University of South Florida

Similar documents
Homework #7 Topic: Disinfection Due Tues., April 12 Assignment for 2018: Answer problem 1; then choose two of problems 4, 5, 8.

CGN 6933: Drinking Water Treatment Processes Department of Civil & Environmental Engineering University of South Florida Cunningham Spring 2013

University of South Florida Civil & Environmental Eng.

ENV 4417: WATER QUALITY AND TREATMENT. University of South Florida Civil & Environmental Eng.

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida Civil & Environmental Eng.

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida Civil & Environmental Eng.

ADVANCES IN UV TECHNOLOGY FOR 4-LOG VIRUS DISINFECTION OF GROUNDWATER. Scott Bindner OWWA Annual Conference May 2014

CEE 371 Water and Wastewater Systems

CEE 370 Environmental Engineering Principles

Disinfection: CT and Microbial Log Inactivation Calculations

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida Civil & Environmental Eng.

CEE 370 Environmental Engineering Principles. Disinfection of PWS

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida Civil & Environmental Eng.

Amherst, MA, Drinking Water System

Module 1: CHAPTER FOUR PHYSICAL PROCESSES

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida

Disinfection By-Products Reduction and SCADA Evaluation and WTP Sludge Removal System and Dewatering Facility

Department of Civil Engineering, IIT Delhi (India) CVL722 (Sem1, ) (Dr. Arun Kumar;

Effects of Environmental Factors on Nitrification Occurrence in Model Drinking Water Distribution Systems. Ng M.Y.

Investigator: July 2002

Comprehensive Approaches To Maintain Disinfection and THMs Compliance

Treatment Processes for Potable Water

Disinfection and Disinfection Byproducts (DBP)

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida

Multiple Disinfectant Barriers Within A Multiple Barrier System: A New Drinking Water Paradigm for Public Health Protection

Mitigation of Bromate during Ozonation

Water Quality Changes in the Distribution System. Module 6

REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS

Drinking Water Disinfection For Operators, Town Councils, and LSD Committees

CHLORAMINATION AND CHLORAMINE ANALYSIS

ENVE EXAM II Help Session DCC pm

CE3502. ENVIRONMENTAL MONITORING, MEASUREMENTS & DATA ANALYSIS. Inflow. Outflo

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria

University of South Florida

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida

Concentration-Time (CT) Assessment Theory and Application Examples. Daniel B. Stephens & Associates, Inc.

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida Civil & Environmental Eng.

Revised Ozone Primary Disinfection Strategy

Disinfection Overview. Module 3

CEE ENVIRONMENTAL QUALITY ENGINEERING PROBLEM SET #5

Free Chlorine Distribution System Influent Hold Study Protocol (April 2019)

UV Disinfection of Cryptosporidium for Newly Reclassified Bin 2 Systems in Illinois. Bryan Townsend UV Technology Leader B&V Water Technology Group

Module 5: Disinfection and Chlorination Answer Key

Susan Michele Teefy. Performance and Analysis of Tracer Studies to Determine Compliance with the Disinfection Requirements of the

THIS POLICY DOES NOT HAVE THE FORCE OF LAW

ENV 4001: ENVIRONMENTAL SYSTEMS ENGINEERING. University of South Florida Civil & Environmental Eng.

Let there be light! - Introduction to USEPA's UV Design Guidance Manual

Water Quality - Condensed Version 1999

Chlorination/Dechlorination: An Environmental Solution

Drinking Water Treatment Overview Filtration and Disinfection

SECTION 6.0 DESIGN CRITERIA, LAYOUTS, & HYDRAULICS

UV VALIDATION: HOW TO INTERPRET A VALIDATION REPORT AND CURRENT VALIDATION PRACTICE TRENDS

CASE STUDIES AND LEARNINGS FROM TREATMENT INCIDENTS AT RECYCLED WATER PLANTS. Renwick Chan. Department of Health, Victoria

Control of Trihalomethanes (THM s) In Wastewater. Philip S. Bober, Operations Superintendent, Wayne Township

City of Paso Robles Uses Online Monitor to Detect Low-Level of THMs in Treated Wastewater

CASCADING BENEFITS: OPTIMIZING DISINFECTION FOR CHEMICAL SAVINGS, CONTROL NITRIFICATION AND DISINFECTION BY-PRODUCTS.

Validation Studies and Beyond: Key Implementation Issues

CT TEMPLATE INSTRUCTION MANUAL

Old City, New Ideas: Peracetic Acid in Wastewater Disinfection at St. Augustine

What is Chlorine Dioxide and Why You Should Learn About It Now?

Chloramine Optimization through Proper Mixing and a Unique Chloramine Management System. John Kiernan

CE 421/521 Environmental Biotechnology - Sample Exam 2

CHAPTER 7 (Part 2) Water Processing

Chlorine Decay Modeling and Water Age Predictions

Lafayette College Department of Civil and Environmental Engineering

Lafayette College Department of Civil and Environmental Engineering

ATTACHMENT A TO THE AGREEMENT FOR ENGINEERING SERVICES. Project: Chloramine Replacement Alternative Evaluation

Civil Engineering Department

336098: DYNAMIC MODELLING AND SIMULATION OF ANAEROBIC DIGESTER FOR HIGH ORGANIC STRENGTH WASTE

Department of Civil Engineering-I.I.T. Delhi CVL723 Problem Set_2_Feb6_15

Evaluating Water Quality from Source to Tap: Using Hydraulic Modeling, Statistical Analysis and Other Tools to Improve Water Quality

Optimizing Four-Log Virus Treatment with Chemical Disinfection Relative to the Disinfectants and Disinfection Byproducts Rule

Assessing Distribution System Integrity: the case for maintaining a disinfectant residual

WEFTEC.06. ** Hatch Mott McDonald Gateway View Plaza, 1600 West Carson Street Pittsburgh, Pennsylvania. *** City of Akron Akron, Ohio

EHS SMART-Treat Onsite Moving Media Treatment System

Wastewater Reuse Solutions in Small Communities by Fixed Film Based Package Treatment and Innovation

January 2003 DRAFT - 9/30/99 1

Chlorine alternatives in Fresh Produce production ASI version 1.1

Chloramine Residual Optimization & Management:

USEPA s Pursuit of New Ambient Water Quality Criteria for Bacteriophage:

Probabilistic Modeling of Two-Stage Biological Nitrogen Removal Process: Formulation of Control Strategy for Enhanced Process Certainty

MAXIMIZING PERFORMANCE OF UV SYSTEMS FOR SMALL COMMUNITY DRINKING WATER DISINFECTION. Scott Bindner NC AWWA-NEA SPRING CONFERENCE April 13, 2015

GREATER VICTORIA DRINKING WATER:

MUNICIPAL SUPPLY DOCUMENT

Advanced Oxidation Systems

1/11/2016. Types and Characteristics of Microorganisms. Topic VI: Biological Treatment Processes. Learning Objectives:

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 631. PUBLIC WATER SUPPLY OPERATION SUBCHAPTER 1. INTRODUCTION

DW Module 23: Organic Removal Answer Key

UV DISINFECTION. Introduction to TrojanUV

Confidence Intervals for Large Sample Means

APPENDIX D SURFACE WATER TREATMENT

Oxelia OXIDATION-ENHANCED BIOLOGICALLY ACTIVE FILTRATION

Lowering The Total Cost Of Operation

Agua Consulting Inc. Engineered Water Solutions

Chloramine and Nitrification... Is There a Simple Solution?

Instructions. Disinfectants and Disinfection Byproducts Rule (DBPR) Monitoring Plan Template 6/4/03

The City of West Palm Beach (City)

Incorporating Ferrate Oxidation into Small Drinking Water Systems

Water sanitation at its best

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 631. PUBLIC WATER SUPPLY OPERATION SUBCHAPTER 1. INTRODUCTION

Transcription:

ENV 4417: WATER QUALITY & TREATMENT Fall 2015 Problem set #4 Due Tuesday, Oct. 13 University of South Florida Civil & Environmental Eng. Prof. J. A. Cunningham For 2015, answer problem 1, then problem 3 or problem 4. (Problem 3 is probably easier, but I am not sure both should be challenging.) 1. (40 pts) Ozone (O3) is a powerful disinfectant. A problem with ozone is that it decomposes relatively quickly in water; the effectiveness of ozone as a disinfectant depends partly on how fast it decomposes. Therefore, many researchers have investigated the kinetics of ozone decomposition in water. It is commonly (though not always) observed that the decomposition of ozone follows second-order kinetics. That is, the rate of ozone decomposition is given by r = k2 [O3] 2 where r is the reaction rate (mol/(l s)), k2 is a second-order rate constant, and [O3] is the molar concentration of ozone. At ph = 8 and T = 25 C, k2 is approximately 14 L/(mol s). a. Suppose the initial concentration of ozone in a batch reactor is 4 mg/l (a typical concentration for drinking water treatment). The water is at 25 C and is buffered to remain at ph = 8. How long will it take until 99% of the ozone is gone? Hint #1: watch your units. Hint #2 : You can look up second-order kinetics in a batch reactor or derive the equation from a material balance! b. Consider a case where ozone is added to water as it enters an ideal plug-flow reactor. The concentration of ozone in the influent water is 4 mg/l. The water is at 25 C and is buffered to remain at ph = 8. The system is at steady state. The plug-flow reactor has a hydraulic residence time of 30 min. Will the ozone concentration remain above 1 mg/l throughout the reactor? Show your work to justify your answer. (We want to make sure that the ozone concentration in the water does not drop below 1 mg/l because it might not be a suitable disinfectant at concentrations below that level.) Hint: a PFR is like. c. Now consider a case where ozone is added to water right before it enters an ideal completely-mixed-flow reactor (CMFR). The volumetric flow rate of the water is Q, the volume of the reactor is V, and the concentration of ozone in the influent water is CI. The system is at steady state. Write a material balance for ozone in the CMFR. d. Re-arrange the terms in your material balance to derive an equation for the concentration of ozone exiting the CMFR. Hint: there are two possible solutions to your equation from part (c), but only one of them makes physical sense, so pick that one. e. Suppose the average hydraulic residence time of a CMFR is 30 min and the influent ozone concentration is CI = 4 mg/l. The water is at 25 C and is buffered to remain at ph = 8. The system is at steady state. What will be the concentration of ozone in the reactor effluent? Hint: use your answer from part (d). p. 1/6

2. (60 pts) This problem is based on material from the textbook Water and Wastewater Engineering: Design Principles and Practice [Davis, 2011]. Suppose that you are designing a disinfection process for a city drinking water plant. The design flow rate is 18,500 m 3 /d (about 5 mgd). You have selected ozone as your primary disinfectant. Your disinfection process must achieve 3 log inactivation of Giardia, 4 log inactivation of viruses, and 2 log inactivation of Cryptosporidium, in accordance with the Safe Drinking Water Act. Assume a water temperature of 5 C. a. Look up the EPA s Ct tables to find out what Ct values are required to achieve the necessary log inactivations of the three pathogens with ozone. (I found the tables for Giardia and viruses on-line pretty easily. The table for Cryptosporidium is a bit tougher to find, but I did find it after just a few minutes of hunting.) Which pathogen will control the disinfection process? b. From a bench-scale test, we determined that we can transfer 2.0 mg/l of ozone into the water when the ph is 7.0 and the temperature is 5 C. What contact time is required? (Note that, under EPA guidelines, this contact time is t10. This means that 10% of the contactor s residence-time distribution is lower than t10 -- which implies that 90% of the contactor s residence-time distribution is greater than t10. Using t10 in the Ct calculation is intended to provide a measure of safety.) c. A hydraulic analysis of the contactor s residence-time distribution found that t10/θ = 0.65 where θ is the average (mean) hydraulic residence time. Estimate the average hydraulic residence time. d. It was observed that ozone decays according to second-order kinetics. The second-order rate constant is 3.5 L/(mol s). Determine the rate constant if we change the units to L/(mg min). The reason to do this is so that the rate constant has units consistent with your Ct values. e. Suppose that your ozone contactor can be modeled as 10 well-mixed cells in series. For instance, perhaps it is an over-under baffled contactor with 10 chambers, and each one can be considered to be well-mixed. The ozone concentration entering the first cell is 2.0 mg/l based on the test mentioned above in part (b). What will be the concentration of ozone exiting the first cell? Hint: use a material balance to determine the equation for second-order reaction kinetics in a CMFR ( like what you did on problem 1). Another hint: you know the overall hydraulic residence time of the reactor, so you can easily estimate the hydraulic residence time in each cell. Assume steady-state operation of the ozone contactor. f. Set up a spreadsheet in which you determine the concentration of ozone exiting each of the 10 cells. The effluent from cell #1 is the influent to cell #2, etc. g. Calculate the Ct value in each of the cells in the ozone contactor. Assume that t10/θ = 0.65 in each cell and use t10 when you calculate Ct. Then determine the overall Ct value. Did you meet the Ct requirement that you found in part (a)? problem 2 continues p. 2/6

2. continued h. If your contactor doesn t meet the requirement, then you can either retrofit the contactor to make it bigger a big hassle or you can try to deliver a slightly higher dose of ozone. What influent dose of ozone would enable you to meet the Ct requirement? You can find this pretty easily by trial-and-error with your spreadsheet from part (f). 3. (60 pts) The city of Eauclaire has a problem at their drinking water plant. They can t meet their treatment objective of 99% disinfection of poliovirus. In this problem, you will help them figure out why not, and what they can do about it. Assume that 99% inactivation of poliovirus requires a Ct value of 150 if using chloramines and 15 if using free chlorine. Those values apply to a batch reactor or a plugflow reactor. These are probably pretty good estimates. The plant s operating flow rate is 2.43 mgd = 383 m 3 /hr. The raw water at the plant contains 1.4 mg/l of ammonia nitrogen (i.e., 1.4 mg/l as N, not as NH3). The plant operators are dosing chlorine gas (Cl2) at a rate of 60 kg/d. a. By convention, what are the units on the Ct values reported above? b. In a batch or plug-flow reactor, what value of kt is required to give 99% inactivation of pathogens? Here k is the apparent first-order rate coefficient (base e), and t is the contact time. You can assume that Chick s law holds, i.e., that inactivation follows first-order kinetics. Hint: you are finding the kt value that gives 99% inactivation in any batch or plug-flow reactor it is not specific to the Eauclaire facility. c. Recall that the Chick-Watson model says that k = λc, i.e., the first-order rate coefficient is linearly proportional to the dose of disinfectant. The parameter λ is called the coefficient of specific lethality. Estimate λ for both free chlorine and combined chlorine. Hint: you know what kt is required for 99% inactivation (from part b), and you know what Ct is required for 99% inactivation. d. Based on the Cl2 dose rate at the plant, what should be the concentration of chlorine residual in the disinfection contactor? Do you expect this to be free chlorine or combined chlorine? Explain briefly. e. Based on the concentration you found in part (d), what would be the value of the apparent (base e) first-order rate coefficient, k, for disinfection at the Eauclaire facility? The engineers at Eauclaire were worried that maybe short-circuiting was causing their poor disinfection performance. They ran a tracer test on their chlorine contactor. They found a residence time distribution as shown in the figure on the next page. problem 3 continues p. 3/6

3. continued Residence time distribution for use in part (f) and thereafter: f. Estimate the average hydraulic residence time and the volume of the contactor. Report your estimates in units of min and m 3, respectively. g. Estimate the percentage removal of poliovirus you would expect based on the current operation at Eauclaire. Hint: use all three parts of the residence-time distribution. h. Compare the removal you found in part (g) to that which you would expect in a plug-flow reactor and in a completely-mixed flow reactor, each with the same value of k and the same average hydraulic residence time. Does Eauclaire s system behave more like a CMFR or more like a PFR? i. What do you think is Eauclaire s major problem? i.e., why can t they meet the standard of 99% removal of poliovirus? What change would you recommend in order to improve the removal of poliovirus at the Eauclaire plant? Try to be quantitative with your recommendation. 4. (60 pts) Adapted from a problem originally written by Prof Paul Roberts of Stanford University. A water treatment plant is having difficulties meeting its coliform requirement (< 2 coliforms per 100 ml). They are treating a surface water supply with 10 3 coliforms per 100 ml. Ammonia is negligible. The volume of the chlorine contact tank is 1000 m 3 and the flow is 100 m 3 /min. At the chlorine dose currently used (2 mg/l Cl2), a residual of 1 mg/l is obtained. However, even with this chlorine residual, approximately 10 coliforms/100 ml remain in the effluent. p. 4/6

4. continued a. You are called in to determine the chlorine residual needed to assure less than 2 coliforms/100 ml in the finished water. You conduct a batch disinfection study at two dosage levels, with the following results: Experiment A B Cl2 Dose (mg/l) 2 5 Cl2 Residual (mg/l) 1 3 log10(n0/n) t = 1 min 0.5 1.0 t = 2 min 1.0 2.0 t = 5 min 2.5 5.0 t = 10 min 5.0 Interpret the data using Chick's law and report the rate constants for cases A and B. b. The treatment plant manager doesn't believe your data. She tells you: Your data from Experiment A show that I should have 5 log-kills after 10 minutes at a chlorine residual of 1 mg/l. I know I have a residual of 1 mg/l in my chlorine contactor, and my average hydraulic residence time is 10 min. Therefore, I should easily be achieving the effluent requirement at the present dosage. Your data must be wrong! What other possible explanation can you suggest? How would you test its validity? (Hint: read parts c and d, below.) c. The manager throws you out of the office and begins to dose at 5 mg/l Cl2, which yields a residual of 3 mg/l (as in Experiment B). Two months later, she calls you back. Even at the higher dose and the higher residual, she still finds coliforms in about half of the effluent samples. Furthermore, she is now receiving 50 complaints per week from customers regarding the taste and odor of the water. ( and I worry to think about the higher DBP formation, too!!) She now agrees with your suggestion in part (b) above, and conducts your proposed study. The results are shown in the table on the following page. d. What amount of tracer (mass) did you have to add (as a pulse) to get these results? e. What are the average hydraulic residence times of the unbaffled tank and the baffled tank? Based only on the average hydraulic residence time, which reactor (baffled or unbaffled) would you expect to offer better disinfection? problem 4 continues p. 5/6

4. continued Tracer Concentration (mg/l) Time (min) Unbaffled Tank Baffled Tank 1 0.02 0.01 3 0.1 0.03 5 0.16 0.06 7 0.16 0.12 9 0.13 0.28 11 0.1 0.28 13 0.064 0.12 15 0.048 0.06 17 0.036 0.03 19 0.03 0.01 25 0.016 0.005 35 0.01 45 0.005 f. What effluent coliform concentration do you calculate for the unbaffled and baffled reactors based on the data in parts (a) and (c)? Calculate for both residual levels, 1 mg/l Cl2 and 3 mg/l Cl2. Do the calculated results for the unbaffled reactor agree with the plant manager's experience? What system would you recommend to meet the standard? g. Was your expectation from part (e) met? Why or why not? Comment briefly on the importance of residence-time distribution during disinfection. p. 6/6