T/C, Noble, Straight Ceramic

Similar documents
Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5

General Information, Industrial Thermocouple Section

Industrial Thermocouples

STRAIGHT BASE METAL THERMOCOUPLE ELEMENTS

INSULATED ELEMENT TWIST WELD DUPLEX INSULATED TIG WELD 1 1/2 NOMINAL ORDER CODES. INSULATOR DIMENSIONS (inches) SINGLE DUPLEX

A thermocouple assembly generally has four major components:

5. SHEATH MATERIALS, THERMOWELLS, FITTINGS AND TERMINATIONS

Metal Transitions HIGH TEMPERATURE

Thermocouple Quick Reference Guide. Aluminium Temperature Sensing Solutions from the Smelter to the Foundry

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX

6. SHEATH MATERIALS, THERMOWELLS, FITTINGS, AND TERMINATIONS

MGO INSULATED THERMOCOUPLES INDEX

Overview. A thermocouple assembly generally has four major components:

Sheathed Thermocouple Sensor (120 Series)

AccuTru ExL High Temperature Thermocouples

Thermocouples W A T L O W

Industrial Thermocouples

Infinite Thermal Solutions Inc. Thermocouples and RTDs

Industrial Thermocouples

Thermocouple for Flue Gas Temperature Measurements,

Section 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2

Industrial Process Thermocouples

Thermal Solutions Worldwide SECTION M. Technical Information. Thermocouple Material Specifications M-1. Thermocouple Initial Material Tolerances M-2

Resistance Temperature Detectors (RTD)

Industrial Thermocouples

Thermocouples and Accessories Product Catalog

Thermocouple cable and assemblies ENCLAD

INDUSTRIAL TEMPERATURE SENSORS

SANDELIUS INSTRUMENTS, INC.

Thermocouple Heads. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model No.) B-9 76 (3) Model Price Material Type Number Each 48 (1 7 8)

Model 410 Threaded Straight Thermowell. Model 411 Threaded Tapered Thermowell. Model 412 Threaded Reduced Tip Thermowell 1.

MI Tube Skin Thermocouple Assembly

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

Liquid & Electrical Feedthroughs

THERMOCOUPLE TECHNICAL REFERENCE DATA

STAINLESS STEEL SHEETS

Platinum Resistance Thermometer (PRT) Selection Guide

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

W A T L O W. Application. Over 704 C (1300 F) Carburizing hardening. Inconel 600, Type 446 SS. Hot blast main Inconel 600 Stove trunk Inconel 600

AEROSPACE MATERIAL SPECIFICATION

PFA (Fluororesin) coated temperature sensors

Mineral Insulated (MgO) Thermocouples

SENSOR CATALOG STANDARD AND CUSTOM DESIGN / IN-HOUSE MANUFACTURE

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

SANDELIUS INSTRUMENTS, INC.

Thermocouples for Ultra High Temperature Technologies

Available J, K, T, E, R, S, J, K, T, E J, K, T, E J, K, T, E J, K, T, E J, K, T, E, N

Thermowells and Assemblies

THERMOCOUPLE TECHNICAL REFERENCE DATA

AccuTru Sensor Technologies

RAMA CORPORATION RAMA CELL HEATERS ESTABLISHED 1947

Incoloy Alloy 800H/800HT (UNS N08810/088011)

BI-METAL DIAL THERMOMETERS

Thermocouple Reference Table

Table of Contents PAGE

General Purpose Thermocouples

Mineral Insulated (MgO) Thermocouples

High Temperature Thermocouple Assemblies

General Purpose Thermocouples

High Temperature Thermocouple Assemblies

Process Variables. Process Variables. Temperature Strain Level Flow Pressure

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Resistance Temperature Detectors

Start-Up Procedure For Model EM-46, EM-810

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

TWF11, TWF16. Technical Information. Metal or ceramic thermowells For high temperature assemblies TAF11 and TAF16 Adjustable process connection

Thermocouple temperature sensor omnigrad T -TSC 310

Resistance Temperature Detectors

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

Innovative Temperature Measurement in Heat Treatment Processes

SANDVIK 253 MA TUBE AND PIPE, SEAMLESS

ATI 332 ATI 332. Technical Data Sheet. Stainless Steel: Austenitic GENERAL PROPERTIES TYPICAL ANALYSIS PHYSICAL PROPERTIES

Chapter 2.5: Insulation & Refractories

E (4 std) (1/4 std) 1. Calibration (See page 13 for other Cals) 3. Junction Grounded Ungrounded

NATIONAL CERTIFICATE (VOCATIONAL) NQF LEVEL 3 NOVEMBER

SURFACE TEMPERATURE SENSORS

How To Select And Use The Right Temperature Sensor

ISO 9001:2008 certified

TEMPSENS Instuments (I) Pvt. Ltd is a part of Pyrotech group which was established by four technocrats in 1976 at Udaipur, with our first product as

THERMOCOUPLES & RTDS

Connector Selection Guide

AISI D2 Cold work tool steel

02 Our Mission. 05 Letter From The President. 06 Company Overview. 08 Speed...Beyond Measure. Speed, Service, Solutions Beyond Measure

1-Materials Science & Materials Engineering

Thermocouple Reference Table

SECTION 2: PROBES. Page 2-1

Nickel & Stainless Steel. Product Range

Duraflex and Megaflex can be tested under simulated operating conditions prior to shipment. Environmental Test Chamber. In-house X-Ray Capabilities

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

In most industrial applications, temperatures are typically

JAI Engineers UK Limited. Advanced Technical Ceramic Precision Products

Haseeb Ullah Khan Jatoi Department of Chemical Engineering UET Lahore

NEW Items. Wire Rope and Accessories. Eye Nuts, Bolts and Turnbuckles. Roller Chain. kent-automotive.com NI1

SECTION PACKAGE BOOSTER PUMP STATIONS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

PRECISION MEASUREMENTS manufactures a complete thermocouple line including assemblies for chemical, power, primary metals and plastic industries.

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

Accessories. Page. Fittings. Thermowells. Protection Tubes. Connectors. Connection Heads and Blocks Transmitters. Accessories WATLOW

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2

MSE-226 Engineering Materials

Transcription:

Introduction T/C, Noble, Straight Ceramic Thermocouple, Noble Metal Ceramic Tube, Straight Applications Ordering Information Elements are constructed of high quality material using modern techniques to construct the hot junction. Other high quality components are designed to meet rugged requirements. Mullite protection pipes (Field 5, codes 23, 24, 25) are impervious to gases at high temperature. They have good resistance to thermal shock but poor resistance to mechanical shock; they should be mounted vertically. Aluminum oxide protection tubes (Field 5, codes 29, 30, 31 and 34) have fair resistance to thermal shock and mechanical shock. They are impervious to gases up to 3200 F. Primary metal industry, heat treat furnaces, forging furnaces and bright annealing. Suitable for ceramics and glass industries. Salt baths in general, Barium Chloride salt baths up to 2350 F, and high speed salt baths. Semi-conductor manufacturing and research laboratories. B24I B25I B26I R24I R25I R26I S24I S25I S26I C24I F24I HL Model No. - - 0 0 - - 0 0 Field No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Schedule: S3 Fields 1, 2, 3. THERMOCOUPLE TYPE; WIRE GAUGE Determine length by completing Fields 8, 9 Type Wire Gauge Limits 12 Min. Ea. Add l 1 B24 - B Pt, 6% Rh v Pt, 30% Rh 24 standard B25 - B Pt, 6% Rh v Pt, 30% Rh 25 special B26 - B Pt, 6% Rh v Pt, 30% Rh 26 standard R24 - R Pt, 6% Rh v Pt, 30% Rh 24 standard R25 - R Pt v Pt, 13% Rh 25 special R26 - R Pt v Pt, 13% Rh 26 standard S24 - S Pt v Pt, 10% Rh 24 standard S25 - S Pt v Pt, 10% Rh 25 special S26 - S Pt v Pt, 10% Rh 26 standard C24 - C W, 5% Re v W, 26% Re 24 special F24 - F Platinel II 25 special Field 4. NUMBER OF ELEMENTS AND JUNCTION STYLE I - Single, butt welded, ungrounded H - Dual, butt welded, ungrounded. Return to Fields 1, 2, 3, double that price. Fields 5, 6. PROTECTION TUBE Use length determined for Fields 1, 2, 3. See compatibility table after Field 7. Size Material 12 Min. Ea. Add l 6 23-3/8 o.d. High temperature Mullite 24-11/16 o.d. High temperature Mullite 25-1 NPT High temperature Mullite 29-3/8 NPT Aluminum oxide (not available with Fields 1, 2, 3, code C24) 30-11/16 NPT Aluminum oxide 31-1 NPT Aluminum oxide 34-7 mmnpt Aluminum oxide Between 12 and 48 but not multiple of 6, use next longer length, B24H B25H B26H R24H R25H R26H S24H S25H S26H C24H F24H Page 3-14 Distributed Worldwide by www.mcgoff-bethune.com 1110-PD-001-0-00

T/C, Noble, Straight Ceramic Ordering Information (continued) See page 3-24 for protection tube/cold end termination compatibility table. Field 7. COLD END TERMINATION Single Dual 1 - General purpose, cast iron 2 - Weatherproof, cast iron 3 - General purpose, aluminum 7 - Quick disconnect plug 8 - Weatherproof, plastic 9 - Brass, open, no external process mount threads A - Weatherproof, aluminum C - Brass, open, with extrnal process mount threads D - Aluminum, transmitter ready Compatibility Table Blank cell = compatible; filled cell = not compatible Field 7 Fields 5, 6 1 2 3 7 8 9 A 23 24, 25, 30, 31 29 34 Fields 8, 9. HOT LENGTH (DIMENSION HL ) Complete these fields to determine lengths for Fields 1, 2, 3, and Fields 5, 6. HL - Enter actual inches in 6 increments. Minimum 12, maximum 48. Over 48 consult factory for availability. Field 10. RESERVED Field 11. TUBE SEAL 0 - None not available with Fields 1, 2, 3, code C24 1 - Sealed and filled with inert gas Field 12. RESERVED Field 13. MOUNTING FITTING* 0 - None (Required when Fields 5, 6 is code 01, 09, 41 or 42 1-4 Black steel sleeve 3-4 Stainless steel sleeve 4-4 Stainless steel sleeve and flange 5-4 Black steel sleeve and flange 7 - Double ended bushing P Double ended bushing, 1/2 x 3/4 NPT (Fields 5, 6, codes 23, 24, 29 and 30 only) 8 - Compression fitting (Fields 5, 6, code 34 only) 9 - Sleeve longer than 4. Specify length on order; specify code on order: Base 4 Ea. Add l 1 code 1)Black steel sleeve code 3)Stainless steel sleeve code 4)Stainless steel sleeve and flange code 5)Black steel sleeve and flange *Mounting Fitting NPT Sizes (except as noted for code P ) Field 5, 6, codes 23, 29, 34... 1/2 Field 5, 6 codes 24, 30... 3/4 Field 5, 6 codes 25, 31... 1 Fields 14, 15. RESERVED 1110-PD-001-0-00 Distributed Worldwide by www.mcgoff-bethune.com Page 3-15

T/C, Noble, Dual, Straight Thermocouple, Noble Metal Dual Tube (Ceramic in Ceramic), Straight Introduction This thermocouple is assembled with two tubes to assure element protection in the event one of the tubes cracks or breaks. Also, two tubes provide additional mechanical strength. Mullite protection tubes (Field 5, codes 23, 24) are impervious to gases at high temperature. They have good resistance to thermal shock but poor resistance to mechanical shock; they should be mounted vertically. 3/8 o.d. primary tube is inside 11/16 o.d. outer tube; 11/16 o.d. primary tube is inside 1 o.d. outer tube. Aluminum oxide protection tubes (Field 5, codes 29, 30) have fair resistance to thermal shock and mechanical shock. They are impervious to gases up to 3200 F. Applications Primary metal industry, heat treat furnaces, forging furnaces and bright annealing. Suitable for ceramics and glass industries. Salt baths in general, Barium Chloride salt baths up to 2350 F, and high speed salt baths. Semi-conductor manufacturing and research laboratories. Ordering Information Model No. - - 1 0 - - 0 0 Field No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Schedule: S3 Insulated Elements Primary Tube Secondary Tube Mounting Sleeve Adjustable Flange HL Fields 1, 2, 3. THERMOCOUPLE TYPE; WIRE GAUGE Determine length by completing Fields 8, 9 Type Wire Gauge Limits 12 Min. Ea. Add l 1 B24 - B Pt, 6% Rh v Pt, 30% Rh 24 standard B25 - B Pt, 6% Rh v Pt, 30% Rh 25 specia R24 - R Pt, 6% Rh v Pt, 30% Rh 24 standard R25 - R Pt v Pt, 13% Rh 25 special. R26 - R Pt v Pt, 13% Rh 26 standard S24 - S Pt v Pt, 10% Rh 24 standard S25 - S Pt v Pt, 10% Rh 25 special S26 - S Pt v Pt, 10% Rh 26 standard C24 - C W, 5% Re v W, 26% Re 24 special F24 - F Platinel II 25 special Field 4. NUMBER OF ELEMENTS AND JUNCTION STYLE I - Single, butt welded, ungrounded H - Dual, butt welded, ungrounded. B24I B25I R24I R25I R26I S24I S25I S26I C24I F24I B24H B25H R24H R25H R26H S24H S25H S26H C24H F24H Page 3-16 Distributed Worldwide by www.mcgoff-bethune.com 1110-PD-001-0-00

T/C, Noble, Dual, Straight Ordering Information (continued) Fields 5, 6. PROTECTION TUBES Use length determined in Fields 8, 9 Primary Tube Size Material 12 Min. Ea. Add l 6 23-3/8 High temperature Mullite* 24-11/16 High temperature Mullite* 29-3/8 Aluminum oxide 30-11/16 Aluminum oxide Price includes both primary and secondary tubes. For length between 12 and 48, but not a multiple of 6, use the price of the next longer length, plus $14.00 *Not recommended above 1800 F Field 7. COLD END TERMINATION See page 3-24 for protection tube/cold end termination compatibility table. Single 1 - General purpose, cast iron 2 - Weatherproof, cast iron 3 - General purpose, aluminum 9 - Brass, open, no external process mount threads. A - Weatherproof, aluminum C - Brass, open, with extrnal process mount threads D - Aluminum, transmitter ready Dual Fields 8, 9. HOT LENGTH (DIMENSION HL ) Complete these Fields to determine lengths for Fields 1, 2, 3 and Fields 5, 6 HL- Enter actual inches. Minimum 12, maximum 48 Over 48 consult factory for availability Field 10. RESERVED Field 11. TUBE SEAL 0 - None not available with Fields 1, 2, 3, code C24 1 - Sealed and filled with inert gas Field 12. RESERVED Field 13. MOUNTING FITTING* 0 - None (Required when Fields 5, 6 is code 01, 09, 41 or 42) 1-4 Black steel sleeve 3-4 Stainless steel sleeve 4-4 Stainless steel sleeve and flange 5-4 Black steel sleeve and flange 7 - Double ended bushing P Double ended bushing, 1/2 x 3/4 (Fields 5, 6, codes 23 and 29 only).. 9 - Sleeve longer than 4. Specify length on order; specify code on order: Base 4 Ea. Add l 1 code 1) Black steel sleeve code 3) Stainless steel sleeve code 4) Stainless steel sleeve and flange code 5) Black steel sleeve and flange *Mounting Fitting NPT Sizes (except as noted for code P ) Tube codes 23, 29, 34... 1/2 Tube codes 24, 30... 3/4 Tube codes 25, 31... 1 Fields 14, 15. RESERVED 1110-PD-001-0-00 Distributed Worldwide by www.mcgoff-bethune.com Page 3-17

T/C, Noble, Dual, Straight Thermocouple, Noble Metal Dual Tube (Ceramic in Inconel 601), Straight Introduction Applications Elements are made of top quality material. Insulators are 99.7% Al 2 O 3 (high purity). Primary protection tube is ether high temperature Mullite or aluminum oxide. The secondary protection tube is Inconel 601 which has a high resistance to thermal and mechanical shock up to 2300 F. The Inconel 601 protection tube has excellent resistance to oxidation up to 2300 F and to corrosion at high temperature. Hydrogen makes it brittle. 3/8 o.d. primary tube is inside an 0.8450 o.d. pipe; 11/16 o.d. tube is inside a 1.050 o.d. pipe. For use in furnaces, kilns, and other locations where the protection tube is subject to either mechanical or thermal shock. Suitable for high temperature heat treating, carburizing, nitriding, salt baths, blast furnace operation, gas generators, and ceramic kilns. Ordering Information Model No. - - 6 0 - - Field No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Schedule: S3 U 1-1/2" Nominal Insulated Elements Primary Tube Secondary Tube (Inconel) HL 3/4" Ref Fields 1, 2, 3. THERMOCOUPLE TYPE; WIRE GAUGE Determine length by completing Fields 8, 9 Type Wire Gauge Limits 12 Min. Ea. Add l 1 B24 - B Pt, 6% Rh v Pt, 30% Rh 24 standard B25 - B Pt, 6% Rh v Pt, 30% Rh 25 special R24 - R Pt, 6% Rh v Pt, 30% Rh 24 standard R25 - R Pt v Pt, 13% Rh 25 special R26 - R Pt v Pt, 13% Rh 26 standard S24 - S Pt v Pt, 10% Rh 24 standard S25 - S Pt v Pt, 10% Rh 25 special S26 - S Pt v Pt, 10% Rh 26 standard C24 - C W, 5% Re v W, 26% Re 24 special F24 - F Platinel II 25 special Field 4. NUMBER OF ELEMENTS AND JUNCTION STYLE I - Single, butt welded, ungrounded H - Dual, butt welded, ungrounded. Return to Fields 1, 2, 3, double that price. Fields 5, 6. PROTECTION TUBES Use length determined in Fields 8, 9 Primary Tube Size Material 12 Min. Ea. Add l 6 23-3/8 High temperature Mullite 24-11/16 High temperature Mullite 29-3/8 Aluminum oxide 30-11/16 Aluminum oxide Note: Prices include both primary and secondary tubes. For length between 12 and 48, but not a multiple of 6, use the price of the next longer length, B24I B25I R24I R25I R26I S24I S25I S26I C24I F24I B24H B25H R24H R25H R26H S24H S25H S26H C24H F24H Page 3-18 Distributed Worldwide by www.mcgoff-bethune.com 1110-PD-001-0-00

T/C, Noble, Dual, Straight Ordering Information (continued) Field 7. COLD END TERMINATION See page 3-24 for protection tube/cold end termination compatibility table. Single 1 - General purpose, cast iron 2 - Weatherproof, cast iron 3 - General purpose, aluminum 9 - Brass, open, no external process mount threads A - Weatherproof, aluminum B - Explosionproof, cast iron C - Brass, open, with extrnal process mount threads D - Aluminum, transmitter ready E - Explosionproof, aluminum (extended lead time) Fields 8, 9. HOT LENGTH (DIMENSION HL ) Complete these Fields to determine lengths for Fields 1, 2, 3 and Fields 5, 6 HL - Enter actual inches. Minimum 12, maximum 48 Over 48 consult factory When U dimension (Fields 14, 15) is specified, allow for 1-1/2 nominal bushing length Dual Field 10. RESERVED Field 11. TUBE SEAL 0 - None 1 - Sealed and filled with inert gas Field 12. RESERVED Field 13. MOUNTING FITTING 0 - None 2 - Adjustable mounting flange F - Welded bushing, 3/4 NPT, SS (Fields 5, 6, codes 23 and 29 only) G - Welded bushing, 1 NPT, SS (Fields 5, 6, codes 24 and 30 only) Fields 14, 15. MOUNTING FITTING LOCATION ( U DIMENSION) Applicable only if Field 13 is code F or G. 00 - Not applicable UU - Whole inches 99 - Fractional inches, specify on order 1110-PD-001-0-00 Distributed Worldwide by www.mcgoff-bethune.com Page 3-19

Introduction T/C, Noble, Dual or Triple, Straight Thermocouple, Noble Metal Dual or Triple Tube (Ceramic in Silicon Carbide), Straight Applications The design of this assembly is for the maximum protection of the noble metal element. The primary protection tube (or tubes) protects the element from outside gases while the outer tube of silicon carbide protects the assembly against the cutting action of flames and hot gases. You can choose either high temperature Mullite or aluminum oxide for the primary tube material. High temperature Mullite is not recommended for temperatures above 1800 F. Silicon carbide protection tubes have low lag time and long life; high resistance to thermal shock, high conductivity, and impermeability. They are especially resistant to many corrosive atmospheres and are highly resistant to attack by many molten nonferrous metals. For use with molten nonferrous metals, brick kilns, ceramic kilns and where the thermocouple is exposed to either flames or hot gases. Ordering Information Model No. - - 0 - - 0 0 Field No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Schedule: S3 HL Fields 1, 2, 3. THERMOCOUPLE TYPE; WIRE GAUGE Determine length by completing Fields 8, 9 Type Wire Gauge Limits 12 Min. Ea. Add l 1 B24 - B Pt, 6% Rh v Pt, 30% Rh 24 standard 4-1/2" Diameter B25 - B Pt, 6% Rh v Pt, 30% Rh 25 special Flange (optional) B26 - B Pt, 6% Rh v Pt, 30% Rh 26 standard R24 - R Pt, 6% Rh v Pt, 30% Rh 24 standard R25 - R Pt v Pt, 13% Rh 25 special R26 - R Pt v Pt, 13% Rh 26 standard S24 - S Pt v Pt, 10% Rh 24 standard S25 - S Pt v Pt, 10% Rh 25 special S26 - S Pt v Pt, 10% Rh 26 standard C24 - C W, 5% Re v W, 26% Re 24 special F24 - F Platinel II 25 special 2-1/2" Dia. Field 4. NUMBER OF ELEMENTS AND JUNCTION STYLE 6-1/2" I - Single, butt welded, ungrounded Approximately H - Dual, butt welded, ungrounded. Return to Fields 1, 2, 3, double that price. B24I B25I R24I R25I R26I S24I S25I S26I C24I F24I B24H B25H R24H R25H R26H S24H S25H S26H C24H F24H Page 3-20 Distributed Worldwide by www.mcgoff-bethune.com 1110-PD-001-0-00

T/C, Noble, Dual or Triple, Straight Ordering Information (continued) Fields 5, 6. PROTECTION TUBES Use length determined in Fields 8, 9 Size Material 12 Min. Ea. Add l 6 Dual Tube Assemblies (Primary tube is 11/16 ) 24-11/16 High temperature Mullite 30-11/16 Aluminum oxide Triple Tube Assemblies (Primary tube is 3/8 ; middle tube is 11/16 ) 23-3/8 High temperature Mullite 29-3/8 Aluminum oxide Note: Price includes all tubes. Field 7. COLD END TERMINATION See page 3-24 for protection tube/cold end termination compatibility table. Single 1 - General purpose, cast iron 2 - Weatherproof, cast iron 3 - General purpose, aluminum 9 - Brass, open, no external process mount threads A - Weatherproof, aluminum C - Brass, open, with extrnal process mount threads D - Aluminum, transmitter ready Dual Fields 8, 9. HOT LENGTH (DIMENSION HL ) Complete these Fields to determine lengths for Fields 1, 2, 3 and Fields 5, 6 HL - Enter actual inches in 6 increments. Minimum 12, maximum 48 Over 48 consult factory for availability. Field 10. OUTER TUBE Priced in Fields 5, 6 2 - Dual tube assembly, silicone carbide outer tube 3 - Triple tube assembly, silicone carbide outer tube Field 11. TUBE SEAL 0 - None 1 - Sealed and filled with inert gas Field 12. RESERVED Field 13. MOUNTING FITTING 0 - None 2 - Adjustable mounting flange Fields 14, 15. RESERVED 1110-PD-001-0-00 Distributed Worldwide by www.mcgoff-bethune.com Page 3-21