GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS:

Similar documents
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE

LF1600 Stand Assist Assembly and Operation Manual

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

SAVE THESE INSTRUCTIONS

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

1075 Fluoroscopy Stretcher

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

Owner s Manual & Safety Instructions

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

TrueClean ToteTilter TM

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

POOL STEP INSTRUCTIONS (NE1087WH)

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

DRYWALL DOLLY 900 LB. CAPACITY

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

General Guidelines. Tools Required. Safety. Deluxe Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC500-V3

UNIVERSAL UTILITY TRUCK RACK

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.

STAINLESS STEEL PEG BOARDS

General Guidelines. Tools Required. Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC400-V2. Safety

2017/ Rev-AA.0

VISE MOUNTED. Model 97359

LOAD RAMP 1000 LB. CAPACITY

Infant Warmer Care Station Cabinet Light

Precision Roller Pinion System Models RPS16, RPS20, RPS25, RPS32, RPS40 LINEAR MOTION CONTROL PRODUCTS FORM NO. L A-1204.

PalletPal Low Profile Disc Turntable

User Guide M Rev A 09/15

CR-3000 Car Rotator Capacity 3,000 lbs Installation Manual 2016 Mar

Machinery Mover. Owner s Manual

WARNING. Introduction ! ATTENTION

500XL Childbearing Bed OPERATIONS MANUAL. For Parts or Technical Assistance

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

BESTMOVE STANDING TRANSFER AID

Pallet Puller. Owner s Manual

Edge-of-Dock Leveler 'BA' - 'BX' Series. Owner s Manual and Installation Instructions

and Shield with Vertical Needle Holder REF 90072

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

C Series Mechanical Pit Levelers. P.O. Box 338 Spring Hill, Tennessee fax:

Pedestrian Flood Door

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

OptoLum MegaLine RGBW Luminaire

92831 TEL: (714) FAX:

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

Pallet Jack 4,400 Lbs Capacity Model #31001

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

DUST FREE ACTIVE Total Home Air Purification

Y SIDE ALUMINUM TRUCK RACK

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

Universal Tactical Light

HATCHSAFE Installation Instructions/Operation and Maintenance Manual Models: All Models

Instructions for Use Reprocessed Electrophysiology Catheter Cables

WARRANTY GENERAL POLICY AND RETURN GOODS PROCEDURE. For Original Equipment Manufacturers Only

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

66-Bin Wire Shelf Storage Rack

Stainless steel rolling cabinet

Process Returns in VOTW

Aero Tec Models 700 & 750 (115 vac)

7 PIECE TUBE FLARING KIT

S8VM Series Replacement Brackets

BESTMOVE STANDING TRANSFER AID

92831 TEL: (714) FAX:

117-Bin Wire Shelf Storage Rack

Installation Instructions/Operation and Maintenance Manual

Dynatronics Parallel Bars

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

GROUND MOUNT INSTALLATION MANUAL

Mechanical Post Lift. Owner s Manual

VILLAGIO FLOORS, INC. TOLL FREE: Fax: VILLAGIOWOODFLOORS.COM. Finish Warranty. Structural Warranty

The Best Around Underground

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

DRUM-GRAB INSTRUCTION MANUAL

Pallet Gate Installation Instructions and Operators Manual

55-Gallon Tilting Drum Ring

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

Instructions for Use Reprocessed Balloon Inflation Devices

PRESTO GEORUNNER FLOW PROTECTION SYSTEM INSTALLATION GUIDELINE. GRFP-V2 1 NOV Presto Products Co. All Rights Reserved.

EJOT Solar Fastenings. Installation Manual

LO-DOCK LEVELER (LD) OWNER S MANUAL AND INSTALLATION GUIDE GLOBAL GROUP INC. PROOF

Drag Chain Conveyor Installation and Operation Manual

BESTMOVE STANDING TRANSFER AID

4 rotary milling table

Mobile Drum Carrier. Owner s Manual

BBL-4 FORK-MOUNTED BULK BAG LIFTER USE AND MAINTENANCE MANUAL

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors

To Contact PS DOORS:

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

Instructions for Use Reusable Electrophysiology Catheter Cables

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

MODEL NUMBER: 1419 SERIES

Double-Drum Forklift Gripper

AUTOMATIC FOLDING DOOR

Model TS-100 Tubing Spider Installation, Operation, Service and Parts Book Manual

Transcription:

GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS: INSTALLATION & OPERATION INSTRUCTIONS FOR PATRIOT BED PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE Info: The most current version of these instructions can be found online at www.grahamfield.com. Info: Use these instructions to mount rails on Patriot Bed only. GF6580BH-1 Quarter Rails are intended for homecare use or institutional use with Patriot beds. Ensure you have read and understood the following safety information before installing or using the Quarter Rails. WARNING: Important! Read and understand these instructions before installing or using the GF6580BH-1 Patriot Liberty Quarter Rails. If you do not understand any part of these warnings, cautions or instructions, contact a healthcare professional for direction in the use of this product. If the bed rails are not properly installed and adjusted, personal injury and damage to the rails and bed could result. Please read and understand the following bed rail decal before use: For information on Bed Rail safety, please see the FDA s brochure concerning Bed Safety and Bed Rails on the FDA website, at: www.fda.gov/medicaldevices/productsandmedicalprocedures/generalhospitaldevicesandsupplies/hospitalbeds/ WARNING: Patient entrapment with bed side rails may result in serious injury or death. Use only with coherent patients capable of avoiding entrapment. Patients at risk of entrapment include those who have problems with memory, sleeping, incontinence, pain, uncontrolled body movement or who get out of bed and walk unsafely without assistance. For at-risk patients, use only with proper bed side rail protective barriers. There is also an increased risk of entrapment when bed rails are used in conjunction with a low air loss product. WARNING: Bed side rails are not restraining devices. If restraint is required, use only proper protective restraints. Follow the manufacturer s instructions and applicable regulations. Monitor patient frequently. WARNING: DO NOT push or pull the bed by the bed rails. WARNING: GF Health Products, Inc. recommends that GF6580BH-1 Quarter Rails be used with Lumex beds, and cannot guarantee their optimal performance with other manufacturers' beds. WARNING: If components are damaged or missing, contact your Graham-Field distributor immediately. DO NOT use substitute parts. Use only Lumex replacement parts. The use of non-lumex replacement parts could result in personal injury, damage the rails, and void the warranty. WARNING: Notice for California Customers- California Proposition 65 WARNING: This product contains a chemical known to the State of California to cause cancer and reproductive or developmental harm. WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury caused by improper assembly, installation or use of this product. GF6580BH-1-INS-LAB-RevD14 1

CROSSBRACE ASSEMBLY Assemble s: press the adjustment, which engages in the long slot, and slide the two sections together as shown at right. Crossbrace Position Please note that installation position differs from final position. To facilitate installation, it is necessary to expose the s that hook the s to the bed deck angle. The pictures at right will aid you during the following installation instructions. bed deck angle in installation position adjustment assemble rotated to final position long slot INSTALLATION AS HEAD RAILS Remove bedding and mattress. Ensure that the bed deck is in the flat position. Head End Pivot Point Crossbrace Installation slot pivot point detail area long end spring slot rail guide locate slots slotted head deck angle detail: install detail: installed 1. Locate the two head deck angle slots on either side of the bed closest to the pivot point, shown in above left picture. 2. Position the so it extends across the bed. Ensure the s remain at the bottom of the and rotate the s so the long ends face upward and the s face the bed's, as shown in above center picture. 3. Insert one of the s into the slot across the bed from you. Compress the spring-loaded until the second aligns with the slot closest to you and lower it into the slot. Slowly release until it locks into place. 4. Rotate the so the long ends of the s face downward and the s face the bed's, as shown in above right picture. 2 GF6580BH-1-INS-LAB-RevD14

Head End Crossbrace Installation slot detail area long end rail guide slot spring locate slots slotted head deck angle detail: install detail: head end installed 1. Locate the two head deck angle slots on either side of the bed closest to the bed's, shown in above left picture. 2. Position the so it extends across the bed. Ensure the s remain at the bottom of the and rotate the s so the long ends face upward and the s face the bed's, as shown in above center picture. 3. Insert one of the s into the slot across the bed from you. Compress the spring-loaded until the second aligns with the slot closest to you and lower it into the slot. Slowly release until it locks into place. 4. Rotate the so the long ends of the s face downward and the s face the bed's, as shown in above right picture. Head Rail Installation 1. Align the two legs of each rail over the s. Ensure the outer telescoping rail tubes are facing the bed's and the rail rivet stops are facing outward, as shown at right. 2. Gently pull out the spring s and lower the rail until both s click into position in the first holes on both rail legs, locking down the rail. WARNING: Ensure the outer telescoping rail tubes face the of the bed as shown at right; if positioned otherwise, a pinch point could occur when bed is raised or lowered. right rail outer telescoping tube rail rivet stops face outward quarter rails right side installed as head rails left rail outer telescoping tube left side s face each other GF6580BH-1-INS-LAB-RevD14 3

INSTALLATION AS FOOT RAILS Remove bedding and mattress. Ensure that the bed deck is in the flat position. Foot End Crossbrace Installation detail area slot long end spring slot rail guide locate foot end slots foot deck angle detail: install detail: installed 1. Locate the two foot deck angle slots on either side of the bed closest to the bed's, shown in above left picture. 2. Position the so it extends across the bed. Ensure the s remain at the bottom of the and rotate the s so the long ends face upward and the s face the bed's, as shown in above center picture. 3. Insert one of the s into the slot across the bed from you. Compress the spring-loaded until the second aligns with the slot closest to you and lower it into the slot. Slowly release until it locks into place. 4. Rotate the so the long ends of the s face downward and the s face the bed's, as shown in above right picture. 4 GF6580BH-1-INS-LAB-RevD14

Foot End Pivot Point Crossbrace Installation slot detail area long end rail guide pivot point slot spring pivot point foot deck angle locate slots detail: install foot end detail: installed 1. Locate the two foot deck angle slots on either side of the bed closest to the bed's pivot point, shown in above left picture. 2. Position the pivot so it extends across the bed. Ensure the s remain at the bottom of the and rotate the s so the long ends face upward and the spring s face the bed's, as shown in above center picture. 3. Insert one of the s into the slot across the bed from you. Compress the spring-loaded until the second aligns with the slot closest to you and lower it into the slot. Slowly release until it locks into place. 4. Rotate the so the long ends of the s face downward and the s face the bed's, as shown in above right picture. Foot Rail Installation 1. Align the two legs of each rail over the s. Ensure the outer telescoping rail tubes are facing the bed's and the rail rivet stops are facing outward, as shown at right. 2. Gently pull out the spring s and lower the rail until both s click into position in the first holes on both rail legs, locking down the rail. WARNING: Ensure the outer telescoping rail tubes face the of the bed as shown at right; if positioned otherwise, a pinch point could occur when bed is raised or lowered. right rail outer telescoping tube rail rivet stops face outward right side left rail outer telescoping tube s face each other quarter rails installed as foot rails left side GF6580BH-1-INS-LAB-RevD14 5

OPERATION WARNING: Always ensure the bed rails are securely installed as described before use. Lowering the Rails To lower the rails to the MID position, pull out the s and lower the rail until the s lock in the second holes. Release the s. To lower the rails to the DOWN position, pull out the s and lower the rail until it sits on the two rail rivet stops. Raising the Rails To raise the rails to the MID position, pull out the s and raise the rail until the s catch in the second holes. To raise the rails to the UP position, pull out the s and raise the rail until the s catch in the top holes. WARNING: Ensure the bed rails lock into place during adjustment, and that both ends of each bed rail are adjusted to the same height. MAINTENANCE WARNING: Inspect the bed rails frequently and adjust as needed to ensure secure installation. Cleaning To clean the bed rails, wash them with soap and water or a mild detergent, then rinse with water. s Notice: Never use abrasive cleaners or scouring pads on any part of the bed rails. 6 GF6580BH-1-INS-LAB-RevD14

LIMITED WARRANTY SCOPE OF WARRANTY GF Health Products, Inc. ( GF ) warrants to the original purchaser only that it will replace or repair components, at GF s sole discretion, that are defective in material or workmanship under normal use and service. All warranties are conditioned upon the proper use of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals, including proper use and maintenance. To the extent that a component is warranted by a third party, GF conveys all of its rights under that warranty to the original purchaser, to the extent permitted. This limited warranty shall only apply to defects that are reported to GF s customer service team within the applicable warranty period and which, upon examination by GF or its authorized representative, prove to be a warranty item. This limited warranty is not transferable. The warranted components and time period are set forth below: Lumex GF6580BH-1 Patriot Liberty Quarter Rails: three years The applicable warranty period shall commence from date of shipment to the original customer, unless there is an expiration date on the component in which case the warranty shall expire on the earlier of warranty period or the expiration date. OBTAINING WARRANTY SERVICE A GF Customer Service Representative must authorize warranty service. Please contact the GF Customer Service department by calling 678-291-3207, sending a fax request to 770-368-2386 or by e-mailing a request to cs@grahamfield.com. Specific directions will be provided by the Customer Service Representative. Failure to abide by the specific directions will result in denial of the warranty claim. EXCLUSIONS The warranty does not cover and GF shall not be liable for the following: 1) Defects, damage, or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, tampering or failure to seek and obtain repair or replacement in a timely manner; 2) Products which are not installed, used, or properly cleaned and maintained as required in the official manual for the applicable product; 3) Products considered to be of a non-durable nature including, but not limited to: casters, filters, fuses, gaskets, lubricants, and charts; 4) Accessories or parts not provided by GF; 5) Charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with such products which are not expressly authorized in writing, in advance, by GF; 6) Any labor or shipping charges incurred in the replacement part installation or repair; 7) Costs and expenses of regular maintenance and cleaning; and 8) Representations and warranties made by any person or entity other than GF. ENTIRE WARRANTY, EXCLUSIVE REMEDY AND CONSEQUENTIAL DAMAGES DISCLAIMER THIS WARRANTY IS GF S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. GF MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IF ANY MODEL OR SAMPLE WAS SHOWN TO THE CUSTOMER, SUCH MODEL OR SAMPLE WAS USED MERELY TO ILLUSTRATE THE GENERAL TYPE AND QUALITY OF THE PRODUCT AND NOT TO REPRESENT THAT THE PRODUCT WOULD NECESSARILY CONFORM TO THE MODEL OR SAMPLE IN ALL RESPECTS. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PARTS. GF SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO: DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER, OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND BENEFITS. GF6580BH-1-INS-LAB-RevD14 7

The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document, and supersede all prior negotiations, agreements and understandings with respect thereto. The recipient of this document hereby acknowledges and represents that it has not relied on any representation, assertion, guarantee, warranty, collateral contract or other assurance, except those set out in this document. For additional information on this product or this warranty, please contact a GF Customer Service Representative. NOTES: 1) Additional terms and conditions may apply. 2) Freight claims must be notated on the Bill of Lading and must be made with immediacy. The ICC regulations govern specific requirements for freight claims. Failure to abide by those regulations may result in a denial of the freight claim. GF will assist you in filing the freight claim. 3) Claims for any short shipment must be made within thirty (30) days of the invoice date. GF Health Products, Inc. 2935 Northeast Parkway Atlanta, GA 30360 Tel 770-368-4700 Fax 770-368-2386 www.grahamfield.com www.grahamfield.com GF Health Products, Inc. is not responsible for typographical errors. All illustrations, specifications, packaging and warranties contained in this literature are based on the latest product information available at the time of printing. The most current product information, including the most current version of these instructions, can be found online at www.grahamfield.com. Graham-Field and Lumex are registered trademarks, and Patriot is a trademark, of GF Health Products, Inc. 2009 GF Health Products, Inc. 2935 Northeast Parkway Atlanta, GA 30360 tel 770-368-4700 fax 770-368-2386 Made in China 8 GF6580BH-1-INS-LAB-RevD14