Applications of deltadot s Label Free Intrinsic Imaging Technology. March 2012

Similar documents
HPCE-5 2. Realising the potential of Capillary Electrophoresis. Why is the HPCE-512 so much better?

HPCE-5 2. A Revolution in Capillary Electrophoresis. High Performance Capillary Electrophoresis

deltadot ANTIBODY ANALYSIS Application Note: Antibodies using LABEL FREE INTRINSIC IMAGING LONDON United Kingdom

E-Coli Cell Lysate By High Performance Capillary Electrophoresis

Applications. Capillary Electrophoresis. Cell Lysate Analysis. Analysis of E. Coli Lysate. Technology

deltadot

CSE Separation of Cancer Cell Lysate

Analysis of Monoclonal Antibody Charge Variants by Capillary Zone Electrophoresis

LabChip GXII: Antibody Analysis

Separation of Recombinant Human Erythropoietin (rhepo) using the European Pharmacopoeia Method on the PA 800 plus Pharmaceutical Analysis System

PA 800 plus Catalog. Systems/Software

Impurity Detection with a New Light Emitting Diode Induced Fluorescence Detector Coupled to the Agilent 7100 Capillary Electrophoresis System

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

Analysis of Protein Biopharmaceuticals

Chapter 6. Techniques of Protein and Nucleic Acid Purification

Executive Summary. clinical supply services

Capillary Electrophoresis of Proteins

Application Note. Biopharm. Author. Abstract. Christian Wenz Agilent Technologies, Inc. Waldbronn, Germany

Sean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL RESULTS AND DISCUSSION

2-D Capillary Electrophoresis Analysis of Complex Protein Mixture

Optimization of cief to Resolve Challenging MAb Samples of Clinical Immunodiagnostic Relevance

Biotechniques ELECTROPHORESIS. Dr. S.D. SARASWATHY Assistant Professor Department of Biomedical Science Bharathidasan University Tiruchirappalli

Determination of Isoelectric Point (pi) By Whole-Column Detection cief

ph gradient analysis of IgG1 therapeutic monoclonal antibodies using a 5 µm WCX column

Simplifying CE-SDS Data Processing

Kevin D. Altria. Analysis of Pharmaceuticals by Capillary Electrophoresis

Automated and quantitative analysis of biologics

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

ALP (alkaline phosphatase) calibrators were analyzed manually in microtiter plates to find the linearity range by following this protocol:

TECHNICAL INFORMATION

Chromatography column for therapeutic protein analysis

Unified Workflow for Monoclonal Antibody Charge Heterogeneity, Purity, and Molecular Weight Analysis

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Assay of IgG Purity and Heterogeneity using High-Resolution Sodium Dodecyl Sulfate Capillary Gel Electrophoresis

ELECTROPHORESIS TECHNOLOGY: GLOBAL MARKETS. MST040C April Andrew McWilliams Project Analyst ISBN:

Purification of oligonucleotides by anion exchange chromatography

The Biotechnology Toolbox

B. Incorrect! Ligation is also a necessary step for cloning.

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Microfluidic Assays for High Throughput Screening of Protein Quality in Bioprocess Development

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

Size Exclusion BioHPLC Columns

High-Resolution Separation of Intact Monoclonal Antibody Isoforms

Purification: Step 1. Lecture 11 Protein and Peptide Chemistry. Cells: Break them open! Crude Extract

Purification: Step 1. Protein and Peptide Chemistry. Lecture 11. Big Problem: Crude extract is not the natural environment. Cells: Break them open!

Application Note. Abstract. Author. Biopharmaceutical

Assessment of Active Biopharmaceutical Ingredients Prior To and Following Removal of Interfering Excipients

Comparison of ExoSAP-IT and ExoSAP-IT Express reagents to alternative PCR cleanup methods

ARBRE-P4EU Consensus Protein Quality Guidelines for Biophysical and Biochemical Studies Minimal information to provide

Automated and quantitative

AdvanceBio Peptide Mapping

Vectors for Gene Cloning: Plasmids and Bacteriophages

Lecture 5: 8/31. CHAPTER 5 Techniques in Protein Biochemistry

Alternative to 2D gel electrophoresis OFFGEL electrophoresis combined with high-sensitivity on-chip protein detection.

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Lecture Four. Molecular Approaches I: Nucleic Acids

Molecular characterization, detection & quantitation of biological products Purin Charoensuksai, PhD

Quality and Quantity Assessment of Nucleic Acids and Proteins. Ebru Serinsöz Linke, MD/PhD

Comparison of Different Brands of Carrier Ampholytes for Monoclonal Antibody Charge Heterogeneity Analysis by Capillary Isoelectric Focusing

HOST CELL PROTEIN & BIOPROCESSING REAGENT DEVELOPMENT

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

SDS-CGE Method Development for Purified Protein Vaccine Antigens

AdvanceBio HIC: a Hydrophobic HPLC Column for Monoclonal Antibody (mab) Variant Analysis

Instructions for Capillary Electrophoresis Peptide Analysis Kit

electrophoresis tech Performance Comparison of the Experion Automated Electrophoresis System and SDS-PAGE for Protein Analysis

HT Pico Protein Express LabChip Kit, Frequently Asked Questions

Proteomics and Vaccine Potency Testing

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Application Note 18 RNA/DNA/Protein Sample Preparation METHODS AND MATERIALS INTRODUCTION

Isolation of Protein

Proteomics and Cancer

Importance of Molecular Genetics

PROTEINS. *Adapted from Biotechnology: Science for the New Millennium by Ellyn Daugherty.

Higher Order mab Aggregate Analysis using New Innovative SEC Technology

The Simple Western Approach to Vaccine and Clinical Protein Research

Comparison of different methods for purification analysis of a green fluorescent Strep-tag fusion protein. Application

Selected Techniques Part I

CE as an analytical tool in industrial biotechnology. David Goodall, CSO, Paraytec Ltd. 14 November Act P x

10 Reasons to Switch from SDS-PAGE to the Agilent 2100 Bioanalyzer

Fast and High Resolution Analysis of Intact and Reduced Therapeutic Monoclonal Antibodies (mabs)

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Motivation From Protein to Gene

Fast IEF Method Development Using Whole-Column Detection cief

Modulating the Cascade architecture of a minimal Type I-F CRISPR-Cas system

Increasing Sensitivity In LC-MS. Simplification and prefractionation of complex protein samples

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Novel instrumentation to gain insight into the aggregation state of proteins by Taylor Dispersion Analysis: a comparison with Dynamic Light Scattering

TOYOPEARL GigaCap Series

Microchip Electrophoresis for Glycoprotein Separation. Analytical Strategy, September 30th, 2014 Karina Hasler & Adrian Müller

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

APPLICATION INFORMATION

The power of precision. cief pi Marker Kit

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

Transcription:

Applications of deltadot s Label Free Intrinsic Imaging Technology March 2012

Introduction to deltadot Ltd deltadot is a biotechnology company selling into the biomedical and analytics markets. At its core is the proprietary Label Free Intrinsic Imaging (LFII ) approach. LFII has significant advantages over other approaches. It has a wide spread of applications and customers in many sectors including biotech, academic, industrial and government sectors. deltadot Ltd owns 19.9% of deltadot QSTP-LLC and receives about $900K per year from Qatar (plus cash from sales of any instruments). The proposed route to market involves working with other established companies via collaborations and selling through distributors

Market Analysis Label Free Intrinsic Imaging brings advantages to: drug discovery and development QC/QA, biopharmaceutical production proteomics vaccine development general biotech threat identification forensics diagnostics analytical chemistry food and drink

Commercial offering deltadot offers: Capital sales Collaboration deals Service Business Rental / leasing OEM deals Strategic Partnerships The PEREGRINE I HPCE system

Label Free Intrinsic Imaging theory. 5

Capillary Electrophoresis systems Conventional single point detection systems image each protein only once deltadot s LFII technology images each protein band 512 times across a photo diode array at ~15 Hertz It is our ability to track an entity as it passes through these multiple detectors and correlate the space/time data, seen as a sloped signal, that gives LFII its power. The junction of the signals is called the VERTEX. Any signals that do not hit the vertex are discarded. 6

Pixel deltadot LFII technology 0 512 Detector Capillary INJECTION Time

Pixel 1 st protein crosses the detector 0 512 Velocity of the proteins through the capillary with is tracked across the multipixel detector INJECTION Time

Pixel Different proteins Different velocities 0 512 INJECTION Time

Pixel The signal slope define the injection point 0 512 INJECTION Time

Pixel arb 0 512 Time Noise - thermal, electrical etc does not intercept the Vertex and is discarded INJECTION Time

Label Free Intrinsic Imaging The vertex created by the space/time data is used to filter noise and dramatically increase the data quality. It also improves:- Quantification Resolution Reproducibility The amplitude of the peak directly correlates to the level of absorption from, for example, the peptide bond in proteins, and allows for highly accurate quantification. 12

Advantages of HPCE Traditional I-Dimensional Polyacrylamide gel electrophoresis 1D gels are 1950 s Technology. They take hours to run They take hours to stain They take hours to destain They take hours to dry They take hours to analyse They take hours to document HPCE Fast, accurate, inherently digital, quantitative, reproducible and high resolution. LFII has two major signal processing algorithms :- Generalised Separation Transform Equiphase Vertexing Algorithm Beckman protein standard ladder 13

Features of LFII Novel Label Free data acquisition: - No potential effects of fluorophores on molecules behaviour. - Reduce the costs of analysis Highest CE specs for resolution, sensitivity & reproducibility providing the customer with the best possible data: - Resolution (CGE ~200Da, <10bp DNA) - Sensitivity (~1.0 µg/ml protein - LOQ) - Reproducibility (<4% RSD) - Quantitative (<2% RSD for simple mixtures, 5% for complex lysates etc.) - Linear Dynamic Range (5 orders concentration, 4 in MW) UV detection 214/254/280nm enabling the analysis of Protein, DNA, RNA virus particles and small molecules deltadot software is currently undergoing CFR21 11 compliance 14

deltadot and regulatory affairs deltadot have been working with end-users for several years on regulatory issues for hardware, software and bioproduction issues. deltadot has:- Helped a Cambridge company with Bioproduct regulatory steps for a vaccine satisfied our colleagues in Texas on IQ and OQ for the Caliber vaccine factory PEREGRINES Made significant progress on our CFR21/11 compliance Good experience of CE and other hardware conformity standards 15

Measuring the Bioprocess using Label Free Intrinsic Imaging systems. 16

Areas of capability Capillary Gel Electrophoresis CGE Capillary Zone Electrophoresis CZE Molecular weight based separations Charge based separation direct UV absorption Indirect UV absorption Capillary ElectroChromatography CEC Charge-Molecular weight and stationary phase based separations Micellar Electrokinetic Capillary Chromatography MECC Separation of neutral species Chiral Capillary Separation Separation of enantiomer species 17

Multiple Analysis Capabilities Low bias and label independent molecule analysis Proteomics Genomics Viral expression titre Small Molecules Carbohydrates Inorganic Acids 18

Bioprocessing Manufacturing therapeutic proteins APPLICATION Restriction enzyme mapping Vector cleavage, Insertion / ligation DNA sequencing Protein expression monitoring Phage contamination Media monitoring a.a. content + salts, ions etc by indirect detection Physical parameters - ph, C, O 2, etc Protein expression monitoring Endotoxin contamination Cellular DNA contamination High-End Quality control (solubility, fragmentation, modifications and conformation) TRADITIONAL TECHNOLOGY Agarose Gel Electrophoresis CE Sequencing New Tech Sequencing Standard metrics ELISA HPLC Spectrophotometry PAGE IEF CE proteomics MDS Threshhold Mass Spectroscopy Cambrex Pyrogene qpcr cief FortéBio OCTET Multiple Data inputs 19

Bioprocessing Manufacturing therapeutic proteins TRADITIONAL TECHNOLOGY Agarose Gel Electrophoresis $20K + Cons CE Sequencing $150K per system New Tech Sequencing - e.g. 454 $?+ Cons Standard metrics $100K per lab? ELISA HPLC $30K per seat + Cons $50K per system + Cons Spectrophotometry $12K per system deltadot PEREGRINE I system - provides comparable data to many of these multiple data input systems and excellent data compared to many. PAGE $10K per system + Cons IEF $30K plus per system? CE proteomics $80K per system + cons MDS Threshhold $75K per system Mass Spectroscopy $150K per system? Cambrex Pyrogene $100K? Single data inputs qpcr $35K per RT system + Cons cief $? FortéBio OCTET $? 20

Nucleic acid analysis 6 traces of a standard DNA ladder Oligonucleotide separation Using a commercially available buffer oligonucleotides ranging from 8-32 mers were separated on a 22 cm long bare fused silica of 75µm ID. Sample was injected at 9kV for 5 seconds and run at a voltage of 12kV. Promega and custom standard ladders

Baculovirus Analysis A collaboration with BRAD GlaxoSmithKline LFII systems enables samples to be analyzed in 1 hour Throughput - 10 samples per hour Real time monitoring of baculovirus titers Excellent linearity is shown calibration curve in a concentration range between 1.2 10 6 and 1.2 10 9 pfu ml 1 Dilution series on stock 6.7x10 8 pfu/ml.1:2, 1:5, 1:10, 1:100 Baculoviruses are extensively used as eukaryotic expression vectors for proteins requiring post translational modifications such as glycosylation, proteolytic cleavage and fatty acylation. GSK virus sample 22

Orientation Of Baculovirus The main virus peak resolves into three separate peaks all of which show orientation with increasing field strength. The plateau seen at higher field strengths is when the virus is parallel to the field and no further rotation is observed leading to a consistent mobility value. Grossman, P. D., Soane, D. S., Analytical Chemistry 1990, 62, 1592-1596. Grossman and Soane Result using Tobacco Mosaic Virus

Indirect UV Amino Acid Analysis EVA processed data of amino acid standard solution (Sigma A6407) 24

Voltage Conditions on Amino Acid Profile EVA Trace 12, 13 10, 11 13 10, 11 14 12 15 14 15 10 11 12 13 14 15 18 kv 20 kv 22 kv 11 12 13 14 12 13 14 11 15 10 10 15 26 kv 28 kv

Peptide Analysis Abs (arb) Percentage RSD values for peak time and peak area for all nine peaks of the peptide standard mixture (N=10). Time (mins) Plot of sample concentration versus peak area. Reproducibility. SIGMA standard peptide ladder 26

E.coli Analysis Conventional PAGE Conventional CE Label Free Intrinsic Imaging Overlay of the EVA processed data of nine consecutive E. coli lysate runs all separated under the same conditions. BioRad E.coli Cell lysate standard 27

Heart Lysate Analysis 10 kda 20 kda 35 kda 50 kda 100 kda mw Sample S Sample 2 Sample 1 mw Sample S Sample 2 Sample 1

Protein Profile of Spinach - Different buffer regimes Molecular Weight Standard RuBisCo S RuBisCo L Spinach lysate prepared in 2-DE lysis buffer Molecular Weight Standard Spinach lysate prepared in Beckman sample buffer

Amylase expressed in E.coli Expressed Protein Peak Expressed protein quantification in E.coli cell lysate

SDS-CGE stability analysis quantification Comparing batch-to-batch variations protein load normalized at sample prep stage Area of 6 most abundant peaks % of total protein 6 most abundant peaks

Glycoproteins Ribonuclease B Glycoforms 32

Glycoproteins GST EVA signal Abs (arb) Abs (arb) 17 18 19 20 21 15 16 17 18 19 20 21 Time (mins) Time (mins) Using the Successive Multiple Ionic Layer (SMIL) coating developed by Katayama et al 1998 protein absorption was reduced and the Transferrin isoforms were separated based on differences in their net charge. The analysis of the distribution of sialoforms has been demonstrated. Peak identification: P2 disialo-tf, P3 trisialo Tf, P4 tetrasialo Tf, P5 pentasialo Tf and P6 hexasialo Tf. Human Holo-Transferrin

Glycoproteins Abs (arb) Time (mins) EVA processed data for recombinant human EPO. There are many variation in the number of isoforms, but the main set 1-8 are used in the European Pharmacopeia analysis parameters Erythropoietin

Antibodies An antibody control standard analysed under denaturing conditions. The nonglycosylated heavy chain is clearly distinguishable from the glycosylated heavy chain. The reproducibility can be seen to be excellent over nine consecutive runs. Antibody standard 35

Antibodies The reproducibility can be seen to be excellent over nine consecutive runs. Antibody standard 36

Antibodies Capillary Zone Electrophoresis X10-2 EVA signal 0.0012 0.0010 0.0008 Abs (arb) 0.0004 0.0002 5 10 15 20 25 Time (mins) 37

Antibodies Capillary Zone Electrophoresis X10-2 0.0040 0.0035 0.0030 Abs (arbs) 0.0025 0.0020 0.0015 0.0010 0.0005 5 10 15 20 25 30 Time (mins) This preliminary data shows a clear shift for the complexed proteins IgG and anti-murine IgG 38

Protein/Nucleic acid interactions The change in single-stranded DNA binding protein (SSB) migration pattern in different concentrations of ssdna. Thiourea is added as an Electroosmotic Flow (EOF) marker. 39

Antibody/Conjugate interaction - Capillary Zone Electrophoresis Distinct separation patterns were observed for the antibody, antibody-conjugate and peptide marker samples. One single major peak was observed in the CZE separation of the antibody sample while an additional small peak with faster migration time was observed in the CZE separation of the antibody-conjugate sample. GST-processed CZE separation profile of the antibody (red), the antibody-conjugate (orange) and antibody-conjugate buffer samples (green) in the presence of the peptide internal marker overlaid with the separation profile of the peptide marker on its own (blue). 40

Forward vertexing Extrapolate the space/time correlation forward to the peak exit moment

Recovery of sample from PEREGRINE I - for further analysis in e.g. Mass Spec Samples separated in the PEREGRINE I can be further analysed by collecting the target peaks. This is achieved by forward vertexing the peak position and collecting it in a waste vial. GST Trace. Carbonic Anhydrase analysed in the PEREGRINE I system 1. MS Trace 1. MALDI spectrum of carbonic anhydrase stock control. 2. MS Trace 2. MALDI spectrum of carbonic anhydrase following collection of 20 peaks from the PEREGRINE I

Recovery of sample from PEREGRINE I - for further analysis in e.g. SEM Samples separated in the PEREGRINE I can be further analysed by collecting the target peaks. This is achieved by forward vertexing the peak position and collecting it in a waste vial.

IEF -performed by capillary electrophoresis (clef) with chemical mobilization cief separation of sample containing a mixture of Ribonuclease A, carbonic anhydrase II, β-lactoglobulin-a and CCK flanking peptide overlaid on a sample containing Ribonuclease A, carbonic anhydrase II, β-lactoglobulin-a and CCK flanking peptide.

Conclusions In the Bioprocess, LFII can be used to analyse cloning steps the titre of e.g. Baculovirus expression systems, the bioreactor media components the expression level of the target protein the final QA/QC steps. This approach in the bioprocess workflow allows great economies of scale, reduces analytical bias and offers a step-change in power necessary for the huge increase in throughput required by the goal accelerating drug development. 45

Other applications of LFII 46

Other sample analyses Various acids analysed by LFII Carbohydrate analysis PolyCyclic Aromatic Hydrocarbon Mix Fatty Acid standards at 0.5mM 47

Other sample analyses Indirect UV Analysis of Tap Water Nicotine analysis Pesticide sample mix Chiral Analysis 48

Conclusions LFII can be used to analyse Small molecules Chiral drugs Inorganic acids Carbohydrates Anions in water This universal LFII approach to analyses that usually have to be performed on multiple platforms allows great economies of scale, reduces analytical bias and delivers enormous cost savings in capital equipment, service contracts, personnel costs and consumables 49