held perpendicular (normal) to the rays that come in a straight line from the direction of the sun at its current position in the sky. DNI is measured by a pyrheliometer with a field of view of 5, mounted on an automatic sun tracker. Diffuse Horizontal Irradiance (DHI) DHI characterizes the amount of energy coming from the sky after being scattered in the atmosphere. DHI is measured by a pyranometer shaded from the direct sunlight. Global Horizontal Irradiance (GHI) GHI is the amount of solar radiation received per unit area by a horizontal surface from the hemisphere above. It comprises Direct Normal Irradiance, corrected for the angle of incidence on the surface, and Diffuse Horizontal Irradiance. The relationship is; GHI = DHI + DNI cos(θ), where θ is the solar zenith angle (vertically above the location is 0, horizontal is 90 ). GHI is measured by a pyranometer mounted horizontally. Plane of Array (POA) irradiance Also known as Global Tilted Irradiance (GTI) - irradiance incident on the tilted plane (i.e. PV panel). POA irradiance is difficult to calculate from other measurements due to the complex nature of radiation reflected from the ground and shadowing effects. It can be accurately measured by a pyranometer installed at the same tilt angle as the PV panels. Kipp & Zonen provides a wide range of products to measure solar radiation accurately and reliably: Proven quality: ISO 9001:2008 certified company. More than 85 years of experience and expertise in solar radiation measurement equipment Worldwide reference customer base Worldwide network of representatives: 4 sales offices and 45 distributors around the globe What we can do for you Technical services, installation, calibrations and training available worldwide Useful accessories for easy installation and maintenance Advice on applications and best practices

Site Prospecting and Energy Forecast Where to build a solar power plant? Which technology will have the lowest levelized cost of energy (LCOE) and bring maximum return on investment (ROI)? What is the optimal size of the power plant on a given site? Knowing the amount and distribution of solar irradiance with low uncertainties will help to answer such questions. Recommended system SOLYS 2 automatic sun tracker, with shading ball assembly and sun sensor (for active tracking), fitted with: The amount of solar radiation available over time under the local environmental conditions is a key input for choosing the optimal location, technology and size of a solar energy project. Feasibility studies and technical due diligence calculations of a solar energy project always start with energy resource assessment. High precision on-site measurements of solar radiation provide the lowest uncertainty for bankable data about the energy resource and the possible energy yield. Such measurements are performed by a high quality solar radiation monitoring station that measures all three components of solar radiation: direct normal irradiance (DNI), diffuse horizontal irradiance (DHI) and global horizontal irradiance (GHI). Also, other meteorological parameters relevant to the project, such as air temperature, humidity, precipitation, wind speed and direction need to be monitored by a dedicated weather station. ISO 9060 First Class pyrheliometer for DNI measurement (CHP 1 or SHP1) Two ISO 9060 Secondary Standard pyranometers, of which one unshaded for GHI measurement and one shaded for DHI measurement (CMP10 or SMP10) Ventilation units for pyranometers, depending upon the site environment (CVF4) with air temperature, humidity, precipitation, wind speed and direction sensors High quality meteorological data logger Optional POM-01 or POM-02 sky radiometer A complete solar monitoring station consists of a pyrheliometer mounted on an automatic sun tracker for measurements of DNI, a shaded pyranometer for measurements of DHI and an unshaded pyranometer for measuring GHI; plus a high performance data logger to acquire and store the measured values. Solar monitoring stations can be extended by spectral instruments and/or a sky radiometer to study the aerosol concentrations in the atmosphere, which is especially important in arid desert areas with high concentrations of sand and dust, in the air. Automatic sun tracker SOLYS 2 with a pyrheliometer and two ventilated pyranometers. The ventilation units help to keep the pyranometer domes clean from dust and dew. Passion for Precision

Fixed Photovoltaic (PV) Installations Recommended system SMP3 or SMP10 pyranometer for POA measurements, LOGBOX datalogger Rooftop installations, Building Integrated Photovoltaic (BIPV) systems and small ground-mounted PV plants (kw range) Recommended system For both roof and ground-mounted installations solar radiation measurements significantly improves the monitoring of the performance of the solar energy system. An additional pyranometer for GHI is optional In most smaller PV installations, if any monitoring is done, it is usually a comparison of the output from one PV panel to another PV panel. You then monitor the relative efficiency and can detect a faulty panel or connection. Although useful, it actually doesn t tell you whether you get the maximum out of your system. As long as you do not measure the input of solar radiance into to the PV installation, you will not know whether you should be satisfied with the output of your PV installation. To monitor the energy yield of the PV installation a tilted pyranometer is installed at the same angle as the panels to measure plane of array (POA) irradiance. A horizontal pyranometer can be added for global horizontal irradiance (GHI) measurements this allows comparison of the on-site data to other sites and to data received from meteorological stations. Cost-efficient low-maintenance smart pyranometers SMP3 (ISO 9060 Second Class) and SMP10 (ISO 9060 Secondary Standard) are ideal for small scale installations. Smart pyranometers have internal digital signal processing, an amplified analogue output (4 to 20 ma or 0 to 1 V) and a RS-485 serial communication with Modbus protocol. They can be directly connected to modern inverters and easily integrated into digital supervisory control and data acquisition (SCADA) systems.

Recommended basic system Medium and large commercial PV installations (MW range) In medium and large installations (>1 MW) the uncertainties in the efficiency of energy generation have considerable impact on the project s profitability. A measurement uncertainty of as low as a couple of percent for a plant of nominal capacity of several MW can mean a significant difference in energy production forecasts and can therefore directly impact profit or loss! A minimum of two ISO 9060 Secondary Standard pyranometers, Recommended one for POA and one system for GHI measurement (CMP10 or SMP10) For larger plants, additional pyranometers should be installed, distributed over the site Measurements of POA and GHI irradiance are crucial for determining performance ratios and monitoring energy yield efficiency. Performance ratio monitoring requires high quality measurement instruments and reliable data collection. It is recommended to use ISO 9060 Secondary Standard pyranometers for the highest quality of the data, for example the CMP10 or SMP10 low maintenance pyranometers. For large scale plants a high quality solar monitoring station is recommended for measurement of all three components of solar radiation (GHI, DHI and DNI). This data can be complimented by monitoring POA irradiance at several sites on the plant, typically feeding into the array inverters. Smart pyranometers with RS-485 Modbus are addressable, can be linked to a single network loop and can be integrated into the SCADA system of a solar plant for easy and practical monitoring and reduced cable costs. Recommended advanced system SOLYS 2 automatic sun tracker, with shading ball assembly and sun sensor (for active tracking), fitted with: ISO 9060 First Class pyrheliometer for DNI measurement (CHP 1 or SHP1) Two ISO 9060 Secondary Standard pyranometers, of which one unshaded for GHI measurement and one shaded for DHI measurement (CMP10 or SMP10) Ventilation units for pyranometers, depending upon the site environment (CVF4) with air temperature, humidity, precipitation, wind speed and direction sensors High quality meteorological data logger Large projects often span an area where meteorological conditions might vary due to differences in microclimate. In these cases solar monitoring stations and weather stations may need to be placed in several parts of the plant to closely monitor the local conditions. Using two or more solar monitoring points ensures redundancy of the measurements. When some of the instruments need to be replaced or sent for calibration, the data collection will remain continuous. Passion for Precision

Tracking Photovoltaic (PV) Systems Recommended system Two ISO 9060 Secondary Standard pyranometers (CMP10 or SMP10), one for GHI measurement and one mounted on panel tracker for POA measurement For larger plants, additional pyranometers should be installed, distributed over the site PV systems with one- or two-axis tracking can considerably increase the output of solar panels by ensuring higher received irradiance during the day. To monitor the performance of the system the POA irradiance should be measured, along with the GHI, using high quality pyranometers (ISO 9060 Secondary Standard). The pyranometers can be mounted on the solar panel tracker or on a dedicated high precision sun tracker. Concentrating Photovoltaic (CPV) Systems Recommended basic system SOLYS 2 automatic sun tracker with sun sensor for active tracking and small top plate, fitted with: ISO 9060 First Class pyrheliometer for DNI measurement (CHP 1 or SHP1) ISO 9060 Secondary Standard pyranometer for GHI measurement (CMP10, SMP10, CMP 21 or CMP 22) Ventilation unit for pyranometer, depending upon the site environment (CVF4) CPV systems use optics to concentrate a large area of sunlight onto a small solar cell and are either refractive (with lenses) or reflective (with mirrors). To achieve high concentration ratios the optics have a narrow field of view and only make use of direct normal irradiance (DNI) from the sun. DNI is most accurately measured by a high quality pyrheliometer mounted on a precise automatic sun tracker to provide reliable data about the solar radiation input. An advanced system with pyranometers measuring diffuse and global irradiance (DHI and GHI) can provide a quality check of the DNI measurements. High quality meteorological data logger Recommended advanced system As the basic system, plus: Shading assembly Second pyranometer for DHI measurement (CMP10, SMP10, CMP 21 or CMP 22) with air temperature, humidity, precipitation, wind speed and direction sensors

Recommended system Concentrating Solar Power (CSP) Systems Thermal systems use the direct normal irradiance (DNI) from the sun to generate heat, which can be used as the energy source for steam turbine electricity generators. These systems use mirrors to concentrate solar radiation. Unlike PV cells, they can take advantage of the full spectrum of solar radiation, including ultraviolet and near infrared light, leading to high efficiencies. For such systems it is extremely important to monitor the broadband solar radiation with high precision, because sky conditions have a strong influence on the performance of a CSP plant. To predict the energy yield of a CSP system with a minimum of uncertainty it is crucial to measure solar radiation locally. Satellite measurements and related models don t take into account the effect of local climatic conditions, such as clouds, nor do they include the effect of local aerosols (dust, sand and other particles). Two CSP plants in different locations with equal direct irradiance totals, according to satellite data, may have very different energy outputs, due to differences in clouds and aerosols in the particular locations, which affect the incoming radiation. SOLYS 2 automatic sun tracker, with shading ball assembly and sun sensor (for active tracking), fitted with: ISO 9060 First Class pyrheliometer, for DNI measurement (CHP 1 or SHP1) Two ISO 9060 Secondary Standard pyranometers, of which one unshaded for GHI measurement and one shaded for DHI measurement (CMP10, SMP10, CMP 21 or CMP 22) Ventilation units for pyranometers, depending upon the site environment (CVF4) with air temperature, humidity, precipitation, wind speed and direction sensors High quality meteorological data logger Optional POM-01 or POM-02 sky radiometer To ensure the reliability and redundancy of the data, a typical CSP solar monitoring station uses high precision instruments with low uncertainty for the measurements of direct, diffuse and global irradiance. This way the direct radiation measurement can be compared with values derived from the global and diffuse radiation. This allows detection of problems with a particular instrument, for example due to soiling. The overall effect of aerosols on the incoming radiation can simply be measured by solar irradiance sensors, but to study the type of aerosols to improve predictions of solar energy available over time, one should use a sky radiometer, such as the POM-01 or POM-02. Passion for Precision

Choosing the Right System Application Measurement Parameters Measurements Instruments Basic Advanced Prospecting DNI, GHI, DHI, weather, data logger Automatic sun tracker: SOLYS 2 ISO 9060 First Class pyrheliometer: CHP 1 or SHP1 ISO 9060 Secondary Standard pyranometers: CMP10 or SMP10 Fixed PV Small POA, GHI optional Smart pyranometers SMP3 or SMP10 integrated into monitoring system Fixed PV Medium POA, GHI POA, GHI, at least 2 locations, weather, data logger Fixed PV Large GHI, at least 2 locations, distributed POA CPV DNI, GHI, data logger POA, GHI, DNI, DHI, distributed POA, weather, data logger DNI, GHI, DHI, weather, data logger ISO 9060 Secondary Standard pyranometers: CMP10 or SMP10 Automatic sun tracker: SOLYS 2 ISO 9060 First Class pyrheliometer: CHP 1 or SHP1 ISO 9060 Secondary Standard pyranometers: CMP10 or SMP10 Tracking PV DNI ISO 9060 First Class pyrheliometer: CHP 1 or SHP1 Automatic sun tracker: SOLYS 2 ISO 9060 First Class pyrheliometer: CHP 1 or SHP1 ISO 9060 Secondary Standard pyranometers: CMP10 or SMP10 CSP DNI, GHI, DHI, weather, data logger Automatic sun tracker: SOLYS 2 ISO 9060 First Class pyrheliometer: CHP 1 or SHP1 ISO 9060 Secondary Standard pyranometers: CMP10, SMP10, CMP 21 or CMP 22 Kipp & Zonen and its local representatives can also design and offer complete solutions for solar monitoring at solar energy projects including: Dataloggers for data acquisition Communication systems for data transmission PV module temperature sensors s Please contact us to discuss your solar energy project. HEAD OFFICE Kipp & Zonen B.V. Delftechpark 36, 2628 XH Delft P.O. Box 507, 2600 AM Delft The Netherlands +31 15 2755 210 info@kippzonen.com www.kippzonen.com Distributor for Germany and Switzerland R olf Gengenbach Messtechnik Heinrich-Otto-Straße 3 D-73262 Reichenbach / Fils T +49(0)7153 9258-0 F +49(0)7153 9258-1 60 E info@rg-messtechnik.de www.rg-messtechnik.de Passion for Precision