A. ANSI A10.32, "Personal Fall Protection Used in Construction and Demolition Operations."

Similar documents
DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

DBI-SALA Uni 8 Horizontal Lifeline Cable System

SECTION HORIZONTAL FALL PROTECTION RAIL

SECTION LATCHWAYS CONSTANT FORCE POSTS

SECTION STRUCTURE MOUNT RAILING SYSTEM

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTION METAL STAIRS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION COLD-FORMED METAL TRUSSES

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION SUSPENDED MAINTENANCE ANCHORAGE SYSTEM

Expansion Joint Covers (079513)

Trex Commercial Products page Metal Railing

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Product Guide Specification

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION ORCHESTRA PIT FILLER

SECTION METAL STAIRS

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION WATERTIGHT DOORS. A. Horizontal Sliding Flood Barrier with frame and hardware.

DIVISION [11014] SUSPENDED MAINTENANCE AND FALL PROTECTION EQUIPMENT

Expansion Joint Covers

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION MISCELLANEOUS METALS

SECTION EXPANSION CONTROL

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION EXTERIOR SUN SHADES

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

Architectural Roof and Wall Products Guide Specifications

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

SECTION PORTABLE RAILING SYSTEM

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION EXPANSION CONTROL

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

SECTION EXPANSION CONTROL

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System

SECTION EXPANSION CONTROL

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

Trex Commercial Products page Decorative Metal Railing

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

Section PANEL SIGNAGE

SECTION DECORATIVE METAL FENCES AND GATES


SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION AWNINGS

SECTION WATERTIGHT FLOOD PLANKS. A. ASTM A 36 - Standard Specification for Carbon Structural Steel.


Architectural Wall Products Guide Specifications

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION STRUCTURAL STEEL

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

Multi-Institutional Academic Health Science & Research Center Evansville, IN

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION SECTIONAL OVERHEAD DOORS

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION PERFORATED METAL. Display hidden notes to specifier. (Don't know how? Click Here)

Commission No Section

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

A. Section includes conventionally glazed aluminum curtain walls installed as stick assemblies.

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION PASS WINDOWS. 1.1 SUMMARY A. Section Includes: 1. Factory finished sliding glass, counter mounted pass windows.

Architectural Roof and Wall Products Guide Specifications

SECTION SERIES ALL GLASS ENTRANCES

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Bryan County Middle/High Renovation SECTION TELESCOPING STANDS

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION METAL WALL PANEL SYSTEM

SECTION METAL FLOOR PLATE STAIRS

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

Transcription:

SECTION 112429.13 - PART 1 - GENERAL 1.1 SECTION INCLUDES A. Provide horizontal fall protection system, including attachment carriage, attachment plates, joints, corners, system stops, rail, carriage stops and specialty components for exposed and concealed conditions as required. 1.2 REFERENCE STANDARDS A. ANSI A10.32, "Personal Fall Protection Used in Construction and Demolition Operations." B. ANSI Z359.1, "Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components." C. ASTM A747/A747M, "Standard Specification for Steel Castings, Stainless, Precipitation Hardening." D. ASTM A36, "Standard Specification for Carbon Structural Steel." E. ASTM A666, "Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar." F. ASTM A500, "Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes." G. AWS D1.1/D1.1M, "Structural Welding Code - Steel." 1. Welding rods and bare electrodes: Select according to AWS specifications for metal alloy welded. H. CSA Z259.16, "Design of Active Fall Protection Systems." I. OSHA 1926.502, "Fall Prevention Systems and Criteria and Practices." 1.3 ADMINISTRATIVE REQUIREMENTS A. Coordination: Coordinate the installation of horizontal cable fall protection system with structural supports and finish materials. October 28, 2015 112429.13-1

1.4 SUBMITTALS A. Product Data: Manufacturer's data and product information indicating the sizes, descriptions, capacities, test certifications, and other descriptive data showing in sufficient detail that the product complies with the contract requirements. B. Shop Drawings: For fabrication showing the complete fall protection system. Layout drawings of each system in relation to the supporting structure indicating the locations of properly labeled components. C. Furnish proof of installer s certification approval by manufacturer in the form of the installer's current certificate issued by the manufacture. D. Designer s Qualifications Statement. E. Systems Manual: 1. Maintenance Procedures: Including parts list and maintenance requirements for all equipment. 2. Operation Procedures: Indicating proper use of equipment for safe operation of the systems. 3. Manufacturer's catalog data indicating the sizes, descriptions, capacities, test certifications, and other descriptive data showing sufficient detail that the product complies with the contract requirements. F. Record Documents: Include a copy of Record Drawings in the systems manual. G. Warranty: Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer. H. Delegated-Design Submittal: For fall protection system, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation. 1.5 QUALITY ASSURANCE A. Perform design under direct supervision of a Professional Engineer experienced in design of this type of work and licensed in the [State] [Commonwealth] [Province] of <insert name of state, commonwealth, or province>. B. Install fall protection system by manufacturer's authorized, trained, and certified personnel. 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver materials in manufacturer's original unopened packaging. B. Store materials in original protective packaging. C. Prevent soiling, physical damage, or moisture. October 28, 2015 112429.13-2

1.7 PROJECT CONDITIONS A. Coordinate layout and installation of framing and reinforcements for fall protection system anchors. 1.8 WARRANTY A. Correct defective Work within a one year period after Date of Substantial Completion. B. Provide lifetime manufacturer warranty. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Basis of Design Product: Subject to compliance with requirements, provide 3M Fall Protection; DBI-SALA UniRail System. B. Substitutions: Not Permitted. C. Source Limitation: Obtain fall protection system and components from a single manufacturer. 2.2 SYSTEM DESCRIPTION A. Allow users to walk uninterrupted the entire length of the system and provide secure anchorage to arrest a fall. Rails form basis of anchoring system and allow carriages to run unhindered along it. 2.3 PREFORMANCE REQUIREMENTS A. Delegated Design: Engage a qualified professional engineer, as defined in Section 014000 "Quality Requirements," to design fall protection system. B. Structural Performance: Fall protection systems shall withstand the effects of loads and stresses within limits and under conditions required by [CSA Z259.16,] [ANSI A10.32,] [ANSI Z359.1,] [and] [OSHA 1926.502]. 1. Allow for multiple users, based on required system calculations. 2. System designed for <insert maximum number of individuals> simultaneous users maximum. 3. Maximum allowable force on anchors: 2698 lbs. (12 kn). 2.4 COMPONENTS A. Rail: Low profile, 1.25 inches by 1.25 inches (32 mm by 32 mm), aluminum extrusion in [9'- 10" (3000 mm)] [or] [20'-0" (6096 mm)] lengths.. October 28, 2015 112429.13-3

B. Rail Joint: Low profile, aluminum extrusion to connect to rail sections. 1. Concealed: Low profile, 2.11 inches by 6.06 inches (53.5mm by 154mm), aluminum extrusion, must be supported within 7.87 inches (200mm) by fixing back to the structure. 2. Fixed: Low profile, 5.31 inches by 6.06 inches (135mm by 154mm), aluminum extrusion, also serves as anchor and is not required to have additional supports. C. Corners: Additional bends and forms available to a radius of 7.87 inches (200 mm). 1. 90º 2. 90º external 3. 90º internal 4. 45º 5. 45º external 6. 45º internal D. System Stops: Manufacturer's standard stops which prevent rails from coming out of end anchorage bracket. E. Molded Ends: Manufacturer's standard molded ends which protect exposed edge of end rails. F. Tamper-Proof Carriage Stops: Manufacturer's standard tamper-proof, carriage stops which prevent carriages from coming off the end of the system. G. Removable Carriage Stops: Manufacturer's standard tamper-proof, carriage stops which prevent carriages from coming off the end of the system but can be removed to allow the carriages to be taken off. H. Attachment Carriages: Manufacturer s standard aluminum attachment carriage with aluminum, nylon coated wheels. A stainless steel shackle with carabiner hook which pivots for any angle connection. 1. Minimum tensile strength: 3372 lbs. (15 kn). I. Rail Fixing Components: [Aluminum] [or] [Stainless steel] connections as follows: 1. End Anchors: Manufacturer's standard anchors which secure end of the rail to structure and controls rail movement in the event of a fall. 2. Intermediate Anchors: Manufacturer's standard anchors which secure rail to structure at intervals to suit work site and structure. 3. Concealed End Anchors: Manufacturer's standard anchors which secure end of the rail to structure and controls rail movement in the event of a fall. 4. Concealed Intermediate Anchors: Manufacturer's standard anchors which secure rail to structure at intervals to suit work site and structure. (Tapped versions available.). J. Fabricated supports: Carbon steel with corrosion resistant finish. 1. Steel Plates, Shapes, and Bars: ASTM A36. 2. Steel Tubing: ASTM A500, cold formed. 3. Welding rods and bare electrodes: Select according to AWS specifications for metal alloy welded. October 28, 2015 112429.13-4

2.5 MATERIALS A. Stainless steel: ASTM A666, Type 316. B. Aluminum: [6061] [or] [6082] aluminum alloy. C. Connectors: Comply with OSHA regulation 1926.502. 2.6 FABRICATION A. Fabricate anchoring devices as recommended by the manufacturer to provide adequate support for intended use. Shop fabricate required anchorage posts using structural steel with material test certificates for full material traceability. B. Welding: AWS structural specification D1.1 by certified welders. C. Fabricate joints in a manner to discourage water accumulation. D. Finishes: 1. Stainless Steel: Electropolished for corrosion resistance. 2. Structural Steel: Zinc Galvanized for corrosion resistance. 3. Aluminum: [Anodized] [Powder coated]. 2.7 ACCESSORIES A. Fasteners: Designed to support a load on the system of 2 times the maximum design load without failure. B. Signage: Provide signs and system identification tags. C. Flashing: Comply with requirements of Section [076200 "Sheet Metal Flashing and Trim."] [077100 "Roof Specialties."] [077200 "Roof Accessories."] <insert roofing section number and roofing section title> D. Sealant: Comply with requirements of Section 079200 "Joint Sealants." PART 3 - EXECUTION 3.1 EXAMINATION A. Examine areas and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of fall protection equipment. B. Proceed with installation only after unsatisfactory conditions have been corrected. October 28, 2015 112429.13-5

3.2 PREPARATION A. Coordinate location of fall protection equipment indicated to be attached to structural substrate or surface of roofing system, and furnish anchoring devices with templates and diagrams. 3.3 INSTALLATION A. Install according to approved shop drawings and manufacturer's instructions. B. Install anchorage and fasteners in accordance with manufacturer's recommendations to obtain the allowable working loads published in the product literature and in accordance with this specification. C. Exposed work shall be true to line and level with accurate angles, surfaces and with straight square edges. Coordinate anchorage system with supporting structure. D. Do not load or stress system until materials and fasteners are properly installed and ready for service. E. Do not use until trained in the use of the system. 3.4 FIELD QUALITY CONTROL A. Provide manufacturer's certified installer to inspect installed fall protection system. B. Test fall protection system for compliance with the following requirements: 1. Ensure that system components operate as specified. 3.5 ADJUSTING A. Adjust fall protection components to function smoothly and safely. 3.6 CLEANING A. Clean components of any deleterious coatings or compounds. B. Remove loose materials, crating, and packing materials from site. 3.7 CLOSEOUT ACTIVITIES A. Demonstration: Demonstrate operation of system to Owner's personnel. 1. Briefly describe function, operation, and maintenance of each component. B. Training: Train Owner's personnel on operation and maintenance of system. October 28, 2015 112429.13-6

1. Use operation and maintenance manual as training reference, supplemented with additional training materials as required. 2. Provide minimum of two hours of training. 3. Provide training at the lifeline installation site. 4. Training to take place at the completion of the installation. END OF SECTION October 28, 2015 112429.13-7