Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

150 mm. 1/8 BSPP brass male compression fitting with locknut included

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

Platinum Resistance Thermometer (PRT) Selection Guide

Cable Selection Guide

SURFACE TEMPERATURE SENSORS

How To Select And Use The Right Temperature Sensor

1. TEMPERATURE MEASUREMENT USING ELECTRICAL TECHNIQUES

GENERAL INFORMATION ABOUT RESISTANCE THERMOMETERS

5. How to Select and Use the Right Temperature Sensor

Thermal-Tab and Thermal-Ribbon Sensors

Carbon film resistors

Reference thermometer Model CTP5000

4 RESISTANCE THERMOMETRY

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

Compact Module. Enhanced Category 5 FTP Cabling System

Article on Selection & Uses of right temperature sensors

Mineral Insulated Stainless Steel & Alloy Sheathed Thermocouples & Transducer Cables & Probes

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Troubleshooting RTDs and Thermocouples

Proven Capabilities. Features and Benefits. Watlow provides:

Data sheet chainflex CF887

Zirconia Oxygen Analyzer

Platinum Ceramic Resistance Elements

Overview. A thermocouple assembly generally has four major components:

Automotive air or oil temperature Appliances cooking temperature. MOUNTING DIMENSIONS (for reference only)

Omnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring

uk.rs-online.com (UK) (International)

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Nickel Temperature Sensors 1/12

Sheathed Thermocouple Sensor (120 Series)

Proven Capabilities. Features and Benefits. Watlow provides:

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

SECTION 2: PROBES. Page 2-1

Thermometer Probes. for accurate temperature measurement. specialists in the design & manufacture of temperature measuring equipment for over 30 years

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

Temperature. Our pharmaceutical technicians look to Eutech s meters for important answers.

Thermocouple for Flue Gas Temperature Measurements,

THERMOMETER PROBES FOR ACCURATE TEMPERATURE MEASUREMENT 2019

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

In most industrial applications, temperatures are typically

humidity probes Temperature and Talk to Grant for all your data logging solutions

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Thermometer Probes. for accurate temperature measurement. specialists in the design & manufacture of temperature measuring equipment for over 30 years

Nickel Temperature Sensors 1/15

Platinum Chip Temperature Sensors with Connection Wires to EN PCA design

MEHRAN UNIVERSITY OF ENGINEERING AND TECHNOLOGY, JAMSHORO Sensors & Actuator for Automatic Systems LAB # 01 RESISTIVE TEMPERATURE TRANSDUCERS

THERMOCOUPLE TECHNICAL REFERENCE DATA

THERMOCOUPLE TECHNICAL REFERENCE DATA

SENTRAN. Low Profile Load Cell. For more information call

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

Resistance Temperature Detectors

Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5

RTDs. Offered by. Phone: (203) Fax: (203) Specialists in Valves, Controls, Pneumatics, Fluid Measurement

SENTRAN. Low Profile Load Cell. For more information call

Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:

7. EXTENSION LEADS AND COMPENSATING CABLE

SENTRAN. Low Profile Load Cell. For more information call

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

HT829 Humidity Transmitter HT839 Humidity and Temperature Transmitter Installation and Operating Instructions

OPERATING MAINTENANCE INSTRUCTIONS

M/s. INDUSTRIAL FABRICATORS.

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

Probes French Manufacturer

RTD CHARACTERISTICS TRAINER

R-Series. Lead Wire Length (H, mm)

humidity probes Temperature and Talk to Grant for all your data logging solutions

Resistance Temperature Detectors (RTD)

INDUSTRIAL TEMPERATURE SENSORS

S E C T I O N 3 : P R O B E S

Field case for temperature transmitter Model TIF11

AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide

Thermocouples. Operating and Maintenance Manual English. Thermocouples

Ignition Leads, Plugs and Safety Caps. Perfection built in

Thermocouples and RTD

General Information, Industrial Thermocouple Section

Platinum Temperature Sensors

Resistance Temperature Detectors

CG78-06B1A. Product Classification. Dimensions. Electrical Specifications. Environmental Specifications. General Specifications

measure Temperature Probes temperature probes thermocouple, PT100 (RTD) & NTC thermistor response times handle types lead types applications

Transcription:

Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting Pt100 for accurate outdoor air temperature sensing Choice of either single or dual element, or single element with 4-20mA output Painted Die-Cast Aluminium Housing L80 x W74 x H54mm Perforated stainless steel probe, 12.7mm x 75mm Surface mounting Pt100, class B to IEC 751 Temperature range -50 to 150 C M20 cable entry gland RS 236-4283 single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument RS 455-4208 dual element: Duplex 2 x 4 wire with two independent sensing elements, allowing connection to two measurement or control devices; alternatively, one sensor may be used as a primary and the other as a back-up, eliminating the need to remove and replace the probe if one of the sensors should fail can be connected to any Pt100 2, 3 or 4 wire instrument RS 455-4214 single element with 4-20mA output: Includes integral transmitter which converts the Pt100 sensor output to a standard industrial 4 to 20mA output signal over pre-configured range of -50 to +150 C. It is also configurable by the user allowing range and burnout direction to be changed. It also allows the user to trim output current at either 4 or 20mA

Specifications Sensor type: Construction: Probe temperature range: Cable entry: Pt100 (100 Ohms @ 0 C) to IEC 751, Class B RS 236-4283: 4 wire single element RS 455-4208: 2 x 4 wire dual element RS 455-4214: 3 wire single element with transmitter, 4-20mA 2 wire current loop output, default range -50 to +150 C (other ranges can be scaled/configured by user, 25 C minimum span - further transmitter specifications below) *Note transmitter device has an ambient operating range of -40 to +85 C Housing Painted Die-Cast Aluminium Probe 12.7mm diameter x 75mm long 316 stainless steel sheath. -50 C to +150 C M20 Nylon cable entry gland Sensor No. of Pt100 4-20mA Allied Code RS Order code type elements connection output Pt100 Single 4 wire No 70641758 236-4283 Pt100 Duplex 2 x 4 wire No 70644358 455-4208 Pt100 Single 3 wire Yes (2 wire) 70644359 455-4214 TRANSMITTER SPECIFICATION @ 20 C INPUT Sensor Type PT100 100R @ 0 C 2 or 3 Wire Sensor Range (-200 to +850) C (18 to 390) Ω Sensor Connection Screw terminal Minimum span (*1) 25 C Linearisation BS EN 60751(IEC 751) standard /JISC 1604 Measurement Accuracy (*2) 0.2 C ± 0.05% of Reading Thermal Drift 0.0025 % / C Excitation current <200 ua Lead Resistance effect 0.002 C / Ohm Maximum lead Resistance 20 Ohms per leg OUTPUT Output Output range Output Connection Maximum output Minimum output Accuracy Type 2 wire (4 to 20) ma current loop (4.0 to 20.0) ma Screw Terminal 21.5mA (in high burnout condition) <3.9 ma (in low burnout condition) (ma output /2000) or 5 ua (Whichever is the greater)

Loop Voltage effect 0.2 ua / V Thermal drift 1 ua / C Maximum output load [(Vsupply-10)/21]K Ohms (Example: 700 Ohms @ 24V) GENERAL SPECIFICATION Update time Response Time Start-up time Warm-up time Power Supply 500 ms 1 second 4 seconds ( I out < 4 ma during start up) 1 minutes to full accuracy (10 to 30) Volts dc PUSH BUTTON CONFIGURATION A single push button and LED indicator allows the user to navigate a three menus, allowing configuration of the transmitter. The menus are as follow: - Menu 1 Configure range. Menu 2 Configure burnout direction. Menu 3 Trim output current @ either 4 ma or 20 ma ENVIRONMENTAL Ambient operating range (-40 to +85) C Ambient storage temperature (-50 to +90) C Ambient humidity range (10 to 90) % RH non condensing Note *1 Any span may be selected; full accuracy is only guaranteed for spans greater than the minimum recommended Note *2 Basic measurement accuracy includes the effects of calibration, linearisation and repeatability WIRING CONNECTIONS

Need RTD Cable or Pt100/Pt1000 Detectors? RTD Extension Cable 4 core (10 or 25 metre reel) Platinum Resistance Thermometer Extension Cable Silicone Rubber Insulated Silicone rubber insulated cable for extending Platinum Resistance Thermometers Can be used to extend up to 4 wire RTD configurations Commonly used with Pt100Ω thermometers but suitable with other types Pt130/500/1000Ω etc. 4 core silicone rubber insulated 7/0.2mm tin plated copper conductors, twisted together with silicone rubber outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 Good electrical and mechanical properties, highly flexible, resistant to oils, acids and other adverse fluids Good heat resistance up to 200 C Insulation rating -40 C to 200 C Supplied in 10 or 25 metre reel lengths Type Conductors mm² Cores (4 core) Jacket Reel Length Allied RS order Code Code RTD 7/0.2mm 0.219 2x Red / 2 x White Brown 10 metres 70657147 827-5823 RTD 7/0.2mm 0.219 2x Red / 2 x White Brown 25 metres 70644361 455-4242 Overall sheath Dimension (approx.) 4.0mmØ

RTD Extension Cable 4 & 6 core PFA Platinum Resistance Thermometer Extension Cable, PFA insulated & screened 4 core (cores: 2 x red / 2 white) 6 core (cores: 4 x red / 2 x white) PFA insulated cable for extending Platinum Resistance Thermometers High temperature to 260 C, extruded PFA Teflon construction Commonly used for Pt100Ω thermometers, also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 & 6 core available to extend 2, 3 or 4 wire RTD configurations, the 6 core can be used to extend 2 x 3 wire duplex (dual element) configurations Construction PFA insulated 7/0.2mm tin plated copper conductors, twisted cores with nylon cord, tin plated copper braided screen with PFA insulated outer jacket Cores colour coded Red & White in accordance with IEC-751, black outer jacket Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids Insulation rating -75 C to 260 C See below for available reel lengths Type Conductors mm² Cores Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 x 4 Yes Black 10 metres 70646175 611-8078 RTD 7/0.2mm 0.219 x 4 Yes Black 25 metres 70646176 611-8090 RTD 7/0.2mm 0.219 x 4 Yes Black 50 metres 70657148 827-5827 RTD 7/0.2mm 0.219 x 4 Yes Black 100 metres 70657150 827-5836 RTD 7/0.2mm 0.219 x 6 Yes Black 25 metres 70646177 611-8107 RTD 7/0.2mm 0.219 x 6 Yes Black 50 metres 70657151 827-5839 Overall sheath Dimension (approx.) 4 core: 3.2mmØ 6 core: 3.8mmØ

RTD Extension Cable 4 core PTFE (10 & 25 reel lengths) Platinum Resistance Thermometer Extension Cable, PTFE insulated & screened PTFE insulated cable for extending Platinum Resistance Thermometers High temperature to 260 C, wrapped PTFE tape construction Can be used to extend 2, 3 or 4 wire RTD configurations Commonly used for Pt100Ω thermometers, also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 core PTFE insulated 7/0.2mm silver plated copper conductors, twisted cores, Mylar tape, silver plated copper braided screen with PTFE insulated outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 + black outer jacket Good mechanical strength and flexibility, resistant to oils, acids and other adverse fluids, steam, gasses etc. Insulation rating -75 C to 260 C Supplied in 10, & 25 metre reel lengths Type Conductors mm² Cores (4 core) Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 10 metres 70644773 492-9775 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 25 metres 70642885 290-4976 Overall sheath Dimension (approx.) 3.5mmØ

RTD Extension Cable 4 core PVC (10, 25 & 50 reel lengths) Platinum Resistance Thermometer Extension Cable, PVC insulated & screened PVC insulated cable for extending Platinum Resistance Thermometers Can be used to extend 2, 3 or 4 wire RTD configurations Commonly used for Pt100Ω thermometers but also suitable with other types such as Pt130, Pt500 & Pt1000Ω 4 core PVC insulated 7/0.2mm tin plated copper conductors, twisted cores, polyester tape & nylon cord, tin plated copper braided screen with PVC insulated outer jacket Cores colour coded 2 x Red / 2 x White to IEC-751 with black outer jacket Heat resistant PVC to 105 C Good for general purpose cable, highly flexible & waterproof Insulation rating -10 C to 105 C Supplied in 10, 25 & 50 metre reel lengths Type Conductors mm² Cores (4 core) Screen Jacket Reel Length Allied Code RS order code RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 10 metres 70644772 492-9753 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 25 metres 70642884 290-4954 RTD 7/0.2mm 0.219 2x Red/2x White Yes Black 50 metres 70646179 611-8129 Overall sheath Dimension (approx.) 4.4mmØ

Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A, B and 1/3DIN For use from 50 C to +500 C Thin film construction Suitable for surface & immersion applications where protected Vibration resistant Specifications: Sensor type: Pt100 (100 Ohms @ 0 C) Construction: Thin film, 10mm tails Temperature range: -50 C to +500 C Ice point resistance: 100Ω Fundamental interval (0 C to 100 C): 38.5Ω (nominal) Self-heating: <0.5 C/mW Thermal response: 0.1s Stability: ±0.05% Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt100 2 x 5.0mm Class A 70646146 611-7788 Pt100 2 x 5.0mm Class B 70646148 611-7801 Pt100 2 x 5.0mm Class B 70642888 290-5070 (Packet of 5) Pt100 2 x 10mm Class A 70643577 362-9799 Pt100 2 x 10mm Class B 70641762 237-1607 Pt100 2.0 x 10mm 1/3DIN 70643578 362-9812 Pt100 2.0 x 2.3mm Class A 70643579 362-9834 Pt100 2.0 x 2.3mm Class B 70643580 362-9840 Pt100 2.0 x 2.3mm 1/3DIN 70643581 362-9856 Pt100 Elements (continued) Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt100 1.2 x 1.6mm Class A 70646834 666-7362 Pt100 1.2 x 1.6mm Class B 70646831 666-7353

Pt100 1.0 x 3.0mm Class A 70646833 666-7359 Pt100 1.0 x 3.0mm Class B 70646832 666-7356 Pt100 2.0 x 5.0mm 1/3 Din 70656467 814-0162 Pt100 1.2 x 4.0mm Class B 70656468 814-0165 Pt100 1.2 x 4.0mm Class A 70656469 814-0169 Pt1000 Elements, Thin Film (1000 Ohm) Pt1000 elements to IEC 751 Class A and B For use from 50 C to +500 C Thin film construction Suitable for surface & immersion applications where protected Vibration resistant Specifications: Sensor type: Pt1000 (1000 Ohms @0 C) Construction: Thin film, 10mm tails Temperature range: -50 C to +500 C Ice point resistance: 1000Ω Fundamental interval (0 C to 100 C): 385Ω (nominal) Self-heating: <0.5oC/mW Thermal response: 0.1s Stability: ±0.05% Resistance Dimensions (width x length) Tolerance Class Allied code RS order code Pt1000 2.0 x 10.0mm Class A 70643582 362-9907 Pt1000 2.0 x 10.0mm Class B 70643583 362-9913 Pt1000 2.0 x 10.0mm 1/3 Din 70656472 814-0178 Pt1000 1.0 x 3.0mm Class B 70656470 814-0171 Pt1000 1.25 x 1.7mm Class B 70656471 814-0175

Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or B 100Ω Ohms @ 0 C Single or dual element Platinum coil wire-wound construction sealed inside a high purity alumina ceramic body Optimum performance & stability Temperature range 200 C to +650 C Specifications: Sensor type: Pt100 (100 Ohms @ 0 C) Construction: Wire-Wound, 10mm tails Temperature range: -200 C to +650 C Ice point resistance: 100Ω Fundamental interval (0 C to 100 C): 38.5Ω (nominal) Self-heating: 0.02 to 0.3 C/mW Thermal response: <0.4s (secs. to 63% of final value in water @ 1m/s) Measuring current: 1mA Tolerance Class: In accordance with IEC 60751 W0.15 (Class A) -100 C to +450 C W0.3 (Class B) -196 C to +660 C Continued:

Single element: Resistance Tolerance Class Diameter ( D ) Length ( L ) Allied code RS order code Pt100 Class B 1.5mm 8mm 70646153 611-7851 Pt100 Class A 1.5mm 8mm 70646155 611-7873 Pt100 Class B 1.5mm 15mm 70646154 611-7867 Pt100 Class A 1.5mm 15mm 70646151 611-7839 Pt100 Class B 2.8mm 15mm 70646150 611-7823 Pt100 Class A 2.8mm 15mm 70646152 611-7845 Pt100 Class B 2.8mm 25mm 70646147 611-7794 Pt100 Class A 2.8mm 25mm 70646149 611-7817 Dual element: Pt100 (x2) Class A 1.5mm 15mm 70643873 397-1595 D L 10mm