VWR B-Series Balances Operation Manual

Similar documents
HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE

High Precision Balances. Operation Manual

EC Series Toploading Balances

WeighSouth. WBT Toploader Balance

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

Adam Equipment ADK SERIES

Inscale Measurement Technology Ltd Tel: Fax:

Operating instructions Analytical balance

MANUAL JCE-SERIES CHAPTER

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

Operating Manual. Professional Weighing Equipment SCT SERIES Small Counting Scales. SCT 600g SCT 1200g

Operation Manual. Professional Weighing Equipment. HRB Series intelligent weighing scale HRB 103 HRB 203 HRB 303 HRB 1002 HRB 602

PORTION CONTROL SCALE

INSTRUCTION MANUAL CONTECH

Table of contents. 1. Introduction

PALLET SCALE CPS SERIES OWNER'S MANUAL

Adam Equipment LBC SERIES. (P.N , RevisionB1, January 2010)

PD- OWNER S MANUAL. ECR Interface Scale 9002-PD

High Precision Balances

Adam Equipment LBC SERIES. (P.N , RevC, August 2011)

BC Series Compact Counting Scale INSTRUCTION MANUAL

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

Professional Weighing Equipment. PIZA Series Bench Weighing Scale PIZA 12 PIZA 25. Operation Manual

MS 3801 USER MANUAL. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.

BEFORE USING THE COUNTING SCALE

LC-VS 60 Operation Manual

Professional Weighing Equipment. Wheelchair Scale. Operating Manual LWC 800

Operating Manual. Professional Weighing Equipment. HRB Series intelligent weighing machine HIGH RESOLUTION BALANCE

User Manual. Precision Balances XSR models

KERN EMS Version /2012 GB

Models TJ30K TJ15K TJ6K TJ3K. Resolution Ratio 1g 0.5g 0.2g 0.1g Calibration graduation 10d 10d 10d 10d

Pennsylvania Scale Company. Model 40SS Multi-Function Digital Indicator. Operation & Calibration Manual Software Version

Professional Weighing Equipment Digital Weight Indicator

CN Series P.N , Software rev. T 8, Revision A1- July 2014

Instruction Manual: AGZN and AGCN Analytical Balances

BA110 Electronic Balance 5000g x 1g. Impact Test Equipment Ltd & User Guide. User Guide

CONTENTS Cautions before using 1-2. Specification and characteristics of products

Professional Weighing Equipment REMO/REMO-R. Operation Manual

Operation Manual. Professional Weighing Equipment. HRB Series intelligent weighing scale HIGH RESOLUTION BALANCE WITH COUNTING FUNCTION

Operator Manual. OHAUS Aviator 7000

MODEL ASCS-15 CRANE SCALE

Operating instructions. METTLER TOLEDO B balance line AB PB SB

Weighing Indicator YH-T3. User Manual

INSTALLATION uline.com UNPACKING ASSEMBLY LEVELING H-1096, H-1097 H-1098, H-1099 DELUXE COUNTING SCALE

Instruction Manual Pocket scale

Professional Weighing Equipment !!!! Weigh Bars. Dust and Waterproof Scale IP65 !! 1

Series. 3 or 12 lb. Capacity. 129 Cramer Road, Jewett, New York USA Fax:

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

WS 10 Weighing indicator USER MANUAL

Operating instructions Precision balances

Rook Currency Counter

DJ Switch 10F V2 ORDERCODE 50365

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

IS16EDE-H, IS16EDE-H0CE, IS34EDE-H, IS34EDE-H0CE, IS64EDE-H, IS64EDE-S, IS64EDE-H0CE

Instruction Manual: AD Series

TT DataTran 162 SL Installation Guide

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

User s Guide. Weighing Indicator WIDRA - HF L / HF S 2000/02/11 21:21:58. No. TARE NET GROSS TOTAL

Contents Balance-pan fixing

DIGITAL PORTION SCALE PS-5 OWNER S Manual

Operation Instructions

Use and Maintenance Manual

MEDIZINTECHNIK FÜR TIERÄRZTE

Manual PCE TP 1500B/3000B

64C Amplification Block. Instruction Manual

User Manual. Precision Balances and Comparators XPR models

CSG A.L.C. COUNTING SCALE USER MANUAL

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Splash-Proof Weighing Scale Operation Manual

Sartorius Talent Sartorius Gem, Gold

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Operating Instructions. METTLER TOLEDO SB Precision Balance.

LOW PROFILE FLOOR SCALE

Adam Equipment. PGW..M SERIES (P.N. 8723, Revision B1, July 2011) Software rev.: 3.38 or above

DS-520 Digital Indicator Operation Manual 73366

Instruction Manual Counting balance

Operating manual Pallet scale

Contents

X320 IP69K. Digital Indicator Operator Manual 003X M02

User Manual Cole-Parmer Symmetry Balances Analytical Balances: LA, LA.C, and LA.N Series Precision Toploading Balances: LT, LT.C, and LT.

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

Contents

Operating manual Analysis and precision balances

BALANCES APP/2C SERIES

PD662 LOOP-POWERED METER

OP-903 INDICATOR USER S MANUAL

Sabre P Model PD603 Process Meter Instruction Manual

MSI6260cs. RF Digital Crane Scale. Calibration Guide

Operating instructions Analytical and precision balances

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Explorer. Analytical and Precision Balances. Features Include:

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

Operating instructions Analytical and precision balances

Installation & Calibration Manual

Table of Contents. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

SPECIFICATIONS. Model CSW-10AT-LT Electronic Lift Truck Scale: Operating Temperature: 14 to 140 deg. F (-10 to 60 deg. C)

Operating Instructions METTLER TOLEDO Excellence XS Precision Balances

Transcription:

VWR B-Series Balances Operation Manual

TABLE OF CONTENTS SAFETY PRECAUTIONS. 1 GETTING STARTED..... 1 INSTALLATION & SET-UP.... 2 POWER CONNECTION.... 3 ANTI-THEFT DEVICE.... 3 LEVELING.... 3 CALIBRATION..... 4 TARE FUNCTION..... 4 GOOD WEIGHING TECHNIQUE... 5 DISPLAY OVERVIEW....... 6 PROGRAMMING INSTRUCTIONS.... 7 WEIGHING PROGRAMS Basic Weighing Mode...... 7 Multiple Weigh Mode..... 7 Percent Weighing Mode...... 7 BALANCE SETTING PROGRAMS Ambient Conditions (Electronic Filter) Settings... 8 Auto Zero Setting...... 8 Audible Key Tone Settings...... 8 DATA INTERFACE SETTINGS.......... 9 PROGRAMMING MENU CODES QUICK REFERENCE GUIDE.... 10 CARE & MAINTENANCE... 11 ERROR MESSAGES & TROUBLESHOOTING GUIDE.... 11 SERVICE & TECHNICAL SUYPPORT....... 12 DISPOSAL....... 12 CE COMPLIANCE AND MARKING.... 12 SPECIFICATIONS...... 13 INSTRUMENT DIAGRAM...... 14 * Factory Default Setting i

Congratulations and thank you for selecting a VWR B-Series Balance, we appreciate your business. Your balance was designed and manufactured to give you years of service. SAFETY PRECAUTIONS - Check the instrument for any visible signs of damage before you apply power. - Ensure the power supply is compatible with your instrument AND the local line voltage. - Do NOT operate in Hazardous Locations. Check with your Safety Officer with any questions or concerns. - Make sure no liquid enters the housing. Use a damp cloth to clean the instrument. - Do not locate in areas where corrosive gases are present. - Avoid exceeding/overloading the weigh capacity or dropping samples on to the weigh pan. Weight overload and shock may damage the instrument and void the warranty - Connect only accessories and options that are optimally designed for use with your balance. The operator shall be responsible for any modifications to the equipment and for any connection of cables, power supplies or peripheral equipment that are not compatible with VWR B-SERIES Series Balances. - Unplug the balance from AC power before you connect or disconnect a peripheral device (Printer or PC) to or from the interface port - The only way to completely turn off the electrical source completely is disconnect the power cord. If there is any indication that safe operation of the balance is no longer warranted: - Turn off the power and disconnect the equipment from AC power immediately. - Lock the equipment in a secure place to ensure that it cannot be used for the time being. - Notify the nearest Service Center. A trained service technician must perform repair work. GETTING STARTED Check the contents of your shipping carton for the following: - VWR B-Series Balance - Weigh Pan - Pan Support (VWR-64B, 124B, 214B, 203B, 403B, 503B, 4002B & 5002B) - Draft Ring (VWR-64B, 124B, 214B, 203B, 403B & 503B) - Dust Guard (VWR-64B, 124B, 214B, 203B, 403B & 503B - Operation Manual - Power Supply Please read your operation manual and follow the instructions for installing your balance. Please keep your packaging for future transport and remember to return your Warranty Card. Page 1

INSTALLATION & SETUP - Choose a location that is free from the influences of the following: - Drafts: Fans, Heat/Air Duct, Doorways or High Traffic Areas. - Vibrations. - Extreme Temperature Fluctuations: Sunlight, Ovens, or Environments with Wide Temperature Variations. - Voltage Fluctuations. Do Not Share Current with Other Instruments that Draw Voltage in an Inconsistent Manner such as Fluorescent Lights, Centrifuges and the like. - Place Instrument on a Level, Rigid Surface. - Level the Instrument. - Allow 60 Minutes for Warm-up. - Calibrate. All B-Series are calibrated at the factory prior to shipment. Transportation of the instrument plus the differences in barometric pressure, humidity and ambient temperate conditions require calibration at the point of use. Calibrate regularly, at least once a week, to ensure accurate weighing results. Place components inside the chamber in the following order (Models VWR-64B, 124B, 214B, 203B, 403B & 503B) - Dust Guard - Draft Ring - Pan Support - Weighing Pan Place weigh pan on balance (Models VWR-4002B & B-5002B) Page 2

AC POWER CONNECTION - When connecting power use the original AC adapter supplied with the balance. Using an unapproved power supply may damage the instrument and void the warranty. - Ensure the power supply is compatible with your instrument AND the local line voltage. - Connect the plug to the instrument. - Connect adapter to the power outlet. - Original Power Supply: Input: 100-240VAC, 50-60Hz, 0.6A Output: 15VDC, 1A Polarity: Inside = -, Outside = + Antitheft Locking Device To protect against theft place a cable through the built-in security device located on the back of the balance next to the leveling bubble and connected to a fixed point, secure with a lock. Leveling the Balance A slight unevenness in a balance will result in an inaccurate measurement. For accurate calibration and weighing results level the balance at installation and any time the instrument is moved to a new location. Only the 2 front feet are adjusted to level all B-Series balances. Turn the 2 front feet as shown in the diagram until the level bubble (located on the back of the balance) is centered within the circle of the level indicator. In most cases leveling the balance will require several adjustment steps. Page 3

CALIBRATION Calibration is required at installation (see Installation & Set-up) and at regular intervals thereafter. Calibrate if the balance is moved to a new location. 1. Allow a 60-minute warm-up period. 2. Press Tare to zero the balance (0.0000g) if required. 3. Remove all items from weigh pan. 4. Ensure that you are in the gram (g) weigh mode. 5. Press CAL Key once. The preprogrammed calibration weight value for the balance will appears on the display, ie: 100.00 (VWR-124B) and flash. Place the appropriate calibration weight (gram) for your balance (see chart below) within 2 Seconds. 8. When calibration is complete the balance will beep and display Cal-End and then return to the weigh mode. Calibrate on a regular basis, we recommend once a week, or more. If the above conditions are not met an error message will appear on the display. See Error Messages and Troubleshooting Guide, page 11. Calibration Weight Values* VWR-64B 50g ASTM Class 1 VWR-124B 100g ASTM Class 1 VWR-214B 200g ASTM Class 1 VWR-203B 200g ASTM Class 1 VWR-403B 200g ASTM Class 1 VWR-503B 500g ASTM Class 1 VWR-4002B 2000g ASTM Class 1 VWR-5002B 5000g ASTM Class 1 * Class 1 or Better TARE FUNCTION TARE is defined as net weight. Should you wish to use a beaker, flask or some other container for your sample simply place the container on the weigh pan and press the TARE KEY once. Please note that any container that is tared will decrease the remaining capacity available on the balance by the weight of the container. If you do not use a container for weighing verify the reading is "0" before placing a sample on the weigh pan. If not, press TARE KEY to display "0". Page 4

Good Weighing Technique Working with precision balances requires a steady hand and an even, uninterrupted technique. Use forceps or other suitable utensils to place the sample (and sample container) on the weigh pan as fingers are hygroscopic. If the balance has been idle and the draft chamber doors closed for an extended period, perform a number of test measurements before you begin weighing to allow the atmospheric conditions (temperature, RH and barometric pressure) inside the weighing chamber adjust to the ambient temperature outside the chamber. Rapid changes in atmospheric conditions will have an adverse effect on the weighing result. A series of test measurements will also help develop a smooth working rhythm. Ensure the sample and container have acclimated to the ambient temperature of the instrument in use. Place the sample gently on the weighing pan, in the center. Use the smallest sample container possible to reduce the influence of laminar air movement. When working with aqueous solutions select a sample container with a small opening to minimize the effect of evaporation. Cover the container opening when working with light volatiles. Static electricity may have an adverse effect on weighing results such as drift and non-repeatability. When working with samples or containers with low conductivity properties such as powers you can optimize the performance of the balance by: ü Shield the Sample from the Weigh Pan (Metal Container and /or Foil) ü Use Anti-static Device (Brush or Ionizer) ü Increased Ambient Humidity Levels ü Anti-static Weigh Containers Avoid weighing magnetically charged (ferrous) materials such as ion, nickel and ion. To minimize the effects (non-repeatability) of ferrous material: ü Demagnetize the Sample ü Increase the Distance of the Sample from the Weigh Pan ü Use Below Pan Weighing (Weigh-below) Procedure A good working knowledge of the effects from the various environmental conditions, sample matrices, container profiles and weighing technique is paramount for high precisions weighing. Preventative measures to minimize the effects of these conditions will provide you with optimal weighing results from your balance. Page 5

DISPLAY OVERVIEW 1 3 5 00000.000 g (2) 6 (4) (2) Key Pad # Function 1 On / Off Key 2 Tare Keys (Right & Left Sides) 3 Calibration Key 4 Mode Key: g, lb, oz, ct, mg or kg, ozt, dwt, gn, Percent (%), Count & Animal Weigh, Milligram (mg) Mode (0.01mg, 0.1mg & 0.001g Models) Kilogram (kg) Mode Key (0.01g Models) 5 Print (Data Send) Key 6 Stability Indicator Page 6

PROGRAMMING INSTRUCTIONS The B-Series offers several Weigh Modes, Balance Settings and Interface Options. Weigh Modes include Gram (g) Milligram (mg) / Kilogram (kg) and Percent Weighing. The B-Series also offers adjustable settings for Auto Zero, Baud Rates, Print (data send) Commands, Electronic Filtering and Audible Key Tone functions. To access the Weigh Modes simply Press Mode Key to scroll between g, lb, oz, ct, mg or kg, ozt, dwt, gn, Parts Counting, Percent Weighing (%) and Animal Weigh appears in the display. Please see Display / Keypad Diagram. To access and adjust the Program Settings of your choice, please following the instructions listed below: Step Display 1. Press On / Off Key to Turn Balance Off. Blank (w Stand-by Power Indicator On) 2. Press Print Key Twice. C1 - - 0 3. To advance to the next Program Setting or Interface Option Press Print Key. C2 - - 0, C3 - - 0, C4 - - 0, etc. 4. To adjust a Program Settings or Interface Option Press Mode Key (Example: Auto Zero) C3 - - 0, C3 - - 1, C3 - - 2, etc. 5. To Save Programming Settings Press ON / Off Key Blank (w Stand-by Power Indicator On) 6. Press On / Off Key to Turn Balance On and Return to the Weigh Mode. 0.0000 WEIGHING PROGRAMS 1) Basic Weighing Mode (g, mg/kg) Once installation and calibration have been completed the B-Series is ready to weigh. Simply place a sample on your weigh pan and the result will appear on the display. Response (stabilization) time on the B-Series is 3 seconds, average (5 Seconds on B-25). When the balance has reached stability icon will appear on the left hand side of the display. Gram (g) is the factory default setting. To select another unit of measure, Press the Mode Key until the desired mode of measurement (g, lb, oz, ct, mg or kg, ozt, dwt, gn) appears in the display. 2) Percent Weighing Mode Percent Weighing mode allows the user to obtain values in a percentage that are proportional to an initial reference weight. To activate the Percent Weighing function simply Press the Mode Key until the mode indicator Percent (%) appears on the display. Once you have selected the Percent Weighing Mode place the reference sample on the weigh pan and Press CAL Key to assign the reference sample a value of 100%. If you would like to use a sample container, remove the reference sample, place the container on the balance and Press Tare Key. Place your sample into the container) and the percentage value will appear on the display. Example 50%. 3) Parts Counting Mode In addition to weighing samples, B-Series balances have the ability to count parts. For the best results please ensure that you have selected a balance with the proper resolution for your smallest part and that the parts are approximately equal in weight. For example, if you wish to count 500 parts at a time that weigh 0.001g per part you should use a balance with 0.001g (or greater) resolution. In addition, you should select the highest level of Initial Sample Size (i.e.: 100) to ensure an accurate average piece weight as a reference. The factor default setting for Initial Sample Size is Ten. Page 7

There are five Initial Sample Setting Option (see below). Follow the Programming Instructions listed above to adjust the Initialize Size that is appropriate to your sample. Once you have selected the Initial Sample Size Press the Mode Key until the COUNT appears on the display. Place the reference pieces on the weigh pan and Press CAL Key to assign the reference sample a value of your parts. If you would like to use a sample container, remove the reference sample, place the container on the balance and Press Tare Key. Place your parts into the container and the number of parts (count) value will appear on the display. Example 100. Sample Size Settings Ten (10) C2 - - 0 Twenty (20) C2 - - 1 Fifty (50) C2 - - 2 One Hundred (100) C2 - - 3 One Thousand (1000) C2 - - 4 BALANCE SETTING PROGRAMS 1) Ambient Condition (Electronic Filtering) Setting All B-Series have an adjustable Ambient Condition (electronic filter) setting. This feature allows you to adjust the balance to optimize performance in less-than-idea environments. For most applications and environments the factory default setting (C7 - - 1) should provide optimal performance (stability and speed of response). If your environment is not ideal for good weighing performance you may improve the performance by adjusting the Electronic Filter Setting that is better suited for your environment. If adjustment to the electronic filtering does not improve the performance of your balance (stability & response time) you should move the instrument to a location better suited to precision weighing (see Installation & Set-up, page 2 and Good Weighing Technique, page 5). Electronic Filter Settings No Filtering Very Stable Environment C7 - - 0 Limited Filtering Good Environment C7 - - 1* Moderate Filtering - Poor Environment C7 - - 2 Strong Filtering Very Poor Environment C8 - - 3 7. 2) Auto Zero Setting B-Series come with an adjustable Auto Zero Setting. The Factory Default Setting is C3 - - 5, 5 Counts / Divisions. However, you may adjust the counts / divisions or deactivate the Auto Zero Function by simply entering the programming code listed below following the Program Instructions provided on page Auto Zero Settings Auto Zero, 0 Divisions (Off) C3 - - 0 Auto Zero, 1 Division C3 - - 1* Auto Zero, 2 Divisions C3 - - 2 Auto Zero, 3 Divisions C3 - - 3 Auto Zero, 4 Divisions C3 - - 4 Auto Zero, 5 Divisions C3 - - 5* Page 8

3) Audible Key Tone Setting B-Series come with an adjustable Audible Key Tone Setting. The factory default setting is on. However, you may enable the Audible Key Tone by following the Programming Instructions listed on page 7. Audible Key Tone Settings Always Off C6 - - 0 Always On C6 - - 1* DATA INTERFACE SETTINGS All B-Balances come with RS232 interface connection. To adjust the Data Interface Settings (Baud Rate, parity & Print Command) enter the appropriate programming codes listed on page 13 using the programming instructions provided on page 7. Please note that Data Collection Software is required to collect weighing data sent from the balance. Contact you dealer for information on printers and data collection software. General Specifications: Interface: Serial Operation: Asynchronous, Full Duplex Standard: RS232 Handshake: CTS = Clear to Send DTR = Data Terminal Ready Character Coding: 8-bit ASCII Character Format: 1 Start Bit 7-bit ASCII Parity: None 1 Stop Bit Data Output Format; Balance: 16 Characters Data Bits 7-bit ASCII Synchronization: 1 Start Bit; 1 Stop Bit Display: Stable + 10.0000 g Unstable 10.0001 kg Connector: DB9 BALANCE PC TXD 2------------------------------------- 2 RXD RXD 3------------------------------------- 3 TXD SG5--------------------------------------- 5 SG Baud Rate 2400 Baud* C4 - - 0 1200 Baud C4 - - 1 4800 Baud C4 - - 2 9600 Baud C4 - - 3 Print/Send Data Manual, At Zero with Stability C5 - - 0 Manual with Stability C5 - - 1 Manual with Stability* C5 - - 2 Continuous (0.3 Seconds) without Stability C5 - - 3 Page 9

PROGRAMMING MENU CODES QUICK REFERENCE GUIDE Code Function C1 C2 C3 C4 C5 C6 C7 C8 Parts Counting C1 - - 0* Sample Size = 10 C1 - - 1 Sample Size = 20 C1 - - 2 Sample Size = 50 C1 - - 3 Sample Size = 100 C1 - - 4 Sample Size = 1000 C3 - - 0 C3 - - 1 C3 - - 2 C3 - - 3 C3 - - 4 C3 - - 5* C4 - - 0* C4 - - 1 C4 - - 2 C4 - - 3 C5 - - 0 C5 - - 1 C5 - - 2* C5 - - 3 C6 - - 0 C6 - - 1* C7 - - 0 C7 - - 1* C7 - - 2 C7 - - 3 Reserved No Function Auto Zero Auto Zero Off 1 Count / Division 2 Counts / Divisions 3 Counts/ Divisions 4 Counts / Divisions 5 Counts/ Divisions Baud Rate 2400 bps 1200 bps 2800 bps 9600 bps Print (Data Send) Automatic at Zero w Stability Automatic at Stability Manual at Stability Continuous Audible Key Tone Off On Ambient Condition (Electronic Filtering) No Filter -Very Stable Environment Limited Filter - Good Environment Moderate Filter - Poor Environment Strong Filter - Very Poor Environment See Pages 2; Installation & Set-up and Good Weighing Technique before adjusting the electronic filter settings. C8 - - 0 C8 - - 1 C8 - - 2 Model Information at Power ON On Off Standby * Factory Default Setting Page 10

CARE & MAINTENANCE ü ü ü ü ü ü Unplug the instrument from the power source wall outlet. Wear appropriate safety protection. Clean inside hood when appropriate. A damp cloth is recommend for basic cleaning. Do not use solvents on the instrument housing, sub-pan, keypad, power cord and power jack. Make sure no liquid enters the instrument housing. Handle with care to avoid damage to the weigh cell. Consult with your safety offer with any questions or concerns. ERROR MESSAGS & TROUBLESHOOTING GUIDE Error codes appear on the display for 2 seconds. The program then returns automatically to the weighing mode. Display Cause Solution No AC Power Check the AC Power Supply No Segments on the Display The Power Supply is not Plugged into the Balance Plug in the Power Supply E - E (Under Load Indicator) Err - - 0 & Err - - 1 Blown Fuse The Weight Value Exceeds the Capacity of the Balance Improper Assembly of Weigh Pan and Sub Pan Assembly Calibration Failure Replace Fuse Remove Load from the Weigh Pan Remove Weigh Pan, Sub Pan and Reassemble Environmental Factors Causing Unstable Conditions. Move to a More Suitable Location (see pages 2 and 5) Inappropriate Calibration Weight. Initiate Calibration Procedure with Correct Calibration Weight Page 11

SERVICE AND TECHNICAL SUPPORT If you have ANY questions or require technical, application or service support please contact VWR Balance Technical Support at 1-844-724-2100. Please note that VWR International, LLC and affiliates will not take back any instrument that has been exposed to biological or hazardous material contamination for replacement, credit, repair or disposal. DISPOSAL Please consider the environment when disposing of your instrument and the packing material. Please recycle all environmentally friendly waste. Please contact your local government agency, facilities manager or a commercial disposal operator on the proper disposal of the instrument and power supply. CE Compliance & Marking This instrument complies with European Standards and EC Directives: Electromagnetic Compatibility (EMC) Council Directive 89/336/EEC Applicable European Standards: Limitation of Emissions in accordance with standard EN 61326-1 Class B for residential areas. 72/23/EEC Electrical Equipment Design within Certain Voltage Limits Applicable European Standards: EN 60950 Safety Requirements for electrical equipment for measurement, control and laboratory use Part1: General requirements. Note: Modification of this instrument in any manner is the sole responsibility of the owner/operator. In addition to voiding the warranty, the owner/operator is responsible to check and if necessary correct any modifications required in accordance to the standards listed above for immunity to interference. Operating standards for this instrument are available upon request. Page 12

SPECIFICATIONS Model Capacity Readability Repeatability (s) Linearity Tare Range VWR Cat. No. VWR-64B 60g 0.1mg 0.1mg 0.2mg 0 to 60g 10204-972 VWR-124B 120g 0.1mg 0.1mg 0.2mg 0 to 110g 10204-974 VWR-214B 210g 0.1mg 0.1mg 0.2mg 0 to 210g 10204-976 VWR-203B 200g 0.001g 0.001g 0.002g 0 to 200g 10204-978 VWR-403B 400g 0.001g 0.001g 0.002g 0 to 400g 10205-028 VWR-503B 500g 0.001g 0.001g 0.002g 0 to 5-0g 10205-030 VWR-4002B 4000g 0.01g 0.01g 0.02g 0 to 4000g 10205-032 VWR-5002B 5000g 0.01g 0.01g 0.02g 0 to 5000g 10205-034 Common Specifications: Pan Size: Stabilization Time: VWR-64B, 124B, 214B, 203B, 403B & 503B VWR-4002B & 5002B Operating Temperature: Power Requirements: 90mm (3.5in) 160mm (6.3in) 3 Seconds (average) 5-40 C (41-104 F) Input 100-240VAC, 50-60 Hz, 0.6A Output 15DC, 1.0A Polarity: Inside = Negative (-) Outside = Positive (+) Unit Dimensions: (L x W x H) VWR-64B, 124B, 214B, 203B, 403B & 503B VWR-4002B & 5002B Internal Chamber Dimensions: VWR-64B, 124B, 214B, 203B, 403B & 503B Height Above Weigh Pan: Net Weight: VWR-64B, 124B, 214B, 203B, 403B & 503B VWR-64B, 124B, 214B, 203B, 403B & 503B VWR-4002B & 5002B 335 x 213.5 x 293mm (13.2 x 8.4 x 11.5in) 335 x 213.5 x 94.5mm (13 x 8.4 x 3.7in) 175 x 180 x 185mm (6.9 x 7.1 x 7.3in) 180mm (7.1in) 6.7kg (14.8lb) 5kg (11lb) Page 13

INSTRUMENT DIAGRAMS VWR-64B, 124B, 214B, 203B, 403B & 503B VWR-4002B & 5002B Page 14

The status of the information and specifications in this manual is indicated by the date given below. VWR International, LLC reserves the right to make changes to any or all of the specifications, features or design of the instruments at any time and without notice. Date: March 2015, VWR International, LLC Revision A 1.800.932.5000 www.vwr.com