Rotokawa geothermal combined-cycle power plant

Similar documents
NOTICE CONCERNING COPYRIGHT RESTRICTIONS

PROJECTS AND CHALENGES STRASBOURG 2006 ORMAT

Binary Power Plants in New Zealand

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

20/06/2011 Seminar on Geothermal Exploitation Santiago de Chile

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Geothermal Power Plant

Geothermal Steam Turbines for Various Purposes

NGAWHA GEOTHERMAL FIELD EXPANSION PROJECT. GEOTHERMAL FLUID CONVEYANCE SYSTEM

RESPONSE OF OLKARIA EAST FIELD RESERVOIR TO PRODUCTION

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

OLKARIA III OPERATIONS & MAINTENANCE SIX YEARS OF EXPERIENCE

THE GEOTHERMAL POWER PLANT AT SANJACINTO-TIZATE

WELLHEAD POWER PLANTS

Proven Geothermal Technologies Provide Clean, Reliable Power

LOW-ENTHALPY POWER GENERATION WITH ORC-TURBOGENERATOR THE ALTHEIM PROJECT, UPPER AUSTRIA

Optimization of NCG System Lineups

GEOTHERMAL POWER PLANTS FOR MEDIUM AND HIGH TEMPERATURE STEAM AND AN OVERVIEW OF WELLHEAD POWER PLANTS

Organic Rankine Cycle Configurations

SMALL POWER PLANTS: RECENT DEVELOPMENTS IN GEOTHERMAL POWER GENERATION IN NEW ZEALAND

Turboden, a Presentation of Recent Worldwide Developments and the Latest Technical Solutions for Large-Scale Geothermal ORC Power-Plants

Geothermal Use in New Zealand

DOBBIE ENGINEERS LTD

Low enthalpy power generation with ORC- Turbogenerator The Altheim Project, Upper Austria

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Geothermal Energy and Electricity Generation The New Zealand Success Story

Scaling Protection Technology for Hachijyo-Jima Geothermal Power Plant

Performance Improvement of Single-Flash Geothermal Power Plant Applying Three Cases Development Scenarios Using Thermodynamic Methods

Magma On the other hand, molten rock is under active volcanoes at accessible depths. The temperatures excess 650 o C.

INTEGRATION OF A NEW CCGT PLANT AND AN EXISTING LNG TERMINAL AT BARCELONA PORT Abstract ID Number: 155

UPDATE REPORT ON THE EXISTING AND PLANNED USE OF GEOTHERMAL ENERGY FOR ELECTRICITY GENERATION AND DIRECT USE IN NEW ZEALAND

TransPacific Energy Advantage: Case Studies

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

OPERATIONAL EXPERIENCE GAINED ON REHABILITATION OF THE ALUTO LANGANO GEOTHERMAL POWER PLANT

Geothermal Power Plant

Complete cooling performance. Air cooled exchangers for the oil, gas and power markets

Water Dependency of Geothermal Power Generation Systems

Bringing the Neal Hot Springs Geothermal Power Plant to Life

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

UPCOMING GEOTHERMAL ENERGY DEVELOPMENT IN NEW ZEALAND

SARULLA GEOTHERMAL PROJECT

ORMAT Nevada, Inc. Expansion and Improvements Raise Power Production 20%

AUSTRALASIA: GEOTHERMAL REPORT 2015

Custom Systems Built to Exacting Client Specification

enertime CLEAN ENERGY HARVESTING THE FRENCH CLEANTECH THAT TRANSFORMS HEAT INTO ELECTRICITY

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Heat recovery from diesel engines and gas turbines

Engr. Adnan Qamar Lecturer Energy Resources

ISOBUTANE GEOTHERMAL BINARY CYCLE SENSITIVITY ANALYSIS

38.5 MW Sleaford Biomass Power Plant under construction, Lincolnshire, the UK. April 2013

GEOTHERMAL POWER PROFILE

VVER-440/213 - The reactor core

DEVELOPMENT OF DOWNHOLE PUMP FOR BINARY CYCLE POWER GENERATION USING GEOTHERMAL WATER

Guidance page for practical work electricity production from geothermal energy

The Geothermal Power Plant at Hellisheiði, Iceland

GNS 2006, 95% C

Thermodynamic Analysis on Gas Turbine Unit

Heat recovery from diesel engines and gas turbines

1. INTRODUCTION. The plant s feed water system needed to be self sufficient to eliminate the need for condensate return fro m SCA.

- 1 - InfraStruXure InRow SC Assembly and Start-Up. Installation Service

Heat recovery from diesel engines and gas turbines

GEOTHERMAL POWER PROFILE

3 core areas of expertise

Ormat Technologies, Inc. Puna Geothermal Venture: Permitting and Operation in Hawaii

PAST, PRESENT AND FUTURE MW additional geothermal capacity Drilling ongoing

Ohaaki Geothermal Power Station Renewing Resource Consents Comparison with Greenfield Development

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

RankineCycler TM. Steam Turbine Power System Sample Lab Experiment Procedure

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

Superior reliable performance. Niagara Wet Surface Air Coolers for fluid cooling and vapor condensing

Submission on Regulating Major Hazards Facilities

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Hachijo-jima Geothermal Power Plant

GEOTHERMAL POWER PLANTS: OPERATION AND MAINTENANCE

MONITORING CRYOGENIC TURBINES USING NO-LOAD CHARACTERISTICS

GEOTHERMAL SPACE COOLING

BINARY POWER PLANT MODELLING AND SENSITIVITY ANALYSIS FOR ELECTRICITY GENERATION FROM AN ENHANCED GEOTHERMAL SYSTEM

GEOTHERMAL SMARTER BINARY SYSTEMS DELIVERED.

Plasson ElectroFusion

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Field Performance Evaluation of the Largest Geothermal Organic Rankine Cycle Plant

Key words: Ethiopia, country update, geothermal exploration, development, pilot power plant

SIMULATION AND PERFORMANCE ANALYSIS OF THE NEW GEOTHERMAL CO-GENERATION POWER PLANT (OV-5) AT SVARTSENGI

Mobile Nitrogen Vaporizer Skid

CO-GENERATION PLANT KUSHA INDUSTRY CO.

31.3 GEOTHERMAL CYCLES

Binary Cycle Geothermal Power Systems

Turbine Island. Nhan Huynh Project Manager, Turbine and its auxiliary systems

ORC Binary solutions for high enthalpy resources. Daniel Jira - GIM Joseph Bonafin Turboden Mitsubishi Heavy Industries

Hitachi H-25 & H-80 Gas Turbine. Bucharest, Apr.23, 2013

Clean Power Solutions Alstom s Geothermal Offering

Developing Geothermal Energy in the Pacific Northwest. The Energy Under Our Feet

COOLING TOWER DESIGN FOR CENTRAL GENERATORS OF CUET, BANGLADESH. Mohammad Sharif Khan, Golam Mainuddin, Abu Sadat Mohammad Sayem, Nadeem Nafis

COMPARISON BETWEEN DUCTILE TEARING ANALYSIS AND LINEAR ELASTIC FRACTURE MECHANICS ANALYSIS

The Steam Machine Energy Recovery from The Most Powerful Machine in the World (1) Prepared by: Langson Energy, Inc. March 2013

Heat recovery from industrial installations

ORGANIC RANKINE CYCLE TECHNOLOGY PRODUCTS AND APPLICATIONS APRIL 2013 EAR 99 - NLR

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENTS AND QUANTITIES

Thermoelectric Design

Transcription:

Bulletin d'hydrogiologie No I7 (1999) Centre d'hydrogiologie, Universid de Neuchritel EDITIONS PETER LANG Rotokawa geothermal combined-cycle power plant by Hilel Legmann Ormat Industries, Ltd., P.O. Box 68, Yavne 81 100, Israel ABSTRACT During the first week of October 1998, the 24 MW geothermal power plant at Rotokawa, New Zealand, completed its first operational year. The project was developed following the deregulation of the electricity market in New Zealand by a New Zealand electricity company and was built, supplied and erected by the Ormat Group of Companies on a turnkey basis. Operating at an average output of approximately 25.5 MW and at a yearly availability d over 96%, the plant bas achieved an unexpectedly high annual output of over 215 GWh, at an operating cost of under 0.3 US $kwh. KEYWORDS Geothermal power plant, combined-cycle, sustainable energy, Maoris Introduction During the first week of October 1998, the 24 MW geothermal power plant at Rotokawa, New Zealand, completed its first operational year. The project was developed following the deregulation of the electricity market in New Zealand by a New Zealand electricity company and was built, supplied and erected by the Ormat Group of Companies on a turnkey basis. Operating at an average output of approximately 25.5 MW and at a yearly availability d over 96%, the plant has achieved an unexpectedly high annual output of over 215 GWh, at an operating cost of under 0.3 US $kwh. The Rotorua-Taupo geothermal region Most of the geothermal activity in New Zealand is of tectonic origin and the heat flows and temperatures are not sufficient for commercial power generation. The major geothermal fields of the Rotorua-Taupo area are identified in figure 1. The Wairakei, Rotokawa, Kawerau and Ohaaki fields have been developed for commercial power production as detailed in Table 1, and the Mokai field is currently being developed by a 60 MW plant.

LEGMAN: ROTOKAWA GEOTHERMAL COMBINED-CYCLE POWER PLANT The Rotokawa geothermal field is a deep high tkmperature field covering 25 sq. km and located approximately 12!an north-east of Taupo (figure 2). Figure 1: Rotorua-Taupo geothermal region Figure 2: Rotokawa geothermalfield. 426 Buiietin d'hydrog6ologie No 17 (1999)

Several previous attempts to develop by different groups a geothermal project at Rotokawa by using a conventional condensing steam turbine have failed. On becoming a partner in the project Power New Zealand undertook a thorough review of the plant configuration and the technology options, and decided to select the more flexible and modular Geothermal Combined Cycle configurations proposed by Ormat using the steam and brine components of the geothermal fluid. This plant configuration uses a back pressure steam turbine and air cooled binary plant to capture the best features of each technology. The turnkey contractor and supplier of the equipment for the 24 MW net output plant were the Ormat Group of Companies. Project design The project bas two production wells of around 2000 meters depth producing two phase fluid which is piped to a separator at the station. Steam is separated from the brine at 23 bar while both the steam and the brine are used for electricity generation. The condensed steam is pumped up to the brine pressure, mixed with the high-pressure brine, and reinjected at gravity pressure. There are three reinjection wells of around 500 meter depth, one of which is one of the original field exploratory wells. To maximize the benefits of the available high pressure steam, a back pressure turbine of 14 MW output is utilized to drop the steam pressure to approximately 1.5 bar. This low pressure steam is condensed in two air cooled binary units of 5 MW output each. Ormat's air cooled Geothermal Combined Cycle Unit configuration, bas the advantage of the low capital cost and the simplicity of the back pressure turbine while condensing the steam takes place in the tube and shell beat vaporizers of the OEC units where steam wetness in the turbines last stage is not a problem. A third 5 MW binary unit, utilizes the hot brine flow released from the separator while cooling it from 219 C to 150 C. The plant configuration is shown in figure 3. Station parameters Predicted performance Average of first operation year Steam turbine output 14 MW 14,5 MW Binary unit output 3x4MW 3x43 MW Net output (average) Annual energy output 24 MW 189 GWh 25,5 MW 215 GWh Bulletin d'hydrogiologie No 17 (1999) 421

Figure 3: Process diagram Heat and mass balance The geothermal steam and brine partial flows have the following design point conditions: Steam flow rate NCG flow rate Steam wetness ex separator Steam pressure separator outlet Steam temperature separator outlet Brine flow rate Brine inlet temperature Brine outlet temperature Design ambient air temperature Steam rate t/hr 130 t/hr 3.1 % 99.98 bara 23.2 "C 219.4 t/hr 303 "C 217.5 "C 150 OC 12 tilulmw 5.15 428 Bulletin d'hydrogdologie No 17 (1999)

Main equipment description The steam turbine is a back pressure multi-stage reaction-type turbine. The turbine housing, shaft assembly and nozzle ring were redesigned to Ormat s specification for operation with geothermal steam. LEVEL I STEAM TURBINE & GENERATOR Steam turbine type Steam inlet pressure Steam outlet pressure Speed Multi stage, single cylinder reaction 22.3 bara 1.5 bara 3000 rpm Construction Horizontal split casing Generator rated output 15 MW Voltage 1 lkv, 3 phase, 50 Hz Power factor 0.85 (lagging) Efficiency 91.5% Level II Ormat Energy Converter Organic vapor turbine type Impulse Speed 1500 rpm Construction Horizontal (overhung) vertical split casing Number of stages 2 Motive fluid Pentane Generator rated output 5 MW Voltage 11kV 3 phase, 50 Hz Speed 1500 rpm Efficiency 97% The power plant consists of the geothermal combined cycle unit, the brine driven OEC unit plus following main systems: Power plant geothermal fluid gathering system Auxiliary systems Electrical systems Main station control Fire fighting systems Auxiliary buildings Bulletin d Hydrogiologie No I7 (1999) 429

The generator circuit breaker, control and auxiliary electrical equipment for each binary unit is housed in a container, which is fully wired and protested. This reduces construction time and speeds commissioning on site. The overall station control is from a control room attached to the steam turbine building. The station control is by computer utilizing software and graphics developed by Ormat. Construction programme The modular nature of this plant has allowed a very short construction period on site. All the binary turbines were mounted on simple, low level foundations. As the steam turbine has no attached condenser it too is mounted on a low-level foundation, allowing a simple turbine building of modest size. The binary plant components were designed to be shipped in packages of standard container size and within days of the shipment arriving the main components were bolted down and the air cooled condenser erection was under way. The overall program for the plant development was as follows: Decision to proceed July 1995 Contract award December 1995 Notice to proceed March 1996 Delivery of main equipment April 1997 Commercial operation November 1997 Environmental impact The station was designed to have virtually no environmental impact. Under normal operating conditions the geothermal fluid is completely contained fiom production to reinjection with the only emissions being negligible quantities of steam emitted by the steam traps, and the non-condensable gases emitted above the air coolers. The plant has a small footprint, and an extreme low profile when compared with a conventional condensing steam turbine with underslung condenser. The air cooler structures are also of much lower profile than wet cooling towers, and have the advantage of never producing a visible plume. In addition to its low profile, the plant has no water or chemicals consumption and no blowdown of contaminated cooling tower water. All used fluids are re-injected into dedicated reinjection wells drilled for this purpose. The power generation technology implemented at Rotokawa complies with the resource consents and is dedicated to the needs of a sustainable, environmentally benign and reliable geothermal power plant. This development was carefully planed to avoid any adverse effect on the resource. The potential of this field was estimated to be between 100 and 200MW so that this development started with just a 24 MW station to unable monitoring of the field before any further development will be carried out. We at Ormat believe that the greatest achievement of this project is not the speed of its development, nor even its innovative technology. The 430 Bulletin d'tiydrogiologie No I7 (1999)

LEGMANN: ROTOKAWA GEOTHERMAL COMBMEO-CYCLE POWER PLANT h e significance of this project is that it is New Zealand s first power project to involve local Maori landowners as a full partner. And as such, it serves as a model for the development of the country s natural resources. Because the development is small relative to the ultimate capacity of the very deep resource, it is expected that there will be no impact on the surface features. A comprehensive baseline monitoring program was undertaken prior to project operation and an ongoing program is monitoring any changes against this baseline. Operation and maintenance During the frst year of operation of the station, the operation was contracted to Power New Zealand Contracting who supplied six operators to provide 24 hour cover on a 12-hour shift basis. Two operators were on duty during the day shift and a single operator at night. Operators were required to undertake in addition to the operations duties, minor routine and emergency maintenance work as well. The station is supervised by an operations manager. All maintenance work was contracted in fiom selected contractors available in the area. Apart fiom the operators, some of whom are qualified trades people, there is no permanent maintenance staff. The analysis of the costs of the first operational year shows that a significantly reduced operating costs has been achieved without having any negative impact on the generated MWh. Operating at an average output of approximately 25.5 MW and at a yearly availability of over 96%, the plant has achieved an unexpectedly high annual output of over 215 GWh, at an operating cost of under 0.3 US $/kwh. Summary We believe that this project is a model of best practice in this geothermal field. In engineering terms, Ormat have erected a sophisticated power station, featuring the latest in geothermal technology. In fact, this is only the third power station of this configuration anywhere in the world. A similar power plant with a generation capacity of 60 MW is presently erected at Mokai, New Zealand. Bulletin d Hydrogdologie No I7 (1999) 431