SECTION STEEL HEALTHCARE CASEWORK

Similar documents
SECTION OVERHEAD COILING SHUTTERS

SECTION OVERHEAD COILING DOORS

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

SECTION RESIDENTIAL CASEWORK

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ACCORDION FOLDING PARTITIONS

SECTION METAL FLAT LOCK TILE PANELS

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products.

Series - 1

A. Access doors and frames are part of an access door and frame allowance.

SECTION METAL ATHLETIC LOCKERS

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

SECTION METAL ATHLETIC LOCKERS

B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

University Apartments on Brooklyn PROJECT MANUAL

SECTION HEALTHCARE CASEWORK (SYNTHESIS CASEWORK COLLECTION BY MIDMARK)

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION METAL LOCKERS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

1. Standard two tier metal lockers and metal base.

SECTION RESIDENTIAL OVERHEAD DOORS IMPRESSION STEEL COLLECTION STEEL DOORS 5800 SERIES

SECTION DUALGARD SNOW GUARDS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ORCHESTRA PIT FILLER

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

Wood and Plastic Laminate Casework Latest revision: October 23, 2014

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

SECTION METAL STUDENT LOCKERS

Product Guide Specification

DIVISION VIII - DOORS AND WINDOWS

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

.1 [Non-rated] [fire rated] pressed steel, lead-lined steel frames. .2 [Non-rated] [fire rated] hollow metal, lead-lined doors [and panels].

SECTION IMPACT RESISTANT WALL PROTECTION

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION NON--STRUCTURAL METAL FRAMING

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION NON-STRUCTURAL METAL FRAMING

Architectural Specifications, Section Phenolic Lockers

Union County Vocational - Technical Schools Scotch Plains, New Jersey

PH6000. Key Features

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

.1 Blast-resistant non-fire rated pressed steel frames. .4 Factory supplied [and installed] glass and glazing.

SECTION DEMOUNTABLE WALLS SKY WALLS - STRATUS SYSTEM

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

SECTION DIRECTORIES

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

SECTION METAL EQUIPMENT LOCKERS

Hamilton International Air Cargo Logistics Facility Section November 2014 Page 1 of 4

Section PANEL SIGNAGE

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

SECTION STEEL WINDOWS UL Labeled Fire-Rated Fixed Lite (950) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION RESIDENTIAL OVERHEAD DOORS TRADITIONAL STEEL COLLECTION INSULATED DOORS 180/181/185 SERIES

SECTION QUARTZ SURFACING COUNTERTOPS

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

UNIFIED FACILITIES GUIDE SPECIFICATIONS


AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

Milgard Quiet Line Series Vinyl Windows 3-Part Specification

Architectural Wall Products Guide Specifications

SECTION SERIES ALL GLASS ENTRANCES

Transcription:

SECTION 12 35 70.01 STEEL HEALTHCARE CASEWORK This guide specification has been prepared by InnerSpace Corporation to assist design professionals in the preparation of a specification section covering steel casework for healthcare facilities. Movable cabinets and carts can also be included in this section. Due to the wide variety of casework components available, this section does not attempt to describe each component in detail, but instead covers the basic materials and construction. Specific model numbers can then be included in the schedule provided at the end of this section or called out on the drawings. Refer to InnerSpace Corporation literature for specific model numbers and additional information on these products. This specification may be used as the basis for developing either a project specification or an office master specification. Since it has been prepared according to the principles established in the Manual of Practice published by The Construction Specifications Institute (CSI), it may be used in conjunction with most commercially available master specifications systems with minor editing. Other InnerSpace Corporation products are covered by the following guide specifications: Section 12 35 70.02 - Stainless Steel Healthcare Casework Section 12 35 70.03 - Plastic Laminate Healthcare Casework The following should be noted in using this guide specification: Notes are included to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or hidden by one of the following methods: Microsoft Word: From the pull-down menus select TOOLS, then OPTIONS. Under the tab labeled VIEW, select or deselect the HIDDEN TEXT option. Corel WordPerfect: From the pull-down menus select VIEW, then select or deselect the HIDDEN TEXT option. Optional text requiring a selection by the user is enclosed within brackets, e.g.:?section [09000.] [.] Items requiring user input are enclosed within brackets, e.g.:?section [ - ]. Optional paragraphs are separated by an?or statement, e.g.: **** OR **** "Green" requirements are included for projects requiring LEED certification, and are included as green text. For additional information on LEEDS, visit the U.S. Green Building Council website at www.usgbc.org. This guide specification is available in a variety of electronic formats to suit most popular word processing programs. Please contact InnerSpace Corporation toll-free at 800-467-7224, by e-mail at info@innerspacecorp.com, or visit our website at www.innerspacecorp.com. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Steel healthcare casework. Edit the following paragraphs to suit project requirements and to coordinate with other sections in the project manual. InnerSpace Corporation 12 35 70.01-1 Steel Healthcare Casework

B. Related Sections: 1. Division 1: Administrative, procedural, and temporary work requirements. 2. Section [ - ]: Plumbing fixtures and trim. 3. Section [ - ]: Electrical: Electrical components and accessories. 1.2 REFERENCES Include only those reference standards that are included within the text of this section. If statements are included in Division 1 addressing the edition dates of standards, delete edition dates from the following statements. A. ASTM International (ASTM) (www.astm.org): 1. A1008/A1008M-05 - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability. 2. C1048-04 - Standard Specification for Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass. B. Underwriters Laboratories, Inc. (www.ul.com) - Product Directories. 1.3 SUBMITTALS Limiting submittals to only those actually required helps to minimize liability arising from the review of submittals. Minimize submittals on smaller, less complex products. Include the following for submission of shop drawings, product data, and samples for the Architect's review. A. Submittals for Review: 1. Shop Drawings: Include dimensioned plans, elevations, and sections; utility service locations, fixtures, and fittings; relationship to adjacent construction and anchorage details; and hardware and accessories. 2. Product Data: Indicate component configurations, dimensions, construction details, utility and service locations, materials, and finishes. 3. Samples: [3 x 3] [ x ] inch finish samples [showing available colors.] [in each specified color.] Include the following for projects requiring LEED certification. Credits are available for the use of recycled materials, and also for regional materials if the project is located within a 500 mile radius of the InnerSpace Corporation fabrication facility. B. Sustainable Design Submittals: 1. Recycled products: Indicate percentage of recycled material used in manufacture of products, and percentage classified as post consumer. 2. Regional products: Indicate location of manufacturing facility and distance from facility to project site. Include the following for projects requiring seismic anchorage of cabinets. C. Quality Control Submittals: 1. Certificate of Compliance: Certification from a registered structural engineer that anchorage systems were designed in accordance with applicable seismic requirements. 1.4 QUALITY ASSURANCE Include the following for components requiring electrical connection. A. Electrical Components: Listed by UL or other testing firm acceptable to authorities having jurisdiction. Include the following for projects requiring seismic anchorage of cabinets. InnerSpace Corporation 12 35 70.01-2 Steel Healthcare Casework

B. Design of seismic anchorage systems performed by a registered structural engineer with experience in seismic design. The following paragraph specifies a minimum level of experience required of the parties performing the work of this section. Retain if required, and edit to suit project requirements. C. Installer Qualifications: Minimum [ ] years [documented] experience in work of this Section.. 1.5 DELIVERY, STORAGE AND HANDLING A. Transport and store casework upright in protected, dry area. B. Do not cover with non vented coverings that create excessive humidity. C. Remove wet coverings immediately. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Contract Documents are based on products by InnerSpace Corporation. Include one of the following two paragraphs as applicable. Coordinate with Division 1 requirements. B. Substitutions: Under provisions of [Section [ ].] [Division 1.] C. Substitutions: Not permitted. 2.2 MATERIALS **** OR **** A. Steel Sheet: 1. ASTM A1008/1008M, cold rolled. 2. Recycled content: Minimum [8] [ ] percent. Include the following for glazed panels. B. Glass: Clear tempered, ASTM C1048, Kind FT, 1/4 inch thick. Edit the following to include only applicable hardware components. C. Hardware: 1. Hinges: Institutional type, five knuckle; two per door 4 feet or less in height and three per door over 4 feet high. 2. Pulls: Recessed flush pulls. 3. Door catches: Nylon roller spring or dual self aligning permanent magnet type. 4. Drawer slides: Full extension, ball bearing type, with integral stops preventing inadvertent drawer removal. 5. Drawer and door locks: Five pin tumbler type. Key locks [alike;] [differently;] [as directed;] furnish [four] [ ] keys per lock. 6. Sliding door sets: To suit type and size of sliding door units. 7. Shelf supports: Plated steel, adjustable type. 8. Casters: Full rotation type, minimum of two locking per unit. 2.3 ACCESSORIES A. Anchors and Fasteners: Type best suited to conditions and substrate materials. InnerSpace Corporation 12 35 70.01-3 Steel Healthcare Casework

2.4 FABRICATION A. Fabricate components of die formed sheet steel. B. Form edges and seams smooth, from continuous sheets. C. Form each unit rigid, not dependent on building structure or adjacent units for rigidity. D. Fabricate corners and joints without gaps and inaccessible spaces where dirt or moisture could accumulate. E. Maintain uniform clearances around door and drawer fronts. F. Fabricate units to accommodate utility services. Cut and drill for service fittings and outlets. G. Provide filler strips to close off spaces between cabinets and adjacent construction, of same material and finish as cabinets. H. Hem exposed edges. I. Turn down edges of shelves on each side and return front and back. J. Electric spot weld casework; grind joints smooth and flush. Include the following for glazed panels. K. Set glass in doors with gaskets and removable stops. 2.5 FINISHES Edit the following to indicate color desired. Refer to InnerSpace Corporation technical literature for assistance in making color selections. A. Steel: Manufacturer s standard textured powder coat finish, sprayed and baked, [soft white] [ ] color. B. Hardware: Satin chrome plated. PART 3 - EXECUTION 3.1 INSTALLATION A. Install casework plumb, square, and level. B. Attach fixed components to adjacent construction. Include the following for filler panels. Edit to indicate whether panels are required at all dissimilar materials or only at selected locations. C. Install filler pieces [where indicated.] [where fixed casework abuts dissimilar construction.] D. Installation Tolerances: 1. Maximum variation from plumb or level: 1/8 inch in 3 feet or 1/4 inch in any 10 feet, whichever is less. 2. Maximum offset of abutting units: 1/16 inch. 3.2 CLEANING A. Remove protective covers and packaging; clean surfaces as directed by manufacturer. InnerSpace Corporation 12 35 70.01-4 Steel Healthcare Casework

3.3 PROTECTION A. Protect casework from damage using temporary nonstaining coverings. 3.4 ADJUSTING A. Adjust doors and drawers for proper operation. B. Touch up minor scratches and abrasions to match original finish. 3.5 SCHEDULE When applicable and when not indicated on drawings, include a schedule listing the products in this section. Refer to InnerSpace Corporation technical literature for assistance in selecting specific components. Coordinate with Part 2 - Products. The following will assist in developing a schedule. DESIGNATION DESCRIPTION MODEL NUMBER COMMENTS C-1 Scope Cabinet 4800DA Keyed lock C-2 Supply Trolley 3700 Provide six trolleys C-3 Upper Cabinet 4180UC 18 inches deep, with one shelf END OF SECTION InnerSpace Corporation 12 35 70.01-5 Steel Healthcare Casework