NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

Similar documents
NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

Azure cseries. A new way to see the light. c600 c500 c400 c300 c200

Azure cseries. A new way to see the light. c600 c500 c400 c300

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

MF-ChemiBIS. Today s most comprehensive solution for your bio-imaging needs and applications. Documenting Nature

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

Advanced preclinical optical imaging. Preclinical in vivo imaging. IVIS Spectrum

Azure Biosystems Western Blotting Workflow

Innovations To Meet Your Needs

Widefield Microscopy Bleed-Through

Chemiluminescence Detection. Using UVP s ChemiDoc-It System

Optical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ

A legacy of innovation and discovery

Unrivalled Optical Imaging solutions

ChemiDoc MP Imaging System

Western Blotting. The complete range by biostep. It s all about Bio-Imaging.

Special Techniques 1. Mark Scott FILM Facility

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

ibox Explorer TM Imaging Microscope

Dino-Lite knowledge & education. Fluorescence Microscopes

High-Throughput In Vivo Bioluminescence Imaging System

OCTOPLUS QPLEX FLUORESCENCE IMAGER. for fast & powerful fast 2D Gel image acquisition

1st Faculty of Medicine, Charles University in Prague Center for Advanced Preclinical Imaging (CAPI)

SpectraMax Multi-Mode Microplate Readers

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Corona process The New ZEISS Spectrometer System for the Food Industry

Thermo Scientific ArrayScan XTI High Content Analysis Reader. revolutionizing cell biology with the power of high content

Integrated Imaging Solutions for Reliable Results

CF Dyes Next Generation Fluorescent Dyes Secondary antibody

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Wireless Gel Doc. Pacific Image Electronics Co. Booth #: Hall S1, Kevin Tseng (GM)

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Brightfield and Fluorescence Imaging using 3D PrimeSurface Ultra-Low Attachment Microplates

Multiplexed 3D FRET imaging in deep tissue of live embryos Ming Zhao, Xiaoyang Wan, Yu Li, Weibin Zhou and Leilei Peng

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

Supplementary Figures

Compensation: Fundamental Principles

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

Microscopy from Carl Zeiss

HYPERSPECTRAL MICROSCOPE PLATFORM FOR HIGHLY MULTIPLEX BIOLOGICAL IMAGING. Marc Verhaegen

Particle characterization of Metal Powders with Dynamic Image Analysis

MetaXpress High-Content Image Acquisition and Analysis Software

CapitalBio LuxScan TM. HT24 High Throughput Microarray Scanner. Exploit the full capacity of your lab

TARGETED IMAGING. Maureen Chan and Ruwani Mahathantila

SYNGENE APPLICATION TRAINING GUIDE

Real-Time PCR. Real-Time PCR meets Automation qtower 3 auto

ENVAIR lab Real-Time PCR

More on fluorescence

Absorption of an electromagnetic wave

luminometer.committed

FLOW CYTOMETRY. CyAn ADP. Analyzer

Odyssey Fc Imaging System Infrared fluorescent and chemiluminescent imaging in one system!

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

Thermo Scientific GENESYS 10S Bio spectrophotometer

Illumatool ΤΜ Tunable Light System: A Non-Destructive Light Source For Molecular And Cellular Biology Applications. John Fox, Lightools Research.

Confocal Microscopy Analyzes Cells

FT-IR. varian, inc. 660/670/680-IR.

The ingenious Fusion Optics in the Spark multimode reader

For outstanding performance in real-time PCR

D e c N o. 2 8

EDUCATION EXPERIMENT. Fluorescence of an Unknown Fluorophore. Introduction.

Accelerate cell line development. Get to your high value hits faster

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Microscopy from Carl Zeiss. DirectFRAP. News from the Cell. The New Class of Laser Manipulation for the Analysis of Cell Dynamics

TurboMass GC/MS Software

Innovative Gauging. Best Practice Best Value. In-line Non-laser Non-contact. Robust. 2D/3D. Flexible. Reliable. Exact.

CyFlow Space Your flexible flow cytometer

Biophotonics?? Biophotonics. technology in biomedical engineering. Advantages of the lightwave

Renaissance 7. Whole Body Counting Software. The Comprehensive Gamma Spectrometry Solution for Internal Contamination Monitoring Systems.

Renaissance 7. Whole Body Counting Software. The Comprehensive Gamma Spectrometry Solution for Internal Contamination Monitoring Systems.

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

CyFlow Space Your flexible flow cytometer

Vevo The Ultimate Preclinical Imaging Experience

NovoCyte Flow Cytometer

How To Choose a GeneCopoeia Luciferase System. Ed Davis, Ph.D.

Thermo Scientific TSQ Endura Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative value. with unprecedented ease

Using Sapphire700 Stain and DRAQ5 Stain for Cell Number Normalization

FS-5DXIN. The Industry Standard for Float Glass Inspection NEW. Now with New Features and High-End Inspection

Expanding Multicolor Options in Flow Cytometry with Novel Brilliant Violet TM Fluorophores. Carsten Wiethe Scientific Application Manager BioLegend

PERFORMANCE MADE EASY REAL-TIME PCR

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Cell Imaging. Cell Imaging 48

CBI Toolbox Tour 2015

See what s really in your sample

End of Year. Special Offers

ALP (alkaline phosphatase) calibrators were analyzed manually in microtiter plates to find the linearity range by following this protocol:

Experts in Femtosecond Laser Technology. DermaInspect. Non-invasive multiphoton tomography of human skin

Each question may have MULTIPLE correct answers. Select all that are correct.

INDUSTRY APPLICATIONS. Cognex delivers unmatched accuracy and ease of use in Vision Guided Robotics applications. Vision Guided Robotics

MetaXpress High-Content Image Acquisition and Analysis Software

The. universal 3D Inspection reference. advanced 3D measurement software & solutions

Discovery NM630 Innovation to expand your care.

Confocal Microscopy & Imaging Technology. Yan Wu

Imaging Quantum Dots using FUJIFILM LAS 4000

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

More choices, better detection.

Software for Automatic Detection and Monitoring of Fluorescent Lesions in Mice

AUTOMATED ONLINE WATER QUALITY MONITORING. From ZAPS Technologies Product Brochure

Transcription:

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

The NEWTON s protocol driven image acquisition is as quick as it is intuitive: adjust your exposure, save, print or quantify. Dox distribution - Ex vivo fluorescence imaging of organs at 10 h post-oral-administration Tumoral cells expressing luciferase, 6 weeks after injection SMART IMAGING SYSTEM The NEWTON 7.0 system combines high sensitivity with advanced animal-handling features and userfriendly time-saving operation. The NEWTON 7.0 proprietary optics have been specifically developed for macro imaging with high light collection capacity, incorporating a unique combination of high numerical aperture and long working distance. Bright fluorescence observation can be performed in a rapid scanning mode that shortens exposure times and minimizes specimen damage. Observation is thus possible even with slight body movement. The fast lens is also ideal for luminescence applications requiring In vivo distribution of DOX-T (DOX 1.54 mg ml -1 ) in rats longer exposure time. The advent of novel fluorescent probes has increased the demands on in-vivo fluorescence imaging systems to be able to deftly handle a variety of simultaneous signals, specifically in the IR and NIR area. Our dual magnetron filter technology ensures transmission above 90% and very narrow band cutting - meaning improved spectral separation and increased sensitivity. Our detection spectral range goes from 400 to 900nm, making the NEWTON 7.0 ideal for GFP, YFP or IR applications. The best spectral range for penetrating an animal is between 600 nm and 900 nm. With NIR and IR fluorescence detection, background is very low, and tissue autofluorescence does not limit performance. With the NEWTON 7.0 optical imaging system, you can image bioluminescent reporters like firefly luciferase and rapidly quantify the signal. The system allows you to visualize and track tumor development or disease progression in the living animal, follow the spread of a tumor, or look for drug effects. The NEWTON 7.0 interface helps you to follow the same group of animals over an extended period of time to observe changes in individual animals. FLUORESCENCE & BIOLUMINESCENCE APPS STUDIO APPLICATION LIBRARY The NEWTON 7.0 includes our revolutionary Apps Studio approach to imaging. The Apps Studio is an innovative library of applications which contains more than 40 different protocols for a wide variety of targeted and easily activated fluorescent probes and reporters. The Apps Studio contains the excitation and the emission spectra of the main fluorophores used in modern molecular biology laboratory. It also suggests the best possible system configuration in terms of light source excitation, emission filter and sensitivity level. The Apps Studio ensures reproducibility and one click image acquisition for the best ease of use. Thanks to the Spectra Capsules, the NEWTON 7.0 can accommodate up to 8 excitation channels in the IR, NIR, visible RGB and UV area. Signals can be overlayed so that several reporters can be visualized simultaneously. Each individual light source delivers a precisely defined range of the spectrum. The very tight LED spectrum is additionally constrained with a very narrow excitation filter. This means less background in the images of your sample and a higher signal to noise ratio to detect the weakest signals. The LED Spectra Capsules can be easily changed, meaning that NEWTON 7.0 can be adapted simply as the requirements of your applications evolve. A large number of dyes and stains can be used such as GFP, YFP, Pro-Q Emerald 300, Sypro-Ruby, FITC, DAPI, Alexa Fluor 680, 700, 750, Cy 3, 5, 5.5, DyeLight, IRDye 800CW, VivoTrack 680, VivoTag 750

NEWTON 7.0 SUPERIOR QUANTITATIVE RESULTS MULTISPECTRAL IMAGING CUSTOM MADE V.070 LENS NARROW BANDPASS FILTERS Ultimate linearity for precise protein Ultra-low noise imaging thanks to a dual FUSION custom made lens for Time to get the image is drastically reduced quantification over the full dynamic range. camera amplifier architecture. enhanced sensitivity and sharpness. and precious antibody can be saved. QUANTITATIVE IMAGING Sensitivity is a key feature to detect a bioluminescence or fluorescence signal. Broad linear dynamic range is necessary to compare weak and strong signals in the same image. The NEWTON 7.0 achieves the best signal to noise ratio for the lowest limits of detection. The system is extremely linear over its wide dynamics and can easily detect large intensity difference between bright and faint bands before reaching saturation. The broad linear dynamic range enables relative quantification of target proteins with confidence. NEWTON 7.0 Software ANIMAL MANAGEMENT BIOSTHESIA MODULE The BIOSTHESIA system has been specially designed for inhalation of isoflurane agents by laboratory animals. The BIOSTHESIA is a small weight device, compact and robust, which can be used as a standalone unit on a table. As it is transportable, it can be moved from one place to another in no time and can be immediately operational. The system is composed of a medical grade digital flowmeter, a precision TEC3 format vaporizer, an active charcoal filter, a breathing Fill & Drain circuit with mouse nose-cone/mask and an induction box. The BIOSTHESIA vaporizer is designed to operate with isoflurane and is calibrated using a laser refractometer, to ensure accuracy of use. In addition, our vaporizer has a safety lock function, to prevent accidental turn on - making the BIOSTHESIA vaporizer not only one of the most accurately manufactured and certified vaporizer, but one of the safest. The BIOSTHESIA could supply at the same time the induction box and the imaging rack for one, two or five mice.

Imaging Versatility Visualization and tracking of tumor development or disease progression in the living animal Signals overlay so that several reporters can be visualized simultaneously In vitro and in vivo cells migration tracking Signal quantification NEWTON 7.0 Performance Proprietary V.070 lens with f0.70 aperture 1 scientific grade CCD camera Bioluminescence detection : femtogram level Fluorescence detection : picogram level Ease Of Use Intuitive user interface One click to get the image Auto-exposure and automatic illumination control Easy to clean Animal Management Large 20x20 cm FOV for multi-subject imaging Heated animal bed EQUAFLOW breather to deliver equal gas to each nose cone to prevent unwanted animals awakening Active gas scavengers Compatible with the BIOSTHESIA gas anesthesia system Up to 5 mice Non-Invasive Imaging Imaging The NEWTON bioluminescence imaging mode allows the non-invasive detection and quantification of orthotopic, metastatic and spontaneous tumors in the whole mouse. The system allows you to monitor tumor development right from the onset and collect and compare data throughout tumor development. 3 days 7 days 14 days 21 days 28 days 37 days 43 days 50 days

NEWTON 7.0 - BT400 Bioluminescence detection PERFORMANCE Bioluminescence detection : femtogram level CAMERA & OPTICS Scientific grade CCD camera Grade 0, zero defect 400-900nm / 4.8 O.D. Image resolution: 10 megapixels Native resolution: 2200x2200 NEWTON 7.0 - FT400 Bioluminescence & fluorescence detection PERFORMANCE Bioluminescence detection : femtogram level Fluorescence detection : picogram level CAMERA & OPTICS Scientific grade CCD camera Grade 0, zero defect 400-900nm / 4.8 O.D. Image resolution: 10 megapixels Native resolution: 2200x2200 Motorized V.070 lens: f:0.70 Minimum: 4x4cm Maximum: 20x20cm ANIMAL MANAGEMENT BIOSTHESIA gas anesthesia module Heated table Choice of animal breather for 1, 3 or 5 mice HARDWARE CAPABILITIES Intelligent Darkroom concept Fully-automatic system Motorized optical lens Software controlled lighting Automatic visible lighting adjustment Auto-focus & Auto-exposure Motorized V.070 lens: f:0.70 Minimum: 4x4cm Maximum: 20x20cm ANIMAL MANAGEMENT BIOSTHESIA gas anesthesia module Heated table Choice of animal breather for 1, 3 or 5 mice HARDWARE CAPABILITIES Intelligent Darkroom concept Fully-automatic system Motorized optical lens Motorized filter wheel Software controlled lighting Automatic visible lighting adjustment Auto-focus & Auto-exposure ILLUMINATION & FILTERS Epi-illumination 8 excitation channels from blue to IR 10 position filter wheel Large choice of up to 9 customer made narrow bandpass emission filters Blue excitation - High autofluorescence Green excitation - Moderate autofluorescence Near infrared excitation - Low autofluorescence

HEADQUARTERS Vilber Lourmat ZAC de Lamirault Collegien F-77601 Marne-la-Vallee cedex 3 France Phone : + 33 (0) 1 60 06 07 71 info@vilber.com GERMANY Vilber Lourmat Deutschland GmbH Wielandstrasse 2 D-88436 Eberhardzell Deutschland Phone : + 49 (0) 7355 931 380 info@vilber.de CHINA Vilber China Room 127 Building A N 111 Yuquangying Fengtai District Beijing China Phone : + 86 1361 1131 545 info@vilber.cn Disclaimer: Vilber s NEWTON 7.0 Imager may be used in a wide range of imaging applications for research use only, including in vivo and in-vitro imaging in animals. No license under any third-party patent is conveyed with the purchase or transfer of this product. No right under any other patent claim, no right to perform any patented method, and no right to perform commercial services of any kind, including without limitation, reporting the results of purchaser s activities for a fee or other commercial consideration, is conveyed expressly, by implication, or by estoppel. Therefore, users of the NEWTON 7.0 should seek legal advice to determine whether they require a license under one or more of the exiting patents in their country. This system is not intended for sale or transfer in the United States and Canada.