Low temperature sterilization with hydrogen peroxide vapour; V-PRO TM applications & best practice

Similar documents
Technical Data Monograph. V-PRO max Low Temperature Sterilization System

Technical Data Monograph. V-PRO max 2 Low Temperature Sterilization System

Low Temperature Sterilization

International Technical Data Monograph. V-PRO max Low Temperature Sterilization System

NEW Faster, more versatile!

NEW Faster, more versatile!

Technical Data Monograph. STERIS VHP LTS-V - Low Temperature Surfaces Terminal Sterilization

8/27/2015. Learning Objectives. Purpose of Sterilization. To destroy all living pathogenic microorganisms

Nitrogen Dioxide (NO 2 ) PDA: A Global. Sterilization and. Association. Decontamination Systems. November 4, PDA Europe Parenterals 2014

DRIVING INNOVATION. DELIVERING THROUGHPUT.

VHP Sterilization and Prion Inactivation

What is happening inside that magic box? Fundamentals of vaporized hydrogen peroxide sterilization in health care facilities

THE BASICS OF STERILIZATION

MDRAO ONLINE COURSE FOURTH EDITION 2018

Cool when it counts. 3M Steri-Vac Sterilizer/Aerator GS Series. For Health Care Facilities

Global Sterilization Equipment Market: Trends & Opportunities ( )

Competency Guide: Care and Handling of Rigid Endoscopes

Objectives. The Perioperative Nurse s Role 6/24/2016. Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016

Sterilization & Chemical Resistance of Healthcare Polymers

TEST CODE DEFINITION STERRAD H202. Test Code Test Name Testing Description. Cycle. Efficacy. SE-200 STERRAD 200 Efficacy. Cycle. STD Cycle Efficacy

Minimizing Ethylene Oxide and Glutaraldehyde Use Marcy Yeshnow ski Tetra Tech EM Inc.

The inaugural use of vaporized

HANDLING OF WRIGHT DISPOSABLE PROPHECY ANKLE INSTRUMENTS

Packaging & Sterilization

The Evolution of Liquid Chemical Sterilization. For High-Speed Device Turnaround

Master the elements. Unleash your potential.

8,000 facilities count on it

VHP M100 Biodecontamination Systems: Open Loop

The inaugural use of vaporized

Advances in hydrogen peroxide gas plasma sterilization

Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar

CATHETER and GUIDEWIRE-BONDING ADHESIVES

Low Temperature Hydrogen Peroxide Sterilizer

DuPont Formacel. Materials Compatibility with DuPont Formacel S BLOWING AGENT TECHNICAL INFORMATION ABA-12

They can be used on washer-disinfectors, ultrasonic cleaners, surgical instruments and endoscopes. Page 5

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

Creating the Improved Standard in Healthcare Sterilization

The Gold Standard in Low Temperature Sterilization: Ethylene Oxide

With Vaporized Hydrogen Peroxide

November 18, Andersen Sterilizers, Inc. Dr. William Andersen President 3154 Caroline Drive Haw River, North Carolina 27258

Design of Rigid Plastic Packaging for Recycling

Disinfection and sterilisation

gke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes

HIGH-LEVEL DISINFECTANT AND STERILANT

3.03 Understand support services

Understanding ANSI/AAMI ST 91. Flexible and Semi-Rigid Endoscope Reprocessing in Healthcare Facilities

Safety, Efficacy, and Microbiological Considerations. * For use with RAPICIDE PA outside of the USA, Canada and Australia

Surface Compatibility and the Use of the SteraMist BIT Systems:

Surface Compatibility and the Use of the SteraMist BIT Systems:

Stericool H 2 O 2. plasma sterilizers Affordable low temperature solution

Quality Control EQUIPMENT CONTROL. Monitor critical performance characteristics of sterilization, decontamination or cleaning equipment

We ve built a STRONG CASE. for changing the way you sterilize. Reusable Sterilization Container System

Endoscopy and OR Solutions SYSTEM 1 TM. Express STERILE PROCESSING SYSTEM SAFETY, ASSURANCE AND EFFICIENCY. One Integrated Approach to Healthcare

Sterilization and Disinfection: Getting It Right. Instructions

3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17

Plastic Assembly Technologies, Inc Castlewood Drive, Suite B, Indianapolis, IN 46250

Putting Confidence in Your Hands.

Practical Guidance in Selecting Materials for Product Functionality

Low temperature sterilizer Getinge STERIZONE VP4

ENDOSCOPY PRACTICE Manual cleaning and Disinfection of flexible endoscopes

3/11/ M Sterile U Network 3M Sterile U Web Meeting March 11, Welcome! Topic: An Overview of ANSI/AAMI ST58: 2013

PROPERTIES, REQUIREMENTS,

Medline Gemini Sterilization Wrap. Test Studies

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of

AS/NZS 4187 RELEVANT STANDARDS. Robyn Williams NUM CSSD LBHHS & Standards Australia Chair HE-023

Visualizing Material Properties in the Classroom

HANDLING OF WRIGHT MEDICAL DISPOSABLE PROPHECY TM ANKLE INSTRUMENTS

6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of

Ideal Sterilization Method. Sterilization. Sterilization Practices in Healthcare Facilities

Aesculap SterilContainer System Instructions for Use Steam, Ethylene Oxide and Vapor Hydrogen Peroxide Sterilization Modalities

Electrical Conductivity of Selected Materials

BEST PARTER & BEST SOLUTION RENO Plasma Sterilizer

HemoCheck TM Sample Policy. SUBJECT: Detection of blood residue on various surfaces

4 MATRIX MATERIALS 4-1

HemoCheck TM Sample Policy. SUBJECT: Detection of blood residue on various surfaces

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

Synthetic Petroleum-Based Polymers

Raven Labs. Sterility Assurance for Industry. Sterility Assurance Products Since A division of Mesa Laboratories, Inc.

Quality Assurance with Rigid Containers Katrina Simpson, M.A., CST, CSPDT

In view of this, packaging of food products has attained top priority, which has increased both in quantum as well as in variety.

Engineered Polymers (Semi-crystalline)

3.03 Understand support services

HyperGrip Series Product Sterilization White Paper

Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

Vaporized Peracetic Acid (VPA) Verified Effective for Sterilizing Bioabsorbable Medical Devices

3/26/2014 SPAULDING CLASSIFICATION OBJECTIVES PRINCIPLES OF DISINFECTION AND STERILIZATION IN THE DENTAL SETTING PROCESSING SEMI CRITICAL OBJECTS

PRINCIPLES OF DISINFECTION AND STERILIZATION IN THE DENTAL SETTING OBJECTIVES

Packaging Systems for Central Service Operations

Military Specifications

Sterile Services and Theatres Working in Harmony

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

SMART Wind Consortium Subgroup Virtual Meeting:

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

Quality Control LOAD CONTROL. VERIFY Load Control Products. Use to monitor and release instrumentation with confidence RECORD KEEPING & LABELING

2/19/2009. Plastics History. Plastics type INTRODUCTION. Thermosets RM1565 MOULD DESIGN. Generalproperties: more durable, harder, tough, light.

How is Sterilization Validation Performed by the Medical Device Manufacturer?

Urgent - Field Safety Notice

Transcription:

1

Low temperature sterilization with hydrogen peroxide vapour; V-PRO TM applications & best practice Dr. Georgia Alevizopoulou MD Senior Manager, Clinical Education STERIS Infection Prevention Technologies 2018 STERIS Corporation

What is low temperature sterilization? By low temperature, we typically mean below steam sterilization temperatures and typically below 80 C; in practice this is chemical Why low temperature sterilization? Historically, needed to be able to sterilize heat sensitive devices Today, explosion in MIS surgery and endoscopy: Demand to expand utilization of low temp inventory through rapid processing Restrictive regulatory climate for EO Gas Desire for process that requires minimal safety precautions Change in guidelines and standards

Evolution of Low Temperature Sterilizers Ethylene oxide (EO) Low-temperature steam-formaldehyde (LTSF) Liquid chemical sterilization Vapor Hydrogen Peroxide With plasma Without plasma Hydrogen peroxide/ozone

Hydrogen Peroxide H 2 O 2 Clear liquid, water-like, odorless Powerful antimicrobial especially in the gaseous phase Practical use: 0.1-60% in water Greater efficacy as concentration increases Balance with material compatibility Environmentally safe: Decomposes to form water and oxygen STERIS Corporation 2018

V-PRO TM Low Temperature Sterilization Systems

Intended Use Rapid, low temperature terminal sterilization of properly cleaned, rinsed and dried reusable metal and non-metal medical devices used in healthcare facilities. The sterilization cycles operate at low pressure and temperature, suitable for processing medical devices sensitive to heat and moisture. Utilize STERIS VHP technology 7 Technical Data Monograph V-PRO max, Low Temperature Sterilization System STERIS Corporation 2018

The VHP principle of operation Hydrogen Peroxide (Liquid) H Hydrogen Peroxide (Gas) O O H O + H 59% Vaporization H Catalytic converter O O Non-Toxic Residues 9 STERIS Corporation 2018

The Plasma sterilization process 59% Energy Electromagnetic field Positive Ions (O +, O 2+, O +2 ) Electrons (e - ) Negative Ions (O -, O 2- ) Other Reactive Species (O 3, Free radicals) Liquid Gas Plasma

STERIS Corporation 2018

Example Cycle Description (V-PRO 1, 1 Plus, and max Non Lumen Cycle) Condition Sterilize Aeration 1000.0 Pulse 1 Pulse 2 Pulse 3 Pulse 4 5 1/2 Cycle 100.0 1 Pressure (Torr) 10.0 3 4 1.0 2 6 7 0.1 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Time (min) 1. Evacuate chamber 2. Moisture check 3. Prepare for injection, Inject 4. Post injection hold 5. Transition to 500 Torr, hold 6. Evacuate, prepare for next pulse 7. Evacuate chamber to Aerate

The V-PRO family- Continuous innovation Cycle (Minutes) V-PRO 1 V-PRO 1 Plus V-PRO max V-PRO 60 Lumen 55 55 55 60 Non Lumen --- 28 28 28 Flexible --- --- 35 38 VAPROX HC Sterilant 59% hydrogen peroxide solution used in all V-PRO Sterilizers STERIS Corporation 2018

Q: What are the key factors in choosing your low temperature sterilization process?

Safe profile 16 STERIS Corporation 2017

V-PRO Low Temperature Sterilization Delivering Safety Embed safety video 17 STERIS Corporation 2017

Prion inactivation* *V-PRO Sterilizer, Technical File, Section 7 STERIS Corporation 2018

Material Compatibility* Extensive testing has shown VAPROX HC Sterilant to be compatible with materials commonly found in surgical, endoscopic and other devices Typical examples include: Aluminum Delrin acetyl resin (polyacetal) Ethylvinyl acetate (EVA) N Glass KRATON Polymers Neoprene Noryl (Polyphenylene oxide) Non-mated Nylon (polyamide) Polymethyl methacrylate (PMMA) Polycarbonate ULTEM Polymers (Polyetherimide) Polyethylene Polypropylene Polystyrene Polyurethane Polyvinyl chloride (PVC) Radel (Polyphenylene sulfone) Silicone Stainless Steel Teflon (Polytetrafluoroethylene) Titanium 19 * International Technical Data Monograph STERIS Corporation 2018

22

A device is suitable for V-PRO when: Device: Is moisture/heat intolerant Requires sterilization User: Requires fast turnaround Sterile storage is required Transport off site Value for money: Improve instrument quality/shelf life Reduce repair/replacement costs 23 STERIS Corporation 2018

Q: Which reusable instruments are used which cannot be sterilized in an autoclave?

Change in the guidance Sterile scopes The choledochoscope The intubation scope The urology scopes NEW STERIS Corporation 2018

Example: The intubation endoscope How long is it on the airway trolley for? Do you always have the time to reprocess before used on a patient? Best Practice Wouldn t it rather be sterile and wrapped?

Flexible Cycle Process single channel surgical flexible endoscopes, such as urethroscopes, bronchoscopes and those used in ENT Process dual channel surgical flexible endoscopes STERIS Corporation 2017

Establish compatibility The evaluation may occur either at the time of sales negotiation, or at the time of acquiring the sterilizer, or when new medical devices are purchased, or when medical devices are loaned to the healthcare facility. Key considerations: Material compatibility Lumen compatibility Maximum processing load STERIS Corporation 2018

Using the STERIS Device Matrix STERIS Corporation 2018

STERIS Corporation 2018

STERIS Corporation 2017 Terminal Sterilization

Preparation of Devices Properly cleaned, rinsed and dried Instruments can be assembled into sets or single, wrapped or placed in wrapped trays, pouches or rigid sterilization containers STERIS Corporation 2017

Require specific packaging material

Routine Monitoring - SAP Chemical Indicators Biological Indicators

VH2O2 Low Temp Sterilization is evolving http://aboutmanchester.co.uk/the-future-of-jobs-lies-in-the-creative-sector/ STERIS Corporation 2018

Get on SU online portal http://university.steris.com STERIS Corporation 2018

Continuing to transform the standard of Low Temperature Sterilization STERIS has over 30 years of experience with vaporized hydrogen peroxide and has been the innovator in low temperature sterilization modalities 10+ million procedures across the globe are performed with devices that have been reprocessed with V-PRO sterilizers using vaporized hydrogen peroxide 59 STERIS Corporation 2018

Efharisto!

Get connected to STERIS University and its team of Expert Industry Professionals university.steris.com educationdesk@steris.com STERIS Corporation 2017