MATERIAL- OCH MEKANSTANDARDISERINGEN, MMS (1+6)

Similar documents
SVENSK STANDARD SS-EN ISO 1127

SVENSK STANDARD SS-EN 1910

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN ISO 642

SVENSK STANDARD SS-EN 12084

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN 12487

SVENSK STANDARD SS-EN Tillsatsmedel till betong, bruk och injekteringsbruk. Del 13: Referensbruk för provning av tillsatsmedel till murbruk

SVENSK STANDARD SS-EN In vitro-diagnostik Stabilitetsprovning av in vitro-diagnostiska medicintekniska produkter

SVENSK STANDARD SS-EN 376. In vitro-diagnostik Märkning av reagenser för självtestning

Plast - Bestämning av draghållfasthet - Del 1: Allmänna principer (ISO 527-1:1993 inkl Corr 1 :1994)

Kylsystem och värmepumpar Kompetens hos personal. Refrigerating systems and heat pumps Competence of personnel

Bar coding - Multi industry trans- Datarepresentation - Streckkoder - port label. Branschoberoende transportetikett

Aluminium and aluminium alloys Scrap Part 3: Wire and cable scrap

Ships and marine technology Drainage systems on ships and marine structures Part 4: Sanitary drainage, sewage disposal pipes (ISO :2004)

SVENSK STANDARD SS-EN :2004. Provningsmetoder för eldfast tegel Del 19: Bestämning av termisk utvidgning med en differentiell metod

SVENSK STANDARD SS-EN Magnetiska material Specifikation för sintrade mjukmagnetiska material

SVENSK STANDARD SS-EN ISO 14161

Zink och zinklegeringar Kemisk analys Del 6: Bestämning av aluminium och järn Spektrometrisk flamatomabsorptionsmetod

Träfiberskivor Krav Del 3: Medelhårda träfiberskivor. Fibreboards Specifications Part 3: Requirements for medium boards

SVENSK STANDARD SS-EN 10271

Träbaserade skivor Flytande golv Del 1: Specifikationer och funktionskrav

SVENSK STANDARD SS-EN ISO

Avlopp Reningsanläggning för pe Del 9: Luktkontroll och ventilation. Wastewater treatment plants Part 9: Odour control and ventilation


Plast Insamling och presentation av jämförbara data från flerpunktsmätningar Del 1: Mekaniska egenskaper (ISO :2001)

SVENSK STANDARD SS-EN Hydrometri Utformning av yta kring referensregnmätare. Hydrometry Specification for a reference raingauge

SVENSK STANDARD SS-EN 50126

SVENSK STANDARD SS-EN ISO 24034:2005

SVENSK STANDARD SS-EN 12862

Icke aktiva kirurgiska implantat Allmänna krav (ISO 14630:2005) Non-active surgical implants General requirements (ISO 14630:2005)


Del 1: Koboltbaserade Iegeringar (ISO :1994) (ISO :1994)

Dental base metal casting alloys - Tandvård - Basmetallegeringar -

Temporära konstruktioner Stämptorn av prefabricerade komponenter Dimensioneringsmetoder

SVENSK STANDARD SS-EN Betongkonstruktioner Provning av produkter och system för skydd och reparation Beständighet hos konstruktionslim

SVENSK STANDARD SS-EN Gipsblock (murblock) Definitioner, krav och provningsmetoder. Gypsum blocks Definitions, requirements and test methods


Lantbruksmaskiner Bandspridare för konstgödsel Miljöskydd Del 2: Provning. Agricultural machinery Solid fertilizer linedistributors

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN 934-3:2004. Tillsatsmedel till betong, bruk och injekteringsbruk Del 3: Fordringar för tillsatsmedel till murbruk

SVENSK STANDARD SS-EN 12469

SVENSK STANDARD SS-EN Sågningsskydd Del 10: Provningsmetoder för skydd för överkroppen

Ögonimplantat Intraokulära linser Del 6: Hållbarhetstid och transporttålighet (ISO :2002, modifierad)

Foderrör av spirallindad stålplåt avsedda för spännkablar Fordringar och kvalitetkontroll

Koppar och kopparlegeringar Bestämning av antimonhalt Del 2: FAAS metod

Hot applied joint sealants Part 12: Test method for the manufacture of concrete test blocks for bond testing (recipe methods)

Wastewater treatment plants Part 16: Physical (mechanical) filtration

Koppar och kopparlegeringar Sömlösa kopparrör för elektriska ändamål

Förpackningar Pallboxar Allmänna specifikationer för provning

Magnetic materials - Specification for steel sheet and strip with specified mechanical properties and magnetic permeability


SVENSK STANDARD SS-EN


Aerospace series Quality management systems Assessment applicable to maintenance organizations (based on ISO 9001:2000)

Ögonimplantat Intraokulära linser Del 7: Klinisk prövning (ISO :2001, modifierad)

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN Aluminium och aluminiumlegeringar Smide Del 3: Toleranser för dimensioner och form

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN 13741:2004. Värmeteknisk prestandaprovning av mekaniskt kylda serietillverkade våtkyltorn

SVENSK STANDARD SS-EN 13374:2004. Temporary edge protection systems Product specification, test methods

Vattenförsörjning Tappvattensystem för dricksvatten Del 3: Tappvattenrör Förenklad metod

Bruk för murverk Krav Del 2: Murbruk. Specification for mortar for masonry Part 2: Masonry mortar

Metallic materials Vickers hardness test Part 1: Test method (ISO :2005)

Petroleum- och naturgasindustri - Borrör av stål - Krav (ISO 11961:1996)

Office furniture Storage furniture Part 3: Test methods for the determination of stability and strength of the structure

Byggdokumentation Förenklad redovisning av betongarmering (ISO 3766:2003)

Trägolv Mosaikparkett. Wood flooring Mosaic parquet elements

Rörledningar Korrugerad metallslang med anslutningar (ISO 10380:2003)


Glasfasader Produktstandard. Curtain walling Product standard

Provläsningsexemplar / Preview


Informationsteknik AutoID-tekniker Streckkodsläsare prestandamätning (ISO/IEC 15423:2004)

SVENSK STANDARD SS-EN Avlopp Reningsanläggning Del 13: Kemisk behandling Behandling genom fällning och flockning

Armeringsstål och stål för spännarmering Provningsmetoder Del 1: Stång, valstråd och tråd (ISO :2002)

Plastsvetsningspersonal Kvalifikationsprovning av svetsare Termoplastiska svetsade monteringar

SVENSK STANDARD SS-EN

Trägolv Lövträ Till element sammansatta brädor

Byggnadsglas Alkaliska jordartsmetallsilikatglas

SVENSK STANDARD SS-EN




SVENSK STANDARD SS-EN 13581

Termisk sprutning Karakterisering och provning av termiskt sprutade skikt (ISO 14923:2003)


Transcription:

STANDARDISERINGEN I SVERIGE SWEDISH STANDARDS INSTITUTION SVENSK STANDARD SS-EN 1093-3 Handläggande organ Fastställd Utgåva Sida MATERIAL- OCH MEKANSTANDARDISERINGEN, MMS 1996-04-19 1 1 (1+6) SIS FASTSTÄLLER OCH UTGER SVENSK STANDARD SAMT SÄLJER NATIONELLA, EUROPEISKA OCH INTERNATIONELLA STANDARDPUBLIKATIONER Safety of machinery Evaluation of the emission of airborne hazardous substances Part 3: Emission rate of a specified pollutant Bench test method using the real pollutant Maskinsäkerhet Beräkning av utsläpp av Iuftburna farliga ämnen Del 3: Emissionshastigheten för en specifik Iuftförorening Mätning i box med den verkliga föroreningen The European Standard has the status of a Swedish Standard. This document contains the official English version of. Swedish Standards corresponding to documents referred to in this Standard are listed in Catalogue of Swedish Standards, annually issued by SIS. The Catalogue lists, with reference number and year of Swedish approval, International and European Standards approved as Swedish Standards as well as other Swedish Standards. Europastandarden gäller som svensk standard. Detta dokument innehåller den officiella engelska versionen av. Motsvarigheten och aktualiteten i svensk standard till de publikationer som omnämns i denna standard framgår av Katalog över svensk standard, som årligen ges ut av SIS. I katalogen redovisas internationella och europeiska standarder som fastställts som svenska standarder och övriga gällande svenska standarder. ICS 13.040.40;13.110 Standarder kan beställas hos SIS som även Iämnar all- Upplysningar om sakinnehållet i standarden Iämnas av MMS. männa upplysningar om svensk och utländsk standard. Telefon: 08-665 24 00. Telefax: 08-667 85 42 Postadress: SIS, Box 6455, 113 84 STOCKHOLM Telefon: 08-610 30 00. Telefax: 08-30 77 57 Prisgrupp K Tryckt i oktober 1996

EUROPEAN STANDARD EN 1093-3 NORME EUROPÉENNE EUROPÄISCHE NORM March 1996 ICS 13.040.40;13.110 Descriptors: safety of machines, air pollution, accident prevention, emission, dangerous materials, polluant gases, measurements, rates: per unit time, test benches English version Safety of machinery Evaluation of the emission of airborne hazardous substances Part 3: Emission rate of a specified pollutant Bench test method using the real pollutant Sécurité des machines Evaluation de Sicherheit von Maschinen Bewertung der I emission de substances dangereuses Emission von Iuftgetragenen Gefahrstoffen véhiculées par I air Partie 3: Débit d émission Teil 3: Emissionsrate eines festgelegten d un polluant donné Méthode sur bane d essai Iuftverunreinigenden Stoffes utilisant Ie polluant réel Prüfstandverfahren unter Verwendung des realen Iuftverunreinigenden Stoffes This European Standard was approved by CEN on 1996-02-10. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. The European Standards exist in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CEN European Committee for Standardization Comité Européen de Normalisation Europäisches Komitee für Normung Central Secretariat: rue de Stassart 36, B-1050 BRUSSELS 1996 Copyright reserved ot CEN members Ref. No. E

Page 2 Provläsningsexemplar / Preview Contents list Foreword................................................................... 1 Scope.................................................................... 2 Normative references........................................................ 3 Definitions................................................................. 4 Principle.................................................................. 5 Description of the test rig...................................................... 6 Test method................................................................ 6.1 Position of the machine..................................................... 6.2 0peration of the machine..................................................... 6.3 Sampling plain and measurement procedures....................................... 7 Expression of results...................................................... 8 Test report................................................................ Foreword This European Standard has been prepared by Technical Committee CEN/TC 114 Safety of Machinery, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 1996, and conflicting standards shall be withdrawn at the latest by September 1996. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finland, France, Germany, Greece, lceland, lreland, ltaly, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. 1 Scope This standard describes a bench test method for the measurement of the emission rate of a specified airborne hazardous substance from machines using a test rig under specified operating conditions of the machine. This standard does not specify any value for the air velocity of the inhalable particles ¹ ). The measurement of the emission rates of a specified pollutant emitted from machines can serve for: a) the evaluation of the performance of a machine; b) the evaluation of the improvement of the machine; c) the comparison of machines within groups of machines with the same intended use (groups are defined by the function and materials processed); d) the ranking of machines from the same group according to their emission rates; e) the determination of the state of the art of machines with respect to their emission rates. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. Page ¹) The terms inhalable and respirable are defined in EN 481.

Page 3 EN 292-1 EN 292-2 EN 481 Safety of machinery - Basic concepts - General principles for design - Part 1: Basic terminology, methodology Safety of machinery - Basic concepts - General principles for design - Part 2: Technical principles and specifications Workplace atmospheres - Size fraction definitions for measurement of airborne particles 3 Definitions For the purpose of this European Standard the following definitions apply: 3.1 uncontrolled emission rate of a specified pollutant Mass of pollutant emitted from the machine into the space around the machine per unit of time. Any measures to reduce the air pollution around the machine (e. g. capture devices, containment equipment, wetting process) are not in use or activated. 3.2 controlled emission rate of a specified pollutant Mass of pollutant emitted from the machine into the space around the machine per unit of time, taking into account the effects of measures to reduce the air pollution. 4 Principle The principle of the measurement method is to operate machines under controlled conditions under a uniform air flow in a test rig and to collect a representative part of the airborne emissions in that air flow. 5 Description of the test rig The test rig consists generally of a cabin with a funnel and a duct, of rectangular or circular cross section followed by a fan (see figure 1). It is the responsibility of the type C standard committees to select parameters within the ranges given in figure 1. The fan produces an air flow in the test cabin from the inlet towards the funnel. The cabin should be equipped with a permeable inlet (e. g. macroporous filter material, perforated plastic foil or plate) in order to obtain a uniform air flow across the inlet. The selected average air velocity, in the cabin between the source and the funnel (see figure 1) is determined by the air volume flow rate, Q, in the duct. The system requires controls to ensure that a constant flow rate is maintained during a test. This air flow rate does not include the air flow rate caused by the operation of the capture device (where used) of the machine under test. The cross section of the cabin (form and dimensions) is chosen according to the size of the test object. The maximum cross sectional area of the test object shall not exceed a fifth of the cross sectional area of the cabin, A C. The cabin shall be long enough to accommodate the machine and the operator with the emission sources as close as practicable to the location specified in figure 1.

Page 4 Provläsningsexemplar / Preview cross section of the cabin; 1 test cabin cross section of the duct; 2 source ²) height of the cabin; 3 funnel height of the emission source; 4 duct average air velocity in the cabin; 5 measurement plane width of the cabin. 6 Test method 6.1 Position of the machine Figure 1: Test rig (schematic layout) To ensure that all the pollutant will be carried to the sampling plane, as far as possible, the machine should be positioned in the cabin in such a way, that - the source of the hazardous substance emitted from the machine is in the area of the transverse plane to the longitudinal axis of the cabin at a distance of I 1 from the beginning of the funnel. - the operator and additional equipment (e. g. exhaust, separation or wetting devices) are not between the source and the sampling plane. 6.2 Operation of the machine The machine shall be operated according to its intended use. The stipulation of working procedures, the tools used and the materials to be processed with specified categories of machines will be defined in type C standards. If the cleaned air from a separator linked to the machine according to the intended use is recirculated, the outlet of the separator shall be located in the cabin in such a way as to ensure that the pollutant from this secondary ²) Generally the source cannot be considered as a point, but as a zone including several sources. ³) Under some circumstances it may be necessary to use other velocities, e.g. to measure respirable fibres with a velocity of 0,05 ms ¹ may be more suitable because of the limitation of present measuring methods.

Page 5 source reaches the measurement funnel. The machine shall be operated taking into account the instructions of the manufacturer. When the machine is provided with pollution control equipment this shall be adjusted according to these instructions. Tests shall not be carried out without manufacturers specifications for operating the pollution control equipment. As least three tests shall be performed. 6.3 Sampling plane and measurement procedures The concentrations of the airborne pollutants are measured at the sampling plane in the duct (see figure 1) for the period of the test. The procedure used for concentration and flow rate measurements shall comply with appropriate international or European standards if available. The measurement of particles shall take into account the size fraction of interest. The measurement time shall be sufficient to collect concentration data representative of the normal operational cycles of the machines. It is in the responsibility of the type C-standard committees to specify how the concentration data is to be processed for the determination of the emission rates (average values, peak values). The measurement shall continue beyond the end of pollution generation for sufficient time to collect the remaining airborne pollutants. 7 Expression of results The emission rates are calculated by the formulae:... (1)... (2) where: C U denotes the pollution concentration measured in the air flow in the duct with the pollution control equipment not in use or activated; C k Q t 1 t 2 t 3 denotes the pollution concentration measured in the air flow in the duct with the pollution control equipment in use or activated; is the measured air volume flow rate in the duct; is the starting point of the test; is the end of the pollutant generation; is the end of sampling. The uncontrolled respectively the controlled emission rate are the mean value of the results of several tests. 8 Test report The test report shall include at least the following information: a) reference to this standard and appropriate type C standards; b) description of the machine tested (e. g. manufacturer, model, type, version, design, size, year of manufacture, serial number) for the machine itself and for each additional piece of equipment; c) operational data during tests including tools used with the machine and material processed on the machine; d) description of the pollution control equipment (e. g. type, design, operational data); e) description of the measurement procedures and pollutant measured; f) measuring instruments used and their most recent calibration date; g) test results; h) test laboratory;