APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents

Similar documents
Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

Guide Specification SECTION DUCT INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

Solutions. for the Contractor. Reflectix Insulation

GUIDE SPECIFICATION: DUCT LINER

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

Product Guide Specification

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

SECTION HVAC INSULATION

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

ESD5 GENERAL GUIDELINES ESD 5 INSTALLATION ESD 5 ROLLS HANDLING:

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS

ADC. The Greenbook of Flex. Flexible Duct Performance & Installation Standards (5 th Edition) Characteristics of flexible duct

SECTION PRE-ENGINEERED BUILDING INSULATION

PROJ. NO SECTION HVAC DUCT INSULATION

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS

WE International, Inc.

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS

SECTION PLUMBING INSULATION

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

1 of 17. PO Box Bellevue Rd, Newark, DE V F

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

FIRE STATION 55 June 14, 2010

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

Section Roof/Ceiling Thermal Insulation

SECTION MECHANICAL INSULATION

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

KwikFlex Pipe & Tank Insulation

SECTION POLYPROPYLENE FABRIC WALL COVERING

Insulation Board. Knauf Data Sheet PE-DS

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

SECTION HVAC DUCTS AND CASINGS

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

Flexible Air Duct and Flexible Air Connectors Installation and Energy Use

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology

SECTION DAMPPROOFING AND WATERPROOFING

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

Tube Insulation. Fiber Free

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

SECTION (15081) - HVAC INSULATION

Division 15 INSULATION Section 15100

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...

FlexClad Duct and Pipe Sealing System

Construction Standards PAGE

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

State of Alaska Section State Office Building HVAC Fan Replacement MECHANICAL INSULATION

Design & Construction Standards, Revised January

Master Insulation Guide Specification for Mechanical Systems

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

TempShieldTM Bubble Products...for all your insulation needs. Super R Radiant Barriers. ...for all your insulation needs

HouseWrap Applications System R-Value: R-4.17 Horizontal Heat Flow Only

SECTION HVAC DUCTS AND CASINGS

3. TEST METHOD FOR BOND PROPERTIES OF CONTINUOUS FIBER SHEETS TO CONCRETE (JSCE-E )

SECTION INSULATED METAL ROOF PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

HI-PERFORMANCE REFLECTIVE INSULATION. The most versatile insulation CONTRACTOR INFORMATION AND INSTALLATION GUIDE

INNOVATIVE TECHNOLOGY FOR THE INSTALLATION OF HEATING & COOLING SYSTEMS

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

DMS WATERPROOFING

WRAP. Housewrap is the best practice for protecting a home from wind and water while allowing it to breathe. Norandex makes it easy!

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Thermasheath-XP. Insulation for Exposed Use

PERMATHERM PIPE INSULATION PRODUCTS

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

SECTION THERMAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

Price Single Duct Terminal Units

G O G R E E N W I T H A F U L L L I N E OF ESP LOW-E INSULATION PRODUCTS

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

Insulbreak. Insulation. thermal break solution

SECTION FLUID-APPLIED WATERPROOFING

Installation Guidelines VBC Products

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

FireMaster FastWrap XL

EcoTouch Insulation with PureFiber Technology

BENJAMIN OBDYKE INCORPORATED

Extreme Sealing Tape

PITTWRAP CW PLUS JACKETING Product Datasheet

CertaPro Thermal FSK-25 Faced Batts

SECTION FIRESTOPPING

Air Handling Products

OptiLiner Banded Liner System, Thermal, Metal Building

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE

Transcription:

R-6.0 SUBMITTAL SHEET Hard Plastic Spacers D U C T I N S U L A T I O N R - 6. 0 Features AT A GLANCE: Reflectix Duct Insulation may be installed by wrapping rectangular or round ductwork in HVAC applications Heating costs can be greatly reduced Eliminate unnecessary heat loss/gain and air leakage Helps to ensure consistent temperatures WAREHOUSE LOCATIONS: Markleville, IN Phoenix, AZ Greenville, SC Needham, MA Reflectix, Inc. #1 School St. (PO Box 108) Markleville, IN 46056 (800) 879-3645 Fax: (765) 533-2327 Reflectix Duct Insulation is an alternative to other types of fibrous insulation products. Ease of handling and quick installation make Reflectix the first choice when selecting insulation for round or rectangular ductwork in HVAC systems. The product provides an R-6.0 when installed with a 0.75 air gap between the duct and the insulation. There is a choice of three spacer configurations that create the required air space. PRODUCT DESCRIPTION Reflectix Duct Insulation consists of two layers of highly reflective film (94%+ reflectivity) that are bonded to two tough layers of polyethylene. Two inner layers of insulating bubbles resist conductive heat flow while a center layer of polyethylene gives Reflectix high reliability and strength. The product has a tape running the length of the roll for easy identification by code officials. The tape identifies the manufacturer and ASTM Testing: Reflectix Duct Insulation ASTM E84 Class A / Class 1 ASTM C411 Passed APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems BENEFITS Non-toxic / non-carcinogenic Fiber-free Lowers heating and cooling costs year-round Reflects 94%+ radiant heat Costs less to install Lightweight and clean Reflectix Duct Insulation Products are ETL and Warnock Hersey Listed. Not affected by moisture / humidity Does not promote nesting of insects or rodents Resists growth of fungi, mold and mildew Does not require protective clothing or respirators to install No need for protective garments or respirators when installing ISO 9001:2008 certified manufacturing location DUCT INSULATION PART NUMBERS AND STOCK SIZES HVBP12050 (12 x 50 ) HVBP12100 (12 x 100 ) HVBP12125 (12 x 125 ) HVBP16050 (16 x 50 ) HVBP16100 (16 x 100 ) HVBP16125 (16 x 125 ) HVBP24050 (24 x 50 ) HVBP24100 (24 x 100 ) HVBP24125 (24 x 125 ) HVBP36050 (36 x 50 ) HVBP36100 (36 x 100 ) HVBP36125 (36 x 125 ) HVBP48050 (48 x 50 ) HVBP48100 (48 x 100 ) HVBP48125 (48 x 125 ) HVBP60050 (60 x 50 ) HVBP60100 (60 x 100 ) HVBP60125 (60 x 125 ) www.reflectixinc.com

TESTING & CERTIFICATIONS Thermal Performance ASTM C335 Hot Surface Performance ASTM C411 Flame Spread and Smoke Density ASTM E84 Fungus Resistance Mil-Std 810B Method 508 Pliability Test ASTM C1224 Sound Absorption Test ASTM C423 and ASTM E795 Sound Transmission Loss ASTM E90 and ASTM E413 Water Vapor Transmission ASTM E96 Tensile Strength ASTM D751 Bleeding and Delamination ASTM C1668 E84-08 (Taped Joint Detail) Test Report # 3166908SAT-012 E84-08 (Unslit) Test Report # 3166908SAT-011 R&D Services: Resistance to the Growth of Fungi ASTM C1338-00 Test Report # RD072713FR State of California State of California Licensed Insulation Manufacturer State of Minnesota: Filed with Minnesota Insulation Standards Program R&D Services Emittance Testing ASTM C1371 Double Reflective Technical Data: Temperature Range: -60 0 to 180 0 F Nominal Thickness: 5/16 inch (.312) Weight: 0.771 oz./sq. ft. Flame Spread Index (ASTM E 84): Less than 25 Smoke Developed Index (ASTM E 84): Less than 50 Mounting Method (ASTM E 2599) Fire Rating: Class A/Class 1 Linear Shrinkage: None Reflectance (IR): 94%+ Water Vapor Transmission (ASTM E 96): 0.02 Puncture Resistance: 60 lb./in. Mold and Mildew: No Growth Emittance: Less than 0.06 Tensile Strength: 3.7 N/mm Pliability: No Cracking Hot Surface Performance: Passed (250 0 F) Note: Not for use in direct contact on surface temperatures that are 180 0 F or greater. R&D Services: Physical Properties Sheet Width, Length, Pliability, Water Vapor Permanence and Aged Water Vapor Permanence R&D Services: Water Vapor Transmission Test ASTM-E96 (Dessicant Method) Hard Plastic Spacers MANUFACTURER S SUGGESTED INSTALLATION INSTRUCTIONS THERE ARE 3 OPTIONS - METHODS 1 & 2 ARE APPLICABLE TO EITHER ROUND OR RECTANGULAR DUCTS: Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. 1. SPACER PERPENDICULAR TO DUCT DIRECTION METHOD SPACER: HVSPW02025 - SPIRAL PIPE WRAP 2 x 25 Refer to the two left hand diagrams above. Double wrap and secure spacer material to the duct at 24 to 36 intervals. Use a UL 181 approved tape to fasten the spacer in place. Verify the circumference of the duct at the mid-point of a spacer strip. an air-tight, snug seam seal).

Do not leave any exposed duct or space where air can enter between the duct and the Reflectix. 2. SPACER WRAPPED IN CANDY CANE FASHION METHOD SPACER: HVSPW02025 - SPIRAL PIPE WRAP 2 x 25 Refer to the two center diagrams on page 2. Double wrap and secure spacer material to the duct in a candy cane fashion. First, proceed down the duct in one direction then reverse direction and crisscross (overlap) the spacer in the other direction. Use a UL 181 approved tape to fasten the spacer in place. Verify the circumference of the duct with the spacer strips in place. an air-tight, snug seam seal). Do not leave any exposed duct or space where air can enter between the duct and the Reflectix. 3. HV SPACERS AFFIXED TO CORNERS METHOD (RECTANGULAR DUCTS ONLY) SPACER: HVSPACER - HARD PLASTIC CORNER SPACER Refer to the two right hand diagrams on page 2. Make sure the duct is free from dust and dirt by wiping it down with a shop rag. Install the HV Spacers to all 4 corners of the duct. Place the spacers every 24. Verify the circumference of the duct over the top of the spacers. Wrap the Reflectix over the spacers. Fasten the Reflectix by either taping the seam with a UL 181 approved tape, or plier stapling the two edges together (goal is an air-tight, snug seam seal). If the duct is supported with saddle clamps, make sure to install a spacer on the two bottom edges of the duct directly between the clamp and the duct. If the clamps are installed around the duct (such as plumbers tape), make sure that the seam is taped to prevent air movement. PLEASE NOTE REGARDING HANGERS: Strap Hanger: Wrap Reflectix with the seam at the hanger. Tape seam tightly around hanger. Saddle Hanger: Make sure that there is a spacer below the hanger between the insulation and the duct to prevent the insulation from touching the duct. N20 Revised 0515

R-4.2 SUBMITTAL SHEET D U C T I N S U L A T I O N R - 4. 2 Features AT A GLANCE: Reflectix Duct Insulation may be installed by wrapping rectangular or round ductwork in HVAC applications Heating costs can be greatly reduced Eliminate unnecessary heat loss/gain and air leakage Helps to ensure consistent temperatures WAREHOUSE LOCATIONS: Markleville, IN Phoenix, AZ Greenville, SC Needham, MA Reflectix Duct Insulation is an alternative to other types of fibrous insulation products. Ease of handling and quick installation make Reflectix the first choice when selecting insulation for round or rectangular ductwork in HVAC systems. The product provides an R-4.2 when installed directly to the duct. PRODUCT DESCRIPTION Reflectix Duct Insulation consists of two layers of highly reflective film (94%+ reflectivity) that are bonded to two tough layers of polyethylene. Two inner layers of insulating bubbles resist conductive heat flow while a center layer of polyethylene gives Reflectix high reliability and strength. The product has a tape running the length of the roll for easy identification by code officials. The tape identifies the manufacturer and ASTM Testing: Reflectix Duct Insulation ASTM E84 Class A / Class 1 ASTM C411 Passed APPLICATIONS Rectangular and round return and supply ductwork in HVAC systems BENEFITS Non-toxic / non-carcinogenic Fiber-free Resists growth of fungi, mold and mildew Costs less to install Lightweight and clean Reflectix Duct Insulation Products are ETL and Warnock Hersey Listed. Not affected by moisture or humidity Does not promote nesting of birds, insects or rodents Does not require protective clothing or respirators to install Lowers heating and cooling costs year-round ISO 9001:2008 certified manufacturing location DUCT INSULATION PART NUMBERS AND STOCK SIZES HVBP12050 (12 x 50 ) HVBP12100 (12 x 100 ) HVBP12125 (12 x 125 ) HVBP16050 (16 x 50 ) HVBP16100 (16 x 100 ) HVBP16125 (16 x 125 ) HVBP24050 (24 x 50 ) HVBP24100 (24 x 100 ) HVBP24125 (24 x 125 ) HVBP36050 (36 x 50 ) HVBP36100 (36 x 100 ) HVBP36125 (36 x 125 ) HVBP48050 (48 x 50 ) HVBP48100 (48 x 100 ) HVBP48125 (48 x 125 ) HVBP60050 (60 x 50 ) HVBP60100 (60 x 100 ) HVBP60125 (60 x 125 ) Reflectix, Inc. #1 School St. (PO Box 108) Markleville, IN 46056 (800) 879-3645 Fax: (765) 533-2327 www.reflectixinc.com

TESTING & CERTIFICATIONS Thermal Performance ASTM C335 Hot Surface Performance ASTM C411 Flame Spread and Smoke Density ASTM E84 Fungus Resistance Mil-Std 810B Method 508 Pliability Test ASTM C1224 Sound Absorption Test ASTM C423 and ASTM E795 Sound Transmission Loss ASTM E90 and ASTM E413 Water Vapor Transmission ASTM E96 Tensile Strength ASTM D751 Bleeding and Delamination ASTM C1668 E84-08 (Taped Joint Detail) Test Report # 3166908SAT-012 E84-08 (Unslit) Test Report # 3166908SAT-011 R&D Services: Resistance to the Growth of Fungi ASTM C1338-00 Test Report # RD072713FR State of California State of California Licensed Insulation Manufacturer State of Minnesota: Filed with Minnesota Insulation Standards Program R&D Services Emittance Testing ASTM C1371 R&D Services: Physical Properties Sheet Width, Length, Pliability, Water Vapor Permanence and Aged Water Vapor Permanence R&D Services: Water Vapor Transmission Test ASTM-E96 (Dessicant Method) Technical Data: Temperature Range: -60 0 to 180 0 F Nominal Thickness: 5/16 inch (.312) Weight: 0.771 oz./sq. ft. Flame Spread Index (ASTM E 84): Less than 25 Smoke Developed Index (ASTM E 84): Less than 50 Mounting Method (ASTM E 2599) Fire Rating: Class A/Class 1 Linear Shrinkage: None Reflectance (IR): 94%+ Water Vapor Transmission (ASTM E 96): 0.02 Puncture Resistance: 60 lb./in. Mold and Mildew: No Growth Emittance: Less than 0.06 Tensile Strength: 3.7 N/mm Pliability: No Cracking Hot Surface Performance: Passed (250 0 F) Note: Not for use in direct contact on surface temperatures that are 180 0 F or greater. MANUFACTURER S SUGGESTED INSTALLATION INSTRUCTIONS Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. 1. STANDARD WRAP (CIRCUMFERENCE) - ROUND OR RECTANGULAR DUCTS Make sure all metal joints, seams and penetrations are sealed. Verify circumference of the duct. an air-tight, snug seam seal). Do not leave any exposed duct or space where air can enter between the duct and the Reflectix. 2. SPIRAL WRAP DIRECTLY AGAINST DUCT - ROUND DUCTS Make sure all metal joints, seams and penetrations are sealed. Spiral wrap Reflectix around the duct, overlapping 2 as you proceed. If necessary, trim width of product to accommodate bends or diameter changes in the duct. Securely tape seams with a UL 181 approved tape (goal is an air-tight, snug seam seal). Do not leave any exposed duct or space where air can enter between the duct and the Reflectix. PLEASE NOTE REGARDING HANGERS: Strap Hanger: Wrap Reflectix with the seam at the hanger. Tape seam tightly around hanger. N16 Revised 0515