Moduline IAC s proven modular range of acoustic construction panels

Similar documents
Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Industrial Noise Control Solutions to industrial and environmental noise problems

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

Accutone2 Architectural Enclosures

Melhart Music Center Modular Music Practice Rooms - E3 Ready Specifications Section 13034

Accutone2 Music Practice Rooms A Complete Range of High-Performance Music Practice Rooms

IAC Acoustics Moduline Noise Control Enclosures. Mark Simnick

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

Vent Silencers A complete range of products for high pressure systems

SECTION SOUND CONTROL DOORS

INC Pre-Assembled Structures

SPECIAL CONSTRUCTION SECTION SOUND CONDITIONING ROOMS FOR AUDIOMETRIC TESTING & MEDICAL LIFE SCIENCES

Series 3000 Pocket Doors

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Kinetics Noise Control

SECTION Motor Operated Horizontal Sliding Sound Control Door

2000 POCKET DOOR TECHNICAL DATA

SOUND BARRIER WALLS. Specializing in Acoustics, Noise & Vibration Control. Phone Fax Penn Street Westfield, IN 46074

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION ACCORDION FOLDING PARTITIONS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

International, Inc Evans Ave. Phone: Akron, OH Fax: SPECIFICATIONS

Modular, Durable, Easy To Install Acoustical Panels For Maximum Noise Reductions

Acoustic Louvers A Complete Range of Certified, High-Performance Acoustic Louvers to Solve Diverse Environmental Noise Pollution Problems

3000 SERIES POCKET DOOR

ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES ACOUSTIC ENCLOSURES

Uniclass L6614:N372 EPIC F5223:Y45. CI/SfB. Rh2 (P2) AUGUST 2002 GALLOWAY ACOUSTICS ACOUSTIC ENCLOSURES & SCREENS

MOBILE PANEL WALLS MOBILE WALL SYSTEMS INSPIRATIONAL IN SPATIAL FLEXIBILITY

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

Sliding Door Systems

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

Acoustic Louvers A Complete Range of Certified, High-Performance Acoustic Louvers to Solve Diverse Environmental Noise Pollution Problems

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

FOLDING WALLS MOBILE WALL SYSTEMS INSPIRATIONAL IN SPATIAL FLEXIBILITY

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

A. Submit the following in addition to the standard requirements.

Design of a standalone, modular test facility for measuring sound transmitted through a common ceiling plenum

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

1-3/4 Whisper Core Door Systems

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Galvanized System

SLIDING WALLS MOBILE WALL SYSTEMS INSPIRATIONAL IN SPATIAL FLEXIBILITY

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

ALL-ALUMINUM DOOR & WINDOW FRAMING

Acoustic Louvers ABSORPTIVE ACOUSTIC LOUVERS

Sound insulating doors

the constant partition A partition made-to-measure, adjustable with an accurary to within one millimetre to any building grid.

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

Series 5550/5551 and Series 5630/5631 Acoustic Glass Walling

TP LITE. Office Partitions. Technical guide

... Enclosures & walls. Experts in Noise Control Solutions

Bradnam s. Thermal Break WINDOWS & DOORS. Setting the standards in energy efficient window & door systems

MOBILE WALL SYSTEMS INSPIRATIONAL IN SPATIAL FLEXIBILITY

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

Model 2030 Hinged Pairs

1. Division 01: Administrative, procedural, and temporary work requirements.

6400 Series TRIPLE GLAZED THERMAL BREAK CHURCH WINDOWS America's finest custom windows MINIMUM 5 8" AIR SPACE 3 1 2" SCALE = FULL SIZE

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Ventura Office Partitions. Technical guide

Noise Control Solutions For Power Generation, Oil and Gas Applications

Superior Pre-engineered Modular Systems

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

SECTION ORNAMENTAL WELDED STEEL FENCING

THERMALLY BROKEN ALUMINUM SERIES

DICTATOR Lift Shaft System

SECTION ALUMINUM WINDOWS

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

MegaSonic 2A - Series Flush Doors

Guide Specifications- Section

Soundmaster & Modernfold TECHNICAL DATA

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SILVER LINE BUILDING PRODUCTS

Model 2020 Individual Panels / Multi-Directional

Acoustic Products. Movable Walls Acoustic Panels. moving walls. flexible space solutions

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

[Project Name] Section [ ]

Relocatable office partitions

50948-RHN Putney. 16 Jan This document includes: Windows/ Rooflights/ Screens/ Louvres. Code Section Revision Dated

MONK W20 range of mild steel windows

ACOUSTI-SEAL. Movable Walls

SOUND INVESTMENT How the Acoustical Properties of Building Products Are Measured and Why This Is Important

SECTION ACCESS DOORS AND FRAMES

The Royale Collection Aluminium windows and doors

Standard program overview fire doors

Vinyl Windows and Doors

Transcription:

Moduline IAC s proven modular range of acoustic construction panels Applications Schools Colleges Universities Music Academies Youth Organisations Features BB9 compliance depending on configuration Provides optimum acoustic rehearsal space Modular design allows relocation if required Glazed Doors Silent Ventilation 10 Standard Colours Available Proven performance

Moduline Moduline is a system of field proven and laboratory-tested modular components ideally suited for the construction of a large variety of acoustically treated spaces from simple offices to complex multi-storey structures. All basic components including wall and roof panels, doors, windows and built-in silenced ventilation systems integrate readily with each other to form a versatile, building block system which saves cost, weight and space. sound absorptive Side IAC H-Joiner PANEL PANEL Several factors must be considered for the control of the acoustical environment in any building: noise propagation and flanking paths; transmission loss characteristics of walls, ceilings and floors; compatibility of windows and doors; the noise control of HVAC systems; hardware and trim. Other considerations include the fire ratings, aesthetics, structural integrity and the ability to meet specifications at minimum cost. Moduline s complete range of preengineered components and IAC full service capabilities ensure that the architect and engineer can lay out a building for maximum efficiency and economy while fully protecting against noise and/or fire. Solid Side sound absorptive insulation ATTRACTIVE APPREARANCE Available in a variety of colours and finishes, Moduline components can be provided in primed or un-primed galvanised steel, finish painted, or coated with vinyl or fluoropolymer films for superior wear resistance in a range of architectural colours and gloss levels. FIRE AND BLAST RATINGS Optional fire Noise-Lock panels and doors and certified for both 60 and 90 minute ratings. Moduline structures and doors can also be provided to withstand 689N/m² blast load. All doors remain operable after blast. LARGE SIZES OR SPECIAL DESIGNS Moduline walls have been built to heights of over 12m. with standard and special doors, windows, wind pressure relief devices and other components. For unusual applications, the IAC engineering and R&D team is available to develop and test custom designs and hardware. WEIGHT AND SPACE SAVINGS Moduline walls are only 102mm thick, yet provide the sound conditioning required with as little as 1/ of the weight of 12mm acoustic block. Moduline therefore means savings in foundation costs and less space for walls results in in more space for the user. Ideal for existing buildings which may have floor loading limitations. BARRIER-FREE ACCESS Single or double leaf Noise-Lock doors are acoustically compatible with Moduline wall panels. Choice of manual or automatic sliding doors. Optional access plugs, quickly removable panels or moveable Trackwall panel systems offer additional accessibility. Moduline doors are provided complete with standard architectural hardware as specified, including power operated sliding door mechanisms, magnetic seals, astragals and camlift hinges for swinging doors, pressure tested strikes and latches for blast doors, and certified componenets for fire-rated doors. FULL VISIBILITY Double glazed Noise-Lock windows stop the noise, but not the view. Windows can be incorporated into any Moduline panel, door or conventional wall. COST SAVINGS Moduline structures are competitively priced and designed to meet a wide range of performance requirements. 2

A proven, cost effective method for creating acoustic structures, barriers and panels. Moduline is a range of high-performance acoustic panel systems from which IAC has successfully created complete acoustic structures and walls for over 60 years. Features Include: Guaranteed acoustic performance Combined Sound Transmission Loss (STL) and sound absorption Doors / windows and ventilation systems readily incorporated Simple, rapid assembly Strong, durable construction Fire resistant Full demountability For each individual project, it is possible to select a panel design which has the required sound transmission loss (STL) and sound absorption ratings. These ratings, amongst other details can be seen opposite. The flexibility of Moduline panels means that the following types of noise control solutions can be configured: Straight walls / barriers Partial enclosures / shields Access control, including doors, windows and hatches Complete enclosures including acoustic roofs and isolated / floating floors Silent ventilation packages for all types of enclosure from personnel shelters to power generation plant rooms 2 1 Panel - inner surface typically perforated 2 Roof apron Corner joiner IAC Noise-Lock acoustic window 6 7 8 9 10 IAC H panel joiner Isolation rail Floor panel IAC Noise-Lock acoustic door Floor channel Roof channel 9 8 7 6

Various Panel Configurations Moduline Specifications This specification covers the requirements for a building structure consisting of IAC Moduline panels and components as shown on the drawings and as manufactured by IAC Acoustics. CONFIGURATION Moduline panels and doors are rated for sound transmission loss and sound-absorption coefficients in AIS s Aero-Acoustic laboratory in accordance with applicable potions of ASTM Specifications E90, E1 and C2. Physical & Acoustic Characteristics standard moduline panels One Absorptive & one solid Side Rw 0 to XX Noise-lOck II Noise-Lock IV Noishield Regular Solid Both sides Rw to XX Noise-Lock II Hard Noishield Hard One Absorptive & one solid Side with solid center Rw to 7 Noise-Lock III Noise-Lock V Unbacked absorptive panel NRC 0.9 varitone standard Thickness 102mm 102mm 1mm Max. Panel Width 100mm 60mm 0mm Max. Panel Height 660mm 660mm Thermal Insulation Sound Transmission Loss Octave Band, Hz 6 12 20 00 1k 2k k 8k Rw Sound absorptive infill doubles as thermal insulator U = 0. W/m 2 / C (0.07 Btu/hr/ft 2 F) MASS (kg/m²) Noishield Regular 20 21 27 8 8 8 67 66 0 0. Noishield Hard 22 2 8 68 7 6.7 Noise-Lock II 27 0 2 1 0 9 67 71.9 Noise-Lock II Hard 2 0 0 7 6 7 80 78?? 1.2 Noise-Lock III 19 2 6 77 80 80 7 7 61.7 Noise-Lock IV - 2 1 2 6 7-8.1 Noise-Lock V 17 29 8 6 6 60 6.7 Sound Absorption Coefficients Octave Band, Hz 6 12 20 00 1k 2k k 8k NRC* Noishield Regular 0.89 1.00 1.00 1.00 1.00 1.00 1.00 0.9 0.9 Noise-Lock II 0.9 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.9 Noise-Lock III - 0.9 0.7 0.8 0.96 0.99 1.00 1.00 0.80 Noise-Lock IV - 0.9 0.7 0.8 0.96 0.99 1.00 1.00 0.80 Noise-Lock V 0.9 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.9 Varitone (0mm) - 0. 0.6 1.20 1.21 1.07 0.92-1.00 Varitone (100mm) - 0.97 1.9 1. 1.29 1.19 1.01-1.0 * NRC stands for Noise Reduction Coefficient and is the average of the 20, 00, 1000 and 2000Hz coefficients. It is a single number indicator of relative absorption values. Coefficients greater than 1.0 result from diffraction effects associated with limited sample size (ASTM C2-90a - 6.69m 2 ). For most applications, a maximum coefficient of 0.9 is recommended for noise reduction calculations. NOISE REDUCTION COEFFICIENT (NRC) 1.0 0.9 0.8 0.7 0.6 0. 0. 0. 0.2 0.1 Moduline Sound Absorption vs. Other construction materials 0.9 MODULINE 0. ACOUSTIC BLOCK 0.1 WOOD 0.0 PLASTER OR PAINTED CONCRETE Construction Moduline transmission loss / Weight Thickness (mm) MASS (kg/m²) Plaster / Gypsum 102 70 9 Noishield Regular 102 0. 0 Hollow mansonry block, plastered both sides Rw 17 16 Noise-Lock IV 102 8.1 Noise-Lock II 102.9 Solid Concrete, Painted 00 72 Noishield Hard 102.7 Noise-Lock III 102 61.7 7 Noise-Lock II Hard 102 1.2?? Noise reduction ratings of typical Moduline enclosures range between db and 71dB in the speech interference frequency (00, 1000 and 2000Hz) octave bands. Panel Construction and Design 1. Wall, ceiling and floor panels shall be in 102mm thick and fabricated of steel face sheets, framing members and internal reinforcements welded and riveted together to form a rugged metal-sheathed panel. Each panel shall be damped and filled with sound retardant and absorbing materials that are inert, mildew resistant, vermin proof, hydrophobic and incombustible. 2. Connecting panel joiners for stationary panels shall be fabricated on one length of roll formed steel designed and sized to prevent noise leakage while acoustically and structurally joining the panels. Steel hardware and trim shall be provided as necessary.. Fire-rated panels shall bear a label with Listing Mark of Underwriters Laboratory (UL) certifying that construction has been fire rated for 90 minutes with fire facing sound absorptive surfaces and for 60 minutes with fire facing non absorption surfaces.. Windows shall be installed in panels and shall consist of two independently supported layers of.8mm safety glass separated by an air space containing desiccant to prevent fogging and framed in acoustically tight rubber seals that provide vibration isolated suspension from the panel structure.. Demountability. The structure shall be designed to permit disassembly without deformation or damage to components. Reassembly shall be accomplished without loss of acoustic or structural integrity and without requiring any replacement parts. Noise-Lock Doors 1. Door leaves shall be a minimum of 6mm thick and fabricated of steel face sheets and internal reinforcements. Face sheets shall be attached or structurally joined only at perimeter. Leaves shall be designed and filled with sound retardant and absorptive materials that are inert, mildew resistant vermin proof, hydrophobic and incombustible. 2. Frames - Shall be welded steel construction. For renovation applications, optional split frame design shall have concealed fasteners.. Acoustic Seals - Sides and head of door and frame shall include a minimum of two sets of self-aligning, magnetic compression seals. In closed position, an acoustic labyrinth shall be created and the door held in place by magnetic force of perimeter seals at head and jambs. Bottom of door leaf shall contain continuous seal, active by gravity action of cam hinge, that compresses against floor as door is closed. Raised sills and threshold drop seals will not be permitted.. Hardware - Two IAC cam-lift butt type hinges, shall be supplied with each door leaf. Manufacturer shall provide test data showing that hinges of identical design have been cycled a minimum of 12,000 times while supporting a door leaf weighing at least 19kg.. Fire rating and blast-pressure rating (optional) - Fire rated door and frame assemblies shall be furnished UL label for clear opening up to 660x660mm. Larger sizes shall be furnished with UL Certification Report. Fire rated doors shall utilize IAC fire-resistant compression mechanisms. Blast rated doors, when specified, shall withstand a static pressure of 1psi (689N/m²) and remain operable after blast. Acoustic Performance Manufacturer shall furnish certified sound-transmission-loss and sound-absorption test data, per the schedule and taken in an acoustical laboratory with a reverberation room of at least 28m³ volume and satisfying applicable portion of ASTM Specifications E90, C2 and E1 (inert transmission loss and sound absorption requirements). Warranty Acoustic panels and components shall be guaranteed against defects in workmanship and materials for one year from date of shipment. IAC Acoustics is the foremost designer and manufacturer of noise control equipment and has been so engaged exclusively since 199. Thousands of IAC Acoustics systems are in use throughout the world. Most likely we have standard products or previously worked out solutions for your requirements. If not, our engineering and R&D departments have a proven record of solving special problems. 6 7

Head Office - Winchester, UK T: + (0) 1962 87 000 F: + (0) 1962 87 111 E: winchester@iac-acoustics.com Australia T: +61 (0) 2 8781 000 F: +61 (0) 2 972 299 E: australia@iac-acoustics.com Canada T: +1 (90) 612 000 F: +1 (90) 612 8999 E: toronto@iac-acoustics.com China T: +86 (0) 769 89899966 802 F: +86 (0) 769 89899966 810 E: china@iac-acoustics.com Denmark T: + 6 77 88 00 F: + 6 78 12 0 E: nordic@iac-acoustics.com France T: + (0) 20 0 88 88 F: + (0) 20 0 88 99 E: france@iac-acoustics.com Italia T: +9 0 7 669 F: +9 0 7 002 E: info@marvinacustica.it Spain T: + 9 21 668 F: + 9 21 629 E: espana@iac-acoustics.com UAE - Dubai T: +971 2 17 6 F: +971 2 17 7 E: dubai@iac-acoustics.com USA - Houston T: +1 (82) 0980 F: +1 (82) 0990 E: houston@iac-acoustics.com USA - Lincoln T: +1 (02) 2 7272 F: +1 (02) 2 7271 E: lincoln@iac-acoustics.com USA - New York T: +1 (718) 91 8000 F: +1 (718) 86 118 E: newyork@iac-acoustics.com Germany T: +9 (0) 216 9991 0 F: +9 (0) 216 9991 2 E: deutschland@iac-acoustics.com www.iac-acoustics.com UK-P1-PAN-029-20110-01