Automated and Quantitative Analysis of Biologics

Similar documents
Automated and quantitative analysis of biologics

Automated and quantitative

"VUPNBUFE BOE RVBOUJUBUJWF

Unified Workflow for Monoclonal Antibody Charge Heterogeneity, Purity, and Molecular Weight Analysis

Analysis of Monoclonal Antibody Charge Variants by Capillary Zone Electrophoresis

PA 800 plus Catalog. Systems/Software

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

More Samples. Better Decisions Faster.

High-Throughput Glycan Screening to Remove Biopharmaceutical Development Bottlenecks

Answers, Simple and Streamlined. Solutions for Biotherapeutic Intact Mass Analysis

Repeatability of C100ht Biologics Analyzer, for High Throughput Glycan Screening

Simplifying CE-SDS Data Processing

Application Note. Biopharm. Author. Abstract. Christian Wenz Agilent Technologies, Inc. Waldbronn, Germany

High Resolution Separation and Quantitation of Charged and Polar Analytes

LabChip GXII: Antibody Analysis

HPCE-5 2. A Revolution in Capillary Electrophoresis. High Performance Capillary Electrophoresis

Optimization of cief to Resolve Challenging MAb Samples of Clinical Immunodiagnostic Relevance

The Importance of Temperature Control in Capillary Electrophoresis of Carbohydrates

Assay of IgG Purity and Heterogeneity using High-Resolution Sodium Dodecyl Sulfate Capillary Gel Electrophoresis

Separation of Recombinant Human Erythropoietin (rhepo) using the European Pharmacopoeia Method on the PA 800 plus Pharmaceutical Analysis System

Rediscover the Strengths of Your PA 800 Plus - A Multi-Attribute Protein Analyzer

Impurity Detection with a New Light Emitting Diode Induced Fluorescence Detector Coupled to the Agilent 7100 Capillary Electrophoresis System

Improving the Detection Limits for Highly Basic Neuropeptides Using CESI-MS

Capillary Electrophoresis of Proteins

One-stop cief and CE-SDS. One-day method dev. Results in a snap. FDA, PDQ.

Automating the C100ht Biologics Analyzer Sample Preparation on a Biomek i5 Liquid Handler Platform

deltadot ANTIBODY ANALYSIS Application Note: Antibodies using LABEL FREE INTRINSIC IMAGING LONDON United Kingdom

See More, Much More Clearly

Comparison of Different Brands of Carrier Ampholytes for Monoclonal Antibody Charge Heterogeneity Analysis by Capillary Isoelectric Focusing

A Robust cief Method: Intermediate Precision for the ph 5-7 Range

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

Capillary Electrophoresis in Quality Control PART II: CE-SDS: Method Development and Robustness

Table 1: CE-MS: Unexploited Opportunities in Process Development?

Proteomics PA 800 (Beckman) ProteomeLab System (Detect Instrument Picture to Jump to that section of SOP)

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

LabChip 90 System with DataViewer Software

SCIEX OS Software One Touch Productivity

OptiFlow Quant Solution for High-Sensitivity Quantitation

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

Fully Automated C100HT Biologics Analyzer Sample Preparation on a Biomek i5 Multichannel Workstation

This is not unique to CE. It took for instance about 25 years for HPLC to establish itself properly in the pharmaceutical industry.

Streamlined and Complete LC-MS Workflow for MAM

Knock! Knock! Who s there? Maurice Who? SungAe Suhr Park, Mee Ko, Eleanor Le, Janice Chen Amgen Inc.

Assessing Glycosimilarity of Biotherapeutics

Made for Routine Food, Environment, and Forensic Testing. The X500R QTOF System

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

CE as an analytical tool in industrial biotechnology. David Goodall, CSO, Paraytec Ltd. 14 November Act P x

Comprehensive characterization of three IgG forms using CESI-MS

quantitate host cell DNA with high sensitivity and throughput resdnaseq Host Cell DNA Quantitation Systems: CHO, E.

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Isotopic Resolution of Chromatographically Separated IdeS Subunits Using the X500B QTOF System

HPCE-5 2. Realising the potential of Capillary Electrophoresis. Why is the HPCE-512 so much better?

TECHNICAL INFORMATION

E-Coli Cell Lysate By High Performance Capillary Electrophoresis

Microfluidic Assays for High Throughput Screening of Protein Quality in Bioprocess Development

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Analysis of Protein Biopharmaceuticals

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

IgG Purity and Heterogeneity Assay Kit For the PA 800 Plus Pharmaceutical Analysis System. Application Guide

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

High-Resolution Separation of Intact Monoclonal Antibody Isoforms

LIFluor EnhanCE. for use with dsdna 1000 and dsdna 20,000 Kits

ph gradient analysis of IgG1 therapeutic monoclonal antibodies using a 5 µm WCX column

Chromatography column for therapeutic protein analysis

Analysis of Intact Monoclonal Antibodies Using an M3 MicroLC with the TripleTOF 6600

The power of precision. cief pi Marker Kit

Optimization Approaches in the Routine Analysis of Monoclonal Antibodies by Capillary Electrophoresis

Biotherapeutic Peptide Mapping Information Dependent Acquisition (IDA) Method

autoflex max Practical Power, Maximum Utility Innovation with Integrity MALDI-TOF MS

CX-1 ph Gradient Buffer

Separation Science Built for Biopharma

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Fast Glycan Sequencing Using a Fully Automated Carbohydrate Sequencer

Capillary Electrophoresis Compendial Applications

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

NISTmAb characterization with a high-performance RP chromatography column

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

ssdna 100-R Kit Care and Use Instructions AG June 2015

An Industry Perspective on Established Conditions in the Analytical Control System. Christof Finkler, F. Hoffmann-La Roche

Chapter 2 Coated Capillaries for CE-MS of Therapeutic Protein

Agilent CE and CE/MS Solutions FLEXIBILITY AND RELIABILITY TO AMPLIFY YOUR FINDINGS

Rapid Identification and Characterization of Biologics using CESI 8000-TripleTOF MS Platform

Developing Quantitative UPLC Assays with UV

Columns for Biomolecules BioLC Column Lines

Charge Variant Assessment of Nanobodies at the Intact Level by CESI-MS

Dynex DSX 4-Plate ELISA Processing System. Modular Flexible Reliable A Perfect Combination.

Biotherapeutic Non-Reduced Peptide Mapping

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

Characterization of intact monoclonal antibody with microfluidic chip electrophoresis mass spectrometry

Applications. Capillary Electrophoresis. Cell Lysate Analysis. Analysis of E. Coli Lysate. Technology

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Agilent AssayMAP Platform BIOLOGICS SAMPLE PREPARATION INTELLIGENTLY AUTOMATED

Agilent 2100 Bioanalyzer System SECURE EXPERIMENTAL SUCCESS

Monoclonal Antibody Charge Variants Identification by Fully Automated Capillary Isoelectric Focusing Mass Spectrometry

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

NGS Sample QC with the Agilent 2200 TapeStation. Rainer Nitsche Application Engineer Agilent Technologies, Inc.

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Transcription:

PA 800 PLUS PHARMACEUTICAL ANALYSIS SYSTEM Automated and Quantitative Analysis of Biologics PA 800 PLUS PHARMACEUTICAL ANALYSIS SYSTEM For Research Use Only. Not for use in diagnostic procedures.

Flexibility for Method Development & Simplicity for Routine Operation Therapeutic proteins make up a rapidly growing segment of global pharmaceutical production. These complex molecules require accurate characterization of product purity, heterogeneity and identity. This includes data regarding their stability, shelf life and related manufacturing processes. Research Analysts handling therapeutic proteins need: Automated, qualitative and quantitative analysis Simplified functionality and maximum operational efficiency Limitless flexibility for method development Simple enough for routine use yet includes system controls for full method optimization Robust, validated applications that can be transferred globally The PA 800 Plus Pharmaceutical Analysis System enables all of these needs, providing a robust analytical platform with easy-to-use software for the development and quality control of therapeutic proteins. Automated and quantitative analysis of biologics The PA 800 Plus Pharmaceutical Analysis System has been adopted by many companies in the biopharmaceutical industry and global regulatory organizations. 1 The assays we pioneered for purity and heterogeneity determination for use on this platform are referenced in pharmacopoeial methods. Analysts benefit from quantitative, qualitative, and automated protein purity, charge isoform distribution, and glycan analyses. The PA 800 Plus assays below have proven portability and enhance the overall system utility in global multi-user, multi-instrument organizations. High-resolution SDS gel protein separations with up to 4 orders of magnitude in detection Advanced capillary isoelectric focusing (cief) and high speed capillary zone electrophoresis (CZE) for charge heterogeneity analysis Carbohydrate profiling for assessment of glycoprotein microheterogeneity 1. A Series of Collaborations between Various Pharmaceutical Companies and Regulatory Authorities Concerning the Analysis of Biomolecules Using Capillary Electrophoresis. Chromatographia 2006, 64, September No. 5/6). Evaluation of capillary zone electrophoresis for charge heterogeneity testing of monoclonal antibodies Journal of Chromatography B, 983 984 (2015) 101 110 Multi-Site Nglycan mapping study 1: Capillary electrophoresis laser induced fluorescence, mabs. Volume 6, Issue 6, 2014 Intercompany Study to Evaluate the Robustness of Capillary Isoelectric Focusing Technology for the Analysis of Monoclonal Antibodies. Chromatographia (2011) 73:1137 1144

Simplified operation on a robust platform enhances operational efficiency: Specialized software quickly guides routine users from set-up through results Ready-to-use cartridge for purity assessment ensures data consistency and ease of use Innovations in system design provide dependable operation and durability, with minimal maintenance Modular UV, photodiode array and laser-induced fluorescence detectors can be easily interchanged Methods can be locked down in Analytical Development for routine use in QA/QC The PA 800 Plus Pharmaceutical Analysis System

Quantitative Protein Purity Analysis with SDS-Gel Capillary Electrophoresis Understanding the Separation Matrix It s important to understand the components making up your CE separation matrix. Our replaceable CE-SDS gel was developed for use in the IgG assay on the PA 800 Plus. The core elements include a dextran polymer in tris borate buffer High-resolution, quantitative data The PA 800 Plus Pharmaceutical Analysis System automates size separation of proteins and provides high-resolution, quantitative data. The CE SDS-gel application has become the gold standard for protein purity analysis in biopharmaceutical laboratories, replacing manual, low resolution SDS-PAGE. Denatured proteins can be reduced or left intact for separation and subsequent analysis. Replaceable SDS-gel 2 consists of a polymer matrix that allows for: High-resolution separation capability Quantitative and automated separation of proteins from 10-225kD Sensitivity equivalent to silver-stained gels when using laser-induced fluorescence (LIF) detection Modular UV/vis and LIF detection allow up to 4 logs of detection 1. A Series of Collaborations between Various Pharmaceutical Companies and Regulatory Authorities Concerning the Analysis of Biomolecules Using Capillary Electrophoresis. Chromatographia 2006, 64, September (No. 5/6). 2. See US Patent # US7,381,317. Automating the process of gel replacement is disclosed in US Patent # USRE37,606. IgG Purity and Heterogeneity Assay The PA 800 Plus IgG Purity and Heterogeneity Assay Kit (p/n A10663) was designed in collaboration with biopharmaceutical analysts developing and manufacturing therapeutic MAb molecules. Assay methodology involves heat denaturation of IgG in the presence of SDS, followed by size separation using high-resolution capillary gel electrophoresis technology. Impurity detection to 0.01% using LIF and 3 orders of magnitude when using UV detection Repeatability of IgG mobility <1% RSD The IgG assay on the PA 800 Plus features an internal system suitability control consisting of an IgG control standard with a designated quantity of non-glycosylated heavy chain to test both the resolution and quantitation suitability of the assay prior to running unknowns. The United States Pharmacopeial Convention has included IgG Purity and Heterogeneity analysis in Chapter <129> - Analytical Procedures for Recombinant Therapeutic Antibodies (source: United States Pharmacopeial Convention; usp.org) ph 8.0 8.3, Glycerol added to increase the molecular size separation range, and EDTA to minimize protein oxidation brought about by metal ion chelation. This formulation has proven 1 to be an excellent matrix in which to resolve even the smallest difference in Analysis of both the reduced and non-reduced IgG Suitability standard using the IgG purity method. Peak 1: Internal standard (10 kda); 2: Light Chain (L); 3: NG heavy chain; 4: Heavy chain (H); 6; Heavy-heavy chain (2H); 7: 2 heavy 1 light chain (2H1L); 8 Reduced IgG Non-Reduced IgG 1 2 2 3 4 6 8 7 9 migration time for an increased number of therapeutic proteins.

More information on the SDS-gel application is available in the following application bulletin: Assay of IgG Purity and Heterogeneity Using High-Resolution Sodium Dodecyl Sulfate Capillary Gel Electrophoresis (AIB A-1973A). The table below summarizes the results of 18 consecutive SDS-gel analyses of a reduced mouse IgG standard. The relative standard deviation (% RSD) of both the light chain and heavy chain mobility was <1%, while the quantitative determination of the % light chain (LC), heavy chain (HC) and non-glycosylated heavy chain (NGHC) was also <1%. Resolution between the NGHC and HC was >1. Injection %Corrected Area Reproducibility Resolution Mobility Reproducibility ID LC NG HC NG/HC LC HC Injection1 27.90 5.95 49.89 1.42-0.00004450-0.00003467 Injection2 27.94 5.96 49.87 1.41-0.00004450-0.00003465 Injection3 27.90 5.93 49.94 1.44-0.00004450-0.00003464 Injection4 27.96 5.94 49.87 1.41-0.00004448-0.00003466 Injection5 27.91 5.93 49.81 1.41-0.00004452-0.00003471 Injection6 27.96 5.92 49.87 1.41-0.00004451-0.00003468 Injection7 28.01 5.90 49.86 1.40-0.00004451-0.00003467 Injection8 27.90 5.93 49.98 1.40-0.00004450-0.00003469 Injection9 27.98 5.95 49.84 1.43-0.00004454-0.00003472 Injection10 27.94 5.93 49.87 1.43-0.00004453-0.00003474 Injection11 28.00 5.93 49.80 1.40-0.00004456-0.00003480 Injection12 28.00 5.92 49.76 1.40-0.00004458-0.00003482 Injection13 27.97 5.93 49.85 1.40-0.00004463-0.00003494 Injection14 28.04 5.90 49.82 1.40-0.00004466-0.00003498 Injection15 28.01 5.92 49.76 1.43-0.00004468-0.00003500 Injection16 28.03 5.91 49.73 1.43-0.00004466-0.00003500 Injection17 28.04 5.91 49.79 1.42-0.00004470-0.00003504 Injection18 28.13 5.87 49.70 1.42-0.00004469-0.00003506 Min: 27.90 5.87 49.70 1.40-0.00004470-0.00003506 Max: 28.13 5.96 49.98 1.44-0.00004448-0.00003464 Mean: 27.98 5.92 49.83 1.41-0.00004457-0.00003480 Std Dev: 0.06 0.02 0.07 0.01 0.00000008 0.00000015 %RSD: 0.22 0.36 0.14 0.95 0.17 0.44 This SDS-gel based method has been successfully implemented by different organizations in different locations with high precision. The portability of the IgG Purity and Heterogeneity Assay was demonstrated in a study featuring multiple biopharmaceutical companies. 2 This exercise supports and endorses the increased application of CE methodology within both development and QC laboratories within biopharmaceutical companies. 2 2. A Series of Collaborations between Various Pharmaceutical Companies and Regulatory Authorities Concerning the Analysis of Biomolecules Using Capillary Electrophoresis. Chromatographia 2006, 64, September (No. 5/6).

High Throughput and Ultra High Resolution Options CZE appears as a new powerful platform technology for the charge heterogeneity testing of antibodies in the pharmaceutical industry. 3 High precision and quantitative separations Accurate determination of a protein s charge heterogeneity helps establish identity and stability. Capillary Isoelectric Focusing (cief) is a powerful technique that allows quantitative analysis of proteins separated by isoelectric point (pi). Capillary Zone Electrophoresis (CZE) provides high speed charge heterogeneity analysis using simple sample preparation. The PA 800 Plus Pharmaceutical Analysis System automates advanced cief and CZE technologies to achieve high precision and quantitative technologies separations. Use of optimized methods and synthetic pi markers in cief attains a high level of precision in pi cief estimation and direct isoform quantitation. Comparison between cief and CZE of a therapeutic MAb. Whereas cief provides ultra-high resolution between charge isoforms, CZE combines less complex sample preparation and faster separations without significant loss in resolution. Application information bulletins describing the advanced cief and CZE methods in detail: Identification of System Parameters Critical for High Performance cief (AIB A-11634A) A Robust cief Method: Intermediate Precision for the ph 5-7 Range (AIB A-12015A) High-Resolution cief of Therapeutic Monoclonal Antibodies: A Platform Method Covering ph 4-10 (AIB A-12026A) Analysis of Monoclonal Antibody Charge Variants by CZE (IB-17031A) In cief, a mixture of sample and ampholyte is introduced into a capillary and subjected to electrophoretic separation. In this process, a ph gradient through which analytes migrate to their respective pi is formed. Comprehensive optimization of multiple assay parameters has been performed. Requiring less sample preparation than cief, CZE generates charge isoform heterogeneity data fast and with very high resolution CZE = mobility-based - charge - hydrodynamic size cief = charge-based

and reproducibility. Inter-company collaborative studies illustrating assay robustness and portability have been performed in the biopharmaceutical industry for both cief 1 and CZE 2. Successful transfer and implementation of characterization assays between laboratories is based on a method s ability to minimize environmental and operator variability. An important indicator of the necessary robustness is intermediate precision. Performing advanced cief and CZE on the PA 800 Plus system provides: Repeatability of IgG mobility <1% RSD Detection of impurities below 0.1% The PA 800 Plus UV/Vis Detection Module provides absorbance spectroscopy in the UV-visible region. Commonly used exclusion filters at 200 nm, 214 nm, 254 nm and 280 nm are provided to increase analyte specificity. The table summarizes the results of a cief intermediate precision study on a therapeutic IgG containing 7 isoforms. This MAb was separated in triplicate on two different instruments using three different lots of neutral capillary and reagents on 6 different days. Isoforms were grouped as acidic, main or basic and then analyzed. The coefficient of variance (% CV) for each of the 7 peaks was <1%, while the quantitative determination of the isoform group % composition was < 3%. The main isoform group % composition was < 3%. References for above referenced publications: (1) Salas-Solano O et al. (2011) Intercompany Study to Evaluate the Robustness of Capillary Isoelectric Focusing Technology for the Analysis of Monoclonal Antibodies. Chromatographia. 73:1137-1144 (2) Moritz B et al. J Chromatography B. article in press. (3) B. Moritz et al. / J. Chromatogr. B 983 984 (2015) 101 110 0.45 cief Peptide Marker Kits feature synthetic peptides. The combination of the advanced cief methods, synthetic pi markers and the PA 800 Plus system results in cief separations with a high level of precision for pi determination and isoform quantitation of your sample. n = 25 Estimated pl Peaks Average Std Dev % CV A 8.31 0.00 0.06% B 8.18 0.01 0.07% C 8.13 0.01 0.07% D 8.07 0.01 0.07% E 8.01 0.01 0.07% F 7.90 0.01 0.07% G 7.78 0.00 0.05% AU 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 Instrument B/Cap. Lot 3/Day 6 Instrument A/Cap. Lot 3/Day 5 Instrument B/Cap. Lot 3/Day 5 Instrument A/Cap. Lot 2/Day 4 Instrument B/Cap. Lot 2/Day 3 Instrument A/Cap. Lot 1/Day 3 Instrument A/Cap. Lot 1/Day 2 Instrument A/Cap. Lot 1/Day 1 0.00 22.0 22.5 23.0 23.5 24.0 24.5 25.0 25.5 26.0 27.0 27.5 28.0 28.5 29.0 29.5 30.0 Minutes Intermediate Precision data illustrating reproducibility of uncorrected raw migration time data. Isoform Group Percent Composition Group Average Std Dev % CV Basic 30.97% 0.67% 2.17% Main 45.01% 0.45% 0.99% Acidic 24.02% 0.60% 2.50%

Fast, Reproducible, High Resolution Glycan Analysis Simplified processing Glycosylation on a protein is an important posttranslational modification that can affect its function, clearance and stability. The PA 800 Plus Pharmaceutical Analysis System simplifies the complex process of profiling carbohydrates associated with glycoproteins. By providing specific and accurate quantitation of glycosylation levels, differences in glycoform quantities and distribution can be determined. Key benefits to carbohydrate profiling using capillary electrophoresis include: Quantitation of N-linked oligosaccharides 1 High-resolution separation methods capable of differentiating positional isomers Validated methodology developed for routine use environments Data can be used with Glycobase for easy identification of glycan species. Oligosaccharide analysis Following endonuclease cleavage from the protein, oligosaccharides are specifically labeled with amino-pyrene-trisulfonic acid (APTS) by reductive amination. This analysis is performed directly from the glycoprotein hydrolysate. With APTS derivatization and LIF detection, each sugar yields the same detector response, so their relative quantities can be directly compared. (1) B. Moritz et al. / J. Chromatogr. B 983 984 (2015) 101 110 Rapid Glycan Analysis: 1 hour sample prep 3 min. separation per sample Data in <6 hours for 96 samples Glucose standard ladder 1 2 3 4 5 IgG N-glycans Standard glycan mix: G0, G0-F, G1, G1-F, G1', G1'-F, G2, G2-F 1 2 3 4 5 Migration Time (minutes)

Oligosaccharide distribution associated with a protein yields a fingerprint that can be used in protein identification. The PA 800 Plus provides easy, quantitative and robust determination of protein microheterogeneity, with a typical analysis time of less than 15 minutes and with method optimization as fast as 3 minutes per separation without significant loss in resolution. The Carbohydrate Labeling and Analysis Assay is described in more detail in the following application bulletin: CE Separation of N-Linked Oligosaccharides Released from Recombinant Monoclonal Antibody (AIB A-1986A) View the video: Sample preparation of mab N-glycans using Magnetic Bead Technology and CE-LIF. More information is available in the following application bulletin: Separation of Fucosylated, non-fucosylated, and Complex Carbohydrates Associated with Monoclonal Antibodies using Capillary Electrophoresis (AIB-15285A) The applied CE-LIF method for the analysis of glycans provides reliable intra- and inter-laboratory results across laboratories and it is therefore a robust tool for N-glycan analysis that can confidently be applied on its own or as an orthogonal technique to other existing methods. The United States Pharmacopeial Convention has included glycan analysis by CE for determination of IgG Microheterogeneity analysis in Chapter <129> Analytical Procedures for Recombinant Therapeutic Antibodies. (source: United States Pharmacopeial Convention; usp.org)

Software as easy as 1, 2, 3 1 Select application 2 Load samples and application reagents Incorporating tools to enable 21CFR part 11 compliance, the PA 800 Plus software quickly guides users from set-up through routine system operation. Large icons provide intuitive guidance for navigation, while on-screen cues indicate system progress at a glance. Insightful Help menus and descriptive system prompts further simplify operator learning, making transfer of PA 800 Plus technology to other analysts easier. Ultimately, using PA 800 Plus software is as easy as 1, 2, 3.

Use the Help and video menu as needed. 3 Acquire data PA 800 Plus software features include: Automated sequence table and reagent calculations Validated applications for SDS-gel, cief and carbohydrate analysis Enhanced Help menu and instructional videos Technical controls enable regulatory compliance On-screen prompts for monitoring system events Advanced reporting capability Increased workspace

A Robust Solution for Demanding Research Requirements The PA 800 Plus offers dependable, accurate determination of protein purity, heterogeneity and identity. Close collaboration with biopharmaceutical development and QC groups experienced in biologics characterization helped create assays which address analytical challenges. Automated Sample Introduction The PA 800 Plus system offers fully automated methods and extended sample-handling capability for walkaway operation. Sampling can be performed using 1.8 ml universal vials, 96-well plates and micro vials. Precision-molded polymethylpentene universal vials accommodate run buffer, sample and micro vials. Sample Temperature Control Sample temperature control, independent from buffers, enables users to maintain molecular stability when working with temperature-labile protein species. The sample temperature can be between 4-60 C. The universal vial and cap design prevents the capillary and electrode from physically interacting with the caps, ultimately allowing for a robust, clean sample interface. Temperature Control of the Separation Capillary Efficient separations in CE rely on precise regulation of the capillary temperature to manage Joule heating within the capillary. Proper temperature control plays an important role in the repeatability of SDS-gel, cief and carbohydrate analysis. The PA 800 Plus uses recirculating liquid coolant to provide effective heat dissipation when performing assays on the system. Capillaries are housed in cartridges facilitating both temperature control and easy exchange of capillary dimensions and surfaces (see application bulletin T1823ab). Capillary temperature can be regulated between 15-60 C. nanovial Multiple injections from 5 μl sample amount can be performed with the nanovial.

Multiple Modes of Sample Introduction and Separation The PA 800 Plus offers electrokinetic, pressure and vacuum injection of samples. Additionally, injection from either end of the capillary allows both ultrafast and high-resolution analyses. Separations can be adjusted by varying voltage, current, pressure and vacuum. The combination of voltage and pressure in the SDS-gel assay ensures the gel buffer stays free of air bubbles which can be generated from gel outgassing. Variable Pressure and Vacuum The PA 800 Plus operates with all common rinsing protocols, regulating them with a pressure-handling capability of -5 to 100 p.s.i. Capillary conditioning is accomplished by moving specific volumes of electrolytes, gels, regenerants and cleaning solutions through the capillary. Gel buffers are quickly and efficiently pumped into the capillary. Ready-to-Use Capillary Cartridges CE-SDS can be performed using factory manufactured cartridges, ready-to-use with bare fused-silica capillaries. Ready-to-use cartridges ensure precision cut ends and alignment of capillary windows with the detection path, resulting in consistency of your separations. Capillary cartridge with circulating coolant Versatile Modular Detection Capability The PA 800 Plus offers precise, real-time analysis for a variety of assays, because it integrates UV, photodiode array, and LIF detection capabilities in one unit. UV detection is important when using photosensitive capillary surfaces. Photodiode array detection between 190 and 600 nm allows for baseline subtraction and spectral wavelength analyses. A 488 nm solid state laser and laser-induced fluorescence (LIF) detector permits high-sensitivity analysis of labeled molecular species. CE-MS Ready For high sensitivity applications we recommend the CESI 8000 Plus High Performance Separation - ESI Module. With the CESI 8000, stable spray is achieved at ultra-low flow rates (<10 nl/min) resulting in the following benefits: Ion suppression bias is virtually eliminated Ionization efficiency maximized giving an overall increase in sensitivity With optional detectors the CESI 8000 Plus has all the abilities of the PA 800 Plus as well as MS connectivity. No detectable sample carryover The integrated, solid state 488 nm laser reduces the overall system footprint.

Reagents Supplies and Accessories Supplies and Resources Purity SDS-Gel Multipack (4 bottles) A30341 Universal Vials A62251 200 μl Microvials (pkg of 100) 144709 Items can be ordered at IgG Purity and Heterogeneity Assay A10663 10 kd Protein Standard A26487 Universal Vial Caps Electrode Replacement Kit A62250 A47775 sciex.com/contact-us IgG Control Standard (3-pack) 391734 Bare Fused Silica Capillaries (3) 338451 Vial Cap Opener Buffer Vial Tray (36 vials) A95348 A58254 Buffer Vial Tray (48 vials) A58255 Purity/Sizing SDS-MW Assay Kit/ Purity/Sizing 390953 MW Sizing Standard Glycan Carbohydrate Labeling and Analysis Assay A22196 477600 N-CHO Capillary 477601 nanovial 100 vials Cartridge Assembly, 30 cm Capillary 5043467 A11147 Blank Cartridge Assembly Kit 144738 Cartridge Rebuilding Kit 144645 Cartridge Tubing Kit 144689 Capillary Coolant (450 ml) 359976 Pre-assembled Cartridge (includes bare fused-silica capillary) A55625 Charge Heterogeneity cief Peptide Marker Kit (pi Marker Kit) A58481 Neutral Capillary 477441 Advanced cief Starter Kit A80976

System Specifications Dimensions: Height: 29.2 in (74.2 cm) Door Open: 38.8 in (98.6 cm) Width: 25 in (63.5 cm) Depth: 28.4 in (72.1 cm) Weight (uncrated): 188 lbs (85.3 kg) (includes photodiode array detection) Electrical Requirements: Voltage: 100-240 V; 50/60 Hz Voltage Range: 1 to 30 kv programmable at 0.1 kv increments Current Range: 3 to 300 μa programmable at 0.1 μa increments System Capacity Sample Trays: 2 x 96-well plates 2 x 48 universal vials 2 x 48 0.2 ml microvials Buffer Tray: 2 x 36 universal vials Detection Capability: UV/Vis 200, 214, 254, 280 nm standard filter 190-600 nm (custom filter option) Diode Array 190-600 nm (programmable) 0.5-32 Hz scan collection frequency (programmable) Laser Induced Fluorescence (LIF) 300-700 nm excitation range 350-750 nm emission range 0-1000 RFU Ordering information A66528 PA 800 Plus Pharmaceutical Analysis System Includes separation module with UV, photodiode array and LIF detection; system controller with PA 800 Plus software; system startup kit and reagents A66527 PA 800S Plus Pharmaceutical Analysis System Includes separation module with photodiode array detection; system controller with PA 800 Plus software; system startup kit and reagents Pressure Delivery Range: -5 to +100 psi Source Lasers with 3 mw Power Output: 488 nm solid-state laser (included in A66528) Sample Temperature Control: 4-60 C Capillary Temperature Control:: 15-60 C

Your Success is Our Success We take it personally As a SCIEX customer you have access to a world-class customer support organization. Wherever you are, we re there with you as a trusted partner to answer questions, provide solutions, and maximize lab productivity. Our customer support organization has access to the latest product updates, software revisions, methods and repair procedures to make sure that you stay on top of your game. Analis sa/nv Belgium Suarlée Namur Tel 081 25 50 50 Sint-Denijs-Westrem Tel 09 243 77 10 www.analis.be lifescience@analis.be When you have questions, we have answers. Learn more at sciex.com/customersupport, or locate your local account representative at sciex.com/contactus AB Sciex is doing business as SCIEX. 2016 AB Sciex. For Research Use Only. Not for use in diagnostic procedures. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. RUO-MKT-03-1913-B 06/2016 Headquarters 500 Old Connecticut Path Framingham, MA 01701 USA Phone 508-383-7700 sciex.com International Sales For our office locations please call the division headquarters or refer to our website at sciex.com/offices