SEWER MANHOLE REHABILITATION - STRUCTURAL COMPOSITE LINING (as provided by AP/M Permaform)

Similar documents
SEWER MANHOLE/WET WELL REHABILITATION, SEVERE SULFIDE (as provided by WBE Dorcas, Inc.)

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

TECHNICAL REQUIREMENTS AND SPECIFICATIONS. PROTECTIVE COATING OF STEEL (As Provided by Raven Lining Systems) FOREWORD

TECHNICAL SPECIFICATION FOR CURED-IN-PLACE MANHOLE REHABILITATION LINER SYSTEM

profile-mix-plus, Page 1 of 8, Rev

SECTION CORROSION PROTECTION FOR CONCRETE STRUCTURES

Process Specification. Structural Rehabilitation & Corrosion Protection for Circular Structures in Wastewater Collection and Potable Water Systems

MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES

Special Specification SS1- INTERNAL CIPP POINT REPAIR OF PIPELINES. A. General. 1. Scope

CITY OF TAMPA ADDENDUM NO. 3. DATE: February 15, 2017

Strong-Seal Sealant Specification, a permanent method of sealing the interior of the chimney and casting in manholes and catch basins.

STRUCTURAL CEMENTITIOUS LINER PERMACAST BY AP/M PERMAFORM

CITY OF TAMPA ADDENDUM NO. 1. DATE: September 15, Contract 11-C-00001; Wastewater Sewer Rehabilitation by Cured-in-Place Pipe (C.I.P.P.

BENCH MIX SPECIFICATIONS for REPAIR OF BENCHES IN MANHOLES WITH INERT LINES

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

Florock Seamless Flooring Systems

HIGH PERFORMANCE MIX SPECIFICATIONS

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

FIVE STAR PRODUCTS, INC. (800)

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

1/16 Single Broadcast Polymer Flooring System

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

Section Pedestrian Traffic Coatings

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

INSTALLATION GUIDE SPECIFICATION

B. The condition of the structures to receive the protective coating will be classified in accordance with the following criteria:

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DIVISION 9 - FINISHES Section Coatings

DIVISION 3 - CONCRETE Section Concrete Toppings Concrete Resurfacing Concrete Rehabilitation

SECTION POLYURETHANE MIC COATINGS. A. Furnish and install special coating systems in accordance with the Contract Documents.

FOREWORD PART 1 - GENERAL. A. Requirements for surface preparation, repairs and 100% Solids epoxy coating application to specified surfaces.

Florock Seamless Flooring Systems

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Florock Seamless Flooring Systems

FOREWORD PART 1 - GENERAL

Division 3 - Concrete Section Concrete Rehabilitation

Zinc Silicate (Inorganic)

Instruction Guide APPLICATION OF CIM TO CONCRETE

SECTION A. American Society for Testing and Materials (ASTM):

TECHNICAL INFORMATION. 331 and PENNCOAT 340 LINING INSTALLATION. CES /01 Supersedes 04/00 PAGE 1 of 7 1. SURFACE PREPARATION. 1.

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

Elastocoat Protective Coatings APPLICATION GUIDE

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

Application Guidelines

Pol-E-Base Modified Bitumen Roof System

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

SECTION RESINOUS FLOORING

FLEXIBILIZED TROWEL APPLIED, GLASS

VALLECITOS WATER DISTRICT SECTION PRECAST REINFORCED CONCRETE MANHOLES

CONDENSED DESIGN GUIDE. for TRENCHLESS MANHOLE RENEWAL with PERMACAST / PERMAFORM TECHNOLOGY

PERFORMANCE, 100% SOLIDS,

RESINOUS FLOORING

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS

SAN ANTONIO WATER SYSTEM 2013 REHABILITATION WORK ORDER CONSTRUCTION CONTRACT 4 SAWS Job No SAWS Solicitation No.

STANDARD SPECIFICATIONS FOR CONSTRUCTING SANITARY SEWER FACILITIES DIVISION III - CONSTRUCTION SPECIFICATIONS SECTION 4

The Importance of Proper Inspection. Rocky Capehart

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

SECTION A. American Society for Testing and Materials (ASTM):

SECTION A. American Society for Testing and Materials (ASTM):

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DIVISION 9 FINISHES Section Floor Finishes

729 - MULTI-LAYER POLYMER CONCRETE OVERLAY SECTION 729 MULTI-LAYER POLYMER CONCRETE OVERLAY

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

KOSTER AMERICAN CORPORATION

Florock Seamless Flooring Systems

1.00 PART 1 -- GENERAL

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

SECTION EPOXY TERRAZZO

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

BAYBLOCK HT/BAYBLOCK HT BASE

Infrastructure Point Repair System Technical Specifications

Part 1 - General. Spec Component Sikadur 32 Hi-Mod. DIVISION 3 -CONCRETE Section Cast-in-Place Concrete Bonding Agents for Concrete

CIM IG 13 11/06. Instruction Guide

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Prepared By: Engineering Staff Approved By: Jerome T. Schmitz

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Tunnel Painting

SUGGESTED MANHOLE FRAME SEALING SPECIFICATION (Rehabilitation)

Polymer Linings for Restoration & Corrosion Protection of Steel Surfaces: Crude Oil Storage Tank Repair and Reline in New Zealand

Solventless two-component crosslinked epoxy

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Pacific Polymers Elasto-Deck 5000MR Guide Specification

STERI-FLEX SPECIFICATIONS FEATURES

Bridge Preservation Product Advantages:

Multi-Institutional Academic Health Science & Research Center Evansville, IN

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

Transcription:

SEWER MANHOLE REHABILITATION - STRUCTURAL COMPOSITE LINING (as provided by AP/M Permaform) 1 Intent:...2 2 Applicability:...2 3 Referenced Standards...2 4 Related Sections...2 5 Structural Composite Lining...2 6 Submittals...6 7 Product Handling...6 8 Quality Assurance and Acceptance...7 9 Measurement for Payment:...7 REV 6/07 Page 1 of 7

SEWER MANHOLE REHABILITATION - STRUCTURAL COMPOSITE LINING PERMACAST and COR+GARD BY AP/M PERMAFORM 1 Intent: It is the intent of this specification to provide minimum standards for materials and methods for waterproofing, sealing, structural reinforcement and corrosion protection of existing manholes, wet wells and similar underground structures from the cover to the channel. This specification offers flexibility in design by offering technologies available for repairing the various defects found in sanitary sewer structures from minor leaks to complete structural failure. 2 Applicability: These repair means and methods may be engineered for the depth, diameter, shape, traffic loading, groundwater pressures and condition of each manhole. 3 Referenced Standards 3.1 ASTM D-695 Standard Test Method for Compressive Properties of Rigid Plastics 3.2 ASTM D-790 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials 3.3 ASTM D-638 Standard Test Method for Tensile Properties of Plastics 3.4 ASTM C-882 Standard Test Method for Bond Strength of Epoxy Systems Used with Concrete by Slant Shear 3.5 ASTM D-4541 Pull-off Strength of Coatings Using a Portable Adhesion Tester 3.6 ASTM D-4414 Standard Practice for Measurement of Wet Film Thickness of Organic Coatings by Notched Gages 3.7 NACE RP0274 High Voltage Electrical Inspection of Pipeline Coating Prior to Installation 3.8 ASTM F2304-03 Standard Practice for Rehabilitation of Sewers Using Chemical 3.9 NACE 6/ SSPC-SP 13 Surface Preparation of Concrete Grouting. 4 Related Sections 4.1 Structural Cementitious Lining 4.2 Manufactured Frame-Chimney Insert I & I Barrier 4.3 Applied Frame Chimney Internal Seal 5 Structural Composite Lining 5.1 See section on Structural Cementitious Lining 5.2 Once the cementitious base layer has been applied to seal, reinforce and smooth the existing interior surface, the COR+GARD epoxy is applied at a minimum thickness of.065 (1.65 mm) to provide a complete and uniform vapor barrier against attack by sewer gases and corrosion causing bacteria. The surface shall be free of entrapped air bubbles or holidays. 5.3 COR+GARD is a two-component 100% solids epoxy design formulated for use in sewer systems. It is light green in color for enhanced visibility and may be applied robotically from the PERMACAST patented robotic applicator for uniform distribution over the entire interior surface without requiring entry and its corresponding safely requirements. Centrifugal casting avoids air bubble entrapment. COR+GARD will cure quickly, even when immersed in fresh or salt water and rapidly forms a tenacious bond to freshly applied PERMACAST mortars which are formulated to prevent delaminating calcium powders from forming during hydration. COR+GARD composite produces a smooth, REV 6/07 Page 2 of 7

glossy and homogenous protective layer that is impervious to biological corrosion, water, oils and most chemicals. 5.4 COR+GARD II is a two-component 100% solids epoxy especially formulated for use in sewer systems where increased flexibility is required. It is light green in color for enhanced visibility. It will cure quickly, even when immersed in fresh or salt waters. It quickly forms a tenacious bond to freshly applied mortars. Cor+Gard II application produces a smooth, glossy and homogenous protective layer that is impervious to water, oils and most chemicals. 5.5 COR+GARD 301 is a two-component 100% solids epoxy especially formulated for use in sewer systems where increased tensile strength is required. It is light green in color for enhanced visibility. It will cure quickly, even when immersed in fresh or salt waters. It quickly forms a tenacious bond to freshly applied mortars. COR+GARD 301 application produces a smooth, glossy and homogenous protective layer that is impervious to water, oils and most chemicals. 5.6 COR+GARD 501 is a two-component 100% solids Novolac epoxy especially formulated for use in chemically aggressive sewer systems. It is gray in color and may be applied robotically from the PERMACAST patented robotic applicator for uniform distribution over the entire interior surface of manholes, pipe, and similar structures without requiring entry. It quickly forms a tenacious bond to freshly applied PERMACAST mortars, which are engineered to prevent delaminating powders from forming during hydration. COR+GARD 501 application produces a high-build coating for continuous immersion in aggressive environments where high chemical resistance is required. COR+GARD 501 has excellent resistance to concentrated sulfuric acid, as well as alkalis and most 5.7 Physical Properties Dry Time Compressive Strength ASTM D-695 Flexural Strength ASTM D-790 Tensile Strength ASTM D-638 Hardness ASTM D-2240 Heat Distortion ASTM D-648 Ultimate Elongation ASTM D-638 Adhesive Shear ASTM C-882 The cured epoxy shall have the following HMIS Rating. Health: 0 Fire: 1 Reactivity: 0 5.8 Structural Composite Installation 5.8.1 COR+GARD 100% solids epoxy shall be applied over the fresh PERMACAST liner to create a vapor barrier impervious to the chemical corrosion. 5.8.2 Moisture Content and Mortar Age Considerations 5.8.2.1 COR+GARD may be applied when the MS-10,000 mortar has taken a final set (8-12 hrs) or when moisture from free water escape during hydration is no longer observed. 5.8.2.2 When time constraints do not allow for waiting for the final set, the surface may be conditioned to accept the COR+GARD by applying Primer. See tables 3 and 4 for application and curing schedules. REV 6/07 Page 3 of 7

5.8.2.3 Apply epoxy primer directly to the new MS-10,000 surface as soon as the surface water has disappeared. The surface may be damp but not wet. The moisture in the concrete & repair mortar is in no way harmful to the penetration or adhesion of the coating. The depth of penetration may be as much as 1/16 to 1/4. The epoxy primer acts in two ways: (1) It penetrates the mortar and acts as a primer, and (2) it forms a thin film on the mortar which is water resistant and relatively impervious, holding the water in and acting as a concrete curing compound. 5.8.2.4 Primer is top coated with COR+GARD after primer has achieved its initial set, but while in a tacky condition. If Primer has dried hard to touch before top coating, an additional coat of primer must be applied. Table 3 - Application Condition (Primer) Condition Material Surface Ambient Humidity Optimum 60-90 F 75 F 75 F 0-95% Minimum 50 F 40 F 50 F 0% Maximum 95 F 120 F 100 F 95% Surface Temp. & 50% Relative Humidity Table 4 - Curing Schedule (Primer) Dry to Topcoat Maximum Recoat Time 50 F 1.5 hours 8 hours 75 F 1 hours 5 hours 90 F.7 Hours 3 hours 5.8.3 Weather Considerations / Weather Atmosphere 5.8.3.1 Rising mortar temperatures during COR+GARD application may cause blistering and pinhole problems caused by out-gassing from the mortar. 5.8.3.2 Monitoring the dew point during periods of changing weather is recommended to ensure that COR+GARD is not applied over excess moisture that has condensed on the mortar surface. 5.8.3.3 Avoid applying COR+GARD during rain events that can saturate the newly prepared substrate with excess water. 5.8.3.4 See tables 5 and 6 below for optimum temperatures and conditions for COR+GARD application. 5.8.3.5 If rapid cure is required, cure times can be reduced and product performance enhanced by artificially applying heat during the curing process. REV 6/07 Page 4 of 7

Table 5 - COR+GARD Application Condition Condition Material Surface Ambient Humidity Optimum 60-90 F 75 F 75 F 0-95% Minimum 60 F 55 F 60 F 0% Maximum 95 F 115 F 100 F 95% Table 6 - COR+GARD Curing Schedule Surface Temperature & 50% Relative Humidity Dry to Topcoat Maximum Recoat Time Cure for Immersion Service 50 F 4 hours 24 hours 8 hours 75 F 3 Hours 18 hours 6 hours 90 F 2 Hours 12 hours 4 hours 5.8.4 Mixing 5.8.4.1 Combine equal parts of A & B Components in a clean dry pail. Do not mix by hand. Mix each pail of COR+GARD using a power mixer (e.g. ½ drill motor and Jiffy mixer paddle). Do not incorporate air into the mix. Mix thoroughly for full 3 minutes. After mixing allow mixed components to induce (sweat-in) for 20-30 minutes at temperatures below 75 F before beginning application. Care should be taken to decrease induction time as temperatures rise above 75 F to avoid flash setting. Metered plural component epoxy pumps may also be utilized to mix and dispense the epoxy through a spray gun or SpinCaster. 5.8.5 Applying the Epoxy 5.8.5.1 If application is delayed beyond 24 hours, or if the prepared mortar liner is exposed to foreign matter, it shall be rinsed to neutralize its surface and the epoxy shall then be applied. 5.8.5.2 The epoxy shall be uniformly applied onto the prepared mortar lining before re-exposure to chemicals can contaminate the underlying mortar. It is recommended that two coats of epoxy be applied to reduce pinholes. The second coat will act to repair the pinholes that develop in the first coat due to epoxy filling imperfections in the substrate. The epoxy shall be applied at a minimum thickness of.065 (65 mils) to provide a complete and uniform vapor barrier. 5.8.5.3 Optionally, fiberglass woven fabric may be rolled into the resin or chopped glass spray applied with the resin for added tensile and REV 6/07 Page 5 of 7

flexural strength where desired, such as the crown of pipes or weakened walls. The fiberglass fabric shall be cut to the required dimensions and pressed, using a putty knife, into the epoxy to achieve full wetting of the fabric. With subsequent applications of the fabric, the edges shall be either overlapped or butt-joined, at the discretion of the applicator. COR+GARD shall be applied between the overlapped edges to assure a monolithic construction. Butted joints shall be coated with COR+GARD and covered with a 4-inch wide fiberglass seaming-strip (cap-strip) to assure the monolithic construction. The fabric shall be top coated with COR+GARD. This assures complete saturation and encapsulation of the fabric, with a finished lining thickness of approximately 125-mils. The entire wall structure, from rim to bench, shall be lined in this fashion. The Reinforcing fabric shall be an 18-ounce fiberglass bonded fabric of Type E glass having a tensile strength of 500,000 psi, a modulus of elasticity of 10.5 million psi and a maximum elongation of 4.8%. The fabric shall be stitchbonded construction with a chemical binder to enhance wet out, handling and adhesion. 5.8.5.4 Sloped surfaces of the floor may be made slip resistance by broadcasting aluminum oxide or silica sand into the surface prior to gelling. 5.8.5.5 Cleanup: Upon completion, the Contractor shall clean up the work site and properly dispose any excess material or debris 6 Submittals 6.1 All submittals shall conform to the requirements of the Contract document. 6.2 In addition, the following items may be required of the installer to be submitted to the engineer at the sole discretion of the engineer. This Contract shall not be considered complete until receipt and acceptance of the following: 7 Product Handling 6.2.1 Reference submittals 6.2.1.1 Contractor certification 6.2.1.2 Material certification 6.2.2 Product data 6.2.2.1 Patching and plugging material 6.2.2.2 Cementitious lining material 6.2.2.3 Epoxy coating composite 7.1 Special handling is not required for PERMACAST mortar. Normal precautions for nuisance dust shall be observed. Consult Material Safety Data Sheet for details. 7.2 Proper protective clothing and breathing apparatus shall be used to avoid direct contact with the liquid components of COR+GARD composite if hand spraying or brushing COR+GARD is by man entry. When spraying COR+GARD with spinner head, breathing apparatus is not required. Manufacturer s material safety data sheets shall be kept on site and the applicator shall ensure familiarization with this information and emergency procedures. REV 6/07 Page 6 of 7

7.3 Personnel entry is not required to rebuild the interior wall of most manholes when using the PERMACAST spinner head. If personnel entry becomes necessary for any reason, OSHA standards for confined space entry shall be strictly observed. 8 Quality Assurance and Acceptance 8.1 Visual inspection should verify a leak-free, uniform appearance. 8.2 Applied wet film thickness shall be verified per ASTM D-4414, Standard Practice for Measurement of Wet Film Thickness of Organic Coatings by Notched Gages. 8.3 The protective coating shall be spark tested per NACE RP0274 at 100 volts per mil of dry film thickness. The dielectric strength of coatings will vary from manufacturer to manufacturer. If this value is unknown, it is recommended that a holiday be created in the coating and the tester be calibrated to the voltage that detects the flaw. 8.4 At the discretion of the engineer, a portable adhesion tester may be used to verify bond strength of the COR+GARD protective coating per ASTM D-4541, Pull-off Strength of Coatings Using a Portable Adhesion Tester. Care should be taken to conduct the test on a flat surface. Special equipment may be necessary to compensate for the walls of round sewer structures. 9 Measurement for Payment: 9.1 Payment shall be made at the unit price per vertical feet of finished wall for each prescribed thickness. REV 6/07 Page 7 of 7