Cathodic Protection Shielding by Pipeline Coatings

Similar documents
POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES

Evolution of Pipeline Coatings Below Grade Service

Joint Industry Project Field Applied Pipeline Coatings

NACE CERTIFIED CORROSION / MATERIALS SELECTION / DESIGN / COATING / CP SPECIALIST NACE Approved Instructor

EVALUATION OF A SELF-HEALING VISCO-ELASTIC PIPELINE COATING FOR ON- & OFFSHORE CRITCAL OBJECTS

Draft. innovation in the field. Modern pipeline maintenance and new construction

OUTLINE ATMOSPHERIC CORROSION INTEGRITY MANAGMENT

PPTS OPERATOR ADVISORY: THE INS AND OUTS OF CORROSION RELEASES

A New Approach to High Performance Polyolefin Coatings

ISO : (E)

PIPELINE PRODUCTS. RD-6 Anti-Corrosion Coating System. Sales and Support:

Mears Group, Inc. Integrity Assessment for Non-Piggable Pipelines By Jim Walton

PIPELINE COATINGS TECHNOLOGY REVIEW Samuel J. Thomas, Consultant - Berry Plastics Corporation/Seal for Life; Franklin, MA

Pipeline Integrity: Combining Coating Integrity and Cathodic Protection Surveys

This document is a preview generated by EVS

Overview of Canusa-CPS. Diversity of field-applied pipeline coating technologies. Robert Buchanan Canusa-CPS, Toronto, Canada

Role of Corrosion & Field Joint Coating System Selection Criteria in Submarine Pipelines Integrity

Catasrophic Failure of Aging Underground Pipelines Is Inevitable Under Certain Corrosion Conditions

Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

Case Histories for Cased Crossings Using an Integrated Tool Approach with Long Range Guided Wave. NACE DA Conference By Joe Pikas

BSR GPTC Z TR x GM Referenced Standards Page 1 of 12

IOM3 Underground Seminar. Health and Safety Laboratory Buxton. 27 May 2010

The Hidden Damage Done (HDD?)

Evaluation of Key Performance Indicators (KPI s) in Crude Oil Transmission Pipeline

The Advancement of Direct Assessment Methodologies for Difficult-to-Assess Piping

Pipeline Coatings AUCSC Fundamentals Session Jeff Didas Matcor - Tucson, AZ

FBE PIPELINE AND REBAR CORROSION COATINGS

Pipe Coating Failures. Gregory C Hardig, CPR Corrosion Protection Resources LLC

Condensed Study Guide

Another component of the depth of cover maintenance program will be regular in-water surveys of crossings with elevated scour potential.

COMPOSITE USAGE IN THE PIPELINE INDUSTRY TAMMY BOMIA

Viscous Elastic Coatings. How solid coatings with fluid properties can eliminate typical coating rehabilitation problems in the field

Pipeline Integrity through Coatings and Cathodic Protection

SECTION POLYETHYLENE TAPE WRAPPING FOR PIPE

FEASIBILITY STUDY FOR AN UNPIGGABLE SUBSEA PIPELINE A CASE STUDY OF AN OFFSHORE PIPELINE

2009 PHMSA Pipeline Construction Workshop. Elizabeth Komiskey, P.E.

Product Guide Specification

Cost-effectiveness of Viscous- Elastic Coating for Transportation Pipelines Putting an End to Coating Disbondment

EXTERNAL PIPELINE COATING SELECTION FOR NEW AND EXISTING BURIED PIPELINES. Mick D. Brown, Ph. D.

AXALTA COATING SYSTEMS. Nap-Gard. FBE Powder Coatings. Decades of Performance. A World of Experience.

Refining Corrosion Technologist NACE-RCT-001

Standard Practice Pipeline External Corrosion Direct Assessment Methodology

Pipeline Accessories. Heat Shrink Products 4 pipes

Refining Corrosion Technologist NACE-RCT-001

Dr. Shiwei William Guan, Bredero Shaw a ShawCor Company, Canada, discusses the mitigation of pipe end coating disbondment due to long-term storage.

SPECIFICATIONS - DETAILED PROVISIONS Section Corrosion Monitoring System for Underground Piping C O N T E N T S

Standard Recommended Practice. Pipeline External Corrosion Direct Assessment Methodology

Gas Transmission NPRM. David Johnson November 10, 2016

Managing Cracks. Crack Management. Tom Bubenik DNV GL

Brian S. Wyatt Eur Ing, BSc, C Eng, MIM, FICorr, FIHT, FCS. Corrosion Control

IBP306_03 Pipeline Coatings & Joint Protection: A Brief History, Conventional Thinking & New Technologies Author: Robert Buchanan 1.

PIPELINE COATING FAILURE - NOT ALWAYS WHAT YOU THINK 1T IS. Dennis Neal Harding & Neal, Inc. 10 Wild Oak Circle Houston, TX ABSTRACT

Long-term. performance. Dr. Shiwei William Guan, Bredero Shaw,

Karina Chevil. A thesis submitted in partial fulfillment of the requirements for the degree of. Master of Science. Materials Engineering

Refining Corrosion Technologist NACE-RCT-001

EVALUATION & SELECTION OF DIRECTIONAL DRILL PIPE COATINGS. Presenter: Lou Taylor Liberty Sales & Distribution

REAFFIRMATION WITH EDITORIAL REVISION November Process Industry Practices Coatings. PIP CTSU1000 Application of Underground Coatings

oday s operators continue to face challenges in gathering quality cathodic protection (CP) data. Most operators employ indirect methods such as

PipelineCompass : Pipeline Corrosion Modeling, Prediction, Assessment & Solutions Version 9.17

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Are You Trained, Certified or Qualified to Assess Corrosion, Gouges, Dents, etc. to Meet Today s Regulatory Requirements?

MODULE SEALANTS MACRO-POLYISOBUTYLENE PRODUCT DATA SHEET

Carlos Melo University of Calgary, Canada Petroamazonas EP, Ecuador

Distribution Integrity Management. Record Requirements

Canusa-CPS Offshore Evolution & Lessons Learned Upstream Conference & Exhibition Bucharest Thursday 23 rd April, 2015

INTEGRITY MANAGEMENT FOR OLD PIPELINE SYSTEM

Introduction. The materials in this guidance document may be modified or revoked without prior notice by PHMSA management.

Testing of Composite Pipe. Khalid Farrag, Ph.D., P.E. Gas Technology Institute, GTI

Gas Transmission MAOP Verification Integrity Verification Process Oklahoma CC Pipeline Safety Conference

Dual-layer fusion-bonded epoxy (FBE) coatings protect pipelines

Large Diameter Transmission Pipeline Corrosion Control State-of-the- Art: Advances in the Steel Water Pipe Industry

Preventing and Mitigating Corrosion to Advance Pipeline Integrity Pipeline Safety Trust Conference November 2, 2017 New Orleans, LA

INTEGRATED INSPECTION AND ANALYTICAL TECHNOLOGIES FOR BURIED PIPE ASSESSMENTS

Dates of Innovation Development: January, 2014 to July 2015 Web site: Summary Description: Cathodic Protection

A comparison of DCVG measurements with in-line inspection results on a pipeline under AC influence

Cathodic Protection. Cathodic Protection for Pipelines, Storage Tanks and Process Industrial Plant Assets - 2 days. Major Benefits of Attending

Coating the World Over

National Academy of Sciences

Denso Petrolatum, Bitumen & Butyl Tapes & Protal Liquid Coatings

AC Corrosion - The Unanticipated Problem

NACE INTERNATIONAL STANDARD PRACTICE SP0169 Control of External Corrosion on Underground or Submerged Metallic Piping Systems (formerly RP0169)

HIGH TEMPERATURE INSULATED COATING AND CONSTRUCTION METHODOLOGY FOR THE MACKAY RIVER PIPELINE

Y.B. Cho. K.W. Park, K.S. Jeon, H.S. Song, D.S. Won, S.M. Lee and Y.T. Kho

Corrosion Control using Cathodic Protection for Prefabricated Buried Steel Pump Stations1

Introduction. Jeremy Hailey, P.E.

NAPCA Workshop August 19, 2010 Houston, Texas Kenneth Y. Lee Office of Pipeline Safety

External Corrosion of Oil and Natural Gas Pipelines

Paper Number:

Delmont Line 27 Incident Update

Part 1: On-land pipelines

195LiquidsCatalog.

Company Name: Property Name:

Pipeline Safety Update

THE TECHNICAL STANDARDS AND SAFETY ACT, 2000, S.O. 2000, c. 16 ( the Act ) and

Colonial Pipeline Company - Managing Operational Risk

Locations of the EUROPIPE group. Headquarters Manufacturing mill Sales office. EUROPIPE GmbH Mülheim an der Ruhr, Germany

heat Feeling the High performance corrosion protection coatings for Pipeline coatings coatings

MATERIAL STANDARD FOR COLD-APPLIED LAMINATED PLASTIC TAPE INNER-LAYER TAPE FOR TAPE COATING SYSTEM OF BURIED STEEL PIPES ORIGINAL EDITION JULY 1994

Testing of Pipeline Maintenance and Rehabilitation Coatings

Standard Recommended Practice. Stress Corrosion Cracking (SCC) Direct Assessment Methodology

Transcription:

Cathodic Protection Shielding by Pipeline Coatings Greg Ruschau Jeff Digulio ExxonMobil Upstream Company This presentation includes forward-looking statements. Actual future conditions (including economic conditions, energy demand, and energy supply) could differ materially due to changes in technology, the development of new supply sources, political events, demographic changes, and other factors discussed herein (and in Item 1A of ExxonMobil s latest Applied report Market on Form Information 10-K information Ltd., 2016 set forth Licensed under for "factors the exclusive affecting use future of LUC results" PERRAD on the "investors" downloaded page on of 17/02/2016 our website at 11:06:45. Must not www.exxonmobil.com). This be reproduced, material is not forwarded to be reproduced or distributed without without the permission. of Exxon This Mobil document Corporation. is digitally watermarked.

Outline Industry definition of CP Shielding Factors necessary for CP Shielding Issues for different coating systems How should CP Shielding be viewed 2

What is CP Shielding? Definition (from NACE SP0169, Control of External Corrosion on Underground or Submerged Metallic Piping Systems): Preventing or diverting the cathodic protection current from its intended path What are the implications of this: The function of a coating is to separate the pipe surface from electrolyte, so CP is inherently shielded Properly designed coatings, which act as strong dielectrics, should shield CP 3

Why is this distinction important? 1. Regulatory reasons CFR192.112 : to operate at alternative MAOP: Not clear or obvious what is meant by nonshielding coating Interpretation left to individual, or to a regulator 4

Why is this distinction important? 2. Integrity Management a) Pipeline Integrity is mostly managed by close interval surveys (CP potentials) and remote coating surveys DCVG, ACVG, Pearson survey, coating conductance, others. b) Pipeline Integrity can be managed by ILI, but only in piggable sections, and is a lagging indicator of a corrosion mitigation problem When CP shielding is present, must overlay (a) and (b), then identify that a problem exists No actual inspection tool for CP shielding, so difficult to address with integrity management plans 5

Function of Pipeline Coatings Most pipeline coatings are physical barriers by design, which isolate the metal pipeline from the surrounding environment conductive electrolyte A risk for corrosion exists at locations where (1) the coating disbonds and (2) electrolyte is able to enter between the pipe surface and the coating. For coatings that allow water to permeate directly, cathodic protection current may flow through the coating to the pipe surface. For those coatings that do not allow for water permeation, shielding must be further evaluated. The main issue is not whether the stand-alone coating is an insulator, but whether the coating has a tendency to disbond such that CP shielding occurs: i.e. water is present and polarization of the exposed steel surface is not possible Coatings with superior adhesion to the pipe and between layers (for multilayer systems) will demonstrate a low risk of shielding CP current. 6

Consequences of Problematic CP Shielding Possibility of undetectable external corrosion if disbonded Extra bellhole digs required to verify CIS/ILI overlays CORROSION DUE TO SHIELDING AT GIRTH WELD BY HEAT SHRINK SLEEVE 7

Damages from CP Shielding In cases where CP shielding is present, there are two degradative mechanisms: 1. Corrosion rate will be at or less than ordinary corrosion rates in the local groundwater 2. Stress Corrosion Cracking (SCC) rapid failure mechanism, but takes ~20 years before SCC initiates and becomes an integrity threat The most insidious factor for CP shielding is that it can exist for decades and will not be recognized, detected, or mitigated until an incident (Corrosion/SCC) occurs 8

How critical is the problem? All coatings, given the right conditions, can shield CP No coating will shield CP if well bonded to the substrate In the absence of electrolyte, shielding cannot occur CP shielding is, in fact, an outlier with regard to pipeline service particular combinations of circumstances must be present Do t use the presu ed possi ility of CP shieldi g as the o ly sele tio criteria But shieldi g has ee the ause of ota le failures Key points: All pipeline coatings will disbond to some extent Coatings may disbond in such a way that they are conducive to CP shielding if other conditions are met Some coatings show tendency to fail in a particular manner that may make them more susceptible to CP shielding 9

EXAMPLE Extre e o -shielding: FBE BLISTERED FBE DISCOVERED UPON EXCAVATION, ELECTROLYTE FILLED NO CORROSION EVIDENCED, HIGH PH SOLUTION INDICATIVE OF ACTIVE CP UNDER THE BLISTERS

EXAMPLE FBE Blisters Microdefects Present Defects enabling CP to permeate **INDUSTRY CONSENSUS IS THAT FBE COATINGS DO NOT TEND TO FAIL IN SUCH A WAY THAT CP SHIELDING OCCURS 11

EXAMPLE Extre e CP Shieldi g Polyethylene Tape Wrap Soil stress leading to tape wrinkling and disbonding Spiral corrosion on tapewrapped pipelines

CP Shielding by Tape Wraps **THERE ARE DOCUMENTED INDUSTRY CASES OF PIPELINE FAILURES ON DISBONDED TAPE-WRAPPED PIPELINES RESULTING FROM CP SHIELDING (NEB report MH-2-95, 1996) 13

EXAMPLE Bitumenous Enamels Wrapped with felt/asbestos, can fail in multiple ways If bitumen separates from wraps, non-shielding If bitumen + wrap disbond as unit, shielding possible 14

EXAMPLE 2-Layer Extruded Polyethylene Can disbond from soil stress Soft adhesive allows movement of topcoat vs. primer shielding can occur, but less common vs. tape wraps WRINKLING 15

EXAMPLE Liquid Epoxies/Polyurethanes Often fail by blistering defects in blisters allow CP If applied very thick, failure mode less likely to be blistering, shielding possible 16

3-Layer Polyolefins There are two major ways in which these coatings can fail: 1. Mechanical damage PE FBE Carbon Steel Typically from backfill/bedrock/handling/excavation damage - current flow is allowed through the perforation; therefore, CP shielding is not a concern. 2. Coating disbondment INTERLAYER DISBONDMENT PE FBE Carbon Steel Carbon Steel Polyolefin coatings do not absorb water and thus do not fail by blistering. Polyolefin coating disbondment is a result of poor initial bonding, due to the use of intrinsically poor adhesives and/or substandard surface preparation/application. Disbondment is uncommon in modern 3LPE/3LPP. 3-layer coatings have very high lap shear strength excellent adhesion through the system The most important activities for 3-Layer coatings are qualification (product system and applicator) and QA/QC throughout production. With proper QC, shielding has not been a problem in 3-layer polyolefins. PE FBE ADHESIVE DISBONDMENT 17

EXAMPLE Geotextile-backed Tapes Mastic with woven backing, allows CP through tape overlaps no shielding problems Susceptible to disbonding from soil stress like conventional tapes 18

Current industry interests Lab tests for shielding Focus on local coating properties only ignore the fact that a SET of conditions is what is important 19

Under-Appreciated Facts About CP Shielding CP shielding is not an inherent coating property, it is a set of conditions which must be met Provi g shieldi g is very diffi ult always other factors Other features can result in CP shielding: Pipe buried in area with significant bedrock Obstructions vaults, sheet underliners (tank farms) Poorly designed/installed CP system To date, there have not been any reported cases of CP shielding in subsea pipelines High electrolyte conductivity lead to low IR drop 20

How should CP shielding be evaluated Evaluate all factors involved in shielding Possible for shielding tendency to vary significantly along the same pipeline system 21

Summary / Conclusions CP shielding is a complex issue, it is not an intrinsic coating property All coatings designed to be good insulators key is knowing how a coating tends to fail Historically, FBE coatings show lowest tendency to shield CP, PE tape wraps show highest tendency 22

Summary / Conclusions Laboratory tests help indicate local coating properties, ut a e isi terpreted i to a go / no-go result Must evaluate more than just initial coating selection to get more accurate assessment of the potential for CP shielding problems in a pipeline system 23