EDX 600. Atomic Absorption Spectrometry

Similar documents
Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES

Dr. Jianfeng Cui, Thermo Fisher Scientific, Bremen, Germany APPLICATION NOTE AN43384

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

SIMPLIFIED MATERIALS ANALYSIS VIA XRF. Ravi Yellepeddi and Didier Bonvin Thermo Fisher Scientific (Ecublens) SARL, Ecublens/Switzerland

Final Exam. Physical Constants and Conversion Factors. Equations

Analysis of inorganic impurities in lubricating oils by ICP-MS

Advanced Materials Analysis with Micro-XRF for SEM

Fields of Application / Industry:

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Review on Agriculture and Rural Development vol. 2. (1) ISSN

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

Radial, Axial or Dual View ICP: Which Do You Choose? Manny Almeida Teledyne Leeman Labs, Inc. Hudson, NH

ADVANCE SCIENTIFIC EQUIPMENT PVT LTD

REQUEST FOR TENDER. 01 August :00 noon. Table of Contents. Introduction Programme Company Pre-requisites for Tender...

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Trace Elements in Petrochemical Samples: Achieving Excellent Analytical Results

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis

Guideline regarding analysis on Fujitsu Group specified chemical substances

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

CERTIFICATE OF ANALYSIS

FOUNDRY-MASTER Pro. First class laboratory optical emission spectrometer for complete professional metal analysisoes

Certificate of Analysis

Evaluation of methods for analysis of lead in air particulates: An intra-laboratory and interlaboratory

Extending the Capability of Portable XRF Smarter, Smaller and Faster GALM 2016

Atomic Absorption Spectrometry. The Analyzer 4 You novaa 800

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Certificate of Analysis First issued: March 2008 Version: March 2008

Determination of Elemental Impurities in Graphite-based Anodes using the Agilent 5110 ICP-OES

Panasonic Group Chemical Substances Management Rank Guidelines Analysis Method of Level 1 Prohibited Substances

Atomic Spectroscopy Solutions for Environmental Applications

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT:

Image Area YOUR PRESCRIPTION FOR USP 232/233 COMPLIANCE. USP 232 / 233 Readiness Solutions and Services Overview

National Food Safety Standard

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

Inductively coupled plasma (ICP) spectroscopy for online measurements of trace metal emissions at the 250 kw PACT furnace

1. Introduction. 2. Scope and application. 3. Objectives

OPTIMA 4000 DV Series of ICP-OES Systems

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

Certificate of Analysis First issued: March 2010 Version: March 2010

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Certificate of Analysis

9 Mineral particles, mainly windblown dust from local soil: Li, A1, Sc, (V), Cr, Fe, (Co), Ga, Y, La, Sm, Th, U;

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

ICP Expert software. Technical Overview. Introduction

EU water analysis using the Thermo Scientific icap 7400 ICP-OES Duo

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

Utilizing Glow Discharge in Optical Emission Spectroscopy

ElvaX Light for Petrochemical analysis

Standard Solutions (Traceable to NIST)

Certificate of Analysis First issued: May 2008 Version: May 2008

Analytical Instruments

Standard Solutions (Traceable to NIST)

PINAACLE 500/900 AA AND SUPPLIES CONSUMABLES. Consumables and Supplies Reference Guide

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

Process and quality control in the aluminum industry using ARL 9900 XRF-XRD integrated spectrometer

Direct Determination of Thallium in Water by Pre-concentration with the PinAAcle 900H GFAAS

Certificate of Analysis

Table I: MCL and MRL Concentrations for Contaminants Monitored Under the Safe Drinking Water Act National Primary Drinking Water Regulations

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

INCD ECOIND INTERNATIONAL SYMPOSIUM SIMI 2016 THE ENVIRONMENT AND THE INDUSTRY, PROCEEDINGS BOOK

Tender Document. National Centre of Excellence in Analytical. Chemistry, University of Sindh, Jamshoro. Inductive Coupled Plasma (ICP -OES) ISSUED BY:

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

Certificate of Analysis BS 110B

RIX3100. Fully Automated Sequential X-ray Spectrometer System. Product Information

Millennium Excalibur MEASUREMENTS OF ARSENIC, SELENIUM, ANTIMONY, BISMUTH AND TELLURIUM. with the accuracy of atomic fluorescence

was developed for the determination of thallium at the ng/ml

Analysis of Metals in Water, Stream Sediments and Floodplain Soils Collected March 21-23, 2005 from the Bayou Creek System. David J.

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Defense Technical Information Center Compilation Part Notice

Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES

Composition Analysis of Animal Feed by HR ICP-OES

CONTRIBUTIONS TO THE STUDY OF ENVIRONMENTAL POLLUTION WITH HEAVY METALS

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Agilent Atomic Spectroscopy Solutions for Energy & Chemicals AA, MP-AES, ICP-OES, ICP-MS.

Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System

TECHNICAL PRESENTATION OF THE LABORATORIES OF THE CTNDM: CAPABILITIES AND CURRENT ACTIVITIES

Rubber and plastics gloves for food services Limits for extractable substances

DETERMINATION OF SULPHUR CONTENT OF UN-ALLOYED AND LOW-ALLOYED STEEL BY ICP-AES SPECTROMETRY USING WET CHEMICAL SAMPLE PREPARATION

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

The New Wave in Spectroscopy FS-2 FluoroMate Fluorescence Spectrometer

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Background The document will be revised for its five year review and updated per the committee agreed upon changes.

Bridging new frontiers in Lab - to - Field analysis

Analysis of Samples Related to Nuclear Submarine Operation

Analysis of Heavy Metals in Iron-based Fertilizers by HR ICP-OES

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

DRPK-005

Productive. Precise. Reliable. AGILENT ATOMIC ABSORPTION SPECTROMETERS

Transcription:

Atomic Absorption Spectrometry EDX 600 AAS9000 Flame and Graphite Furnace Atomic Absorption Spectrometer AAS 8000 Graphite Furnace Atomic Absorption Spectrometer AAS 6000 Flame Atomic Absorption Spectrometer

Various Configurations to meet specific analysis demands Overview Atomic Absorption Spectroscopy is a spectroanalytical procedure for the quantitative determination of chemical elements. AAS technique is widely applied for determining the concentration of a elements in Chemistry and other fields such as metallurgy, environmental, petrochemical, industrial and pharmaceutical. Skyray Instruments Atomic Absorption Spectrometers feature low limits of detection with multiple atomization modes and state-of-the-art user friendly software. AAS Series AAS 6000 Flame Atomic Absorption Spectrometer Flame atomic absorption is applied to micro and trace metallic elements testing, covering over 30 elements including Cu, Zn, K, Na, Au, Ag and others.skyray AAS6000 Atomic Absorption Spectrometer features fast lamp switching for convinient operation. With simple structure and great testing speed AAS6000 Flame AAS is a powerful and reliable tool for micro trace analysis. AAS6000 Flame AAS AAS8000 Graphite Furnace Atomic Absorption Spectrometer Graphite Furnace Atomic Absorption is suitable for trace and ultra-trace metallic elements test, covering over 60 elements and suitable for testing Cd, Cr, Pb, Al, Mo, etc. AAS 8000 with graphite furnace auto sampler and AAS 8000-M without graphite furnace auto sampler feature low detection limits, high sensitivity and Skyray state-of-the-art user friendly software. With simple structure and great testing speed AAS8000 Graphite Furnace AAS is a powerful and reliable tool for trace and ultra-trace analysis. AAS8000 Graphite Furnace AAS AAS 9000 Integrated Atomic Absorption Spectrometer AAS 9000 Integrated Atomic Absorption Spectrometer combines flame and graphite atomizers, incorporating both Flame and Graphite Furnace features. With Skyray state-of-the-art user friendly software users can switch atomizers quickly and automatically based on their needs. Users can also choose a cost effective AAS 9000-M option which comes without graphite furnace autosampler. AAS 9000 Integrated AAS 1

Features All 8 lamps have individual power supplies. During operation 7 lamps are preheated simultaniously while the other lamp is working-thus dramatically reducing lamp switching and preheating C2H2 analysis and flame measurement: full reflection and corrected aberration Fully automatic operation Safety protection of gas circuit 230nm grating blazed wavelength, enhanced ultra-violet zone sensitivity 1800 g/mm grating density and optimized resolution System Details Optional Items 2

Advanced Software Windows based advanced analytical AAS Software User-friendly design for quick training and simplified operation One Software covers all functions- parameter setting, instrument control, data processing, spectrum display, curve fitting, status monitoring etc. Multiple Report options including Excel export Application Fields Geology, minerals, metallurgy, steel, non-ferrous metals Environmental analysis: air, water quality, soil and solid waste Petrochemical industry and light industrial products, crude oil and additional products Food, biomedicine and health products Building materials (glass, ceramic, paints, etc.) 3

Technical Specifications 4

Skyray Instruments USA, Inc 1717 N. Akard Street, Ste 2520 Dallas, Texas, 75201 USA +1 972 638 9035 sales@skyrayinstruments.com Skyray Instruments specializes in the R&D, manufacturing and sales of analytical and measuring instruments in Spectroscopy, Chromatography and Mass Spectroscopy fields. Our Products include X-ray Fluorescence Spectrometry, Atomic Absorption Spectrometry, Gas Chromatography, Inductively Coupled Plasma Spectrometry, Mass Spectrometry and many others Skyray has been providing customers around the world with reliable and affordable Scientific Instruments for more than 20 years Product description and specifications in this document are subject to change without notice. Copying, distributing or any use of material contained in this document for any commercial purpose without permission from Skyray Instruments USA, Inc is prohibited. Printed in USA