Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

EXPERIMENTAL EVALUATION OF FULL-SCALE FRP-CONFINED REINFORCED CONCRETE COLUMNS

FRP Anchorage Systems for Infill Masonry Structures

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

INNOVATIVE ASSET MANAGEMENT. Research Project C. Challenges in Keeping Bridges in Good Operation Condition

PASSIVE AND ACTIVE NEAR-SURFACE MOUNTED FRP RODS FOR FLEXURAL STRENGTHENING OF RC BEAMS. Abstract

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

BEHAVIOUR OF RC BEAMS STRENGTHENED WITH NSM STEEL AND CFRP BARS

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

CONCRETE SUBSTRATE PREPARATION AND CHARACTERIZATION PRIOR TO ADHESION OF EXTERNALLY BONDED REINFORCEMENT

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

Structural Upgrade of Reinforced Concrete Column-Tie Beam Assembly using FRP Composites

Retrofitting of Reinforced Concrete Beam with Externally Bonded CFRP

Flexural strengthening of reinforced concrete beams using externally bonded FRP laminates prestressed with a new method

OUT OF PLANE BEHAVIOR OF MASONRY INFILL WALLS RETROFITTED WITH A REINFORCED POLYMER GRID AND POLYUREA SYSTEM

Mechanical Behaviour of Concrete Beams Reinforced with CFRP U- Channels

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

LOAD TEST EVALUATION OF FRP-STRENGTHENED STRUCTURES

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Advantages of Incorporating Fiber Reinforced Polymers into the Earthquake Safety Program for the Bay Area Rapid Transit (BART)

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

AFFECT OF ENVIRONMENTAL CONDITIONS DURING INSTALLATION PROCESS ON BOND STRENGTH BETWEEN CFRP LAMINATE AND CONCRETE SUBSTRATE

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

Tests on FRP-Concrete Bond Behaviour in the presence of Steel

Reviewing the FRP Strengthening Systems

AFRP retrofitting of RC structures in Japan

Finite Element Analysis of CFRP Strengthened Concrete Beams

Shear strengthening of RC deep beams with circular openings using externally bonded SFRP composites

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

International Journal of Advance Research in Engineering, Science & Technology

FRP REPAIR TECHNIQUES FOR R.C. BEAMS PRE-DAMAGED IN SHEAR

3. TEST METHOD FOR BOND PROPERTIES OF CONTINUOUS FIBER SHEETS TO CONCRETE (JSCE-E )

Debonding Behavior of Skew FRP-Bonded Concrete Joints

Effect of Near Surface Mounted (NSM) Steel Bars on Shear Strength of RC Beams

EFEECT OF GFRP BELT TO THE FAILURE MODE OF CRACKED CONCRETE BEAMS STRENGTHENED USING GFRP SHEET

SHEAR AND BUCKLING STRENGTHENING OF STEEL BRIDGE GIRDER USING SMALL-DIAMETER CFRP STRANDS

Special Inspections for Externally Applied FRP: How Much is Enough? Peter B. Larson P.E. SECB

Unidirectional Carbon Fibre Anchorage Length Effect on Flexural Strength Capacity For Concrete Beams

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

Repair & Rehabilitation of Initially cracked RCC Beams by CFRP

Shear Strengthening Reinforced Concrete Beams with Externally bonded Fiber-Reinforced Polymer: Updated Data Base

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

PRE-CONSTRUCTION INVESTIGATION FOR THE REHABILITATION OF A BRIDGE USING INTERNAL FRP TECHNOLOGIES

Construction. Carbon fiber shear links for structural strengthening. System Description. (Template for local translation, only for internal use)

Performance of NSM FRP strengthened concrete slabs at low temperatures

Strengthening Highway Bridges with CFRP Composites

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

Experimental bond behavior in masonry elements externally reinforced with FRP laminates

USE OF ANCHORS IN SHEAR STRENGTHENING OF REINFORCED CONCRETE T-BEAMS WITH FRP

BOND PERFORMANCE OF STEEL REINFORCED POLYMER AND STEEL REINFORCED GROUT

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Strengthening of an Impact-Damaged PC Girder

Strengthening of Reinforced Concrete Building by Externally Bonded Carbon Fiber System

Fiber-Reinforced Polymer Bond Test in Presence of Steel and Cracks

FRP-strengthened RC Structures

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

RESEARCH ON COMPOSITE STRENGTHENING OF MASONRY ARCHES

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

AN IMPROVED COMPOSITE ANCHORING SYSTEM

BEHAVIOR OF FULL-SCALE SHEAR DEFICIENT CORNER RC BEAM-COLUMN CONNECTIONS RETROFITTED WITH CFRP SHEETS

LATEST ACHIEVEMENT IN TECHNOLOGY AND RESEARCH OF RETROFITTING CONCRETE STRUCTURES

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

The Effect of Width, Multiple Layers and Strength of FRP Sheets on Strength and Ductility of Strengthened Reinforced Concrete Beams in Flexure

Experimental Investigation on Flexural Behaviour of Corroded R.C Beam Retrofitted with Basalt Fiber Sheet

Flexural and Shear Strengthening Of RC beams with FRP-An Experimental Study

Carbon fibre shear links for structural strengthening

PULLOUT CAPACITY BEHAVIOUR OF FRP-HEADED REBARS

Strengthening of R.C. Beams Using Externally Bonded Plates and Anchorages.

Anchorage Effect on Flexural Fiber Reinforced Polymer (FRP) Laminate Strengthening of Lightweight Concrete Beams

REFURBISHMENT STRUCTURAL STRENGTHENING WITH SIKA SYSTEMS

DESCRIPTION ADVANTAGES

Use of FRP to Strengthen and Repair Marine Structures

IN-PLANE BEHAVIOR OF ALTERNATIVE MASONRY RETROFITTED WITH POLYUREA MEMBRANES

CHAPTER 2 REVIEW OF LITERATURE 2.1 Introduction Reinforced concrete beam-column joints have an important function in the structural concept of many

Comparisons to Tests on Reinforced Concrete Members

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

Carbon Fibre Textile

SURFACE BONDED FRP REINFORCEMENT FOR STRENGTHENING/REPAIR OF STRUCTURAL REINFORCED CONCRETE. Tarek Alkhrdaji and Antonio Nanni

Beam Pull Out Tests of NSM FRP and Steel Bars in Concrete

Carder 1. FABRICATION AND CYCLIC LOADING OF SUPER-ELASTIC SHAPE MEMORY ALLOY REINFORCED POLYMER Rachel Carder

NUTC R Adding Faculty in Transportation Areas - Year 2 & 3: Research Progress on Behavior and Design of Concrete Structures

ARAB REPUBLIC OF EGYPT

DESIGN MANUAL FOR FORTRESS CARBON-KEVLAR STRAP FRP STRENGTHNING COMPOSITE SYSTEM FOR MASONRY STRUCTURES. ESR No ICC-ES AC 125

Behavior of RC Beams Strengthened with Externally Post-Tensioning CFRP Strips

INFLUENCE OF WATER IMMERSION ON THE BOND BEHAVIOR BETWEEN CFRP AND CONCRETE SUBSTRATE

Easy to Use A7 Saves You Time and Money

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

High Strength Epoxy tested in accordance to ICC-ES AC308

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

IMPROVING SHEAR CAPACITY OF RC BEAMS USING EPOXY BONDED CONTINOUS STEEL PLATES

Transcription:

University of Miami College of Engineering Structures and Materials Laboratory CERTIFIED TEST REPORT EVALUATION OF ANCHORING SOLUTION FOR EXTENALLY BONDED FIBER REINFORCED POLYMER (FRP) SYSTEMS Report Number: R-5.10_161206_FSS Date: December 16, 2016 REPORT PREPARED FOR: Mr. Donald Edward Wheatley Fortress Stabilization Systems 184 W 64th St, Holland, MI 49423, USA www.fortressstabilization.com Quality System: The Structures and Materials Laboratory (SML) maintains a quality system in compliance with ISO 17025-2005, accredited under International Accreditation Service (IAS), testing laboratory, TL-478 Procedures: Test Data: All tests and services are done in accordance with the SML Quality Manual (Version 2.4) revised August 31, 2015; relevant standard operating procedures (SOPs); and with the applicable requirements of the reference standard test methods. All the test results presented herein are linked through unbroken chain to the raw data files recorded on the day of the test. Analyzed data is obtained directly from the recorded raw data during testing, from which the test results are presented. This report contains analyzed tabulated data results of each test. University of Miami, College of Engineering, Structures and Materials Laboratory 1251 Memorial Drive, McArthur Engineering Building 108, Coral Gables, FL, 33146 Phone: 305-284-3391 Fax: 305-284-3492 Email: fdecaso@miami.edu

RECORD Page 2 of 11 Controls: Superseded Report Reason for Revision new n/a Effective Date December 16, 2016 Approval Signatures: Quality review Approval I indicate that I have reviewed this and agree with the contents it presents, and find it meets all applicable laboratory requirements and policies. I approve for its release to the customer. Name: Signature: Francisco De Caso Date: December 16, 2016 Technical review Approval I indicate that I have reviewed this and agree with the technical contents it presents, and find it meets all applicable laboratory requirements and policies. I approve for its release to the customer. Name: Signature: Antonio Nanni Date: December 16, 2016

RECORD Page 3 of 11 EXECUTIVE SUMMARY This certified test report, evaluates the performance of a unique anchor solution for externally bonded fiber reinforced polymer (FRP) systems on concrete substrate. The anchor solution is a development composed of two components: i) a flat staple composed of a pre-cured carbon FRP piece and; ii) a saturated fiber sheet piece that wraps around the flat staple anchor and is placed onto the externally bonded FRP sheet or laminate, here in referred to as anchor Type Z. Based on double shear load tests of FRP laminates bonded to concrete per the results reported here, the following can be concluded: When comparing type Z anchor system to an un-anchored FRP laminate bonded to concrete, under the same conditions it improves the load carrying capacity of the FRP laminate by 156%. When comparing type Z anchor system to an FRP laminate bonded to concrete anchored only with the flat staple only component, under the same conditions it improves the load carrying capacity of the FRP laminate by over 115%. The anchor type Z translates the failure to the concrete substrate, fully engaging the FRP laminate system bonded to the concrete. Neither laceration nor debonding of the FRP laminate occurs with anchor type Z, which are unwanted failure modes since they do not fully engage the FRP laminate. In summary the anchor behaves as a single element (coupling both the staple and wrapped piece), and results in an effective anchoring solution as presented herein.

RECORD Page 4 of 11 1. BACKGROUND The use of externally bonded fiber reinforced polymer (FRP systems) is to date a widely used and accepted practice to strengthen, repair and upgrade structures, where the focus of this report is in concrete and masonry structural elements. Strengthening with FRP can be classified in two application categories: contact- and bondcritical. When FRP systems are confining elements, e.g. columns, this are referred to as contact critical applications, where contact between the structural element (i.e. columns) and the FRP system is critical to ensure the effectiveness of the strengthening solution. Bond-critical refers to all other applications where the effectiveness of the FRP system depends on assuring adequate bond between the FRP laminate and the concrete substrate, e.g. flexural and shear strengthening of beams or walls. In bond-critical applications, premature debonding of the FRP system from the substrate is typically the failure more. A proposed solution to counter debonding consists in proving anchorage to the FRP system (fiber sheet or laminate) to the substrate. The solution has proved to be feasible and to significantly improve the efficiency of the FRP strengthening system by allowing it to carry higher loads. A wide variety of anchoring methodologies have been developed and proposed in order to avoid the debonding problem, where the main two solutions are referred to as: U- wrapping or patch anchors and spike anchors. This reports presents a unique anchoring solution for FRP systems consisting of a staple type of anchorage in combination with a piece that wraps around the staple anchor and is placed onto the FRP sheet or laminate, as descried in the next sections. 2. PRODUCT DESCRIPTION The anchoring solution for FRP systems under evaluation presented herein, is an evolution which combines two elements: i) the flat staple composed of a pre-cured carbon FRP piece which transfers loads into the substrate by embedding the legs of the staple into the substrate via cut slits or grooves and; ii) a saturated fiber sheet piece that wraps around the flat staple anchor and is placed onto the FRP sheet or laminate, increasing the contact area to transfer loads from the FRP sheet or laminate to the staple. Refer to Figure 1 for a schematic of the anchoring system as well as the installation on concrete substrate. Characterization tests of the staple anchor alone have been also conducted (without the saturated fiber sheet piece that wraps around the flat staple anchor) to demonstrate the significant effectives of the combined approach. Combining the saturated fiber sheet piece that wraps around the flat staple anchor is only possible due to the geometry and unique layout of the flat staple. No laceration nor debonding of the wrapped piece, or other partial failure modes occur, since the anchoring solution performs as a single element coupling of both the staple and wrapped piece, and results in an effective anchoring solution as presented in this report.

RECORD Page 5 of 11 (a) (b) (c) Figure 1 Anchor solution under evaluation: a) schematic of installation; b) installation steps on concrete substrate; and c) staple anchor (left) and schematic of installation for flexural strengthening on concrete slab element (right)

RECORD Page 6 of 11 3. SCOPE OF WORK The scope of work presented herein aims to evaluate the performance of the aforementioned flat staple anchor solution for externally bonded FRP systems, by testing and comparing the load carrying capacity results of three type of specimens: i) Benchmark Specimen (TYPE B): This is the reference specimen, establishing the specimen layout for all tests consisting of a six-inch (6 in.) wide strip of unidirectional carbon FRP sheet is bonded to a concrete block. No anchoring solution is used in this type of specimen. ii) Staple Only Specimen (TYPE S): Using the same established layout in the benchmark specimen, the bonded FRP sheet is anchored with the flat staple of geometry equivalent to six-inch (6 in.) long, two-inch (2 in.) wide and one-inch deep legs embedded in the concrete. iii) Staple and Wrapped Piece Specimen (TYPE Z): Using the same established layout in the benchmark specimen, and flat staple geometry in the staple only specimen; the bonded FRP sheet is anchored with the flat staple a saturated fiber sheet piece that wraps around the flat staple anchor and is placed onto the FRP sheet or laminate 4. TEST METHODOLOGY Currently, no standard test criterion has been developed to characterize the performance of FRP anchor systems. Nevertheless, there are well-established test methodologies that have been adopted in numerous research studies and published in peer-reviewed papers. The methodology adopted to evaluate the performance of the FRP anchor solution is based on a double shear bond test methodology, where two bonded areas are engaged in shear. To this end, an FRP laminate is bonded to two opposing sides of a concrete block. In the test side the anchor is installed on the FRP sheet, while on the other the FRP sheet is extended and wrapped around the concrete block to provide additional bonded length and anchored to ensure failure is on the test side of the block. The test layout provides a closed loop system, where by a hydraulic jack is inserted in between the concrete block and the opposite end of the FRP laminate. A steel fixture is used to ensure tensile load is distributed evenly on to the FRP laminate, avoiding stress concentration that might result in premature or invalid failure modes. Refer to Figure 2 for a description of the test setup and layout, and Figure 3 where an illustration of the anchor and specimen payout is provided.

RECORD Page 7 of 11 Figure 2 FRP anchor double shear test setup and layout (a) (b) Figure 3 Specimen type Z layout: (a) entire specimen with FRP sheet; (b) close up of bonded end to concrete showing staple and wrapped piece.

RECORD Page 8 of 11 5. TEST INFORMATION Specimen preparation: Specimen geometry: Test Location: Test setup: Specimen Conditioning: Specimen ID: All specimens were prepared by Structures and Materials Laboratory personnel, following manufactures instructions. All concrete blocks used in testing were cast in a single batch conforming to ASTM C192/C192M-13a, to ensure validity on the comparison of the test results. Concrete substrate surface was prepared via sandblasted to ensure a minimum surface roughness of CPS 3, as defined by ICRI was achieved. The FRP laminate and anchors were installed on the substrate simultaneously. Geometry of test area is provided in Figure 4. All geometry was kept consistent to ensure validity on the comparison of the test results. Structures and Materials Laboratory, SML, University of Miami, 1251 Memorial Dr., MEB108 Coral Gables, FL, 33146 Load was applied via hydraulic jack manually to a quasi-constant rate. All load measurements were recorded with a load cell conforming to ASTM E4-16. After installation of the FRP laminate and anchor on the concrete substrate, the specimens were left to cure for a minimum period of 5 days. Following that, specimens were brought into the laboratory to become temperature balanced for a minimum period of 24 hours at 23 ± 1 C (73 ± 3 F) and 60 ± 5% RH. Specimens are labeled and uniquely identified for quality and traceability using the format T_XX, where T is the specimen type (B for benchmark, S for staple only, and Z for staple and wrapped piece specimen) product, and X is the sample number. Figure 4 Specimen test area geometry

RECORD Page 9 of 11 6. TEST RESULTS SPECIMEN ID Total peak load (P max) Table 1- Test Results for FRP Staple Anchor Solution Total load sustained by Increase in anchor performance (P max/2) Failure Mode lbf kips lbf kips % B_01 13041 13.04 6521 6.52-19.7 FRP de-bonding B_02 17034 17.03 8517 8.52 4.9 FRP de-bonding B_03 18635 18.63 9317 9.32 14.8 FRP de-bonding Average 16237 16.24 8118 8.12 Stand. Dev. 2352 2.35 1176 1.18 0.0 Coef. of Var. (%) 14.5 14.5 14.5 14.5 S_01 24628 24.63 12314 12.31 51.7 FRP de-bonding and slippage beneath the anchor S_02 30118 30.12 15059 15.06 85.5 FRP de-bonding and slippage beneath the anchor/frp rupture S_03 29170 29.17 14585 14.58 79.7 FRP de-bonding and slippage beneath the anchor/frp rupture Average 27972 27.97 13986 13.99 Stand. Dev. 2396 2.40 1198 1.20 72.3 Coef. of Var. (%) 8.6 8.6 8.6 8.6 Z_01 34480 34.48 17240 17.24 112.4 Failure in concrete substrate Z_02 43131 43.13 21566 21.57 165.6 Anchor failure and FRP de-bonding Z_03 45927 45.93 22964 22.96 182.9 Failure in concrete substrate Z_04 41412 41.41 20706 20.71 155.1 Failure in concrete substrate Z_05 42833 42.83 21417 21.42 Anchor failure and FRP de-bonding Average 41556 41.56 20778 20.78 Stand. Dev. 3829 3.83 1915 1.91 155.9 Coef. of Var. (%) 9.2 9.2 9.2 9.2

RECORD Page 10 of 11 (a) (b) Figure 5 Specimen representative failure modes: a) Failure in concrete substrate FRP de-bonding; and b) slippage beneath the anchor

RECORD Page 11 of 11 7. CONCLUSIONS This certified test report, evaluates the performance of an anchor solution for externally bonded fiber reinforced polymer (FRP) systems on concrete substrate. The anchor solution is a development composed of two elements: a) a flat staple composed of a pre-cured carbon FRP piece and; b) a saturated fiber sheet piece that wraps around the flat staple anchor and is placed onto the externally bonded FRP sheet or laminate. To this end, the experimental comparison of three test specimen types was undertaken including: i) benchmark specimen only with the FRP laminate bonded to concrete (no anchoring); ii) a specimen with the FRP laminate anchored only with the staple anchor to concrete; and iii) a specimen with the laminate anchored with the staple anchor and wrapped piece. Characterization tests using a double shear methodology to apply tensile load on the FRP laminate to evaluate the capacity of anchored FRP system. The results are provided in Table 1 and demonstrate the improved effectiveness at anchoring the FRP laminate on to the concrete, where a 72% increase in load carrying capacity is measured for the anchor alone, and 156% for the anchor when wrapped piece, when compared to no anchor provided. Furthermore, the improved performance of anchor type Z, compared to type S, which couples the anchor with the wrapped piece, provides over 100% increase in load carrying capacity. Combining the saturated fiber sheet piece that wraps around the flat staple anchor is only possible due to the geometry and unique layout of the flat staple. Neither laceration nor debonding of the FRP laminate occurs with anchor type Z, this is not the case for anchor type S, as reported in Table 1, which are unwanted failure modes since they do not fully engage the FRP laminate. The anchor type Z translates the failure to the concrete substrate, fully engaging the FRP laminate systems bonded to the concrete, showing that anchor type Z behaves as a single element (coupling both the staple and wrapped piece), and results in an effective anchoring solution as presented in this report. The tests presented herein are true representations of the anchor solutions and FRP systems, where the coefficient of variance are in the range normal to the type of experimental testes undertaken. All results are traceable to NIST values. END OF TEST REPORT