Effect of Different Patterns and Cracking in FRP Wrapping on Compressive Strength of Confined Concrete

Similar documents
The Use of Sustainable Materials for Quick Repair of Aging Bridges

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

APPLICATION OF EXPANSIVE AGENT (EA) TO PRODUCE POST TENSIONING FORCE IN FRP JACKETS FOR LATERAL RETROFITTING OF RC COLUMNS

MODELING OF CARBON FIBER REINFORCED POLYMER (CFRP) STRENGTHENED REINFORCED CONCRETE (RC) BEAMS: EFFECT OF BEAM SIZE AND CFRP THICKNESS

Experimental research and finite element analysis of square concrete columns confined by FRP sheets under uniaxial compression

International Journal of Innovations in Engineering and Technology (IJIET)

A STUDY ON STRENGTHENING OF HOLLOW STEEL SECTION BY USING CFRP AND AFRP

Enhancing the Compressive Strength of Square Cross Sectional Column Using FRP Material

USE OF FRP COMPOSITES FOR STRENGTHENING OF RCC COLUMNS

Numerical Study on Behaviour of Concrete Filled Tubes (CFT) under Static Load

Effect of prestressed CFRP plate location on behavior of RC beam strengthened with prestressed CFRP plate

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Nonlinear Analysis of Deep Beam Reinforced with Steel Bar and Laminating FRP on Steel Bar

Experimental Behavior of Concrete Cylinders Confined with CFRP Composites

Behaviour of FRP strengthened concrete columns under eccentric compression loading

Strengthening of RCC Column Using Glass Fibre Reinforced Polymer (GFRP)

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 5, Issue 5, November 2015

beni-suef university journal of basic and applied sciences 5 (2016) Available online at ScienceDirect

ANALYSIS OF CARBON-FIBER COMPOSITE STRENGTHENING TECHNIQUE FOR REINFORCED BEAM

A Comparative Study On CFRP Confined RC Capsule Column With Varying Reinforcement Ratio

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

Use of CFRP in Confining High Strength Concrete Columns Subject to Axial Loading

Chapter 7. Finite Elements Model and Results

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Analysis of concrete columns Reinforced by Fiber Reinforced Polymers Bars Mohamed Husain, Hilal Hassan, Eman Salama

Department of Civil Engineering, UIT, RGPV, Bhopal, India

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

FIBRE COMPOSITES PILE REHABILITATION AND CONCRETE FORMWORK JACKET CONCEPT DEVELOPMENT AND FINITE ELEMENT ANALYSIS

ADVANCES in NATURAL and APPLIED SCIENCES

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Finite element modeling of RC deep beams strengthened in shear with CFRP strips

Experimental Study on RC Columns Wrapped With Hybrid FRP Sheets

Finite Element Analysis of CFRP Strengthened Concrete Beams

2.0 REVIEW OF LITERATURE. In the last few years, the use of fiber-reinforced plastic (FRP) rebars to replace steel

Analysis of Concrete Filled Double Skin Steel Tube (CFDST) column with CFRP wrapping

Parametric Analysis of Fiber Reinforced Polymer (FRP) Composites for Retrofitting of Structures

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

COMPRESSION BEHAVIOR OF CIRCULAR AND RECTANGULAR RC COLUMNS RETROFITTED BY GFRP LAMINATES: AN EXPERIMENTAL STUDY

FEM performance of concrete beams reinforced by carbon fiber bars

CHAPTER 5 FINITE ELEMENT MODELLING

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

A Numerical Investigation on the Structural Behavior of Deficient Steel Frames Strengthened using CFRP Composite

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

RESILIENT INFRASTRUCTURE June 1 4, 2016

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 5, Issue 2, August 2015

BASIC CHARACTERISTICS OF FRP STRAND SHEETS AND FLEXURAL BEHAVIOR OF RC BEAMS STRENGTHENED WITH FRP STRAND SHEETS

Strengthening of RC Beams by Wrapping FRP on Steel Bars

Study of Strength Development in Reinforced Concrete Beams Retrofitted by Different Types of Fiber Reinforced Polymers

AFRP retrofitting of RC structures in Japan

The effect of transverse steel rebars on the behavior of concrete beam reinforced with glass polymer rebars

Strengthening of Reinforced Concrete Building by Externally Bonded Carbon Fiber System

ACTIVE CFRP-BASED CONFINEMENT STRATEGIES FOR RC COLUMNS WITH RECTANGULAR CROSS SECTIONS

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

Strengthening of Beams Using Glass Fiber Reinforced Polymer (GFRP) Laminate

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

IMPROVING SHEAR CAPACITY OF RC BEAMS USING EPOXY BONDED CONTINOUS STEEL PLATES

CONCRETE-FILLED SQUARE FRP TUBES UNDER AXIAL COMPRESSION

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

Numerical Investigation on Plastic Hinge Relocation of Reinforced Beam Column Joint Retrofitted with FRP

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

ANALYTICAL STUDY ON CONCRETE FILLED STEEL TUBULAR COLUMNS WITH BFRP WRAPPING UNDER AXIAL LOAD

Upgrading Flat R.C. Slab with Haunch Using F.R.P

Analysis of Concrete Filled Double Skin Steel Tube (CFDST) column with FRP wrapping

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Flexural Behavior of Steel I Beams Bounded With Different Fiber Reinforced Polymer Sheets

International Journal of Advance Research in Engineering, Science & Technology

Maximum usable strain of FRP-confined concrete cylinders

INNOVATIVE ASSET MANAGEMENT. Research Project C. Challenges in Keeping Bridges in Good Operation Condition

EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

FRP-Confinement of Hollow Concrete Cylinders and Prisms

TENSION AND COMPRESSION TESTING OF FIBRE REINFORCED POLYMER (FRP) BARS

Study on Strengthening of RC Slabs with Different Innovative Techniques

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Hybrid Fibre Reinforced Concrete Beams Strengthened with Externally bonded GFRP Laminates

A STUDY ON THE BEHAVIOUR OF RC BEAMS RETROFITTED USING CFRP LAMINATES UNDER SINGLE POINT LOADING

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

DETERMINATION OF ULTIMATE FLEXTURAL CAPACITY OF STRENGTHENED BEAMS WITH STEEL PLATES AND GFRP INTRODUCTION

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

COMPARATIVE STUDY OF CONCRETE PRISMS CONFINED WITH G-FRP WRAPPING UNDER COMPRESSIVE LOADING

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Tension and compression testing of fibre reinforced polymer (FRP) bars

An Experimental and Analytical Study On Composite High Strength Concrete Fibre Reinforced Polymer Beams

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Finite element modeling of reinforced concrete columns seismically strengthened through jacketing partial FRP jacketing

Assistant Professor, Department of Civil Engineering, AWH Engineering College, Kuttikattur, Kozhikode, Kerala, India

Flexural strengthening of reinforced concrete beams using externally bonded FRP laminates prestressed with a new method

Finite Element Modelling of Strengthened Simple Beams using FRP Techniques: A parametric Study

Jagannathan Saravanan et al IJCSET January 2012 Vol 2, Issue 1,

Behaviour of Concrete Filled Rectangular Steel Tube Column

Confined High Strength Concrete Columns: An Experimental Study

Study on the Behaviour of Concrete Hollow Cylinder with External Confinement by CFRP, Subjected to Internal Radial Pressure

CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Flexural Behavior of Concrete Beam Reinforced with Steel and FRP Re-bars

FRP-confined concrete-encased cross-shaped steel columns: stub column tests

Confining concrete cover of GFRP tube reinforced concrete columns with polymer grids

BEHAVIOR OF FULL-SCALE SHEAR DEFICIENT CORNER RC BEAM-COLUMN CONNECTIONS RETROFITTED WITH CFRP SHEETS

Transcription:

Available online at www.sciencedirect.com Procedia Engineering 51 (2013 ) 169 175 Non-Circuit Branches of the 3 rd Nirma University International Conference on Engineering (NUiCONE 2012) Effect of Different Patterns and Cracking in FRP Wrapping on Compressive Strength of Confined Concrete Kinjal V Ranolia a, B K Thakkar b, J D Rathod b * a M.E. Sudent,M.S.University,Baroda and 390001,India b Faculty,M.S.Univeristy,Baroda and 390001,India Abstract Fiber Reinforced Polymers (FRP) are being introduced into a wide variety of civil engineering applications. These materials have been found to be particularly attractive for applications involving the strengthening and rehabilitation of reinforced concrete structure. The FRP strips provide the necessary longitudinal and hoop reinforcement, as well as a permanent formwork for the concrete core. In return, the concrete core contributes to the overall stability and stiffness of the composite system. A parametric study has been carried out to evaluate effect of number of FRP wrap layers, wrap position and position of crack in wrap on compressive strength of concrete. E Glass fiber wrapping is deployed in the present investigation. Cylinders of 300 mm height and 150 mm diameter were cast with M20 and M40 grade concrete and tested in unconfined and confined conditions with different patterns of FRP wraps such as one layer full wrap, two layers full wrap, 100 mm centre wrap and two strips wrap. Also, edge crack and centre crack were introduced in FRP wrap to understand crack propagation and subsequent loss of strength in the concrete-frp composite system. Analytical study carried out using ANSYS 10 software shows good agreement with experimental observations. The main objective of this investigation is to optimize FRP wrapping and to predict ultimate compressive strength of FRP wrapped concrete columns. 2013 2012 The Published Authors. by Published Elsevier by Ltd. Elsevier Selection Ltd. and/or peer-review under responsibility of the Institute of Technology Nirma Selection University, and Ahmedabad. peer-review under responsibility of Institute of Technology, Nirma University, Ahmedabad. Keywords: Confined Concrete, Fiber Reinforced Polymer (FRP), Finite Element Analysis (FEA). * Corresponding author. Tel.: +0-942-634-5579; fax: +0-000-000-0000. E-mail address: jdrathodmsu@yahoo.com 1877-7058 2013 The Authors. Published by Elsevier Ltd. Selection and peer-review under responsibility of Institute of Technology, Nirma University, Ahmedabad. doi:10.1016/j.proeng.2013.01.025

170 Kinjal V Ranolia et. al / Procedia Engineering 51 ( 2013 ) 169 175 1. Introduction Fiber Reinforced Polymers (FRP) composites were first developed during the 1940s, primarily for military and aerospace engineering applications. FRPs have been successfully used in many civil engineering applications as well including load bearing and infill panels, pressure pipes, tank liners, roofs, bridge repair and retrofit, mooring cables, structural strengthening, etc. FRP is a relatively new class of composite material manufactured from fibers and resins and has proven efficient and economical for the development and repair of new and deteriorating structures in civil engineering. Compared to steel and concrete, FRP composites are about 1.5 to 5 times lighter. FRP composites provide only a nominal increase in stiffness so they are generally useful for increased structural strength instead of deflection control [7]. Strengthening and increased durability against steel corrosion can be achieved in a RC structure by wrapping them with fiber reinforced polymer (2-4). Mehdi et al. [5] carried out axial compressive tests on plain concrete and GFRP confined concrete cylinders. A total of 14 GFRP confined and 6 unconfined control concrete cylinders with a diameter of 150 mm and a height of 300 mm were tested. The effect of unconfined concrete core strength was examined by using three target strengths of 10, 20 and 40 MPa. The low, normal and high strength concrete cylinders were wrapped with one layer of GFRP sheet with 0º fiber orientation with respect to the hoop direction [5]. Ciupala et al. [1] conducted studies on axial compression test of concrete cylinders confined with carbon, glass and aramid fiber reinforced epoxy composite jackets. They presented results of the behavior of concrete cylinders confined with one layer of carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fibre reinforced polymer (GFRP) [1]. Watanabe et al. [8] investigated experimentally and analytically the confinement effect of FRP sheets on the strength and ductility of concrete cylinders subjected to a uniaxial compression. Plain concrete cylinder specimens with re tested under a uniaxial compression. Variables selected for the test and analysis includes the type and the number of FRP sheets. Carbon fiber reinforced plastic (CFRP), high stiffness carbon fiber reinforced plastic (HCFRP) and aramid fiber reinforced plastic (AFRP) were used and the number of FRP sheet layers varied from 1 to 4. The analytical procedure considered a nonlinear 3-Dimensional FEM. Comparison of test results with those obtained by the analytical study showed good agreement [8]. Rochette and Labossiere [6] used an incremental finite element technique to evaluate the response of fiber wrapped square concrete columns. The model favorably compared with the results of their own uniaxial compression tests [6]. Parametric study has not been done so far by incorporating predefined crack into the wrap at various locations. In very special cases, the structures come across such a situation when either by human mistake, handling defect or due to any accidental reason cracking occurs in wrapping which leads to poor performance of the fiber wrapping in confinement. Present investigation will enable the designer to estimate strength parameters of retrofitted members in such cases. 2. Experimental Investigation The concrete mix proportions were 1: 2.2: 3.1 with w/c ratio of 0.42 and 1: 2.5: 3.3 with w/c ratio of 0.36 for M20 and M40 grade of concrete respectively. The cylinders were wrapped fully and partially with E-glass fiber reinforced polymers. Installation of glass fiber sheet on the test specimen is done with the help of the MBrace Composite Strengthening Resin System which consists of MBrace Primer and MBrace Saturant for effective adhesion of fiber sheet to the concrete surface. The experimental program comprised of testing of a total number of 34 cylindrical specimens having diameter of 150 mm and 300 mm height which included 17 numbers of specimens each for M20 and M40 grade of concrete. All the specimens were wrapped and subjected to axial compressive load after 28 days of normal water curing. Specimens were treated with different wrap positions and number of layers along with introduction of centre crack and edge crack as indicated in Fig. 1. Table 1 describes mechanical properties of E Glass fiber [9] used in the present investigation. Table 2 shows identification and detail of types of specimen with different wrap positions used in the present investigation. The location and size of the cracks are based on the criticality of influence on the effect of wraps. Table 1. Mechanical Properties of E Glass Fiber Sr. No Description of Property Value 1 Density 2.7 g/cm3 2 Tensile Strength 3400 MPa 3 4 Modulus of Elasticity Strain 75 GPa 4.5

Kinjal V Ranolia et. al / Procedia Engineering 51 ( 2013 ) 169 175 171 300 100 Full Wrapping Center Wrapping 100 100 30 30 100 Two Band Wrap Edge Crack Center Crack Fig. 1. Patterns of Fiber Wrapping and Introduction of Crack in Wrap Table 2. Types of Specimen with different Wrap Position Type of Specimen Description of Wrap A B C D E One layer full wrap 100 mm wrap in middle Two layers wrap Edge Crack Centre Crack 3. Discussion of test result All the specimens were wrapped after 28 days of casting ensuring proper curing of the GFRP sheets and then loaded to axial compression. Before testing the specimens, edge crack having lengths of 15 mm and 20 mm and a centre crack having length of 30 mm were made in fiber wrap. All the cylindrical specimens were tested in Universal Testing Machine (UTM) for axial compression. As can be seen from Fig 2, the composite wraps have failed in tension due to bulging of the concrete. No debonding of wraps from concrete surface has been observed as expected under this type of loading. The confined and the unconfined compressive strength of cylinder specimens for M20 and M40 grade concrete are as summarized in Table 3 and Table 4 respectively. The results of M20 and M40 grade of concrete by introducing the edge cracks and centre crack in fiber wrap are as summarized in the Table 5 and Table 6 respectively. Unconfined strength of concrete for M20 and M40 grade of concrete is found to be 24.48 MPa and 45 MPa respectively. Improvement in compressive strength of confined concrete in type A and type B specimens over unconfined concrete of M20 grade is 57.80% and 85.00% respectively which reveals that single layer of wrap is much beneficial compared to two layers as far as economy is concern. Gain in two wrap layers over single layer is only 27.2% which is not benefiting much. Center and two bands wrapping are not recommended being least effective.

172 Kinjal V Ranolia et. al / Procedia Engineering 51 ( 2013 ) 169 175 Table 3. Compressive Strength of M20 Concrete with different Wrap Positions and Types Description of Strength One Layer Wrap (A) Two Layers Wrap (B) Wrapping at Centre (C) Two Bands Wrapping (D) Confined Strength (MPa) 38.63 45.29 30.57 33.66 % Gain 57.80% 85.00% 24.87% 37.50% Table 4. Compressive Strength of M40 Concrete with different Wrap Positions and Types Description of Strength One Layer Wrap (A) Two Layers Wrap (B) Wrapping at Centre (C) Two Bands Wrapping (D) Confined Strength (MPa) 55.62 77.42 52.08 54.15 % Gain 23.60% 72.04% 15.73 % 20.33% Table 5. Compressive Strength of M20 Grade Concrete with Introduction of Crack Description of Strength 15 mm edge crack 20 mm edge crack 30 mm centre crack Confined Strength (MPa) Confined Strength with Crack (MPa) 38.63 37.36 38.63 37.08 38.63 32.55 % Loss 3.28% 4.01% 15.73 % Table 6. Compressive Strength of M40 Grade Concrete with Introduction of Crack Description of Strength 15 mm edge crack 20 mm edge crack 30 mm centre crack Confined Strength (MPa) Confined Strength with Crack 55.62 55.20 55.62 54.63 55.62 49.53 (MPa) % Loss 0.76% 1.78% 10.95 % (a) (b) (c) (d) Fig. 2. Failure of Specimens having different Patterns of Fiber Wrapping and Cracking (a)fully Confined (b)fully Confined with edge crack (c)partial Confined Double Band (d)partial Confined Central Band 4. Finite Element Modeling of Concrete Confinement In this present study, a finite element model of FRP confined concrete column was developed and validated by existing experimental results. The models were simulated using ANSYS 10 software. In general, the conclusions and methods would be very similar using other non linear FEA programs. A 3-D layered structural element SOLID 46 was used to model FRP composites. SOLID 46 was selected over shell elements due to the fact that the shell elements would share

Kinjal V Ranolia et. al / Procedia Engineering 51 ( 2013 ) 169 175 173 nodes with the concrete cylinder surface. Such a choice would make introduction of cracks difficult. The element allows up to 250 layers. Initial cracks have been introduced in the model by geometric modelling and subsequent expansion of the cracks has been model by reduced elasticity modulus of the wraps after failure. The element has three degrees of freedom at each node: translation in x, y, z directions. The element is defined by eight nodes, layer thickness, layer material direction angles and orthotropic material properties. For the modelling of concrete, a 3-D concrete solid element SOLID 65 was used. It can be used with or without reinforcing bars. The solid is capable of cracking in tension and crushing in compression. The element is defined by eight nodes having three degrees of freedom at each node: translations in x, y, z directions. The element allows application of different isotropic material properties for tensile and compressive stress domains. The material properties of the FRP composites are calculated using micro mechanics approach as given below. E x = E 1 ; E y = E 2 ; E z = E 3. μ xy = μ 12 ; μ yz = μ 23 ; μ zx = μ 31. G xy = G 12 ; G yz = G 23 ; G zx = G 31. From the rule of mixtures; E 1 = E f V f + E m V m E m E f E 2 = E m V f + E f V m Where, E f = Modulus of elasticity of the Fiber E m = Modulus of elasticity of the Matrix V f = Volume fraction of fiber and V m = Volume fraction of matrix Similarly the shear modulus can be calculated, G m G f G 12 = G m V f + G f V m Where G m = shear modulus of matrix, G f = shear modulus of fiber, μ 12 = V f μ f + V m μ m Where μ f The relation between m 12 = 21 E 1 E 2 For FRP composite as defined by the element, the input data used are the number of layers, thickness of the layers and orientation of fiber direction for each layer. The composite is orthotropic in nature therefore; nine different properties have to be the input i.e. the elastic modulus in three different directions (Ex, Ey, Ez), the shear modulus in the three directions (Gxy,Gyz,Gzx in the three xy yz zx ). To obtain isotropic material properties for concrete, the elastic modulus (Ex f ck (MPa) xy) of 0.15 are taken for input to the element along with the values of ultimate tensile strength and ultimate compressive strength. (a) (b) (c) (d) Fig. 3. FEM Modeling of various Specimens (a) Fully Confined Concrete (b) Centrally wrapped Concrete(c) Double Band Wrapped (d) Loading and Boundary Conditions

174 Kinjal V Ranolia et. al / Procedia Engineering 51 ( 2013 ) 169 175 When a FRP wrapped concrete column is subjected to a compressive load, concrete will be the initial load bearing member of the structure. The compressive load initiates micro-cracks in the concrete as shown in Fig. 4 (a). The concrete crushes when its ultimate compressive strength is reached. ANSYS is able to demonstrate the cracking and crushing of the concrete for an applied load. Fig. 4 (b) shows the concrete crushing and cracking; the octagons represent crushing and the circles represent the cracking in the concrete. The FRP starts confining the concrete column, when the concrete reaches its ultimate compressive strength. Thus, the FRP and the concrete core will carry the load collaboratively. The failure in the structure occurs when eventually the FRP fails. (a) (b) Fig. 4. Failure indicated by FEA Modeling (a) Initial Cracking in Fiber Wrapping (b) Cracking and Crushing of Concrete The comparison between the experimental results and the results predicted by FEA without introduction of crack in the fiber is tabulated in Table 7 which shows that the FEA results have good agreement with experimental results. Table 7. Compressive Strength of M40 Grade Concrete with Introduction of Crack No. Description Confined Strength (MPa) Exptl. Confined Strength (Mpa) FEA % Error 1 One layer 38.63 36 6.8 2 Two layer 45.29 46-1.57 M20 3 Centre wrap 30.57 32-4.67 4 Two band wrap 33.66 34-1.01 5 One layer 55.62 58-4.27 6 M40 Two layer 77.42 79-2.04 7 Centre wrap 52.08 54-3.68 8 Two band wrap 54.15 55-1.56

Kinjal V Ranolia et. al / Procedia Engineering 51 ( 2013 ) 169 175 175 5. Conclusion The confined concrete strength is essentially dependent on the maximum confining pressure that the FRP can apply. The FRP confinement increases the axial load carrying capacity of concrete structures. Better confinement was achieved when concrete cylinders were fully confined with GFRP than partially confined specimens. The confinement effectiveness increases with increase in the number of layers/wrap. Better confinement was achieved when number of the layers of GFRP was increased, resulting in enhanced load carrying capacity. This is due to larger area available to provide hoop action. The failure of the specimens took place in the middle half region of the specimens when full confinement was provided and it took place at top and bottom portion in case of partially confined specimens. Crack in FRP layer affects the compressive strength of concrete. Crack location and crack length affects differently to compressive strength of concrete. Loss in compressive strength is more in specimens with centre crack than specimens with edge crack. From the literature referred it is found that the confinement models developed for concrete columns confined with steel tend to over predict the strength enhancement when applied to the FRP confined concrete columns. This is mainly because of the behavioral difference between the two materials, that is steel and FRP.Steel being an elasto-plastic material, exerts a constant confining pressure after its yield. While FRP, being a linearly elastic material, confines the concrete with an ever increasing confining pressure until its rupture. Results obtained by 3-D FEA modeling shows good agreement with the experimental results. References [1] Ciupala et al., ty of Sheffield, Sheffield, UK. [2] Lee C., Bonacci J. F., Thomas M. D. A., Maalej M., Khajehpour S., Hearn N., Pantazopoulou S. and Sheikh S., 2000., Canadian Journal of Civil Engineering, Vol. 27, No. 5, pp. 941-948. [3] Li G., Hedlund S., Pang S., Alaywan W., Eggers j. and Abadie C., 2003. Composite Part B: Engineering, Vol. 34. [4] Masoud S. and Soudki K. May 2002. - of the 2nd International Conference on Durability of Fiber Reinforced Polymer Composites for Construction, Montreal, pp. 113-126. [5] Meh Ph. D Thesis, Civil and Environmental Engg. Dept., Arizona State University, USA. [6] Rochette, P., and Labossiere, P. 1996. "A plasticity approach for concrete columns confined with composite materials." Adv. Composite Mater. in Bridges and Struct., El-Badry, M. M.(Ed.), CSCE, 359-366. [7] Shilpa K., Panda G. and Kumari Mamta, 2010. Materials Engineering, National Institute of Technology, Rourkela. [8] Watanabe K. et al. 1997. "Confinement effect of FRP sheet on strength and ductility of concrete cylinders under uniaxial compression", Proceedings of the Third International Symposium, Vol. 1, Sapporo, Japan, pp. 233-238. [9] Kaw A.