GROUND WATER RECHARGE

Similar documents
THE HAND DUG WELL. Version : February 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

Septic Tank Guidelines

SUBSURFACE DAMS. Action Sheet 17. What is this Action Sheet about?

40 The Double Pit Latrine

2. PLANNING AND MAKING A SOIL SURVEY

Where Does Our Drinking Water Come From?

BACKGROUND: Porosity permeability. PART I Materials Procedure EMPTY the tube.

Water for the World. Methods of Developing Sources

Water Well Decommissioning Guidelines

Drilling a tube-well inside a wide-diameter well (preliminary trials)

9. SOIL PERMEABILITY. 9.0 Why is it important to determine soil permeability?

groundwater. Because watersheds are complex systems, each tends to respond differently to natural or human activities.

General Groundwater Concepts

BIG 'O' HDPE Tubing CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE. Proudly owned and operated in Canada. aquaq.

Rainwater harvesting for Aquifer Storage and Recovery - Case Studies in Goa

BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS

Publication No. 26: Private Drinking Water Wells Types of Construction

Sherman Library Maintenance Handbook for Porous Asphalt

Permeable Pavement Facilities and Surfaces

Activity 1: Flood Storage

Groundwater Mounding Causes, Issues and Prevention

How to make a simple pit toilet and grow trees or make humus for the garden. Written by Peter Morgan

WATERBOXX PLANTING INSTRUCTIONS. AquaPro

How to make a simple pit toilet and grow trees or make humus for the garden Written by Peter Morgan

Water is a solid, liquid, & gas. 71% of earth s surface is water. Our body is two-thirds water. Fresh water water that is not salty and has little or

BIOSAND WATER FILTER. What s Inside: Household Water Treatment. Filter Details. Materials for Construction. Filter Construction.

Wastewater treatment for single houses. D. O Dowd

Introduction. A publication by Aquamor

Type 1 System Sheet Flow Sandy Soils Type 2 System [1] Concentrated Flow Clayey Soils [2] Type 3 System [1] Supplementary Trap Dispersive Soils

Movement and Storage of Groundwater The Hydrosphere

Choosing technologies...

RWASH Information System Household Access Survey. Completion notes. H2: What is the main source of drinking water used by members of your household?

Construction of a Domestic Greywater Treatment System

Presentation Outline

Background. AEM Tier 2 Worksheet Farmstead Water Supply Evaluation. AEM Principle: Glossary

The Arborloo book for Ethiopia. How to make a simple pit toilet and grow trees and vegetables

Groundwater Level and Movement

FACT FLASH. 5: Groundwater. What is groundwater? How does the ground store water? Fact Flash 5: Groundwater

Investigative Question: How do different ground surfaces impact surface water runoff, groundwater recharge, stream pollution, and erosion?

GROUNDWATER. Narrative

Spring protection. Springs. Effects of natural disasters on springs. OXFAM TB5 (draft 1 )

Watershed: an area or ridge of land that separates waters flowing to different rivers, basins, or seas. It is the interdependent web of living

To provide pupils with information about how water is collected. To check their knowledge and understanding of the information

Inflow pipe. Drain. Drain

Module 3 Design and Construction of Water Wells. For more information refer to the Water Wells That Last video (Part I Planning and Construction).

Conservation Education

The soil is a very. The soil can. The manure. Soil Characteristics. effective manure treatment system if manures are applied at the proper rate.

Groundwater. Chapter 10 11/22/2011. I. Importance of groundwater

Grouting Bilfinger Spezialtiefbau GmbH

A MYSTERY DOWN UNDER!

LeaPPS Uganda Learning for Practice and Policy on household and school sanitation and hygiene Arborloo and Fossa Alterna

Of vital importance..

Soil Permeability Demonstration

AQUIFERS AND NON POINT SOURCE POLLUTION

The Schools Ecological Sanitation Programme 2. Building an Arborloo. Peter Morgan and Annie Shangwa June 2008

***NO SEPTIC SYSTEM EXCAVATION WITHOUT AN APPROVED PERMIT IN POSSESSION****

Awesome Aquifers A DEMONSTRATION. THE GROUNDWATER FOUNDATION

Rainwater harvesting and greywater recovery - Part 1 -

Filter Tube Barriers (Instream)

CHAPTER # 4. Fate of Pollutants in the Environment

Storm Drain Inlet Protection for Construction Sites (1060)

WQ-08 ENHANCED DRY SWALE

Overview. Students will...

De-watering Activities General

Lesson 1 Introduction to Unit

Introduction to Water Supply

LAYING IBSTOCK CLAY PAVERS FOR PERMEABLE PAVEMENTS

RWSSHP Resource Manual # 3b. Spring Development. Construction Manual

SysDrain the multifunctional shaft system for efficient local collection of rainwater. Innovative products for road construction and landscaping

Landscaping Recharge Areas to Increase Spring Flow

Modular Sediment Barriers (Instream)

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

Compost Toilet. STARTER KIT No. 1

Ground Water, Wells and the Summer of 1999

Community involvement in borehole siting and construction

Construction Requirements for Confined Livestock Areas and Collection Basins

7-4 Soil. By Cyndee Crawford September 2014

Suggestions for Guideline on Borrow Pits for Water Ponds in Mozambique

Training on Roads for Water and Resilience

DE Ferro Natural Water Treatment

Groundwater. Say Thanks to the Authors Click (No sign in required)

Water Interview Fall 2010 Interview ID Number School Grade Teacher Student s Initials

Options for Sustainable Urban Drainage Strategies in Informal Settlements

Suggested Stormwater Management Practices For Individual House Lots

Best Practices for Building High-Performance Resource Roads. Road Drainage. Developed by: The Roads and Infrastructure Group

INSTALLATION INSTRUCTIONS

ECO MESH PIPE. ECO-Mesh Inc.

FERROCEMENT WATER TANKS

Building on small sites

Section 208. SOIL EROSION AND SEDIMENTATION CONTROL

PRACTICE NOTE 1: In Situ Measurement of Hydraulic Conductivity

Storm Water Permitting Requirements for Construction Activities. John Mathews Storm Water Program Manager Division of Surface Water

Section 11: Evapotranspiration Absorption Beds. 11. Evapotranspiration Absorption Beds

PROTECT OUR WATER COLORING BOOK

Filter Socks Used for Sediment Management

Introduction to Groundwater

GROUND WATER. Practice Note # water. sensitive. urban. design \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \

Water Sources. Martin Wafler, seecon international gmbh. Water Sources

Turbidity and Sediment. The Activity

Transcription:

ST 3.4 GROUND WATER RECHARGE Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

Disclaimer This manual (ST 3.4) is part of the main manual, named ST 3 Storage & Recharge. Other manuals in this range are: ST 3.1 Storage options; ST 3.2 Roof top catchments; ST 3.3 Cement Storage Tanks. Each manual can be used separately from the other manuals. This manual may be copied, or adapted to meet local needs, without permission from the authors, provided the parts reproduced are distributed free or at nominal cost, not for profit and reference to the source is made. While every care has been taken to ensure the accuracy of the information given in this manual, neither the publisher nor the author can be held responsible for any damage resulting from the application of the described methods. Any liability in this respect is excluded. This manual is based on the book 40 Green World Actions of the Gaia Movement. It is highly recommended to use this manual in combination with practical hands on training that can be supplied by Connect International. Please feel free and contact Connect International if you have any questions. Foundation Connect International Jan van Houtkade 50 2311 PE LEIDEN The Netherlands Tel./Fax +31 71 514 1111 Website www.connectinternational.nl Email info@connectinternational.nl

Table of contents ST 3.4 Ground Water Recharge... 0 Disclaimer... 1 Table of contents... 2 1 Introduction... 3 2 Testing the possibilities for a ground water recharge... 4 3 Tube recharge system... 5 3.1 Materials... 5 3.2 Installing step by step... 6 3.3 Using the tube recharge system... 8 4 Rain water harvesting with Vetiver... 9 4.1 How it works... 9 4.2 How to plant... 10 4.3 A Vetiver nursery... 10

1 Introduction Many water wells in Africa, especially hand dug wells dry up at end of the dry season. This is because more water is taken out than is coming in by the natural recharge. Reasons for limited ground water recharge can be compact topsoil layers, loss of vegetation, increased erosion, etc. There are several ways to increase the recharge of ground water. Two of the low-cost options are explained in this manual. Rainwater, that otherwise would run off to rivers or evaporate, can thus penetrate into the groundwater (aquifers). This manual explains the following recharge options: Tube recharge systems: Rain water harvesting with Vetiver: Tube recharge system Rain water harvesting with Vetiver

2 Testing the possibilities for a ground water recharge Before starting to set up a ground water recharged system, you need to find out if it will increase ground water recharge and where it should be placed. The following steps should be followed: 1) Select a well that runs dry and where people know that water does not penetrate easily into the soil. For example places where water says in puddles; 2) Find a location at least 10 metres from the well, where rainwater running on the surface can be collected. The distance should be at least 10 metres to ensure that the surface water is filtered before it reaches the well. If the area slopes, the place should be made at a location higher than the well (up stream). 3) Dig a hole with a diameter of 1 metre and 10 centimetres deep. 4) Fill the hole with water. 5) Check the hole after one hour. If there is still water after one hour, there is a good chance that a ground water recharge system will make it possible for more water to reach the ground water. It is important that this test is carries out after the first heavy rains. If the soil is very dry, it will absorb much of the water, and therefore not show the actual flow of water into the ground. If the recharge test is positive the tube or Vetiver recharge systems can be applied.

3 Tube recharge system The recharge tubes are closed by a cover tub, which is only taken off after the collected water has settled for some time, allowing particles to settle down at the bottom of the hole and the water to become clear. After having taken off the cover, the collected water flows through the recharge tube and ends up ground water. 3.1 Materials The following materials are necessary: Drainage tubes made of polypropylene (black hard plastic) or PVC with diameters of ¾ or more. Length of 3 meter or more depending on the depth of the hole; Cover tube of 1½ - 1 Piece of 0.3 meter and 1 piece of 0.5 meter; Filter tube of 1-1 Piece of 0.3 meter.

3.2 Installing step by step 1) Drill a 2 recharge hole inside the test hole. Use a step auger (soil drill) or manual drilling method such as the Baptist system. The hole should pass the compact soil layers and reach the permeable layers. The recharge hole should not reach the ground water layer (aquifer) to avoid contaminating the ground water surface water; Using the Baptist method Using the step auger 2) Test the recharge capacity of the hole after drilling 2 metres. Fill up the small hole with water (about 100 litres) and check after one hour. All the water should be disappeared within one hour. If not; continue drilling extra metres; 3) Cut the drainage tube as long as the depth of the hole. Make a filter at the bottom part by cutting slots with a hacksaw on one side for every 1.5 centimetres on a length of 3 metres (depending on the depth of the hole); 4) Connect the drainage tube with a 0.3 metre long tube of 1½ ; 5) Make a 0.5 meter cover tube of 1½. Expand one end of the cover tube by heating, so that the two 1½ tubes can be joined; PVC pipe fitted to plastic pipe with heat

6) Place a filter in the 0.3 meter 1½ tube. The filter is made of a slotted 1 tube with a cloth or sock inside. This cloth can be cleaned when dirty or be replaced; A complete system before installation Borehole 2 filled with gravel and sand 7) Place the set of tubes in the borehole in such a way that the top of the top filter part is just above the bottom level of the run off or pond; 8) Fill up the space around the tube with fine gravel or coarse sand. Seal the top part with clay; 9) Cover the drainage tube with the cover tube and dig a storage pit around the tube. The volume of this storage pit should be at least 3.000 litres. For example a pit with a diameter of 3 metre and a depths of 0.5 metre. Make sure that the tube is placed so that it can be reached when the pit is filled up with water;

3.3 Using the tube recharge system Every time it rains, water will flow back into the aquifer. If the pond is made big, more than 10,000 litres of water can be recharged. Testing needed to find out the maximum capacity of recharge. 1) When it rains the storage pit fills with water. Leave it for some hours or longer until the dirt and sediments have settled; 2) Take the cover tube off and the water in the pond will flow via the drainage tube into the ground; 3) When the pond is empty, check the filter cloth first, put back the cover tube and wait for the next rain. When the drainage tube becomes clogged, it may be opened again by swapping. Extra water pressure in the casing and filter screen should then be created by using a swabbing tool which is moved up and down in the casing (up = fast, down = slow). This will create a shock wave in the water. Repeat doing this until the water flows away normally. The swabbing tool exists of a stick with a cloth. The tool fits exactly in the casing and acts like a plunger.

4 Rain water harvesting with Vetiver Groundwater recharge is needed where there are hard soil layers or rocks in the soil, so that it is impossible to make a recharge hole. Other areas will not have the tools or the trained persons to drill recharge holes. In such situations the Vetiver recharge system can be used. The advantages are that it is cheap since the user only needs to acquire Vetiver slips (planting material) and supply the labour. 4.1 How it works Vetiver grass has roots of 2 to 3 metres length that can penetrate very hard soil layers. The roots are also called living nails. When Vetiver slips are planted close (15 or 20 cm from each other) they form a closed barrier that stops or slows down water running on the surface. The topsoil carried with the water then settles in front of the Vetiver grass and gradually build up a small dyke or barrier. Much of this water will penetrate into the ground because the water can flow along the Vetiver roots.

4.2 How to plant The Vetiver recharge system is established in the same location as one would make the tube recharge system. This means upstream and at least 10 metres from the well. The idea is to get water to accumulate in storage pits and sink into the water along the Vetiver roots. A storage pit is dug in the shape of a half circle with a diameter of at least 3-4 metres. The pit should be about 1 metre deep. It is OK to leave large stones in the pit, if they are difficult to get out. The soil that is dug out is placed downstream of the pit to form a dyke or barrier. The Vetiver slips are planted in rows on the barriers that form half circles. The water then seeps through the soil of this barrier and when it reaches the Vetiver roots, runs along the roots into the ground. It can occur that fine soil particles fill the pores in the barrier so that the water does not disappear from the storage pit. One solution is to remove the first 10-20 cm of the barrier and add new sandy or loamy soil so that it is porous again. One could also make an extra pit, as described next. 4.3 A Vetiver nursery Start by getting some Vetiver plants. If you have to transport them, keep them out of the sun and with the roots in water. Cut the leaves at 20 centimetres and the roots at 10-15 centimetres; Mix cow dung (or compost or clay) into a bucket of water; Place the Vetiver with the roots in the bucket; After 4-5 days in the shade, small new roots will appear; Separate the tillers and plant in poly bags (plastic bag with small holes used in nurseries). The better the soil of compost in the bag, the better. If available, add some fertilizer; Water them daily; After about one month the plant should have at least 2 new shoots and is ready to plant out. Before planting out they must be hardened by reducing the watering.