Primary Concerns and Defects

Similar documents
Discussion of the Stucco Identification of All Panels

Chapter 2 Understanding The Problem

Stucco Moisture Inspection Report

Stucco Inspection Report

Stucco Moisture Inspection Report Prepared For: Mr. & Mrs. Kevin Abrahams. Providing Peace of Mind One home at a time Since 1989

Inspection Fundamentals: Stucco & EIFS

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Moisture Free Inspection Report

Accent is cracked with stains Accent is sloped away from the home Flat accent is not sealed to window

Beginning of the Course

For The Home Of: Mr. & Mrs. Sam A. Sample 123 Main Street Our Town, USA 12345

Stucco Moisture Report

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN

Stucco Moisture Testing Report

SC-01 Cross-Section. Cement Board Substrate Master Wall Mesh and Base Coat Superior Finish

Magnum Board Coatings

2019 IAQA Annual Meeting

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

PROPERTY PRESERVATION AND CAPITAL PLANNING

EXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION

Building Construction and Water Intrusion

MOISTUREFREE WARRANTY INSPECTION PROTOCOL

EIFS Rain Control EIFS. Face Sealed Perfect Barrier. Beware of EIFS: They must be done correctly They leak at joints Avoid moist sensitive substrate

Stucco Moisture Testing Report

Moisture Survey Inspection Report

Senturion TM I Wall System

EIFS Inspection Report

Finestone Stucco Ultra Wall System

R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E

Differences between EnCon Insulated Precast and EIFS

PAREXEIFS EXTERIOR INSULATION AND FINISH SYSTEM

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

WeatherSmart Air Barrier Installation Guide

Senturion TM III Wall System

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

Building Moisture Survey

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

As an architect and frequent consultant on. Making EIFS Watertight

BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Sentry Stucco Ultra Wall System

Technical Bulletin. Corporate: P.O. Box 397 Fortson Georgia FAX Technical:

Finestone Stucco System

Commercial Flashing Details

FirstEnergy Program Overview

Water Intrusion Into Buildings Forensic Investigations

SAMPLE REPORT Location:

EIFS Moisture Inspection Report

REPAIR STANDARDS AND OPTIONS

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

Forensics Engineering 8th Congress Forging Forensic Frontiers November 29 December 2, 2018, Austin, TX

Detail Booklet StoTherm ci XPS

Acrocrete Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

LP SmartSide Perfection Shingle

SITE AND BUILDING INSPECTION CHECKLIST

Distances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

Limited Leak Assessment

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

Senershield -R / Senershield -VB

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

The better way to build TM. Installation Manual NAILBASE PANELS

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Siding and Soffit Installation Guidelines

TACOMA HOUSING AUTHORITY

SUMMER VILLAGE CONDITIONS ASSESSMENT ENVELOPE BUILDING

Cascade Thermal Imaging, Inc. ~ Infrared Imaging The Non-Invasive Truth ~ Thermography Report

Aqua Coast Engineering

KARRIER PANEL - BRICK

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

A. Meet at Project site <insert number> days before starting installation.

390 Viking Circle Rio, Wisconsin DESCRIPTION TOTAL WALL SL Gold Hard Coat EIFS is a nonbearing

Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)

Property Inspection Checklist

Acrocrete Platinum CI Stucco Ultra Typical details for a premium impact and puncture resistant rain screen design cement plaster stucco system

Pre-Listing Home Inspection Checklist

SUMMARY 792 Youngfield Ct., Lakewood CO Frank Oz January 13, 2018

ReCote Finish System over Concrete

Stucco and EIFS Wall Systems

SECTION R327.3 STANDARDS OF QUALITY

Residential Building Inspections

GAF EnergyGuard Polyiso Wall Sheathing

Water Management with Drainage Wrap System Page 1 of 9

I.C.E. BLOCK (U.S. Patent No. 4,223,501) Detail Manual

Paint Failure Blues 2017, Jeffrey C. May

Presenter: Mr. Rob Orwig, P.E. Senior Forensic Engineer/Heartland Regional Manager

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

Weatherproofing Masonry For Northern Climates

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

application instructions

Groundwater Seepage. Causes of Basement Seepage and Leaks Hydrostatic Pressure

Transcription:

Primary Concerns and Defects

Primary Concerns and Defects: Home Inspector Observations: Where to Look. What to Look For. What Observed condition may mean.

Primary Concerns The points to be inspected per the InterNACHI standards are the locations where indications of concerns can be found. These points of Primary Concern are the same for all of the types of stucco that we have discussed. These points of Primary Concern are also valid for other wall cladding materials.

Observations: Primary Concerns Windows, doors Interfaces Roof (kick-outs) Balcony, porch & deck Dormers Chimney enclosures Features Quoins Water tables, cornice Eyebrows and trim Penetrations Electrical Cable, telephone AC Water Attachments Handrails Signs Lighting

Observations: Weather Tightness Joints where needed Floor line Change of substrate Joints in substrate Sealants location Windows and doors Expansion joints Sealant application Type Shape Backer rod Bonding surface Flashing Step Kick-out Balcony, decks & end dams Chimney Windows, doors Traditional Stucco or EIFS Termination accessories or Back wrapping Lath or Mesh coverage Thickness Attachment or adhesion

Kick-out Flashings 1. Kick-out or diverter flashings. These are at the bottom of the step flashings. They divert the water out of the wall and into the gutter. 2. They must be visible and daylight to deliver water on them out of walls. 3. Watch for staining on the walls below where eaves or gutter ends meet walls.

Improper (missing) kick-out flashing

Deteriorated substrate below missing kick-out.

Typical Kickout Flashing Detail

Improper or Missing Deck Flashing Deck flashings are often incomplete and unsealed. Even when present deck flashings often are missing end dams. All joists and beams must be flashed and sealed where they penetrate traditional stucco, EIFS or DEFS (DA). Watch for bulges in EIFS near corners of columns. Watch for stains on beam bottoms. Are deck beams built as troughs?

Missing deck flashing at beam.

Missing flashing at deck column. Rotted substrate below improper deck flashings.

Missing flashing at deck beam; note sag in beam. Deck beam was built as an open trough with no weatherproofing above the top of the beam; water entered and deteriorated the beam causing the beam to fail giving the sag in the deck beam.

Missing flashing at deck beam; note sag in beam. Deck beam was built as an open trough with no weatherproofing above the top of the beam; water entered and deteriorated the beam causing the beam to fail. Traditional stucco system.

Missing flashing at deck beam; note sag in beam. Deck beam was built as an open trough with no weatherproofing above the top of the beam; water entered and deteriorated the beam causing the beam to fail. Traditional stucco system.

Typical Deck Flashing Detail

The problem improperly flash deck ledgers. Deck ledger was not properly flashed on this EIFS clad house; water intrusion deteriorated ledger, substrate and some framing on this 10 year old house in Denver, Colorado.

Windows and Doors not sealed to Traditional Stucco or EIFS or DA. All EIFS manufacturers and EIMA details call for EIFS to be sealed to window and door frames. Almost all One-Coat-Stucco manufacturers and the Northwest Walls and Ceiling Bureau s Stucco Resource Guide call for Traditional Stucco to be sealed to window and door frames. Most call for drainage provisions at window and door heads.

Damage below unsealed joint at window

Improper weatherproofing of window in Traditional Stucco. If the substrate (OSB) is visible there is a problem.

Typical Moisture Drainage EIFS at Window Head

Typical EIFS to Window Jamb Details

Typical MD-EIFS Window Sill Detail

MD-EIFSWindow Sill Detail with Pan Flashing

Parapet walls with no cap flashing. Typically, EIFS & Traditional Stucco are not to be on flat surfaces; they are not roofs. Water can seep through the flat surface of the stucco. Flat surfaces are also more subject to impact damage.

Cracked and flaking HCS on bullnose parapet.

Typical Parapet Cap Flashing PB Barrier

Delamination In EIFS, EPS can delaminate from substrate. EIFS lamina can delaminate from EPS board. Delamination will typically show as a bulge in the wall. Delaminated EIFS is loose and springy; it will usually ripple when tapped. Can indicate deteriorated substrate or failed adhesive; further destructive investigation is indicated.

Bulges in delaminated EIFS can show edges of EPS boards.

Floor-line buckling Floor line buckling occurs because the floorline expansion joint was omitted. Floor line buckling is caused by cross grain shrinkage of dimensional wood framing members. Typically occurs one time in a house in the first year or two of the house s life.

Floor-line buckle in EIFS.

Floor Line Expansion Joint in Wood Framing

Incomplete backwrapping of EIFS. There should be no exposed EPS board or mesh on an EIFS installation. At grade this helps prevent wicking and termite infestation; EIFS must be kept above grade 6 to 8 inches. At higher locations on a home it helps prevent water intrusion.

Improper termination of Traditional Stucco at foundation walls. There should be no exposed substrate or sill plates at the bottom of the walls. The traditional stucco should lap the top of the foundation by at least 1 inch. At grade this helps prevent wicking and termite infestation; traditional stucco must be kept 4 inches above grade. At higher locations on a home (such as above low roofs) this helps prevent water intrusion.

Incomplete Backwrapping Exposed mesh where base coat on back wrap is incomplete.

HCS does not lap top of foundation or protect OSB substrate, OSB is exposed below HCS and HCS does not lap top of foundation wall

EIFS Laps Top of Foundation Wall

Horizontal surfaces on bands. Horizontal surfaces on EIFS and Real Stucco bands are subject to impact damage and finish delamination.

Flaking of finish on EIFS bands.

Incomplete stucco or damaged stucco. Often EIFS or Real Stucco is not properly completed in hard to get at areas. Both EIFS and Real Stucco can be impact damaged; although it is harder to damage Real Stucco. Bird prefer EIFS but I have seen bird damage to Real Stucco.

Damage to EIFS where it was touching patio slab.

Fungi If you see fungi or mushrooms growing out of a crack further investigation is needed. Mildew can grow on the surface and may not be a significant problem other than ongoing maintenance of periodically cleaning the surface.

Fungi growing out of stucco window joint.