NFPA 285 Compliant Wall Assemblies with Perm-A-Barrier Air Barriers Walls Containing Mineral Wool Insulation

Similar documents
NFPA 285 Assemblies. Table of Contents

NFPA 285 Assemblies. Table of Contents

Henry NFPA 285 Air Barrier Assemblies

Deer Ridge Consulting, Inc.

Exterior Wall Analysis Use of Gypsum Sheathing Over XPS Insulation in NFPA 285 Complying Wall Assemblies JENSEN HUGHES Project No. 1JJB05306.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

RE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying Wall Assemblies No. 1JJB05306.

NFPA 285 Compliant Wall Systems and Assemblies

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

October 15, Dow Building Solutions The Dow Chemical Company 1605 Joseph Drive Midland, MI 48642

CommercialComplete Wall System

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

ENGINEERING EVALUATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC. EVALUATION SUBJECT:

December 8, Dow Building Solutions The Dow Chemical Company 1605 Joseph Drive Midland, MI 48642

ICC-ES Evaluation Report. ESR-3398* Reissued October 2013 This report is subject to renewal November 1, 2015.

O82018 Hunter Panels XCI Foil

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

NFPA 285 Wall Assemblies

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

Code Compliance Research Report CCRR-1043

SECTION CONTINUOUS INSULATION XCI CG WALL PANELS

SECTION CONTINUOUS INSULATION XCI 286 WALL/CEILING PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER:

SECTION CONTINUOUS INSULATION XCI FOIL (CLASS A) WALL PANELS

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

UL Evaluation Report UL ER Issued: October 30, Revised: September 12, UL Category Code: ULEX.

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Technical Data Sheet

ENGINEERING EVALUATION

Originally Issued: 07/31/2015 Revised: 07/31/2017 Valid Through: 07/31/ General

Originally Issued: 07/06/2009 Revised: 04/07/2017 Valid Through: 07/31/2017

ENGINEERING EVALUATION

ENGINEERING EVALUATION

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BAYER MATERIALSCIENCE, LLC

Intertek Research Report IRR-1011

NFPA 285 Tested Wall Assemblies Using

Ultra Wall System. CAD Detail Sets

NFPA 285: Assembly Test of Exterior Walls with Combustible Components. Herman Lopez DuPont Commercial Account Manager

ProGUARD Guide Specification

SCIENCE. SERVICE. SOLUTIONS. AIR & VAPOR BARRIER. Fire Resist Product Line

NFPA 285 Tested Wall Assemblies Using

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: JOHNS MANVILLE

WEIGHT PER PIECE (LBS.)

ProGUARD DP The Game-changing Wall System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

ICC-ES Evaluation Report. ESR-1154 Reissued July 1, 2012 This report is subject to renewal September 1, 2014.

Impact of NFPA 285 on Air Barrier Specification and Design

PERM-A-BARRIER NPS Detail Membrane

R-Value and Densities Chart

2013 COMMERCIAL PRODUCTS

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Detail Set: Thermax Wall System Masonry

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Engineering Analysis of NFPA 285 Tested Assemblies

August 28, Mr. Jason Roy Plant Manager Advanced Building Products, Inc. 95 Cyro Drive Sanford, ME 04073

Continuous Insulation and Air Barriers for High Performance Walls

SECTION THERMAL INSULATION

Originally Issued: 07/2009 Revised: 09/30/2014 Valid Through: 07/2015

Session: Foam Plastic Insulation Exterior Wall Fire Safety

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

SECTION (07200) - THERMAL PROTECTION

Compliance for Continuous Insulation, Water Resistive Barriers & NFPA-285 What you need to Know

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

NFPA 285 Wall System Compliance Directory

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

Construction Standards PAGE

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

Perm-A-Barrier NPS (Non Permeable Sheet)

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

TL-0012 Use on Oriented Strand Board (OSB) Roof Sheathing Technical Letter

Continuous Insulation: Code Compliance and the NFPA 285 in Commercial Wall Assemblies. Hunter Panels Provider No. K169 Course Number HP 105

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

7/25/2011. THERMAL BARRlERS AND IGNITION BARRIERS. What is a Thermal Barrier? Thermal Barrier Code

R-Matte Plus-3: Insulation for the Building Envelope

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

Transcription:

PRODUCT DATA SHEET NFPA 285 Compliant Wall Assemblies with Perm-A-Barrier Air Barriers Walls Containing Mineral Wool Insulation 1. Concrete wall 2. Concrete Masonry wall 3. Standard Clay Brick Wall Base wall system Use either 1, 2, 3, 4 or 5 4. Adobe Block Wall 5. 1 layer 5/8-inch thick, Type X, Gypsum wallboard on interior, installed over steel studs: minimum 35/8-inch depth, minimum 20-gauge at a maximum of 16-inch OC with lateral bracing every 4 ft. vertically Cavity Insulation Use either 1, 2 or 3 2. Fiberglass batt insulation (faced or unfaced) 3. Any noncombustible insulation Exterior sheathing Use either 1, 2 or 3 2. 1/2-inch thick, exterior type gypsum sheathing 3. 5/8-inch thick, Type X, exterior type gypsum sheathing 1. Perm-A-Barrier Liquid 2. Perm-A-Barrier NPL 3. Perm-A-Barrier NPL 10 Air and water barrier applied to gypsum sheathing Use either 1, 2, 3, 4,5, 6, 7, 8, 9 or 10 4. Perm-A-Barrier VPO 5. Perm-A-Barrier VPL 6. Perm-A-Barrier VPL LT 7. Perm-A-Barrier Wall Membrane 8. Perm-A-Barrier Aluminum Wall Membrane 9. Perm-A-Barrier VPS 10. Perm-A-Barrier NPS 11. Perm-A Barrier VPL 50 Mineral wool (2 min. thick, unfaced, mechanically attached and meets ASTM C612). Exterior insulation Exterior Veneer Use either 1 or 2 1. The mineral wool shall not have any type of facer on either side. 2. The mineral wool shall be noncombustible via ASTM E 136 testing. The density of the mineral wool shall range from 4.0 to 9.0 lbs/ft3. The R-value/inch of the mineral wool shall range from 3.5 to 4.5. 3. The mineral wool insulation must be mechanically attached. 4. The mineral wool must completely cover the air barrier. 1. Any noncombustible exterior veneer with or without air gap between exterior insulation and exterior veneer 2. Any combustible exterior veneer, that has been successfully tested by the panel manufacturer via NFPA 285 test method, with or without air gap between exterior insulation and exterior veneer. Installed using standard installation techniques. Evidence of testing in accordance with NFPA 285 and/or an ICC-ES report must be submitted to the code official. Version 10.27.16 1

Walls Containing XPS Insulation Base wall system Use either 1, 2, or 3 Floorline Firestopping Cavity Insulation Use either 1, 2 or 3 Exterior sheathing Use either 1, 2 or 3 Air and water barrier applied to gypsum sheathing Use either 1, 2, 3, 4,5, 6 or 7 Exterior insulation Exterior Veneer Use either 1,2,3,4 or 5 Flashing of window, door and other exterior wall penetrations Use either 1 or 2 1. Concrete wall 2. Concrete Masonry wall 3. 1 layer 5/8-inch thick, Type X, Gypsum wallboard on interior, installed over steel studs: minimum 35/8-inch depth, minimum 20-gauge at a maximum of 16-inch OC with lateral bracing every 4 ft. vertically 4 lb/ft3 mineral wool in each stud cavity at each floorline at- tached with Z-clips or equivalent 2. Fiberglass batt insulation (faced or unfaced) 3. Any noncombustible insulation 2. 1/2-inch thick, exterior type gypsum sheathing 3. 5/8-inch thick, Type X, exterior type gypsum sheathing 1. Perm-A-Barrier NPL 2. Perm-A-Barrier NPL 10 3. Perm-A-Barrier VPL 4. Perm-A-Barrier VPL LT 5. Perm-A-Barrier NPS 6. Perm-A-Barrier Aluminum Wall Membrane 7. Perm-A-Barrier VPS Extruded Polystyrene Foam Insulation (XPS) Type IV per ASTM C578 Total thickness to be a minimum of 1/2 inch to maximum of 3 inches. On insulation joints, 4 Perm-A-Barrier Detail Membrane or Perm-A-Barrier Aluminum Flashing can be used. 1. Brick - Standard nominal 4-inch thick, clay brick. Brick installed with standard type veneer anchors at maximum 24 inches OC vertically on each stud. Maximum 2-inch air gap between exterior insulation and brick 2. Concrete 2 inches thick or greater. Maximum 2-inch air gap between exterior insulation and concrete. 3. Concrete masonry units 4 inches thick or greater. Maximum 2-inch air gap between exterior insulation and CMU. 4. Stone veneer Minimum 2-inch thick, Limestone or natural stone veneer or minimum 1-1/2 inch thick cast artificial stone veneer. Any standard non-open-joint installation technique such as ship-lap, etc. can be used. 5. Terracotta cladding Use any terracotta cladding system in which terracotta is minimum 1-1/4 inch thick. Any non- open-joint installation technique such as ship-lap, etc. can be used. 1. Perm-A-Barrier Detail Membrane 2. Perm-A-Barrier Aluminum Flashing Version 10.27.16 2

Version 10.27.16 3

Walls Containing XPS Insulation Version Choose 10.27.16 window / door header design 1, 2 or 3 for NFPA 285 compliance. 4

Walls Containing XPS Insulation Choose window / door header design 1, 2 or 3 for NFPA 285 compliance. Source: Jensen Hughes Version 10.27.16 5

Walls Containing one or more of the following Dow Chemical Products: Thermax Brand Rigid Insulation; STYROFOAM Brand Spray Polyurethane Foam CM 2030, STYROFOAM Brand Spray Polyurethane Foam CM 2045 or STYROFOAM Brand Spray Polyurethane Foam CM 2060. These Products are closed cell, nominal 2.0 lb/ft3 density, spray polyurethane foam plastic insulation. For Maximum 4.25-Inch-Thick Thermax Insulation Board Base wall system Use either 1, 2, 3, 4 or 5 Floorline Firestopping Cavity Insulation Use either 1, 2 or 3 or combination of 2 & 3 Exterior sheathing Use either 1, 2 or 3 1. Concrete wall 2. Concrete Masonry wall 3. Standard clay brick wall 4. Adobe block wall 5. Steel stud (minimum 35/8 deep, minimum 20-gauge, maximum 24-inch OC, lateral bracing every 4 ft. verti- cally) with one of the following installed on the interior face side of the stud wall: a. 1 layer 5/8-inch thick Type X or 1/2-inch thick Type X Gypsum wallboard on interior face of studs, or b. GCP Monokote Z-3306, 3/8 thick minimum, installed over: I. cavity insulation Item 2 or II. Thermax c. International Cellulose Corporation s Ure-K Thermal Barrier System 1.25 inches minimum installed over: i. Cavity Insulation Item 2 or; ii Dow Thermax, any thickness d. Flame Seal Products, Inc. Flame Seal-TB coating applied at 25 mils wet thickness (18 mils dry, 65 ft2/ gal) over cavity insulation Item 2 e. International Fireproof Technology, Inc. DC 315 applied at 18 wet mils thickness over 4 dry mils of primer over cavity insulation Item 2 4 lb/ft3 mineral wool in each stud cavity at each floorline attached with Z-clips or equivalent (see Figure 1) 2. Full stud depth or less thickness of DOW STYROFOAM Spray Polyurethane CM 2030 or CM 2045 or CM 2060. Use exterior sheathing as substrate to apply onto and cover the width of the cavity including inside the stud flange 3. Fiberglass batt insulation (faced or unfaced) 2. 1/2-inch thick, exterior type gypsum sheathing complying with the applicable code 3. 5/8-inch thick, exterior type gypsum sheathing complying with the applicable code Version 10.27.16 6

For Maximum 4.25-Inch-Thick Thermax Insulation Board (continued) Weather-resistive barrier applied to exterior sheathing Use either 1, 2, 3, 4,5, 6 or 7 Exterior insulation Use either 1, 2, 3 or 4 Weather-resistive barrier applied to exterior insulation Use 1, 2 or 3 Flashing / Flash all exterior insulation joints and veneer tie penetration with one of the following: Exterior Veneer Use 1, 2, 3, 4, 5 or 6 2. Perm-A-Barrier NPL 3. Perm-A-Barrier VPL 4. Perm-A-Barrier VPL LT 5. Perm-A-Barrier Aluminum Wall Membrane 6. Perm-A-Barrier VPS 7. Perm-A-Barrier NPS. Exterior sheathing must be Item 2 or 3 as specified under exterior sheathings above 2. Dow Thermax Insulation Board (Thickness: 5/8-inch minimum, 4.25-inch maximum) 3. DOW STYROFOAM Spray Polyurethane CM 2030, CM 2045 or CM 2060 (Thickness: 3.5-inch maximum) 4. Combination of 2 (Thermax Insulation Board) and 3 (STYROFOAM Spray Polyurethane CM 2030, CM 2045 or CM 2060). The combined thickness of 2 and 3 do not exceed 4.25-inches (item 3 not exceeding 3.5 inches) 2. WeatherMate Dow Chemical 3. WeatherMate Plus Dow Chemical 1. Brick. Use standard nominal 4-inch thick, day brick. Use standard brick veneer anchors installed vertically on each stud at maximum of 24-inch o.c. creating a 2-inch maximum air gap between the exterior insulation and brick. 2. Stucco. Minimum 3/4-inch thick, exterior cement plaster and lath. An optional secondary water-resistive barrier can be installed between the exterior insulation and the lath. The secondary water-resistive barrier must not be full-coverage asphalt or butyl-based self-adhered membranes. 3. Limestone. Minimum 2-inch thick installed using any standard non-open joint-installation technique such as ship-lap. 4. Natural Stone Veneer. Minimum 2-inch thick installed using any standard non-open-joint installation technique such as ship-lap. 5. Concrete or precast concrete panel-minimum 1.5 inch thick panel, with a 2 inch maximum air gap between exterior insulation and concrete panel. Any standard non-open joint installation technique such as ship-lap, etc. can be used. 6. Terracotta cladding. Minimum 11/4-inch thick installed using any standard non-open-joint installation technique such as ship-lap. Version 10.27.16 7

For Maximum 3-Inch-Thick Thermax Insulation Board Base wall system Use either 1, 2, 3, 4 or 5 Floorline Firestopping Cavity Insulation Use either 1, 2 or 3 or combination of 2 & 3 Exterior sheathing Use either 1, 2 or 3 Weather-resistive barrier applied to exterior sheathing Use either 1, 2, 3, 4, 5 or 6 Exterior insulation Use either 1 or 2 1. Concrete wall 2. Concrete Masonry wall 3. Standard clay brick wall 4. Adobe block wall 5. Steel studs: minimum 35/8-inch depth, minimum 20-gauge at a maximum of 24-inch OC with lateral bracing every 4 ft. vertically with: a. 1 layer 5/8-inch thick Type X or 1/2-inch thick Type X Gypsum wallboard on interior face of studs, or b. GCP Monokote Z-3306 installed at a minimum of 3/8 inch thickness over cavity insulation (Item 2) or Thermax, or c. International Cellulose Corporation s Ure-K Thermal Barrier System installed at a minimum of 1.25 inch thickness over cavity insulation (Item 2) or Thermax. d. Flame Seal Products, Inc. Flame Seal-TB coating applied at a wet mil thickness of 25 mils (18 mils dry, 65 ft2/gal) over cavity insulation (Item 2) e. International Fireproof Technology, Inc. DC 315 applied at an application rate of 18 wet mils applied over 4 mils of primer which is applied over cavity insulation (Item 2) 4 lb/ft3 mineral wool in each stud cavity at each floorline attached with Z-clips or equivalent (see Figure 1) 2. Full stud depth or less thickness of DOW STYROFOAM Brand Spray Polyurethane CM 2030 or CM 2045 or CM 2060. Use exterior sheathing as substrate to apply onto and cover the width of the cavity including inside the stud flange 3. Fiberglass batt insulation (faced or unfaced) 2. 1/2-inch thick, exterior type gypsum sheathing complying with the applicable code 3. 5/8-inch thick, exterior type gypsum sheathing complying with the applicable code 2. Perm-A-Barrier NPL 3. Perm-A-Barrier VPL 3. Perm-A-Barrier VPL LT 4. Perm-A-Barrier Aluminum Wall Membrane 5. Perm-A-Barrier VPS 5. Perm-A-Barrier NPS. Exterior sheathing must be Item 2 or 3 as specified under exterior sheathings above 2. Dow Thermax Insulation Board (Thickness: 5/8-inch minimum, 3-inch maximum) Version 10.27.16 8

For Maximum 3-Inch-Thick Thermax Insulation Board (continued) Flashing Exterior Veneer Use 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 or 13 Flash all exterior insulation joints and veneer tie penetrations with one of the following: 1. Dow WeatherMate Flashing max. 4-inch width. 2. Asphalt or Butyl-based flashing tape max. 4-inch width. Optional: Spray primer to aid in adhesion of either 1 or 2 applied at a maximum of 5-inches wide. 1. Metal Composite Material System. Use any Metal Composite Material System that has been successfully tested by the panel manufacturer via NFPA 285 test method. Installed using standard installation techniques. Evidence of testing in accordance with NFPA 285 and/or an ICC-ES report must be submitted to the code official. 2. Terracotta cladding. Minimum 11/4-inch thick installed using any standard installation techniques. 3. Metal Exterior Wall Coverings. Including but not limited to steel, aluminum and copper installed using standard installation techniques. 4. Cement board Siding. Any standard installation technique can be used. 5. StoneLite wall panels by Stone Panels. 6. Brick - Standard nominal 4-inch thick, clay brick with brick veneer anchors standard types installed maximum 24 inches OC vertically on each stud. Maximum 2-inch air gap between exterior insulation and brick. 7. Stucco Minimum 3/4-inch thick, exterior cement plaster and lath. A secondary water-resistive barrier can be installed between the Exterior insulation and the lath. The secondary water-resistive barrier shall not be full-coverage asphalt or butyl-based self-adhered membranes. 8. Corium Thin brick system. 9. Minimum 11/4-inch thick, Limestone or natural stone veneer or minimum 11/4 inch thick cast artificial stone veneer. Any standard installation technique such as ship-lap, etc. can be used. 10. Glen-Gery Thin Tech Elite Series Masonry veneer. 11. Concrete or precast concrete panels Minimum 1.5-inch thick panel, with a 2-inch maximum air gap between exterior insulation and concrete panel. Any standard installation technique can be used. 12. Ceramic tile (min. 3/8-in. thick) bonded using non- combustible mortar adhesive to minimum 1/2-in. thick cement board or gypsum sheathing. 13. Knight Wall Systems to include Metal Panel (Aluminum or steel), Thin Brick Panels, NuTech AFC Stucco applied to Permabase cement board, Terracotta Single skin or double skin 15 mm or thicker, Concrete panels, Corium Thin Brick system. Version 10.27.16 9

For Firestone Enverge CI Foil Exterior Wall Insulation or Enverge CI Glass Exterior Wall Insulation Base wall system Use either 1, 2 or 3 Floorline Firestopping Cavity Insulation Use either 1, 2, or 3 Exterior sheathing Use either 1, 2 or 3 Water-resistive barrier applied to exterior sheathing - Use 1, 2, 3, 4, 5 or 6 Exterior insulation Use either 1 or 2 Flashing Use either None, 1 or 2 Weather-resistive barrier applied to exterior insulation 1. Concrete wall 2. Concrete Masonry wall 3. 1 layer 5/8-inch thick Type X Gypsum wallboard on interior, installed over steel studs: minimum 35/8-inch depth, minimum 20-gauge at a maximum of 24-inch OC with lateral bracing every 4 ft. vertically 4 lb/ cu ft3 mineral wool (e.g. Thermafiber) in each stud cavity at each floorline attached with Z-clips or equivalent 2. Any noncombustible insulation 3. Fiberglass batt insulation (faced or unfaced) 2. 1/2-inch thick, exterior type gypsum sheathing 3. 5/8-inch thick, exterior type gypsum sheathing 1 - Perm-A-Barrier Aluminum Wall Membrane 2 - Perm-A-Barrier VPL 3 - Perm-A-Barrier VPL LT 4 - Perm-A-Barrier VPS 5 - Perm-A-Barrier NPL 6 - Perm-A-Barrier NPS 1. Firestone Enverge CI Foil Exterior Wall Insulation 21/2-inch maximum thickness with Exterior Veneer Part 1 or 4-inch maximum thickness with Exterior Veneer Part 2 2. Firestone Enverge CI Glass Exterior Wall Insulation 21/2-inch maximum thickness with Exterior Veneer Part 1 or 4-inch maximum thickness with Exterior Veneer Part 2 Optional - Flash all exterior insulation joints and veneer tie penetrations with: 1. 4-inch wide Shuretape AF 100 or AF 975CT aluminum foil none Version 10.27.16 10

For Firestone Enverge CI Foil Exterior Wall Insulation or Enverge CI Glass Exterior Wall Insulation (continued) Exterior Veneer Part 1 - Use either 1, 2, 3, 4, 5, 6, 7 or 8 Exterior Veneer Part 2 - Use either 1, 2, 3 or 4 1. Brick a. Brick veneer anchors standard types installed maximum 24 inches OC vertically on each stud. b. Maximum 2-inch air gap between exterior insulation and brick Standard nominal 4-inch thick, clay brick. 2. Stucco Minimum 3/4-inch thick, exterior cement plaster and lath. A secondary water-resistive barrier can be installed between the exterior insulation and the lath. The secondary water-resistive barrier shall not be full-coverage asphalt or butyl-based self-adhered membranes. 3. Minimum 2-inch thick, Limestone or natural stone veneer or minimum 11/2-inch thick cast artificial stone veneer. Any standard installation technique can be used. 4. Terracotta cladding Use any terracotta cladding system in which terracotta is minimum 11/4-inch thick. Any standard installation technique can be used. 5. Metal veneer such as steel, aluminum, copper, etc. Any standard installation technique can be used. 6. Cement board siding Any standard installation technique can be used. 7. MCM System Use any Metal Composite Panel that has been successfully tested by the panel manufacturer via NFPA 285 test method. Installation shall be such that the free air cavity behind the MCM shall not exceed 27/8 inches. 8. Aluminum faced, aluminum honeycomb core panels. Any standard installation technique can be used. 1. Brick c. Brick veneer anchors standard types installed maximum 24 inches OC vertically on each stud. d. Maximum 2-inch air gap between exterior insulation and brick Standard nominal 4-inch thick, clay brick. 2. Stucco Minimum 3/4-inch thick, exterior cement plaster and lath. A secondary water-resistive barrier can be installed between the exterior insulation and the lath. The secondary water-resistive barrier shall not be full-coverage asphalt or butyl-based self-adhered membranes. 3. Minimum 2-inch thick, Limestone or natural stone veneer or minimum 11/2-inch thick cast artificial stone veneer. Any standard non-open-joint installation technique such as ship-lap, etc. can be used. 4. Terracotta cladding Use any terracotta cladding system in which terracotta is minimum 11/4-inch thick. Any standard non-open-joint installation technique such as ship-lap, etc. can be used. Version 10.27.16 11

For Exterior Walls where the Air Barrier is the only Combustible Component Per 2015 IBC section 1403.5 (exemption 1) Base wall system Use either 1, 2, 3, 4, or 5 Cavity Insulation Use either 1, 2, or 3 Exterior sheathing Use either 1, 2 or 3 Air and water barrier applied to gypsum sheathing Use either 1, 2, 3, 4, 5 or 6 Exterior insulation Exterior Veneer Use either 1, 2, 3, 4, 5, or 6 1. Concrete wall 2. Concrete Masonry wall 3. Standard Clay Brick Wall 4. Adobe Block Wall 5. 1 layer 5/8-inch thick, Type X, Gypsum walboard on interior, installed over steel studs: minimum 35/8-inch depth, minimum 20-guage at a maximum of 16-inch OC with lateral bracing every 4 ft. vertically. 2. Fiberglass batt insulation (faced or unfaced) 3. Any noncombustible insulation 2. 1/2-inch thick, exterior type gypsum sheathing 3. 5/8-inch thick, Type X, exterior type gypsum sheathing 1. Perm-A-Barrier NPL 2. Perm-A-Barrier NPL 10 3. Perm-A-Barrier Aluminum Wall Membrane 4. Perm-A-Barrier VPL 5. Perm-A-Barrier VPS 6. Perm-A-Barrier NPS none 1. Brick Standard nominal 4-inch thick, clay brick. Brick installed with standard type veneer anchors at maximum 24 inches OC vertically on each stud. Maximum 2-inch air gap between exterior insulation and brick. 2. Concrete 2 inches thick or greater. Maximum 2-inch air gap between exterior insulation and concrete. 3. Concrete masonry units 4 inches thick or greater Maximum 2-inch air gap between exterior insulation and CMU. 4. Stone veneer Minimum 2-inch thick, Limestone or natural stone veneer or minimum 1-1/2 inch thick cast artificial stone veneer. Any standard non-open-joint installation technique such as ship-lap, etc. can be used. 5. Terracotta cladding Use any terracotta cladding system in which terracotta is minimum 1-1/4 inch thick. Any non-open-joint installation technique such as ship-lap, etc. can be used. 6. Steel exterior wall coverings, (approved corrosion resistant, minimum 0.0149). Version 10.27.16 12

For walls containing Atlas Energy Shield Pro or Pro2 Exterior Insulation (Technical Evaluation Report No. 1306-3, DrJ) Base wall system Use either 1, 2 or 3 Floorline Firestopping Use 1 or 2 Cavity Insulation Use either 1, 2, 3, 4, 5, 6, 7, 8, or 9 Note: Cavity Insulations 5-9 must use Floorline Firestopping Item 2 and 5/8 exterior gypsum sheathing. Exterior Sheathing Use either 1, 2 or 3 Air Barrier or Weather-Resistive Barrier Applied to Exterior Sheathing Use 1, 2, 3, 4, 5, 6 or 7 Exterior Insulation Use either 1, 2, 3, or 4 1. 1 minimum Concrete Wall 2. 1 minimum Concrete Masonry Wall 3. 20-gauge (min.) 35/8 (min.) steel studs spaced at a maximum of 24 o.c. a. 1 layer 5/8 -thick Type X gypsum wallboard on interior 2. 4 lb./cu ft. mineral wool (e.g., Thermafiber) in each stud cavity at each floor line attached with Z-clips or equivalent 2. Any noncombustible insulation per ASTM E136 3. Any mineral fiber (Board type Class A ASTM E84 faced or unfaced) 4. Fiberglass (Batt type Class A ASTM E84 faced or unfaced) 5. 51/2 (max.) Icynene LD-C-50 spray foam in 6 deep studs (max.) full fill without an air gap 6. 51/2 (max.) Icynene MD-C-200, 2 pcf spray foam in 6 deep studs (max.) full fill without an air gap 7. 51/2 (max.) Icynene LD-R-201, 2 pcf spray foam in 6 deep studs (max.) full fill without an air gap 8. 6 (max.) SWD Urethane QS 112, 2 pcf spray foam in 6 deep studs (max.) or partial fill with a maximum 21/2 air gap 9. 31/2 (max.) Gaco Western 183M spray foam in 35/8 deep studs (max.) 1. 1/2 or thicker exterior type gypsum sheathing 2. None, when utilizing exterior cladding of brick or equivalent (cladding options 1-6) 3. 2 precast concrete panels attached to structural elements of building 1. Perm-A-Barrier PAB VPL LT 2. Perm-A-Barrier NPL 10 3. Perm-A-Barrier NPL 4. Perm-A-Barrier VPS 5. Perm-A-Barrier VPL 6. Perm-A-Barrier AWM 7. Perm-A-Barrier NPS 2. 2 or 3 Atlas EnergyShield Pro (or Pro2), and 4 EnergyShield Pro (or Pro2) may be substituted for each other in reports that utilize either of these insulations 3. 4 Rboard Pro 4. Any exterior insulation that has been tested per ASTM E1354 (at a minimum of 20 kw/m2 heat flux) and shown by analysis to be less flammable (improved Tign, Pk.HRR) than those listed above Version 10.27.16 13

For walls containing Atlas Energy Shield Pro or Pro2 Exterior Insulation Exterior Cladding Use any of these options 1. Brick a. Brick veneer anchors standard types installed maximum 24 o.c. (max.) vertically on each stud b. Maximum 2 air gap between exterior insulation and brick c. Standard nominal 4 -thick clay brick or veneer 2. Stucco Minimum 7/8 -thick, exterior cement plaster and lath. A secondary WRB can be installed between the exterior insulation and the lath. The secondary WRB shall not be full-coverage asphalt or butyl-based self-adhered membranes. 3. Limestone minimum 2 thick 4. Natural stone veneer minimum 2 thick 5. Cast artificial stone minimum 1.5 thick complying with ICC-ES AC 51 6. Terracotta Cladding Use any terracotta cladding system in which terracotta is minimum 11/4 thick. Any standard installation technique can be used. 7. Any ACM that has passed NFPA 285 8. Uninsulated sheet metal building panels including aluminum, steel or copper 9. Uninsulated cement or fiber-cement cladding panels 10. Stone/Altuminum honeycomb composite building panels that have successfully passed NFPA 285 criteria 11. Autoclaved-aerated-concrete (AAC) panels (minimum 11/2 thick) 12. Reynobond ZCM Zinc metal composite panel Check the insulation manufacturers recommendations for window and door opening details. Perm-A-Barrier NPS Perm-A-Barrier Aluminum Wall Membrane Perm-A-Barrier VPL gcpat.com Customer Service: 1-866-333-3726 We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right. Perm-A-Barrier and Bituthene are trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status. DensGlass Gold is a registered trademark of Georgia-Pacific Corporation. Copyright 2016 GCP Applied Technologies Inc. All rights reserved. GCP Applied Technologies Inc., 62 Whittemore Avenue, Cambridge, MA 02140 USA. In Canada, 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6. GCP0083 PAB-126-1216 Version 10.27.16 14