Installation Instructions

Similar documents
FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

Skimmers. The Industry Standard for Performance and Reliability. For All Types of Inground and Aboveground Swimming Pools

1 PVC or ABS drain with strainer

Multi-Piece Shower with Trench Drain

Installation instructions. LORO-ATTIKASTAR siphonic drains

Multi-Piece Shower with Trench Drain

Multi-Piece Shower with Trench Drain

BioPrism Solid Surface

Assembly Instruction wedi Fundo Floor element

assembly and installation guide

Liner Replacement Instructions:

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2

CI/SfB (52.5) X June 2008 CH301. Domestic Channel Drainage Systems. Product Guide

Wellmaster Installation Manual Edition 4

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

FIREPRO FIRESTOP PIPE COLLARS. Firestop solution for plastic pipework penetrations

CYPRUS STONEX SHOWER FLOORS

200 Series In-Slab Pool Fittings

adjustable fusion shower pan surface mounted on subfloor installation guide

LK Wallbox UNI Push X16 V2

adjustable fusion shower pan on wood joists installation guide

The professionals choice. Installation instructions Torridon. shower tray

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

INSTALLATION AND OPERATING INSTRUCTIONS

YOUR SPLASH PAD RESOURCE

CI/SfB (52.5) January 2004 Uniclass L L2123. ACO LightShaft Daylight and fresh air. Naturally.

Terrain HDPE. Product Guide

Signature Series MicroFalls Filter

Installation Manual For Conical Tanks. INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS

FLOOR AND AREA DRAINS

BioPrism Solid Surface

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

Shower Tray - Timber Floors

Rough-in frame and flush-mount panel installation instructions

fusion shower pan on wood joists installation guide

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

B-500 / B-600 SERIES

MODEL INSTALLATION INSTRUCTIONS

Assembly Instruction. wedi Fundo Primo Shower System

INSTALLATION INSTRUCTION (U.S.A) FOR LUMI-O DRY NICHE INGROUND LIGHT.

Thermatile Ten-Twelve Radiant Panels. Installation instructions

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Low-Profile Multi-Piece Shower with blue, high-density polyurethane bottom

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

GB-20. Submittal Specifications Installation Application Specific Details

(52.9) Rev 1.0 November 2009 John Newton & Co. Ltd. NEWTON SYSTEM 500 TITAN-PRO WHITE - PUMPING SYSTEM FOR NEWTON SYSTEM 500 INSTALLATION MANUAL

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

DEEP SOAK PRODUCT REQUIREMENTS. A. Product Requirements. B. Product Inspection. C. Clearance Requirements T01-A

INSTALLATION INSTRUCTIONS

Maelstrom. Installation and Specification Guide

STAINLESS STEEL DRAINAGE PRODUCTS

Easy Drain. INSTALLATION MANUAL Xs - Linear shower drain FOR WOODEN OR CONCRETE SUBFLOORS

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS

BRITESTREAM LED NICHE LIGHT

DeltaTrayTamar PCS. Installation Guide for Centre and Offset Drain. INSTALLING DELTATRAY tamar A PCS GUIDE TO CREATING THE PERFECT WETROOM

Valance Installation. For Units with Beam Style Coils

Model No. BWTDWFK-TRIFLO.

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Infinity - Century Combination Installation Instructions Gelcoat & Solid Surface Bathware

Installation Instructions DEKO PV 1090

N Scale Double Track Lift Bridge v1.2

Installation Manual. Read the complete installation manual and Owners Manual before beginning the installation.

Floor drain armatures

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

Installation Instructions

INSTRUCTION MANUAL.

Installation Instruction for Plastic Floor Drains and Accessories

II TECHNICAL INSTALLATION GUIDE

ACO Building Drainage

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

Fiberglass Dispenser Sump

San Antonio Water System Standard Specifications for Construction ITEM NO. 852 SANITARY SEWER MANHOLES

MODEL INSTALLATION INSTRUCTIONS

MEGA-COOL. Evaporative Cooling Systems. Hired-Hand MFG., INC. PO Box 99 Bremen, Alabama Manual Part No Rev 1-08

Multi-Gard PVC Assembly/ Field Cuts

Aluminium Roof Outlets - Application Details

INSTALLATION INSTRUCTIONS B-407-RB SERIES SINGLEWALL RETROFIT TANK SUMP

RapidBrace Installation Guide

Shower Pan Extension Installation Guide

Important Information

t y p e V S A S E W A G E P U M P

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION

LK Manifold Cabinet UNI, LK Prefab Cabinet UNI

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

Multi-Piece EasyStep Product Installation Instructions

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

Wabo ElastoFlex - EFJ/EFJ-C Horizontal Expansion Joint System

Solid Floor Systems. Underfloor heating for solid or screeded floors. Clip rail and staple system. Red Floor Panel

Transcription:

Installation Instructions (for part no:s HD100SN, HD100N, HD100LAK, HD1001SCS, HD1001CS, HD1001SLS, HD1001LS, HD101LS) s

- Pool Installation (Part Nos: HD100SN Collar Weir or HD100N Flap Weir & HD100LAK) 293 Pool coping 150 Static water level skimmer body pool adaptor Gasket 1.5 pump suction Clamping Wall panel Front Spare port plugged with metric slip plug (HD8M) 1 Wall Panel Aperture 30 94 55 256 9 137 137 175 7 No 6mmØ holes in wall panel Things To Remember Ensure that skimmer is set square and level Debris and concrete should be prevented from entering skimmer unit during construction adaptor should be used as a tem for 7 No holds after aperture has been cut out should be trimmed out as tightly to inside edge of skimmer throat as possible Any threaded connections should be made with PTFE tape, not liquid jointing To set your skimmer further back from the pool edge, Parallel extension throats are available All pipework and pool fittings must be pressure tested before backfilling

Panel wall 2-part adaptor Screw 1 Pass skimmer throat through panel wall aperture (see previous page for details) and clip 2-part liner adaptor onto recess on skimmer throat. Push skimmer back through wall until liner adaptor touches panel wall and all seven holes are aligned. Slot clamp under skimmer throat and bring up to the wall forming a sandwich, ie liner adaptor - panel wall - clamp. Using screws provided, secure all parts together. NB, It is important that screws are tightened equally and are not over-tightened. Clamp 2 Apply gasket to liner adaptor. After liner is in place, feel through liner for holes in gasket / liner adaptor and offer front finishing to skimmer throat ensuring all 16 holes are aligned. Using screws provided, secure front finishing to skimmer through pool liner and gasket. Important Do not use screws until water level has reached skimmer throat. Finish with white plastic caps. Panel wall 2-part liner adaptor Screw with white plastic cap Front finishing 2

With Wide Angle Extension Throat - Panel Pool Installation. (Part Nos: HD100SN Collar Weir or HD100N Flap Weir & HD101LS Wide Angle Throat) Top of panel wall 10mm 196mm 423mm 6 No 5mm Ø holes in panel wall 227mm 9mm 125mm 1 Details of panel wall aperture Cut aperture in panel wall as per diagram. The front face of the wide angle throat can be used as a tem for the 6 No 5mm holes (for holding screws) after the aperture has been cut out.. 191mm Water Level 173mm 403mm Nut (SPC429) 2 Pass wide angle extension throat into panel wall aperture from pool side and line up 6 holes in throat face with the 6 holes in the panel wall. NB, ensure throat is the correct way up - top is indicated on the throat. Attach the throat firmly to the panel using the 6 holding screws and nuts provided. Panel wall Wide angle extension throat 3 Holding screw (SPC428)

Back of panel wall lip recess front lip Extension throat recess 3 Using a brush, apply ABS cement to the front lip and recess of the Certikin skimmer and to the recess in the back face of the extension throat. Slot the skimmer lip down into the slot in the throat until firm. (The two holes in the base of the throat recess allow excess cement to squeeze out, ensuring an all-round fit). Using the brush, smooth off any other excess cement and re-coat the joins of the skimmer-throat inside and out, filling any voids to ensure a watertight seal. 4 Apply gasket to front face of extension throat. Important Do not fit liner clamp flange until water level has reached the level of the throat. After liner is in place, feel through liner for holes in gasket / throat face and offer clamp flange to throat ensuring all 16 holes are aligned. Using self-tapping screws provided, secure clamp flange to throat through pool liner and gasket. Carefully cut liner material from centre of throat aperture. Finish using clip-on cover. 2nd Gasket 1st Gasket (SPC435S) Panel Wall Clamp flange (SPC434S) Clip-on cover (SPC432) Self-tapping screw (SPC405N) 4

With Wide Angle Extension Throat - Concrete Pool Installation (Part Nos: HD1001SCS Collar Weir or HD1001CS Flap Weir) Surface skimmer weir lid Pool coping Flat finishing bezel (SPC436) to be glued to wide angle throat Floating skimmer weir Form re-inforcing cage around skimmer Front face of wide angled throat to be set flush with pool finish Slotted wide angle extension throat to be fixed to skimmer with solvent cement 1.5 BSP suction pipe Puddle flange Metric port plugged with slip plug (HD8M) from outside Strainer basket Flap weir (SPC423) available as alternative to floating collar weir Pool finish av thickness 25mm Things To Remember Ensure that skimmer is set square and level. Slurry and concrete must be prevented from entering skimmer during construction. Use PTFE tape to make threaded joints. Liquid cement must not be used on threaded joints. Suction pipe lid (remove film after installation) 300 210 353 All pipework and pool fittings must be pressure tested before backfilling. Concrete around skimmer body Flat finishing bezel Wide angle throat 5

With Wide Angle Extension Throat - Concrete Block-Walled Pool Installation. (Part Nos: HD1001SLS Collar Weir or HD1001LS Flap Weir) Cover Clamp flange Gasket Rendering Block wall Clamp flange Clip-on cover Gasket Block wall Apply gasket to front face of extension throat. Important Do not fit liner clamp flange until water level has reached the level of the throat. After liner is in place, feel through liner for holes in gasket / throat face and offer clamp flange to throat ensuring all 16 holes are aligned. Using self-tapping screws provided, secure clamp flange to throat through pool liner and gasket. Carefully cut liner material from centre of throat aperture. Finish using clip-on cover. Self-trapping screw (SPC405N 6

- Concrete Pool Installation (Part Nos: HD100SN Collar Weir or HD100N Flap Weir) lid Surface Body Floating Weir Strainer Basket Form Reinforcing cage Around 293mm Pool Coping Static Water Level Flap weir (SPC423) available as alternative to floating collar weir. Pool finish av thickness 25mm 1.5 BSP Suction Pipe Puddle Flange Metric port plugged with slip plug (HD8M) from outside. Not To Scale Things To Remember All pipework and pool fittings must be pressure tested before backfilling Spare port plugged from inside with 1.5 BSP plug. Use PTFE tape to make threaded joints. Liquid cement must not be used on threaded joints Ensure that skimmer is set square level slurry and concrete must be prevented from entering skimmer during construction 7

Certikin International, Witan Park, Avenue 2, Station Lane Industrial Estate, Witney, Oxfordshire OX8 6FH United Kingdom UK Tel: 01993 778855 UK Fax: 01993 778620 Export Tel: +44 (0) 1993 700744 Export Fax: +44 (0) 1993 708499 27.03.02