Thermo Scientific KIEL IV Carbonate Device

Similar documents
Chrom-Card Data System. A simple, chemist-oriented data handling system...productive from the first day!

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

TRACE GCxGC. Comprehensive Two Dimensional GC. Unmatched separation capability for complex samples

Thermo Scientific TriPlus Autosampler

Thermo Scientific DFS High Resolution GC/MS Designed for Highest Sensitivity

AOX/TOX, EOX and POX analyzers; DEXTAR, ECS 1200 and ECS Total Halogen expertise fulfilling your Environmental analytical needs

LTQ Orbitrap XL Hybrid FT Mass Spectrometer Unrivaled Performance and Flexibility

Thermo Scientific PAiNACEA Suite of Solutions

TriPlus Autosampler. Flexible Sampling Solutions

Thermo Scientific EASY-nLC 1000 Effortless, Split-free Nano-flow UHPLC for Top Performance in LC-MS

Thermo Scientific FLASH 2000 Series Organic Elemental Analyzers

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific TSQ Quantum XLS Ultra Triple Quadrupole GC-MS

Nitrogen Determination in Soils and Plants by Flash Combustion using Argon as Carrier Gas

Total Chlorine Analyzer ECS 1200/ ECS Many Applications, One Solution

Thermo Scientific Accela LC Systems

single-use fermentors

Thermo Scientific Evolution Array UV-Visible Spectrophotometer

Thermo Scientific Evolution Array UV-Visible Spectrophotometer

Thermo Scientific ARL X TRA Powder X-ray Diffraction System Uncompromised Intensity and Resolution

Isotope Ratio MS. Continuous Flow. Consumables and Spare Parts for Thermo Scientific Elemental Analyzers

Thermo Scientific ARL Fire Assay Analyzer Optical Emission Spectrometer

Thermo Scientific Transcend System

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Multi-element determination in pharmaceutical preparations using the Thermo Scientific icap Q ICP-MS

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Your local gas generation partner. i-flowlab. Scalable, high-flow, high-purity nitrogen gas solution for laboratories.

Thermo Scientific Dionex ICS-900 Ion Chromatography System

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

Jonathan R. Beck and Charles T. Yang; Thermo Fisher Scientific, San Jose, CA

ARL Fire Assay Analyzer Optical Emission Spectrometer. Fast analysis of fire assay lead buttons with ultimate performance

Multidrop. The most precise and reliable reagent dispensing solution. Analyze Detect Measure Control TM

for water and beverage analysis

Thermo Scientific TSQ Quantum Access MAX

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

Thermo Scientific DSQ. II Series Single Quadrupole GC/MS. Redefining Productivity in the Workplace

Bringing custom solutions and contract manufacturing to life

Determination of 1,4-Dioxane in Drinking Water by Gas Chromatography/Mass Spectrometry (GC/MS) with Selected Ion Monitoring (SIM)

PRODUCT INFORMATION PLB PRECISE LOCALIZATION OF PARTS IN BINS. Robot guidance systems

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

ARL X TRA Powder X-ray Diffraction System. Uncompromised Intensity and Resolution

Simple, fast and reliable analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Thermo Scientific Heraeus Cytoperm 2 CO 2 and CO 2 /O 2 Incubator

The Benefits of SOLAμ Technology in Sample Preparation. Jon Bardsley and Ken Meadows Thermo Fisher Scientific, Runcorn, UK

i-flow Scalable, high-flow, nitrogen generation solution for industry

i-flow Scalable, high-flow, nitrogen generation solution for industry

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography


TECHNICAL INFORMATION

DSQ II GC/MS Series. Redefining Productivity in the Workplace. Sensitivity and large dynamic range for demanding environmental analyses

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Analysis of Fracking Flowback Water From the Marcellus Shale Using In-line Conductivity, Automated Dilution, and Ion Chromatography

CYTOPERM 2 CO 2 - AND CO 2

PRODUCT INFORMATION. DWS Pallet MEASURING AND WEIGHING PALLETS AND OTHER BULKY FREIGHT ITEMS. Track and trace systems

no matter the culture we have a solution

Thermo Scientific ARL 9900 IntelliPower Series ARL 9900 X-ray WorkStation

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

PRODUCT INFORMATION PLR 3D LOCALIZATION OF PARTS IN CARRIERS. Robot guidance systems

Thermo Scientific EASY-nLC 1000 System. Effortless, split-free nanoflow UHPLC Top performance in LC/MS

electrochemical detection

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition

Thermo Scientific EASY-Spray Technology. Plug-and-spray with. State-of-the-art performance

OMNIC Software Suite. Full-Featured FT-IR, NIR & Raman Spectroscopy Software

Thermo Scientific Evolution 260 Bio UV-Visible Spectrophotometer

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water. Pranathi R Perati Thermo Fisher Scientific, Sunnyvale, CA, USA

TriStar II Plus Surface Area and Porosity Analyzer

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water

The CDS 7000 E Purge & Trap Concentrator

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

Quantitative Analysis of Wheat Flour Using FT-NIR

Customer Responsibilities

Model TEM Mill. Tabletop precision preparation for producing high-quality TEM specimens from a wide variety of materials EXCELLENCE MAGNIFIED

GDMS. High Resolution GDMS.

CEAST HDT Vicat Series. Thermo-Mechanical Systems

Thermo Scientific Heracell VIOS 160i CO 2. Incubator with Cell Locker System. Protected chambers for your most sensitive cells

Claudio De Nardi, 1 Marta Kozak, 2 David Kasper 3 1. Thermo Fisher Scientific, Dreieich, Germany; 2 Thermo Fisher Scientific, San Jose, CA (USA); 3

NEW: Element Vertical Lift Module

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

GRI Sustainability Reporting Statistics Publication year By Report Services

Lebedev A, 1 Damoc E, 2 Makarov A, 2 Samguina T 1 1. Moscow State University, Moscow, Russia; 2 ThermoFisher Scientific, Bremen, Germany

CE Oligonucleotide Analysis Kit Instruction Manual

Determination of Inorganic Anions in Acid Rain Using a Dedicated High-Pressure Capillary Ion Chromatography System

TurboMatrix Headspace and Headspace Trap Samplers

OmniStar and ThermoStar

rios Water Purification system The standard for laboratory-grade water

EDS Phase Mapping of a Contact Metamorphosed Calc-Silicate Rock

STERIS Continuous Effluent Decontamination (CED) System

Transcription:

m a s s s p e c t r o m e t r y Thermo Scientific KIEL IV Carbonate Device Ultimate Isotope Precision for Carbonates Part of Thermo Fisher Scientific

KIEL IV Carbonate Device Ultimate Isotope Precision for Carbonates Ultimate Isotope Precision The Thermo Scientific KIEL IV Carbonate Device provides fully automated long term performance at ultimate isotope precision for more than 10,000 samples per year. Isotope ratio analysis of carbonate samples is increasingly important in paleoclimatic reconstructions. The requirement for isotope ratio analysis of small samples of carbonate arose in studies of biogenic carbonates (e.g. foraminifera, bivalves, brachiopods, otoliths, corals). Studies of carbonates from growth zones of individual organisms and high resolution studies of microfossils from drill cores require an analytical system which can provide both high throughput and high performance in precision and accuracy over a large dynamic range of sample size. The KIEL IV Carbonate Device coupled to either the 10-kV Thermo Scientific MAT 253 or the 3-kV DELTA V isotope ratio mass spectrometer meets the requirements of such work by providing the highest linearity at highest sensitivity, while enabling high throughput through full automation of the analytical process, from the reaction to the reporting of measurement results. Unique temperature controlled reaction cabinet for ultimate isotope precision of carbonates Two independent reaction lines with acid dosing valves for high sample throughput New microvolume ensuring viscous flow of CO 2 from small samples of carbonate "Fast bellows" strategy reducing CO 2 sample consumption during standard-to-sample pressure adjustment Total process control and data log file for complete insight to all preparation and measurement processes at any time Time slicing for realtime information of data acquisition with a resolution up to 80 data points per integration cycle

for Carbonates Inside Views of the KIEL IV Carbonate Device The inside views of the temperature controlled reaction cabinet (top) and the gas trapping and cleaning cabinet (bottom) show: The connection to four vacuum pumps for vial pre-evacuation The connection of reaction region and first trap The connection to high vaccum region for first trap and microvolume evacuation Operation of the KIEL IV Carbonate Device The KIEL IV Carbonate Device consists of a thermostated reaction region, a trapping and gas cleaning system and a microvolume inlet system. The KIEL IV Carbonate Device uses the principle of the individual acid bath for conversion of carbonates to CO 2. Storage, transfer and chemical reaction of phosphoric acid at elevated temperatures are operated under full temperature control. Septum-free vials are used for the phosphorolysis of the carbonates. All CO 2 released is transferred and processed in an all-metal sealed cryogenic trapping system. Easy accessible unit for sample vial loading and pump maintenance Fast sample tray exchange for continuous operation Bake out of the complete pneumatic valve system and all stainless steel gas preparation and transfer systems Dual process strategy with preparation and sample measurement achieves high sample throughput All stainless steel construction for ultra-high vacuum Ultra-high vacuum closure using gold sealed pneumatic valves 1/8 to 1/4 connections assuring highest pumping efficiency Fibreline optics guarantee ground-loop-free operation CO 2 Sample Gas Preparation and Transfer The reaction of carbonates with phosphoric acid produces CO 2 and H 2 O plus non-condensable gases from impurities in the sample. The cryogenic trapping system consists of a temperature controlled first trap with associated valves, ultra-high vacuum system, pressure gauge and a microvolume. Carbonate samples, phosphoric acid storage, acid transfer and chemical reaction under identical conditions in a precision temperature controlled oven (+/- 0.1 C) Storage of phosphoric acid in a 500 ml reservoir in the thermostated environment of the KIEL IV to keep the acid under absolutely dry conditions and for a long measurement period Additional drying storage of prepared sample vials in the same temperature controlled environment as sample analysis (+/-0.1 C) Full temperature controlled and CO 2 memory-free individual acid bath reaction System uses 105% dry phosphoric acid Septum-free and reusable borosilicate vials Fully observable vial content at any time High sample throughput for high precision carbonate analysis (46 samples a day) Drop test under vacuum and reaction conditions before chemical reaction Control and monitoring of ultra-high vacuum in the complete reaction and preparation system Automated high vacuum system check before each sample reaction from the sample vial to the CO 2 freezing trap

Thermostated Reaction Region Gas Transfer and Purification Microvolume Inlet System Vent H 3 PO 4 Acid Dosing Valves First Trap Precision Pressure Gauge Microvolume Crimp Isotope Ratio MS Drop Counter Forevacuum Gauge Expansion Volume Sample Vial Helium Forevacuum Pump Turbo Pump Schematic of the KIEL IV Carbonate Device In the first step, CO 2 and H 2 O are trapped into the first automated liquid nitrogen trap at -190 C while any non-condensable gases are removed. The CO 2 is then released at -90 C for transfer into the microvolume, while the water is completely retained in the first trap. Based on the pressure of the released CO 2 the Isodat software suite defines the portion of CO 2 being transferred into the microvolume. This software process assures the optimal sample gas pressure in the Isotope Ratio MS. In parallel the reference gas bellow in the dual inlet is pre-adjusted to the expected inlet pressure. Low liquid nitrogen consumption (0.5L/sample) by automated liquid nitrogen refill into a low volume Dewar with a new level detector mechanism High throughput of carbonate in routine operation (> 10,000 analyses per year) with the only consumable being LN 2 Redesigned trapping and gas cleaning system with new transfer line, LN 2 level indicator and trap temperature control Water and temperature resistant compact cartridge design which includes both the temperature sensor and heating cartridge Perfect temperature regulation through direct positioning of the cartridge to the spot of sample freezing CO 2 sample yield determination with a precision pressure gauge at the first trap Complete bake-out of the system Sample Analysis and Referencing The microvolume is heated to +30 C releasing the CO 2 via a dedicated stainless steel capillary to the changeover valve and into the IRMS for d 13 C and d 18 O analysis. In parallel, water is removed from the gas cleaning and trapping system by baking the first trap and evacuating all valves and gas lines. New small microvolume inlet systems for KIEL IV and Dual Inlet New microvolume design for smallest amount of samples with highest precision (e.g. in the range of 6 µg to 130 µg)* Regulated CO 2 transfer to the KIEL IV microvolume to achieve the desired inlet pressure for measurement Same CO 2 sample gas flow from the chemical reaction to the IRMS guarantees the principle of identical treatment of samples Fast bellow reference gas pressure pre-adjustment using the CO 2 sample yield determination Highest precision isotope measurements with a dedicated stainless steel inlet capillary *See Thermo Scientific Application Note AN30176 An overall external precision of 0.04 for d 13 C and 0.08 for d 18 O using the Thermo Scientific MAT 253 is reached for samples greater than 20 µg. In routine operation, laboratories have shown throughputs up to 15,000 analyses per year with the only consumable being LN 2.

for Carbonates The KIEL IV Carbonate Device uses the principle of individual acid baths. Storage, transfer and chemical reaction of phosphoric acid at elevated temperatures operate under full temperature control. CO 2 evolves in septum-free vials and diffuses under medium vacuum pressure into a cryogenic trapping system. Water and noncondensable gases evolved during phosphorolysis are removed from the CO 2 gas phase under high vacuum in the first trap. Prior to transfer into the microvolume, the CO 2 pressure is monitored and, if required, the CO 2 sample size can be reduced by expansion into a defined volume. In the microvolume, the dry CO 2 is prepared for analysis in a dual microvolume inlet system which features a new design of the microvolume on the sample side. An overall precision of 0.04 for d 13 C and 0.08 d 18 O is reached for samples greater than 20 µg. In routine operation, laboratories have shown throughputs up to 15,000 analyses per year with the only consumable being LN 2. The savings achieved by eliminating the requirement for new septa every 1,000 samples is considerable. Fully Automated Long Term Isotope Precision Analytical Performance With a sample size of > 20 µg for MAT 253 or > 40 µg for DELTA V and MAT 253, the following performance for one fuil autosampler run (46 sampies) will be achieved. EXTERNAL PRECISION 1 σ Carbon ( 13 C/ 12 C) 0.04 Oxygen ( 18 O/ 16 O) 0.08 For more details on analytical performance, please contact your local sales representative.

Installation Requirements THERMO SCIENTIFIC KIEL IV CARBONATE DEVICE Instrumentation The KIEL IV Carbonate Device connects to Thermo Scientific MAT 253 and DELTA V stabie isotope ratio MS equipped with a dual inlet system. Liquid Nitrogen 0.5 L/sample Optional: 90 L Dewar for long term operation Compressed Air 350 to 500 kpa (50 to 75 psi) Gases Helium or argon, about 15 ml per sample (for pressurized release of sample containers from reaction position) Power 50/60 Hz Voltage 230V, single phase, 10A = 2,200 Watt Environment Ambient temperature between 18 C and 28 C, with a relative humidity between 20 and 70% Dimensions 90 cm (width) x 90 cm (depth) x 190 cm (height) Weight approx. 100 kg (220 lbs.) Laboratory Solutions Backed by Worldwide Service and Support Tap our expertise throughout the life of your instrument. Thermo Scientific Services extends its support throughout our worldwide network of highly trained and certified engineers who are experts in laboratory technologies and applications. Put our team of experts to work for you in a range of disciplines from system installation, training and technical support, to complete asset management and regulatory compliance consulting. Improve your productivity and lower the cost of instrument ownership through our product support services. Maximize uptime while eliminating the uncontrollable cost of unplanned maintenance and repairs. When it s time to enhance your system, we also offer certified parts and a range of accessories and consumables suited to your application. To learn more about our products and comprehensive service offerings, visit us at www.thermo.com. In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Africa-Other +27 11 570 1840 analyze.sa@thermo.com Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50 34 0 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 530 8447 analyze.ca@thermo.com China +86 10 8419 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com Europe-Other +43 1 333 50 34 0 analyze.emea@thermo.com Finland / Norway/Sweden +46 8 556 468 00 analyze.se@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 608 276 5659 analyze.la@thermo.com Middle East +43 1 333 50 34 0 analyze.emea@thermo.com Netherlands +31 76 579 55 55 analyze.nl@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 914 845 965 analyze.es@thermo.com Switzerland +41 61 716 77 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com Thermo Fisher Scientific (Bremen) GmbH Management System Registered to ISO 9001:2008 2009 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR30178_E 10/09C