Modal analysis and flanking sound insulation in connected panels of cross-laminated-timber at low frequencies

Similar documents
Flanking sound transmission in an innovative lightweight clay block building system with an integrated insulation used at multifamily houses

Measurement series to verify the accuracy of Stora Enso Acoustic Prediction tool - SEAP

Accuracy of Dynamic and Acoustic Analysis of Lightweight Panel Structures: A Comparison of ABAQUS and ANSYS

The Optimization of a Wooden Floor Design Based on Validated Finite Element Models

Examples of timber-frame buildings in the Netherlands

On the use of scaled models in building acoustics

Prediction of the acoustic performance of floor coverings on lightweight floors

Measurements of junction vibration level differences of timber framed constructions

Hybrid cross-laminated timber floors. Comparison of measurements and calculations

DETAILED ANALYSIS OF MEASUREMENT RESULTS OF FLANKING TRANSMISSION ACROSS A JUNCTION COM- POSED OF DOUBLE WALLS CARRIED OUT ON A HALF SCALED TEST BENCH

Research on vibration and sound radiation characteristics of ship stiffened composite plate structure

NODALIZATION OF ISOLATOR FOR FLOATING FLOOR DESIGN. C.K. Hui and C. F. Ng

Propagation of Structure-borne Sound in Lightweight Gypsum Board Walls

FLANKING TRANSMISSION IN STEEL-CONCRETE COMPOSITE FLOORS

LASD Coatings Optimized for Damping of Aluminum Intensive Vehicle Bodies

The Influence of the Shape of Slab on Heavyweight Impact Sound Reduction for an Apartment Building

LABORATORY MEASUREMENT OF THE SOUND REDUCTION IMPROVEMENT INDEX BY ACOUSTICAL LININGS DUE ONLY TO RESONANT TRANSMISSION

Acoustics 08 Paris 3059

FE MODELING OF WOODEN BUILDING ASSEMBLIES

Research of transmission loss properties of thin layered sound reduction systems for building partition elements

Laboratory Data Examining Impact and Airborne Sound Attenuation in Cross- Laminated Timber Panel Construction - Part 2

STRUCTURE-BORNE SOUND PROPAGATION ACROSS A DOUBLE LEAF TIMBER-FRAME WALL

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Sound insulation properties of building elements, considering the frequency range below 100 Hz

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING

ENGLISH SUMMARY. Rakenteiden Mekaniikka, Vol. 24 No 1, 1991 ON THE EFFECT OF NOISE AND VIBRATION TO MAN. Antero Honkasalo

Adjustable epoxy based vibration damping material for constrained-layer systems

Prediction of Acoustic Performance of Composite Steel Floors

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Experimental measurements of flanking transmission in CLT structures

CHAPTER 3 IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CUTTING TOOL SYSTEM USING VISCOELASTIC DAMPER

Int. Journal for Housing Science, Vol.34, No.2 pp , 2010 Published in the United States

Experimental investigations on acoustical retrofitting of timber floors

THE EFFECTS OF LOCAL MODES ON VIBRATION REDUCTION OF BUILDING ISOLATION. Hong Kong SAR. Hong Kong SAR.

Sound Insulation for Glass and Panel

A combined approach for base isolation design

A parametric study on the isolation of ground-borne noise and vibrations in a building using a coupled numerical model

Full-Scale Shaking Table Tests of XLam Panel Systems - Correlation With Cyclic Quasi-Static Tests

Comparison Between Measurement Techniques to Estimate Flanking Sound Transmission

This page was. intentionally. left blank

Vibration properties of a timber floor assessed in laboratory and during building construction

Relationship between flanking noise through a common ceiling plenum and plenum absorption George van Hout, John Pearse and Brian Donohue

NUMERICAL MODELLING IN ACOUSTICS, DYNAMICS AND VIBROACOUSTICS M G Smith ISVR Consulting, University of Southampton, University Road, SO17 1BJ, UK

Vibrational Analysis of Aluminum 6061 Plate

Volume II FWPRDC PN Maximising impact sound resistance of timber framed floor/ceiling systems. Page 183

Comparative Impact Performances of Lightweight Gym Floors

Improving the sound insulation of construction boards with a high damping glue

APPARENT SOUND INSULATION IN COLD-FORMED STEEL-FRAMED BUILDINGS

ACOUSTIC EFFICIENCY OF FALSE CEILINGS: STUDY ON THE INFLUENCE OF DISTANCE FROM THE CEILING SLAB

Impact Noise Reduction of Underfloor Heating Systems

Prediction of airborne sound transmission across a timber-concrete composite floor using Statistical Energy Analysis

CAN THE IMPACT SOUND IMPROVEMENT OF FLOOR COVERINGS BE MEASURED ON A WOODEN MOCK UP INSTEAD OF A TIMBER JOIST FLOOR?


WIND TURBINES. Vibration Control of: Wind Turbines APPLICATIONS POWER GENERATION - WIND TURBINES

Dynamic Design of the Foundation of Reciprocating Machines for Offshore Installations in Persian Gulf

Rainfall and impact noise measurements on metal roof tiles

A NEW EMPIRICAL PREDICTION APPROACH FOR GROUNDBORNE VIBRATION IN BUILDINGS

The effect of additional thermal lining on the acoustic performance of a wall

Floating Floor Attenuation of Impact Structure-borne Sound in Timber Construction

EXPERIMENTAL AND FINITE ELEMENTS ANALYSIS OF A TUNED MASS ABSORBER FOR VIBRATION ISOLATION

Façade insulation at low frequencies influence of window design

SEISMIC PROTECTION OF MACHINERY, BUILDINGS AND EQUIPMENT OF NUCLEAR POWER PLANTS BY USING 3-D BASE CONTROL SYSTEMS

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

SOUND INVESTMENT How the Acoustical Properties of Building Products Are Measured and Why This Is Important

A simplified approach to impact sound insulation rating without using a tapping machine

Acoustic Testing of CLT and Glulam Floor Assemblies Nordic Engineered Wood Report No. A August 2016 CONSTRUCTION

Transactions, SMiRT-22 San Francisco, California, USA - August 18-23, 2013 Division V

CHAPTER 4 PIEZOELECTRIC MATERIAL BASED VIBRATION CONTROL

Available online at ScienceDirect. Transportation Research Procedia 14 (2016 )

SET PROJECT STRUCTURAL ANALYSIS OF A TROUGH MODULE STRUCTURE, IN OPERATION AND EMERGENCY Luca Massidda

EIS Materials Workshop - Building a Semi-Anechoic Room

Chapter 5 Airborne sound insulation

J. NEGREIRA DIVISION OF ENGINEERING ACOUSTICS, LUND UNIVERSITY

SOUND- PROOFING SHERPA CONNECTION SYSTEMS

Rainfall and impact noise measurements on metal roof tiles

Prediction and control of motorcycle engine noise under combustion load. Ulhas Mohite Niket Bhatia

Effect of implementation quadruple glazing panel into the walls on the airborne sound insulation of building facades

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

Vibration Isolation of Buildings. Resilient Bedding of Buildings

Measurement of room-to-room airborne sound insulation with an access floor in a dwelling unit of condominium

DETERMINING THE STATIC STIFFNESS OF STRUCTURES: A COMPARISON OF METHODS INVOLVING MEASUREMENT OF DISPLACEMENT AND MEASUREMENT OF ACCELERATION RESPONSE

International Journal of Advance Engineering and Research Development

ELASTICALLY SEPARATED FLOOR

SOUND- PROOFING SHERPA CONNECTION SYSTEMS

Steel reinforced timber structures for multi storey buildings

Analysis of Harmonic Behaviour of Human Rhythmic Activity in A RCC Roof Slab

SOLUTIONS FOR TIMBER STRUCTURES ACOUSTIC INSULATION

Laboratory measurements of the reduction of transmitted impact sound by floor coverings on a heavyweight reference floor (According to ISO )

Since there is not a standard procedure to carry out this type of test, the next methodology was followed:

Forced vibration testing of a thirteen storey concrete building

Experimental study of sound insulation performance in the wood-framed building

Slim floor coverings for refurbishment of old buildings. L. Weber, A. Fügmann Fraunhofer Institute for Building Physics (IBP), Stuttgart

Machine / Equipment Isolation REGUPOL-ACOUSTICS.COM

CHAPTER 6 FINITE ELEMENT ANALYSIS

SoundPro CDM-ISO-LAT. Acoustic solution for floating isolated floors

On the necessity of open cooperation between gearbox supplier and wind turbine OEM to avoid wind turbine tonalities

The uncertainty in sound insulation of an industrially prefabricated lightweight timber construction

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 A METHODOLOGY TO MEASURE THE ACOUSTIC PERFORMANCE OF ACCESS FLOORS

STATISTICAL ENERGY ANALYSIS OF A HIGH SPEED ELEVATOR CAB AND FRAME

Influence of design and leakages of the window-wall connection on the sound insulation.

Transcription:

Modal analysis and flanking sound insulation in connected panels of cross-laminated-timber at low frequencies Blasius Buchegger Laboratory for Building Science, University of Technology, Graz, Austria. Heinz Ferk Laboratory for Building Science, University of Technology, Graz, Austria. Martin Schanz Institute of Applied Mechanics, University of Technology, Graz, Austria. Summary Improving the flanking sound insulation performance of timber based constructions at low frequencies is a big challenge, mostly caused by the low mass of the material timber. Additional linings on the walls increase the sound insulation, but in most cases, the effect of this measure is strongly limited to lower frequencies above 100 Hz. However, there is a high potential to use the physical effect of modal decoupling to increase the flanking sound insulation especially for constructions of cross-laminated-timber at low and very low frequencies. Floors and walls are defined as single subsystems within a system of two coupled rooms. These subsystems only show local modes, if they are not connected to each other. In contrast, connected subsystems result in global modes of the overall system, if the individual local modes have similar eigenfrequencies. In this case, an excitation of a wall or a floor results in a high vibration response of the coupled wall. If the generation of these global modes is suppressed, the flanking sound insulation especially at low frequencies can be increased. This effect is studied in this contribution using validated numerical models based on the finite element method. Selected constructions have been chosen which are based on panels of cross-laminated-timber. Further, the results of 3D-models of coupled rooms are discussed. These results verify the applicability of this approach for common practical situations, and show the potential to obtain a basic sound insulation at low frequencies by a special design of cross-laminated-timber panels. PACS no. 43.20.Ks, 43.40.Dx, 43.40.Rj, 43.40.Ka 1. Introduction At the present time, the number of new timberbased multi-storey houses is growing in several countries worldwide. The usage of crosslaminated-timber is increasing due to several ecological and economical reasons and is also driven by the interesting mechanical performance of this material. Although the number of buildings is growing, two major challenges reduce the competitiveness of cross-laminated timber compared to massive construction methods like concrete or masonry: moisture sensitivity and sound insulation. With regard to sound insulation, timber constructions often allow an advanced sound insulation at higher frequencies caused by, e.g., the high material damping. At low frequencies, timber constructions show a different behaviour caused by the low density that dominates the sound insulation. Additional linings on the walls or floors increase the sound insulation especially at frequencies above 100 Hz, but have less effect on the sound insulation at lower frequencies. In Figure 1, results of standardized measurements [1] of the normalized impact sound pressure levels of various modifications of a cross-laminated timber floor construction are compared. Especially the typical shapes of the results show that the level increases with decreasing frequency. At low frequencies, plate resonances like bending modes are strongly excited caused by the low mass of the Copyright 2018 EAA HELINA ISSN: 2226-5147 All rights reserved - 1541 -

panel. Additional linings like a resilient layer and a floating floor or an additional suspended ceiling increases the sound insulation significantly, but have less influence below 100 Hz. Figure 1. Comparison of floors a) CLT, 5s, 140 mm b) Sit. a) with additional gravel filling, impact sound insulation and floating floor; c) Sit. b) with additional suspended ceiling Improvements in the low frequency range may be archieved by adding mass, e.g. gravel fillings. But this measure decreases advantages of the construction material like low cost and fast mounting. Alternatively, additional impact sound insulation and a floating floor reduce the direct sound transmission. Additional resilient linings on the walls help to reduce flanking sound transmission. These measures are based on a decoupling effect of a resonating system with an eigenfrequency that sometimes coincide with the bending mode frequencies of the CLT-panels. As a consequence, resilient linings have no sufficient effect at low and very low frequencies, sometimes the sound insulation gets even worse there. Excitation by walking noise often results in a noise spectrum containing energy especially at low frequencies. This is caused by the wide impulse in the time domain which is a consequence of typical footgear used in dwellings. As a result, the modes of the panel are strongly excited and a high noise level occurs at single eigenfrequencies. In many cases this noise results in an annoying effect on neighbours because of its tonal character. During evaluations of noise immission, this tonal character can be taken into account by adding a surcharge of several decibels [2]. Alternatively, an improvement of the sound insulation can be reached by using special acoustic effects like modal (de-)coupling. Amongst others, flanking sound transmission especially at low frequencies - is depending on the correlation of the vibration fields of the coupled panels. In general, every single panel shows eigenfrequencies and mode shapes that characterize the vibration behaviour of the component. The junction may couple these local mode shapes to global mode shapes, if two or more components have similar eigenfrequencies. This principle can be shown using an advancement of the classical SEA called the Statistical Modal Energy Distribution Analysis. Here, the so called modal interaction work is calculated by coupling each mode of the source plate to each mode of the receiving plate [3]. The distinction of local and global modes was investigated by Hopkins [4]. He observed that considering only local modes of the uncoupled system to approximate global modes leads to unsatisfying results, although suitable boundary conditions of the junction are assumed. This aspect has been taken into account during the investigations described in this proceeding by calculating the full structure. Amongst others, Gibbs and Craven [5] investigated the influence of a variation of stiffness or plate thickness on coupled panels of concrete at frequencies higher than 100 Hz. They have shown that differences in stiffness or plate thickness can have strong influence on flanking sound transmission. In building practice, materials like concrete allow only small variations in bending stiffness, because the possible range for changing the panel thickness or Young s Modulus is strongly limited. Cross-laminated timber shows a high range of variations of the bending stiffness, caused by the high number of possible compositions of the panel. Here, we discuss the effect of modal (de-)coupling by numerical studies based on the finite-elementmethod (FEM). 2. Fundamental assumptions 2.1. Numerical calculations The resonant structure borne sound transmission can be described by the transfer mobility between oscillating subsystems. To show the principle of this approach for coupled plates, numerical studies have been performed based on the finite element - 1542 -

method, with a focus on flanking sound transmission. Figure 2 shows the calculation model and the chosen boundary conditions. The model contains two coupled panels, a floor and a wall forming a L-shape junction, and an air-borne sound field. The size of the room is 3 m x 3 m and the thicknesses of the panels are 0,1 m. The wall has been coupled to the air-borne sound field. The floor panel has been excited using a rain-on-theroof excitation of the surface (unique force and arbitrary phase over the surface). a) Figure 3. Resulting mesh of the calculation model for studies in the fundamental approach b) c) The model has been studied in the frequency domain based on modal superposition of the eigenfrequencies within a frequency range of 20 Hz to 100 Hz. 5000 frequencies have been calculated using a linear distribution within the frequency range. Figure 2. Geometry and boundary conditions of the calculation model for studies in the fundamental approach: a) panel 1; b) panel 2; c) air-borne sound field; fixed constraint at single points (blue); coupling of structure and air-borne sound field (green); rain-onthe-roof excitation (red) A linear elastic, isotropic material model has been chosen to model the structure. The corresponding parameters and values are shown in Table I. A hysteretic damping with a value of 0,1 (-) has been chosen to avoid strong resonant peaks in this basic model. Quadratic shape functions have been used for the structure and the air-borne sound fields. Figure 3 shows the resulting mesh based on tetrahedron elements. A ver Table I. Material data of the structure and of the air Parameter ρ (kg/m³) Material data E (GPa) ν (-) c (m/s) structure 470 10,7 0,2 - air 1,2 - - 343 2.2. Results and discussion Each of the subsystems in Figure 4 shows local modes. If the eigenfrequencies of two systems coincide, a global mode occurs which results in a high flanking sound transmission. Subsystem 1 Subsystem 2 Subsystem 3 Figure 4. Resulting subsystem structure of the model for flanking sound transmission (red) and direkt sound transmission (blue) In principle, global modes arise if the panels show the same size, boundary conditions and material data. A decoupling of the global to local modes occurs, if the properties are changed in a suitable way. We construct two extreme cases. First, the - 1543 -

model has been solved to obtain the expected global modes using identical material parameters for the two panels. Second, the Young s modulus of panel 2 has been changed to 60 % of the one of panel 1 to reduce the influence of these global modes. For both situations, the resulting sound pressure level is evaluated. Figure 5 shows the results of the spatial averaged sound pressure level within the room, normalized to the maximum of the two situations. As discussed above, the identic sizes, boundary conditions and elastic parameters of the two panels (green graph) leads to a global mode at 57,175 Hz and results in a strong resonant peak (see also Figure 6). A reduction of the Young s modulus of panel 2 leads to a reduction of the coupling of the local modes of panel 1 and panel 2 (see also Figure 7). As a consequence, the peak of the sound pressure level in the room is decreased (blue graph). Figure 5 also shows that at low and very low frequencies, low modal density and modal overlap arise. Single resonances at defined frequencies dominate the structural and air-borne sound fields (resonant peaks in Figure 5). As mentioned before, these eigenfrequencies can have a very annoying effect on the neighbours caused by the high levels and tonal (sinusoidal) character of the noise. Figure 6. Global mode caused by identical panels (Frequency = 57,18 (Hz) - left legend: total acoustic pressure field (Pa); right legend: out-of-plane displacement of the structure (m); Figure 7. Decoupling of the local modes to reduce the energy transmission (Frequency = 57,16 (Hz) left legend: total acoustic pressure field (Pa); right legend: out-of-plane displacement of the structure (m) 3. Application to cross-laminated timber Figure 5. Normalized sound pressure level in the receiving room results for calculations using identic Young s moduli of the two panels (green graph); results for calculations using a reduced Young s modulus for panel 2 (blue graph) 3.1. Numerical calculations Based on the assumptions stated in the former chapter, a 3D-calculation model of two adjacent rooms has been investigated. The walls are made of panels of cross-laminated timber. The aim is to - 1544 -

investigate the influence of modal coupling especially to impact sound insulation. A room with a base area of 15 m² (5 m x 3 m) and a height of 2,7 m has been implemented (base area of a typical sleeping room). Figure 8 shows the model. To allow a practical boundary condition for the junctions, the upper walls are additionally implemented to form junctions in a T-shape. To approximate several floors, the displacements on the side faces have been set equal to zero, marked in Figure 9 in red. The floor was excited using a rain-on-the-roof excitation with a unique force and an arbitrary phase. The geometry has been meshed using tetrahedron elements with a maximum element size of 0,15 m. F1 F2 Figure 8. Calculation model of two vertical rooms based on the finite element method; F1: flanking wall 1; F2: flanking wall 2 The cross-laminated timber panels have been modelled using several continuous layers of wooden boards. The parameters of the used linear elastic, orthotropic material model are depending on the fiber orientation. Table II shows the chosen material properties, an index of 0 represent the parameters in-fiber-direction and an index of 90 represent the parameters perpendicular-to-fiber direction, as described by Kohrmann [6]. To allow a comprehensive investigation that is comparable with common used values, hysteretic damping has been implemented using a constant value of 0,01 for spruce [7]. Figure 9. Fixed constraints (displacement equal to zero) to approximate rigid ceilings and floors (left); rain-onthe-roof excitation of the floor (right) Figure 10. Resulting mesh of the geometry using thetrahedron elements Table II. Material data of the structure and of the air Parameter CLT [6] ρ (kg/m³) 470 kg/m³ Material data E 0 /E 90 (GPa) 10,98/ 0,137 ν 0 /90 - ν 90 /90 (-) 0,052/ 0,3 c (m/s) Air 1,2 - - 343 - Table III. Compositions of the wall designs for parametric study Thickness (mm) Floor Wall Composition Layer 1 34 19 27 30 40 19 Layer (mm) 2 30 19 34 34 40 19 Layer 3 34 19 27 30 40 19 Layer 4 30 19 Layer 5 34 19-1545 -

The thicknesses of the layers of the flanking panels have been varied using compositions as shown in table III. The layers of the floor were constant. Every possible combination of the resulting flanking walls has been calculated in the frequency domain, based on modal superposition. The investigated frequency range was defined from 17 Hz to 113 Hz. These values are the approx. lower and upper cutoff frequencies of the onethird-octave bands at center frequencies of 20 Hz and 100 Hz. 695 Frequencies were solved using a logarithmic distribution within the frequency range. 3.2. Results and Discussion The results of the calculation for the above described models show the influence of the panel composition on the formation of global modes (variable layer thicknesses in table III). Caused by the low mass and high bending stiffness of the panels of cross-laminated timber, they often show a low modal density and -overlap especially in the frequency range of 20 Hz to 100 Hz. Variations in bending stiffness lead to a shift of the eigenfrequencies of the single panel. These variations can be caused by a variation of the compositions of the single panels. Using an adjusted combination of the panels, the eigenfrequencies can be separated from each other to reduce the reaction of adjacent panels respectively the air-borne sound field, as shown in chapter 2. Table IV contains the results of a selected low-level solution (case 1) and a selected high-level solution (case 2) derived from all solutions of this parameters study. pressure level caused by resonances of the airborne sound field. Figure 11 shows the resulting sound pressure level in the receiving room, normalized to the maximum of the two situations within the investigated frequency range. As expected, some combinations of the parametric study result in high and some in low impact sound level. In several and especially in the two chosen cases, the aspect of modal decoupling was evident. A typical rule of thumb in building acoustics states that increasing mass leads to an increasing sound insulation. Here, additionally a different observation was made. In case 1, panels of smaller thicknesses are calculated that result in lower mass than case 2, but case 1 result in an evidently higher sound insulation than case 2. In figure 11, the mean value of the sound pressure level over the investigated frequency range is shown to allow an objective comparison. A comparison of the mean values within the investigated frequency range shows an improvement of 10,1 (db) SPL, by using less material for the flanking walls. Table IV. Comparison of a low-level (case 1) and a high-level (case 2) solution Thickness (mm) Floor Case 1 Case 2 F1 F2 F1 F2 Layer 1 34 19 27 30 40 Layer 2 30 19 34 34 40 Layer 3 34 19 27 30 40 Layer 4 30 Layer 5 34 Panel 162 57 88 94 88 F1+F2 145 214 Especially the high-level solution includes strong coupled global modes that lead to a high sound Figure 11. low-level (case 1) and high-level (case 2) solution of the parametric study spatial averaged sound pressure level in the receiving room ( ): case 1: green; case 2: red; mean values (---): case 1, green, -37.3 (db); case 2, red, -27.2 (db) Within the frequency range from approx. 50 Hz to 65 Hz, case 2 shows strong resonances. Figure 12 shows the results of a detailed analysis of the two cases. A different kind of coupling of the subsystems is observed that lead to the high sound pressure in the receiving room. Caused by the same sizes of the rooms for both cases, the mode shapes and the eigenfrequencies of the room are assumed to stay constant (a 1 a 4 ). - 1546 -

r 1 ) r 2 ) r 3 ) r 4 ) g 1 ) g 2 ) g 3 ) g 4 ) a 1 ) a 2 ) a 3 ) a 4 ) r 1 ) r 2 ) r 3 ) r 4 ) g 1 ) g 2 ) g 3 ) g 4 ) a 1 ) a 2 ) a 3 ) a 4 ) Figure 12: Detailed analysis of the different cases Normalized sound pressure level of the case 1 (green) and the case 2 (red); Mode shapes of case 1 (g i ), case 2 (r i ), and the air-borne sound field (a i ) - 1547 -

Modes of case 1 are defined by g 1 -g 4 and modes of case 2 are defined by r 1 -r 4. For case 2 (red), a high level occurs in the receiving room, because on the one hand, the frequencies of structural modes are similar to one of the modes of the room. Additionally, anti-nodes of mode shapes of the structure show a high spatial correlation with antinodes of mode shapes of the air-borne sound field near the boundary. This can be observed by a comparison of r 3 / a 3 for the floor (direct transmission) and by r 4 a 4 for the flanking wall (flanking sound transmission). The structural mode r 1 with the frequency of 40,1 Hz differs by several Hz from resonances of the airborne sound field, a 1 (33,7 Hz) and a 3 (57,0 Hz). Compared to other resonances, this structural mode leads to a reduced sound pressure level. The highest sound pressure level is evident at nearly 57 Hz, where a strong resonance of the air-borne sound field occurs (a 2 ). This high sound pressure level is caused by the structural, global resonance at 55,5 Hz (r 2 ) that is additionally strongly coupled to the airborne sound field because of the similar eigenfrequencies. The excitation of the floor leads to a high vibration response. On the one hand, the vibration of the floor excites the airborne sound field at its resonance (direct sound transmission). On the second hand, the floor excites the flanking wall at its resonance frequency (global mode) and subsequently the flanking wall excites the airborne sound field at its resonance (flanking sound transmission). Case 1 also shows that a high coupling of a local mode of the flanking wall (g 1 ) with the resonance of the airborne sound field (a 1 ) leads to a higher sound pressure level in the receiving room. But in contrast to case 2, the structural mode of case 1 (g 2 ) is local on both flanking walls and its eigenfrequency differs from the eigenfrequencies of the airborne sound field (a 2 ). This difference of the eigenfrequencies leads to a significant lower sound pressure level than in case 2 in the corresponding frequency range. The structural mode of g 3 can be assumed as local and therefore the response of the airborne sound field is reduced compared to case 2. The eigenfrequencies of modes r 4 and g 4 nearly coincide with the resonance a 4. Although the mode g 4 seems to be a global mode, this mode is not strong coupled to the (excited) floor, therefore the effect on the resulting sound pressure in the airborne-sound field is nearly comparable for both cases. Conclusions Here, the impact sound insulation of constructions based on panels of cross-laminated timber at low and very low frequencies is investigated. Local modes of single components of the structure lead to global modes. An additional coupling of these global modes to the airborne sound field leads to a high sound pressure level in the room. This high level can be avoided by a suitable design of the single panels. For this purpose, the stiffness and the eigenfrequencies of panels of cross-laminated timber is modified by varying the composition of the single layers. A separation of the eigenfrequencies leads to a modal decoupling which shows a high potential for increasing the impact sound insulation especially at low and very low frequencies. Improvements of the sound insulation can be achieved by using less construction material. Further investigations will show, how the approach works using different room sizes and variations of the junctions of the CLT panels. Acknowledgement The first author gratefully acknowledges funding by the Austrian Federal Ministry of Science, Research and Economy, as well as the Austrian trade association for timber within the framework of the PhD initiative DokIn Holz. References [1] ISO 10140-3:2015: Acoustics - Laboratory measurement of sound insulation of building elements - Part 3: Measurement of impact sound insulation. 2015. [2] G. Müller: Beurteilung von Schallimmissionen: Gesetze Vorschriften Normen Richtlinien. ed. Berlin, Heidelberg: Springer, 2017. [3] À. Aragonès, L. Maxit, and O. Guasch: A graph theory approach to identify resonant and non-resonant transmission paths in statistical modal energy distribution analysis. Journal of Sound and Vibration, vol. 350, pp. 91-110, 2015. [4] C. Hopkins: Structure-borne sound transmission between coupled plates. PhD Thesis, Heriot-Watt University, 2000. [5] B. Gibbs and P. Craven: Sound transmission and mode coupling at junctions of thin plates, part II: Parametric survey. Journal of Sound and Vibration, vol. 77, pp. 429-435, 1981. [6] M. Kohrmann: Numerical Methods for the Vibro- Acoustic Assessment of Timber Floor Constructions. PhD Thesis, Technical University of Munich, 2017. [7] M. Möser: Technische Akustik. vol. 10, Springer, 2015. - 1548 -