ALABAMA DEPARTMENT OF TRANSPORTATION

Similar documents
SPECIAL SPECIFICATION 3289 High Friction Surface Treatment

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR HIGH FRICTION SURFACE TREATMENT. OFS:CER 1 of 5 APPR:GM:TEH: FHWA:APPR:

Standard Practice for High Friction Surface Treatment for Asphalt and Concrete Pavements AASHTO Designation: PP XX-13

SUPPLEMENTAL SPECIFICATION. High Friction Surface Treatment

Add as Section 37-6: 37-6 HIGH FRICTION SURFACE TREATMENT

CATEGORY 500 PAVING HIGH FRICTION SURFACE TREATMENT

SPECIAL SPECIFICATION 4429 Multiple-Layer Polymer Concrete Overlay

NJDOT HIGH FRICTION SURFACE TREATMENT SPECIFICATION ROBERT BLIGHT SUPERVISING ENGINEER NJDOT PAVEMENT DESIGN & TECHNOLOGY SECTION

SPECIAL SPECIFICATION 4190 Multiple-Layer Polymer Concrete Overlay

Student Services & Classroom Addition

SPECIAL SPECIFICATION 4398 Multiple-Layer Polymer Concrete Overlay

The Wonderful World of Epoxy. Presented By: Justin Morris, P.E. Khalil Hanifa, P.E.

729 - MULTI-LAYER POLYMER CONCRETE OVERLAY SECTION 729 MULTI-LAYER POLYMER CONCRETE OVERLAY

Evaluation of High Friction and Thin Overlays for Bridges and Pavements

Section 506. SLURRY SEAL

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 7. Published by

1/16 Single Broadcast Polymer Flooring System

PAVEMENT MARKING, METHYL METHACRYLATE

Dist. by: BEST MATERIALS Ph:

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 858 THIN POLYMER (EPOXY) OVERLAYS FOR STRUCTURAL SLABS.

OKLAHOMA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISIONS FOR CONCRETE SURFACE REPAIR BY SEALING

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING

Section 506 SLURRY SEAL Description. Prepare the surface and apply a properly proportioned slurry seal mixture.

KU Design Guidelines APPENDIX II PERMEABLE BITUMINOUS PAVEMENT

MICHIGAN DEPARTMENT OF TRANSPORTATION

HDX TECHNICAL SPECIFICATION

PAVER PLACED SURFACE TREATMENT

MRXL4 CR6 Surface Requirements: XNS, NS, M, S; Special Requirements: NO PART 1 : GENERAL

SPECIAL SPECIFICATION 3402 Reflective Crack Relief Interlayer (RCRI)

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

SPECIAL SPECIFICATION 5764 Anti-Graffiti Coatings

Stamped Asphalt Generic Specification

SACRAMENTO COUNTY ASPHALT RUBBER HOT MIX-GAP GRADED (ARHM-GG):

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

DECOCOLOR FLOORING SYSTEM

SUPPLEMENTAL SPECIFICATION HIGH PERFORMANCE CHIP SEAL

SPECIAL SPECIFICATION 8625 All-Weather Traffic Markings

SEALING PAVEMENT CRACKS WITH HIGH MOLECULAR WEIGHT METHACRYLATES

ITEM 25 CHIP SEAL MATERIALS 2 A. Non-Polymer Modified Asphalt Emulsion (Fog Seal) 2 B. Polymer Modified Asphalt Emulsion Binder 2

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

SECTION EPOXY TERRAZZO

Florock Seamless Flooring Systems

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

Asphalt Rubber Chip Sealing DRAFT MAINTENANCE SPECIFICATION. March 22, 2007

Stanford University Facilities Design Guidelines SECTION ASPHALT UNIT PAVING. A. ASTM C-33 Standard Specification for Concrete Aggregates.

SPECIAL SPECIFICATION 5478 Anti-Graffiti Coating

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION RESINOUS FLOORING

Section Pedestrian Traffic Coatings

VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR EMULSIFIED ASPHALT SLURRY SEAL

Section 505. CHIP SEALS

SPECIFICATIONS FOR BONDED WEARING COURSE

The specified emulsion for chip seal shall conform to the following applicable requirements:

SECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor

DIVISION 9 - FINISHES Section Coatings

LAPEER COUNTY ROAD COMMISSION ANNUAL BID SLURRY SEAL SURFACE SPECIFICATIONS

550 Surface Treatments

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

Section 502. HMA CRACK TREATMENT

EPOXY TERRAZZO 1 REV. 8/02

ASPHALTIC CONCRETE PAVING SECTION

Florock Seamless Flooring Systems

Application Specification:

SECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS

Pacific Polymers Elasto-Deck 5000MR Guide Specification

SPECIAL SPECIFICATION 5457 Anti-Graffiti Coatings

SPECIAL SPECIFICATION 4703 Repair Of Impact Damaged Prestressed Concrete Bridge Beams

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

SECTION CONTROLLED LOW STRENGTH MATERIAL

ITEM 231 CEMENT STABILIZED CRUSHED AGGREGATE BASE COURSE

SECTION LITHIUM BASED MOISTURE VAPOR CONTROL CURE SYSTEM AND FINISHING

TECHNICAL SPECIFICATION

ITEM P-609 SEAL COATS AND BITUMINOUS SURFACE TREATMENTS DESCRIPTION

Using Chip Seals & Fog Seals in Pavement Maintenance. Thomas J. Wood Research Project Supervisor MnDOT s Office of Materials & Road Research

SECTION ELASTOMERIC LIQUID FLOORING

ITEM 231 CEMENT STABILIZED CRUSHED AGGREGATE BASE COURSE

SECTION ASPHALT PAVING AND SURFACING

DIVISION 9 FINISHES Section Floor Finishes

Section 508. CHIP SEALS Description. Prepare the surface and apply the specified single chip seal, double chip seal or shoulder chip seal.

SPECIAL SPECIFICATION 3157 Cold Processed - Recycled Paving Material (RPM) for Use as Aggregate Base Course

Application Specification:

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SPECIFICATIONS FOR FOG SEAL WITH COVER AGGREGATE

SURFACINGS AND PAVEMENTS SECTION 37: BITUMINOUS SEALS 37-2 SLURRY SEAL

DIVISION 3 - CONCRETE Section Control Joint Sealers

Item 247 Flexible Base

Item 247 Flexible Base

DMS EPOXIES AND ADHESIVES

Student Services & Classroom Addition

SECTION A. American Society for Testing and Materials (ASTM):

SECTION STRUCTURAL REINFORCED POLYMER COMPOSITE PEDESTRIAN BRIDGE DECK

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

Powerdek Fleck. SECTION Resilient Athletic Flooring

- TECHNICAL SAFETY DATA SHEET

SPECIAL PROVISIONS - SP2005BOOK Page 237 JUNE 30, 2006 Last Revision 4/16/08

SECTION 633 PAVEMENT MARKERS DESCRIPTION

Transcription:

ALABAMA DEPARTMENT OF TRANSPORTATION DATE: January 9, 2014 Special Provision No. 12-0817 SUBJECT: High Friction Surface Treatments for Asphalt Pavements, Project Number 99-303-690-000-302, Jefferson County Alabama Standard Specifications, 2012 Edition, shall be amended by the addition of a new SECTION 431: SECTION 431 HIGH FRICTION SURFACE TREATMENTS FOR ASPHALT PAVEMENTS 431.01 Description. This Section shall cover the work of furnishing and applying Thin Polymer Overlays (TPO) and Methyl Methacrylate Overlays (MMA) on dense graded asphalt pavements to waterproof and provide a skid resistant riding surface. 431.02 Materials. (a) GENERAL. Materials furnished for use shall conform to the appropriate requirements of Division 800, Materials, and the requirements noted in this Section. (b) OVERLAY MATERIAL. The overlay material shall be a completely non-porous polymer or acrylic based overlay system designed for low temperature applications. The overlay system shall consist of polymer epoxy or acrylic based binder and aggregate. The overlay system shall not contain any fillers or volatile solvents. The overlay system shall meet the properties in Table 1 for TPO s and Table 2 for MMA s. Table 1: Properties of TPO s Property Requirement* Test Method Viscosity poises Class C 7-30 ASTM D 2556 Tensile Strength, min. psi. @ 7 days 2,500 AASHTO M 235 Elongation, % min. @ 7 days 30 AASHTO M 2345 Adhesive Strength, min. psi. @ 24 hours** 250 ASTM C 1583 Compressive Strength, min. psi. @ 3 hours 1,000 ASTM C 579 Compressive Strength, min. psi. @ 7 days 5,000 ASTM C 579 Water Absorption, % by wt. max. 1.0 AASHTO M 235 Durometer Hardness (shore D) 60-80 ASTM D 2240 Table 2: Properties of MMA s Property Requirement* Test Method Viscosity poises Class C 12-20 ASTM D 2556 Tensile Strength, min. psi. @ 7 days 1,500 AASHTO M 235 Elongation, % min. @ 7 days 30 AASHTO M 235 Adhesive Strength, min. psi. @ 24 hours** 250 ASTM C 1583 Compressive Strength, min. psi. @ 3 hours 1,000 ASTM C 579 Compressive Strength, min. psi. @ 7 days 2,000 ASTM C 579 Water Absorption, % by wt. max. 1.0 AASHTO M 235 Durometer Hardness (shore D) 40 75 ASTM D 2240 *Based on samples cured and tested at 73 ± 2 F ** Or 100% substrate failure

Page 2 of 5 (c) AGGREGATE. All aggregates used shall be 100 percent fractured, non-polishing, and non-friable. Aggregates shall be calcined bauxite. The physical and chemical properties of the aggregate shall meet the requirements in Table 3. Table 3: Aggregate Physical and Chemical Requirements Property Requirement Test Method Polish Stone Value 38 min. AASHTO T 279 Resistance to Degradation 20% max AASHTO T 96 Moisture Content 0.2% max AASHTO T 255 Aluminum Oxide 87% min. ASTM C 25 Aggregate Gradation % Passing by AASHTO T 27 Sieve Size No. 4 (4.75 mm) Weight 100 min. No. 6 (3.35 mm) 95 min. No. 16 (1.18 mm) 5 max (d) STORAGE AND HANDLING. Overlay materials shall be transported, stored, and handled in accordance with the manufacturer s recommendations. Overlay binder components shall be packaged in sealed containers and labeled with the type of material, the mixing ratio of the component, and any special mixing instructions. The Overlay binder component labels shall also contain brand name, name of manufacturer, lot or batch number, temperature range for storage, and expiration date. Aggregate shall be labeled and packaged in a manner that protects the aggregate from rain, moisture, and contaminants. Aggregate labels shall contain the name of the manufacturer and the location of the processing facility. All aggregates shall be stored in their original containers until the time of use. (e) OTHER REQUIREMENTS. All requirements listed in this Subarticle shall be submitted to ALDOT no less than 30 days prior to placement of the overlay. The Contractor shall submit a copy of the manufacturer s tests report or a certified test report from an independent laboratory with actual test results verifying that the materials meet all the requirements specified in Article 431.02 including Tables 1, 2, and 3. The Contractor shall submit a verification test report for each material lot or batch number to be used on ALDOT projects. The Contractor shall provide the Materials and Tests Engineer performance history data from a minimum of three projects consisting of a cumulative minimum of 10,000 square yards where the proposed overlay system has been used. The performance data must be from the last three years and demonstrate that the overlay system can achieve a friction rating of 65 FN40R when tested in accordance with AASHTO T 242, Standard Method of Test for Frictional Properties of Paved Surfaces Using a Full-Scale Tire. The performance history shall be from projects located in Alabama. If no performance history data is available from Alabama, then data from any southeastern states with similar climate conditions, such as temperature and humidity as Alabama may be accepted. A Contractor who does not meet these minimum qualifications shall be allowed to install an overlay system provided they supply the Department with written documentation from the overlay manufacturer certifying that they are approved to install the proposed overlay system. 431.03 Construction Requirements. (a) SUBMITTALS. The Contractor shall submit to the Engineer three sets of copies of product data that completely identifies the physical components, and performance characteristics of the overlay system. The submittal shall also include safety data sheets for all materials to be used. The overlay materials shall not be ordered until the product data has been accepted by the Engineer as providing an adequate description of the overlay system. The following items shall be included as a part of the product data submittal:

Page 3 of 5 - material composition (type of materials, curing agents, coloring additives, etc.) - surface preparation (special cleaning requirements, required extent of cleaning, etc.) - curing requirements (acceptable ambient temperature range, acceptable level of humidity, etc.) - application requirements and, application equipment requirements, etc. No less than 30 days prior to construction of the overlay, the Contractor shall submit to the Engineer for approval a work plan for constructing the overlay. The work plan shall include, but not be limited to, construction procedures, anticipated schedule for traffic control, overlay placement procedure, proposed pavement cleaning procedure, and test reports for each lot or batch number of each material to be used. (b) EQUIPMENT. The use of mechanical equipment for the application of the overlay will be required on projects consisting of more than two linear miles of pavement. ALDOT will allow manual application of the overlay on projects consisting of less than two linear miles of pavement and on projects deemed to be special projects by ALDOT, due to factors such as but not limited to low traffic volume. When the use of mechanical equipment is required, the overlay shall be placed using mechanical equipment capable of mixing, metering, and distributing all components of the overlay system in a continuous application as per the overlay manufacturer s specifications. The equipment shall be capable of heating and maintaining the components of the binder at a constant temperature. The equipment shall be capable of mixing the components of the binder at a constant ratio and shall be capable of consistent application rates of both the binder and the aggregate and have the capability to display and record the application rates of both materials. The use of agricultural type spreaders for the distribution of the aggregates will not be allowed when mechanical equipment for application of the overlay is required. (c) SURFACE PREPARATION. The entire area to be overlaid shall be cleaned by pressure washing to provide a surface free from dust, dirt, oil, grease, paint, and all foreign matter. The use of mild detergents in the pressure washing procedure is acceptable. The entire area to be overlaid shall be completely dried prior to the placement of the overlay by means of compressed air or hot compressed air. All traffic markings and striping shall be taped off prior to the placement of the overlay. Damaged or worn traffic markings and striping shall be removed prior to the placement of the overlay based on the recommendation of the Engineer. (d) APPLICATION OF OVERLAY. Pavement joints and cracks greater than 0.025 inches in width shall be pre-treated with the mixed TPO or MMA binder specified herein. After the binder in the pre-treated areas has gelled the installation of the overlay system may proceed. Overlays shall be placed in one layer unless otherwise recommended by the manufacturer. The layer shall consist of a layer of binder followed with a layer of aggregate. The layer of aggregate shall completely cover the binder. No exposed binder shall be visible after the placement of the aggregate. The application rate of the binder shall be 25 to 32 square feet per gallon. The application rate of the high friction aggregate shall be 12 to 15 pounds per square yard. The overlay operation shall proceed in a timely manner to ensure that mixed materials are not allowed to separate, cure, dry, be exposed or harden in such a way as to impair retention and bonding of the aggregate. The high friction aggregate shall be applied within 5 minutes (± 1 minute) of the binder application onto the pavement surface. The Contractor shall remove all excess aggregate by hand, mechanical, or suction sweeping before opening the overlaid section to traffic. The excess aggregate may be reused on other sections to be overlaid, provided the aggregate is clean, dry, and is not contaminated. Overlay applications on high speed highways such as interstates and interstate ramps will require additional sweeping three days after the completion of the installation. The Contractor shall plan and execute the work in a manner to provide at least eight hours of curing or the minimum cure time recommended by the manufacturer prior to opening the section to traffic. Walking, standing, or any form of contact or contamination with the wet uncured binder prior to the application of the aggregate without the use of spiked shoes to minimize the disturbance to the binder layer shall not be allowed and will result in that section of binder being removed and replaced at the Contractor s expense.

Page 4 of 5 The overlay manufacturer shall have a representative present at the job site at all times during placement of the overlay. The Engineer will suspend placement of the overlay system based on the advice of the manufacturer s representative or his/her own observations that the procedure or materials are no meeting specifications. Work shall not resume until the Engineer is satisfied that appropriate remedial action has been taken by the Contractor. Overlays shall not be placed when the ambient temperature is below 55 F or above 90 F and when the surface temperature is below 60 F. Placement of overlays will not be permitted when rain is forecast within 24 hours of application. (e) PERFORMANCE GUARANTEE. The overlay manufacturer shall provide ALDOT with a five year performance warranty after the application of the overlay is complete. The warranty shall be submitted to the Engineer for review. The overlay will not be accepted, and final payment made until the Contractor is notified in writing by the Engineer that the warranty is acceptable. The warranty shall include the requirement that the Manufacturer will be fully responsible for all corrective work required due to performance related issues and to restore the overlay to a serviceable condition. The warranty shall state that the overlay shall be restored to a serviceable condition by the manufacturer within sixty days of notification by ALDOT that corrective work is required. 431.04 Method of Measurement. (a) PRESSURE CLEANING. The area of the pavement pressure cleaned prior to placing the overlay will be measured in square yards computed from surface measurements taken to the nearest 0.1 of a foot {0.1 m}. (b) THIN POLYMER OVERLAY. The area acceptably overlaid will be measured in square yards computed from surface measurements taken to the nearest 0.1 of a foot {0.1 m}. (c) METHYL METHACRYLATE OVERLAY. The area acceptably overlaid will be measured in square yards computed from surface measurements taken to the nearest 0.1 of a foot {0.1 m}. 431.05 Basis of Payment. (a) UNIT PRICE COVERAGE. 1. PRESSURE CLEANING. Payment for the measured areas at the contract unit price per square yard of Pressure Cleaning will be considered full payment for all expenses associated with the blast cleaning operation. 2. THIN POLYMER OVERLAY. The accepted quantity will be paid for at the contract unit price per square yard of Thin Polymer Overlay". Layers will not be paid for individually. This price shall include all materials, procurement, handling, hauling and processing, coring for pull of testing, guarantee, and includes all equipment, tools, labor, and incidentals required to complete the work. 3. METHYL METHACRYLATE OVERLAY. The accepted quantity will be paid for at the contract unit price per square yard of Methyl Methacrylate Overlay". This price shall include all materials, procurement, handling, hauling and processing, coring for pull of testing, guarantee, and includes all equipment, tools, labor, and incidentals required to complete the work.

(b) PAYMENT WILL BE MADE UNDER ITEM NO.: 431-A Pressure Cleaning per square yard 431-B TPO Overlay per square yard 431-C MMA Overlay per square yard Special Provision No. 12-0817 Page 5 of 5