Ground Heave Solutions

Similar documents
GROUND MOVEMENT THE CORDEK SOLUTION CELLCORE CLAYMASTER CELLFORM

GAS PROTECTION THE CORDEK SOLUTION VENTFORM MEMBRANES ANCILLARIES

PERMANENT FORMWORK SYSTEMS For In-situ Ground Beams & Pile Caps GROUNDFORM CELLFORM PILE CAPS

PERMANENT FORMWORK SYSTEMS

TECHNICAL. Clayfill Foundation Heave Protection. Stylite.

TECHNICAL DATA SHEET CIVILS & INFRASTRUCTURE CLAY HEAVE PROTECTION

12/4923. Pecavoid. Ground Heave Solution TECHNOLOGIES FOR THE CONSTRUCTION INDUSTRY

THE CUPOLEX SOLUTION EXPANSIVE SOILS. www. cupolex.ca

CORDEK VENTILATION VOID FORMERS VENTFORM PANELS

CORDEK VENTILATION VOID FORMERS VENTFORM PANELS

CORDEK BENTONITE WM A UNIQUE WATERPROOFING SYSTEM

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

tried tested trusted since 1982 manufacturing

Agrément Certificate 18/5601 website: Product Sheet 1 JABLITE GROUND HEAVE PROTECTION PRODUCTS (JGHP)

CLAYMASTER COMPRESSIBLE FILL CLAYMASTER COMPRESSIBLE FILL LOW DENSITY EXPANDED POLYSTYRENE BOARDS

OS Thermal System Installation Guide

Lattice Plate Flooring

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation.

Polyfoam Floorboard For thermal insulation of floors

Clayboard. void formation system. preventing structual damage from clayheave

Insulated Ground Floors

Foundation or Footing Design: Part 1

WHY USING A SOIL CAP ON EXPANSIVE SOIL IS NOT ALWAYS THE SOLUTION

Jabfloor 70, 100, 150, 200, 250

June Residential Refurbishment Basements

SPRINGVALE BEAMSHIELD PLUS AND PLATINUM BEAMSHIELD PLUS SYSTEM Système de solives et dalles porteuses pour planchers Bodenbalken.

Jabfloor High Performance (HP) 70 and 100

RACKHAM FLOOR SYSTEMS POLY-PLUS F/T AND POLY-PLUS F/T EXTRA FLOOR SYSTEMS

Visqueen Gas Barrier STRUCTURAL WATERPROOFING AND GAS PROTECTION SYSTEMS. CE Mark to EN 13967

Section 02 SUBSTRUCTURE

Floors Walls Roofs. Jabfloor Premium Jabfloor. APPLICATION: Perimeter Floor PRODUCTS: Vencel Resil Limited

Jablite Board 250, 300, 350, 400 and 500

Jabfloor 70, 100, 150, 200, 250

Basement Board High Performance (HP) 70 and 100

Innovative Construction Technology

Cavity Drain Systems.

Combined footings A mat or raft or floating foundation Pile caps

9 Revision B

September Saddle Flooring Systems

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors.

PRODUCT DATA SHEET SikaProof Bentonite

ARMOR-BLOCK. Installation guide. Installation Manual: ARMOR-BLOCK Retaining Wall System. Cap Block. Exposed void for planting.

To be confirmed. Extent of any underbuild Gas regime

Arxx High Performance Wallsystems

May 19, 2006 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

* The use of these areas can vary from car park space, where little waterproofing is required through to store rooms or plant rooms where a high

Product Information Bulletin

Foundations. Foundations form the major part of a buildings substructure (along with the rising walls, hardcore and ground floors)

June Non - Residential Refurbishment 5.5 Basements

Demidec. cornish concrete products Demidec Flooring and Permanent Formwork

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

Garage Conversion - Between and Under Joist Applications

Requirements for Measuring and Pricing of Structural Concrete

System Overview. Beam & Block components. BIM Objects for Beam & Block available to download Forterra.co.uk/bim

FOAMEX. i n n o v a t i v e p o l y s t y r e n e AUSTRALIAN OWNED & MANUFACTURED PRODUCT. BCA COMPLIANT

STYRENE FLOOR SYSTEMS

Rev 19. Guide to the installation of Beamshield Plus and Platinum Beamshield Plus Suspended Floor Insulation

PRODUCT DESIGN AND SELECTION GUIDE REVOLUTIONISING CONCRETE LIFTING

SIDERISE CW range: AB & CVB/C acoustic upgrades for curtain walling

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

Civil Engineering Construction Chapter 5

155 & 220 Beam Flooring Systems

Lesson 2 Substructure. Dr S.Sreenath BSc Engg, MSc Engg, MSc (ICM), MBA, PhD

Jablite Structural Board Thermal Floor System

Slab on Grade. Introduction CHAPTER 10

May Danskin. Thermal Saddle System. Level, insulate and reduce air leakage and all with one flooring system. Danskin

Prestressed Hollowcore Slabs PRECAST CONCRETE SOLUTIONS.

Dow Building Solutions Insulating floors with STYROFOAM Solutions: basic principles

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

SECTION 1. AS MASONRY STRUCTURES CODE

The difference is Guidance for the preparation of Deck Manufacturing Schedules

Construction Technology B (CON4313)

ALL-IN-ONE THERMAL FLOOR SYSTEM NON STRUCTURAL TOPPING (NST)

Jabfloor High Performance (HP) 70 and 100

S u b s t r u c t u r e W a t e r p r o o f i n g - Membranes.

Acoustray perimeter cavity stops

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Box Culverts. Easy to install, suitable for very shallow or deep fill, ideal for use in a wide variety of civil engineering applications.

WARMFLOOR. Installation Guide.

Regulations Detail Sheet 1

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

Sabah Shawkat Cabinet of Structural Engineering 2017

PREPRUFE 300R LT & 160R LT

Building Design Data

PRODUCT DATA SHEET. Product Description

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

WORKPLACE SAFETY AND HEALTH PRACTICES AWARD 2011

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

twenty six concrete construction: foundation design ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2013

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles

JABLITE FLOOR INSULATION JABFLOOR 70

ARCELORMITTAL STEEL-FIBRE-REINFORCED CONCRETE ARCELORMITTAL INSULSLAB STEEL-FIBRE-REINFORCED CONCRETE

Housing Easy Guide: Beam and Block Ground Floors

Transcription:

Ground Heave Solutions

Who are Cordek? Cordek provides technical solutions for a range of construction requirements. Innovative thinking, engineering expertise and extensive CAD/CAM capabilities enable Cordek to solve a wide variety of engineering problems. Since our formation in 1973, we have worked on major iconic projects through to domestic extensions and remain committed to supplying the best quality, value solutions, supported by the highest levels of personal service. Through a combination of research and development, coupled with identifying the problems faced by designers and contractors alike, Cordek has developed a range of products suitable for providing ground heave protection to buildings and structures. Summary of Solutions Ground Heave Cellcore HX + HG A range of products designed to protect buildings and structures from the effects of ground heave. What is Ground Heave? Ground Heave is mostly caused by the rehydration of expansive soil types, predominantly clay, typically when building near existing trees or those that have recently been removed. Additional causes of Ground Heave include permafrost and overburden recovery which is associated with deep excavations e.g. basement construction. Cordek s Ground Heave Solutions Cordek s Ground Heave Solutions consist of a comprehensive range of products including Cellcore HX, Cellcore HG, Cellform HX, Cellvent HX and Heaveguard which provide ground heave protection with additional features such as integral insulation, permanent formwork and passive gas venting. Each product is designed for use in a specific location within the foundation construction. Thermal Insulation Cellcore Plus A heave protection product with integral insulation designed to meet the specific thermal requirements of a building. Ground Gas Cellvent HX Designed for use where both heave protection and passive sub-floor ventilation of ground gases is required. Permanent Formwork Cellform HX Heave protection with integral formwork for use beneath cast in situ concrete ground beams. 3

Cellcore HX + HG Ground Heave Cellcore HX + HG Cellcore HX is Cordek s fourth generation collapsible void former and has been designed to protect foundations from the effects of ground heave. The product consists of a cellular construction of Filcor EPS (Expanded Polystyrene) which has been designed, moulded and tested to tight tolerances to achieve the specified performance characteristics. It reduces the upward force transmitted to the structure Available in a wide range of profiles and grades to suit most applications BBA certified Meets the NHBC Technical Standards Moulded production for enhanced and consistent performance Product Specification Firstly the depth of the Cellcore HX panel should be determined by the heave potential of the soil, as detailed in Table 1. Secondly, the grade of the product is determined by the depth of the concrete to be cast on the Cellcore HX panel, as detailed in Table 2. Definitions Safe Load The maximum load which can be applied to the product during the construction process. This is calculated as the total dead weight of the concrete and reinforcement (assumed to be 25kn/m 3 ) plus an allowance of 1.5kN/m 3 for the imposed load (foot traffic, heaping of concrete etc). Fail Load The load at which the legs of the Cellcore panel will collapse if the ground heaves under the concrete structure. The slab, beam or pile cap must be designed to accommodate this upward load, taking in to account the self-weight of the concrete structure. Table 1: Cellcore HX Depth Selection Table Table 2: Cellcore HX Grade Selection Table Results of Soil Analysis Plasticity Index NHBC Category Volume Change Potential Predicted ground heave or BRE / NHBC Clear Void Requirement Void Dimension Depth of Cellcore HX Required to Achieve Equivalent Void HX S 10-20 Low 50 90 85 20-40 Medium 100 160 155 HX B 40-60 High 150* 225 220 * Where the predicted ground heave is in excess of 150mm please contact the Cordek Technical Team. Grade* Safe Load (kn/m 2 ) Fail Load (kn/m 2 ) Maximum Concrete Depth** 7/10 7 10 220 9/13 9 13 300 13/18 13 18 460 18/24 18 24 660 24/32 24 32 900 *For easy identification, the panel labels are coloured as shown. **Based on the Eurocode and a imposed load allowance of 1.5 kn/m 2. Please contact the Cordek Technical Team where the depth of concrete exceeds 900mm. For concrete thicknesses between 900mm and 2000mm, Cellcore HG panels are available please refer to page 7 for further details. 5

Cellcore HX: Reduces the upward force transmitted to the structure from ground heave Wide range of profiles and grades to suit most applications Moulded production for enhanced and consistent performance Patented product technology BBA certified Meets the NHBC s Technical Standards These product features can be found in each of the available variants of the Cellcore HX S and HX B ranges, which are intended for use beneath specific foundation types as indicated below: Cellcore HX + HG Cellcore HX Design Examples Example 1: Reinforced Concrete Slab (Heave Protection) Plasticity Index of 25 Slab thickness of 450mm Step 1. Determining BRE/NHBC Volume Change Potential Table 1 indicates that a plasticity index of 25 is within the NHBC Volume Change Potential category of Medium and that an equivalent void dimension of 100mm is required. Step 2. Identifying the correct depth of Cellcore HX panel Table 1 indicates that a 160mm deep Cellcore HX S panel is required based upon the Medium Volume Change Potential / 100mm equivalent void dimension requirement. Step 3. Determining the correct grade of Cellcore HX panel Table 2 indicates that a 450mm deep reinforced concrete slab requires a 13/18 grade of panel. Step 4. Product Specification* Based upon the information provided above, the correct product specification is: Cellcore 160mm HX S 13/18 Notes: The slab must be suitably designed to accommodate the transmitted load and two possible modes of failure should be considered: The slab being lifted off the foundation Failure of the slab in bending or shear due to the residual uplift *It is recommended to include installation guidance - please refer to page 14 for details. Example 2: Reinforced Ground Beam (Heave Protection) Plasticity Index of 50 Ground Beam thickness of 600mm Step 1. Determining BRE /NHBC Volume Change Potential Table 1 indicates that a plasticity index of 50 is within the NHBC Volume Change Potential category of High and that an equivalent void dimension of 150mm is required. Step 2. Identifying the correct depth of Cellcore HX panel Table 1 indicates that a 220mm deep Cellcore HX B panel is required based upon the High Volume Change Potential / 150mm equivalent void dimension requirement. Step 3. Determining the correct grade of Cellcore HX panel Table 2 indicates that a 600mm deep reinforced concrete ground beam requires an 18/24 grade of panel. Step 4. Product Specification* Based upon the information provided above, the correct product specification is: Cellcore 220mm HX B 18/24 Notes: The beam must be suitably designed to accommodate the transmitted load and two possible modes of failure should be considered: The beam being lifted off the top of the piles Failure of the beam in bending or shear due to the residual uplift Cellcore HG: Cellcore HG is designed for use in ground heave protection applications, where the requirements of the project mean that the standard Cellcore HX product range is not suitable. Usual applications include the use beneath deep (in excess of 900mm) reinforced concrete slabs, ground beams and pile caps. The Cellcore HG panels are available in a variety of depths and grades to compliment the standard Cellcore HX range. For further information please contact the Cordek Technical Team. Cellcore HX S: Cellcore HX S is designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave. The HX S range of products are available in a variety of depths and grades to suit most commonly encountered combinations of soil heave potential and concrete depth. Cellcore HX B: Cellcore HX B is designed specifically for use beneath reinforced concrete ground beams and pile caps. The HX B range of products are available in a variety of depths, grades and can also be supplied in a range of widths to suit common ground beam and pile cap widths. 7

Cellcore Plus Thermal Insulation Cellcore Plus The Cellcore Plus product range is available in both HX and HG and is designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional benefit of providing insulation. The Cellcore Plus product consists of the same cellular construction of Filcor EPS (Expanded Polystyrene) bonded to a Filcor insulation layer protected by a thin polypropylene sheet; alternative insulation materials are available if required. Cellcore Plus products are available in a variety of depths and grades to suit most commonly encountered combinations of soil heave potential, concrete depth and U-value requirements. Meets the thermal performance required under Part L of the building regulations for England and Wales and Section 6.2 of the building standards for Scotland Meets both the ground movement requirement and thermal requirements of a ground floor or basement floor slab in a single operation saving time and reducing costs Allows for the omission of insulation above the floor slab and therefore potentially an additional floor screed Due to its use below the floor slab it reduces the potential for damage to the insulation layer during the ongoing construction process U-Value Calculation In order to undertake a U-value calculation to determine the appropriate thickness of insulation to be incorporated within the Cellcore Plus panels, we will require the following information relating to the proposed floor slab: Floor area Exposed perimeter distance Floor build-up including any finishes (with dimensions) Wall build-up (with dimensions) Target U-value Product Specification Once the correct product depth and grade has been determined based upon the heave potential (see Table 1) and concrete depth (see Table 2), then the required Filcor EPS insulation thickness should be included in the product specification e.g Cellcore 160mm HX 9/13 Plus 50mm Filcor EPS. Table 3: Cellcore Plus Thermal Performance Table Thickness of Filcor EPS Insulation Layer * Thermal Resistance m 2 c/w 50 (Standard) 1.39 75 2.08 100 2.78 125 3.47 150 4.17 *Filcor EPS thicknesses in excess of 150mm are available, as are alternative insulation materials. Please contact the Cordek Technical Team for further information. In order to determine the correct thickness of Filcor EPS insulation to be incorporated within the Cellcore Plus panel, please contact the Cordek Technical Team for further assistance including the supply of project specific U-value calculations. 9

Cellvent HX Ground Gas Cellvent HX Cellvent HX combines the benefits of the Cellcore HX range with Ventform to alleviate the effects of ground heave whilst also providing an efficient gas venting medium. It is designed for use under suitably reinforced ground floor slabs where subsidence is not expected. Provides combined ground heave protection and gas venting capabilities in a single product, thereby saving time and reducing costs Range of thicknesses and grades to suit most project requirements Light, robust and easy to install panels Unaffected by both UV light and water Cellvent HX is available in a range of specifications to accommodate the heave protection requirements of any particular project. The specification of the appropriate panel depth and grade is outlined in Tables 4 and 5 respectively and a design example is provided for further guidance. The passive venting capabilities of the Cellvent HX are based upon those of the Ventform 80 which has a clear void equivalent of 19mm. For further information regarding the Ventform product range please refer to the Cordek VOC and Ground Gas Protection brochure, which also includes details of gas membranes, vent outlets and venting accessories which can be used in conjunction with Cellvent HX to form a complete gas protection system. Product Specification Firstly the depth of the Cellvent HX panel should be determined by the heave potential of the soil, as detailed in Table 4. Secondly, the grade of the product is determined by the depth of the concrete to be cast on the Cellvent HX panel, as detailed in Table 5. Design Example 3: Reinforced Concrete Slab (Heave Protection & Passive Gas Venting) Plasticity Index of 15 Slab thickness of 300mm Step 1: Determining BRE /NHBC Volume Change Potential Table 4 indicates that a plasticity index of 15 is within the NHBC Volume Change Potential category of Low and that an equivalent void dimension of 50mm is required. Step 2. Identifying the correct depth of Cellvent HX panel Table 4 indicates that a 135mm deep Cellvent HX panel is required based upon the Low Volume Change Potential / 50mm equivalent void dimension requirement. Step 3. Determining the correct grade of Cellvent HX panel Table 5 indicates that a 300mm deep reinforced concrete slab requires a 9/13 grade of panel. Step 4. Product Specification Based upon the information provided above, the correct product specification is: Cellvent 135mm HX 9/13 Notes: The slab must be suitably designed to accommodate the transmitted load and two possible modes of failure should be considered: The slab being lifted off the foundation Failure of the slab in bending or shear due to the residual uplift Cellvent should only be used on sites where subsidence is not expected. Table 4: Cellvent HX Depth Selection Table Table 5: Cellvent HX Grade Selection Table Results of Soil Analysis NHBC Category Predicted Ground Heave or BRE / NHBC Clear Void Requirement Depth of Cellvent HX Required to Achieve Equivalent Void Grade* Safe Load (kn/m 2 )** Fail Load (kn/m 2 )** Maximum Concrete Depth* Plasticity Index Volume Change Potential Void Dimension Panel Depth 7/10 7 10 220 10-20 Low 50 135 20-40 Medium 100 205 40-60 High 150* 270 * Where the predicted ground heave is in excess of 150mm please contact the Cordek Technical Team. 9/13 9 13 300 13/18 13 18 460 18/24 18 24 660 * Based on the Eurocode and a imposed load allowance of 1.5 kn/m 2. Please contact the Cordek Technical Team where the depth of concrete exceeds 660mm. ** For definitions of Safe Load & Fail Load refer to page 5. 11

Heaveguard & Heaveguard Pile Collars Heaveguard is a highly compressible low density Expanded Polystyrene (EPS) product used as an integral part of the Cordek solution to ground heave. Heaveguard is used to protect against lateral heave, typically on the inside face of piled ground beams or deep trench fill foundations. Key features of the product include: Reduces the lateral force transmitted to the structure Wide range of sheet sizes and thicknesses to suit most applications Coloured green for easy identification on site BBA certified Meets the NHBC s Technical Standards Heaveguard Pile Collars As an integral part of the Cellcore ground heave system, Heaveguard Pile Collars aid installation by fitting securely around the pile and providing a square edge for the Cellcore panels to be butted against. Heaveguard Pile Collars are available in a variety of different collar sizes and thicknesses. Cellform HX & Heaveguard Permanent Formwork Cellform HX Aids installation of Cellcore panels Provides protection against ground heave Wide range of collar sizes and thicknesses to suit most applications Coloured green for easy identification on site Available for both round and square piles Cellform HX combines the benefits of Cellcore HX B with an economical and simple to install permanent formwork system. Each Cellform HX panel is supplied to the required beam width and depth, allowing quick installation. The principle of Cellform HX is that the hinged side panels are supported off the reinforcement cage by concrete spacers, which allows the excavation to be backfilled. The backfill supports the formwork against the concrete pressure whilst the beam is cast and thereby avoids the need for fixing and striking traditional formwork. Based upon the Cellcore HX B technology Specific beam widths and depths catered for Quick and simple to install Reduces concrete wastage Product Specification The appropriate Cellform HX type can be determined based upon the depth (Table 1) and grade selection (Table 2) information provided on pages 4 and 5. Once this has been identified, the correct width and depth of the integral formwork should be specified based upon the dimensions of the proposed ground beam e.g Cellform 160mm HX 9/13 to suit 450mm x 450mm beam. Table 6 below confirms the minimum and maximum ground beam dimensions that can be accommodated by the Cellform HX range. Heaveguard Design Notes Heaveguard, and all similar compressible polystyrene boards, require a load of approximately 40 kn/m² to compress by 50%. For this reason Heaveguard is not recommended for use under ground floor slabs, piled beams or pile caps. Product Specification* When determining the correct thickness of Heaveguard required the information provided in Table 7 details the guidelines provided by the NHBC. *It is recommended to include installation guidance - please refer to page 14 for details. Table 6: Cellform HX Integral Formwork Sizes Table 7: Heaveguard Selection Table Ground Beam Dimension Min Max Results of Soil Analysis NHBC Category Predicted Lateral Movement / NHBC Recommended Void* Heaveguard Thickness for Equivalent Void * Width 300 1200 Depth 300 900 Plasticity Index Volume Change Potential Void Dimension Heaveguard 10-20 Low - - 20-40 Medium 25 50 40-60 High 35 75 * Where the Predicted Lateral Movement is in excess of 35mm please contact the Cordek Technical Team. 13

Installation Guidance Table 8: Product Suitability Table Cellcore Installation Guidance Ensure that the panels are placed on a firm, level and well compacted surface. Typically a layer of concrete blinding beneath the panels is recommended. Individual panels should be butted together, with taping of the joints using formwork tape to avoid any grout loss between the panels. Do not overload, please refer to the maximum depth of concrete for each specific panel type detailed in Table 2 of this document. Reinforcement spacers can be placed directly on the panels, although where a heavy reinforcement cage has been specified, a concrete blinding above the panels will help to spread the spacer load. Heaveguard Installation Guidance For piled ground beams, Heaveguard is generally only required on the inside face of external ground beams, as indicated in the NHBC guidelines. The Heaveguard sheets should be placed against the face of the ground beam after striking of the formwork and prior to backfilling. If a permanent formwork system is used to cast the ground beams then the formwork should be dimensioned such that the Heaveguard sheets will fit inside the former prior to concreting. For use in deep trench fill applications the excavation width should accommodate the width of the foundation and the thickness of the Heaveguard sheets specified. Care should be taken to ensure that the Heaveguard sheets are adequately supported so that they remain in the correct position during the placement of the concrete. Typically, the excavation will be founded 500mm below the zone of influence, and the Heaveguard sheets installed in accordance with NHBC requirements, i.e. 500mm above the bottom of the trench and on the inside face of the excavation. Ground Heave Solutions Protection against vertical heave under Floor Slabs Protection against vertical heave under - Pile Caps & Ground Beams Online Technical Resources Protection against horizontal heave down the sides of foundations Integral Insulation Gas Venting We have a full range of online technical resources to help you which can be accessed at www. but if you need anything further or have any specific questions do not hesitate to get in touch with our Technical Team. Integral Formwork Cellcore HX S P Cellcore HX B P Cellcore HG P P Cellcore Plus P P Cellvent HX P P Cellform HX * P P Heaveguard P * Suitable for ground beams only. Technical Library Data Sheets Standard Details BIM Objects MSDS NBS Specifications Contact Phone: 01403 799600 Email: info@ 15