Acoustray perimeter cavity stops

Similar documents
Cavity closers, fire & acoustic stops Thermo-loc standard cavity closers Thermo-loc plus X and plus C cavity closers Thermo-loc

Gas barrier and damp proofing accessories

T-Barrier System. Timber Frame Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

T-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

Fire protection for timber frame & masonry cavity walls

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

50948-RHN Putney. 06 January This document includes: F30. Accessories/ sundry items for brick/ block/ stone walling. Code Section Revision Dated

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

System 2000 horizontal cavity trays - lead attached

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

TCB & PWCB CAVITY BARRIERS Fire Protection for timber/steel frame & masonry cavity walls

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

June Non - Residential Refurbishment Separating floors

Polypipe TDI. A comprehensive range of products designed to provide complete and economical solutions to cold bridging and other insulation problems.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

June Residential Refurbishment Separating floors

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

fire, thermal & acoustic insulation

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

SP FIRESTOP SYSTEMS The purpose-made solution for cavity fire stopping

HP Partial Fill. Robust, long-lasting protection

June Residential Refurbishment Basements

Cavity Tray Application

9 Revision B

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

June Non - Residential Refurbishment 5.5 Basements

Polyfoam Floorboard For thermal insulation of floors

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

Underfloor & through wall ventilation 99 Airbrick 100 Telescopic underfloor vent 101 Accessories 102 Cavity sleeves Internal grilles and

A Handbook of thermal bridging details incorporating aircrete blocks

June Non - Residential New Build Partition walls

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

April Section 4.3. Separating Floors

Insulation - Products

Part E robustdetails. robustdetails. January 2018 Update Pack

Jabfloor High Performance (HP) 70 and 100

CI/SfB l l l Ym1 l (M2) l July Superior 4 in 1 insulation TIMBER FRAME SOLUTIONS GUIDE

Linear & Trapezoidal Firestop Systems

CI/SfB. October 2003

Suspended timber upper floors

Technical information & installation advice

Cavity Wall Insulation 162 Roofing & Flooring Insulation 168 Fire Protection 172 Acoustic Protection 174

Product. Regulations. Rockwool Ltd Pencoed Bridgend CF35 6NY Tel: Fax: Agrément Certificate No 93/2884 Second issue*

Multi-layer Insulation Blanket for Walls

Jabfloor is also available in higher grades up to Jabfloor 250 which may be required in certain specialist industrial and commercial applications.

URSA ACOUSTIC ROLL URSA GLASSWOOL.

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT

June Residential Refurbishment Exposed soffit floors

June Residential Refurbishment Separating walls

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

URSA MINERAL WOOL URSA Cavity Batts

URSA TF Roll URSA GLASSWOOL.

Quality Insulation Converters Product Guide

Fire performance of curtain walls and rainscreens

SIDERISE SC cavity barriers & fire stops for suspended ceilings

PAGE 415. Part 9. External works. 9.1 Garages. 9.2 Drives, paths and landscaping

URSA Cavity Batts URSA GLASSWOOL.

Rockwool Ltd Pencoed Bridgend Mid Glamorgan CF35 6NY Tel: Fax:

Owens-Corning Building Products (UK) Ltd P O Box 10 St Helens Merseyside WA10 3NS Tel: Fax:

Closers. Thermal Acoustic & Fire-Rated Closers Vertical & Horizontal Applications. Fire rated closers are identified with a prefix in red as follows:

Light steel frame walls

April Section 5. Basements

VISQUEEN RADON MEMBRANE SYSTEM

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

Jabfloor 70, 100, 150, 200, 250

PRODUCT GUIDE. One of the most comprehensive selections of Insulation Products on the market

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation.

WARMFLOOR. Installation Guide.

Multi-layer Insulation Blanket for Walls

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100


BISON PRECAST FLOORING SPECIFICATION

How to build compliant SPANDREL PANELS. Guidance on building and installing spandrel panels for party walls above masonry

Floors. STEICOjoist for floors

Concrete Soffit Direct Fix

TDIPG1 July Polypipe TDI. TDI Product Guide. For prices see the Polypipe Below Ground Drainage Trade Price List

Multi-layer Insulation Blanket for

June Residential New Build Timber Frame Walls

FLOORING MOISTURE AND GAS PROTECTION CHOOSING THE RIGHT MEMBRANE TO MAKE FLOORS DRY. Inner core includes recycled material.

Regulations Detail Sheet 1

Best Prac ce Guide No. 2. (Version 1 April 2015) Design and Installa on guidelines for par al fill cavity wall boards

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

How glass or rock mineral wool works in a wall or floor cavity

CALL TO TALK TO THE SAS TEAM

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

GypLyner UNIVERSAL Metal framed wall lining system

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Basement Board High Performance (HP) 70 and 100

Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

Visqueen Gas Barrier STRUCTURAL WATERPROOFING AND GAS PROTECTION SYSTEMS. CE Mark to EN 13967

CERTIFICATE OF APPROVAL No CF 5363 NULLIFIRE LIMITED

Transcription:

Acoustray perimeter cavity stops Patented* acoustic fire-rated cavity stop and drainage tray * Patent number: GB2424658 To prevent the transmission of flanking noise between floor levels and external wall junctions As a fire stop with integrated cavity tray and weeps Reduces flanking noise transmission with the unique benefit of integrating a preformed adjustable cavity tray and insulation panel Saves installation problems due to its ability to be installed independently to the internal wall No secondary fixing required No break in insulation, no cold bridging The unique fixing flange with drain holes eliminates the need for external weeps The main body of the Acoustray is manufactured in a rigid plastic Acts as formwork for floated screeds on beam floor construction As a fire stop achieves 90 minutes fire integrity and insulation to BS 476 Part 20 : 1987 Ideal for refurbishment work as only the outer leaf requires to be removed to install, without the need to fix to inner leaf Flanking noise transmission within a building is a potential problem where more than one dwelling occurs, primarily between apartment/flat type dwellings. If the cavity wall is not fully filled with insulation, flanking noise will transmit through walls and create a disturbance to surrounding occupants (see fig.1). The problem in trying to create a required cavity stop is to secure an acoustic grade insulation directly adjacent to the floor slab. However by doing this the cavity in a localised area will be bridged so requiring a cavity tray. To compensate for a cavity tray the inner construction will have to remain at an accessible level and the cavity insulation trimmed back to accept a dpc, resulting in lower productivity and potential cold bridging issues (see fig.2). Following the addition of a cavity tray, weep holes will be required at regular centres, which can affect the aesthetic appearance of fascias with visible water drainage points. The unique Acoustray alleviates all these problems as it serves many functions in one (see fig.3). Manufactured to BS EN ISO 9001:2000 Complies with Building Regulations Part E Resistance to the passage of sound Complies with Building Regulations Part B Internal fire spread (structure) Complies with Robust Details edition 2 (Jan 2005) Manufactured in polypropylene. Available in black only Cavity options available Supplied in convenient 500mm lengths Fig.1 Fig.2 Fig.3 Page 1 of 2 see next page 43

Acoustray perimeter cavity stops Patented* acoustic fire-rated cavity stop and drainage tray Fig.4 Page 2 of 2 The Acoustray has been designed for installation along the full perimeter of the building at floor slab level as work proceeds. Position and lay each Acoustray within the external wall (see fig.4) ensuring that the insulation is directly adjacent to the floor slab and compressed within the cavity. The system butt joins to form a continuous barrier with additional polyband strips for sealing each Acoustray (see fig.5). The Acoustray comes in cavity options, mainly for the selection of insulation, with an adjustable cavity tray that should naturally lean back and rest against the cavity wall insulation to protect the clear cavity (see figs 6 & 7). Cavity wall Insulation Where full fill cavity wall insulation is used there is no requirement for an acoustic cavity stop Where partial fill cavity wall insulation is used see figs 6 & 7 Fig.6 shows the Acoustray fitted with insulation spanning the full cavity width. This option requires the cavity wall insulation to be cut at the section where the Acoustray is to be installed and is recommended for full fire resistance and acoustic requirements Fig.7 shows the Acoustray fitted with insulation spanning only the clear cavity width. This option allows the cavity wall insulation to be installed as normal without cutting at the floor slab level and is recommended for acoustic requirements only How to order To calculate quantities divide the overall length of the required cavity wall run by 500mm, allow an additional unit for each corner for cutting. Always round up to the next whole number Determine and stipulate the cavity width that the Acoustray needs to suit. (see figs 6 & 7 for partial fill or full fill cavity options) Please allow for Polyband strip for all joints (approximately 300mm is required per joint) Fig.5 Fig.6 Manufacturer: Timloc Building Products, Rawcliffe Road, Goole, East Yorkshire, DN14 6UQ. Tel: 01405 765567, Type(s) and location(s): Acoustray FireRated acoustic cavity stop & drainage tray to be installed along the full perimeter of the building at floor slab level as work proceeds. Position and lay each Acoustray within the external wall directly adjacent to the floor slab, allow 300mm of polyband strip to join two units. Fixed in conjunction with Timloc Acoustdpc & Acousformer. Reference: ACS Range Options: ACS50/220 50mm cavity ACS65/220 65mm cavity ACS75/220 75mm cavity ACS85/220 85mm cavity ACS100/220 100mm cavity ACSTAPE Polyband Strip Acoustray Fig.7 Description Cavity Insulation Length Qty Product code Acoustic cavity stop 50mm 220mm 500mm 22 ACS50/220 Acoustic cavity stop 65mm 220mm 500mm 16 ACS65/220* Acoustic cavity stop 75mm 220mm 500mm 16 ACS75/220 Acoustic cavity stop 85mm 220mm 500mm 12 ACS85/220* Acoustic cavity stop 100mm 220mm 500mm 12 ACS100/220 Polyband strip 35mtr 1 ACSTAPE * Special order - non stock items 44

Acousdpc vertical cavity stops Vertical acoustic fire-rated cavity stop and DPC Effectively reduces the transmission of flanking noise at party wall and external wall junctions As a fire stop with integrated DPC The Acousdpc has been developed to offer vertical protection and complement the horizontal Acoustray and Acousformer systems in minimising flanking noise transmission along the cavity of an external cavity wall at the intersection of a party wall. The Acousdpc also operates fully as an effective fire barrier cavity stop and in conjunction with the polythene DPC has no risk of water penetration. Where a party wall meets the cavity wall, Building Regulations stipulate the use of a mineral wool closer for sound insulation purposes. The NHBC requires that any such closer is protected by a suitable DPC. The Acousdpc has been developed to meet these requirements. Complies with Building Regulations Part E & B Fully compatible with horizontal Acoustray Excellent sound insulation properties As a fire stop achieves 4 hours (240 minutes) fire integrity to BS 476 Part 20 : 1987 Cavity options available Self supported by compression fit Easily installed Manufactured to BS EN ISO 9001:2000 Complies with Building Regulations Part E Resistance to the passage of sound Complies with Building Regulations Part B Internal fire spread (structure) Complies with Robust Details edition 2 (Jan 2005) Manufactured with BS6515 Polythene DPC Supplied in 1.2 metre lengths Cavity options available Rockfibre insulation slab 260mm width insulation VACS50 VACS65 VACS75 VACS85 VACS100 Page 1 of 2 see next page 45

Acousdpc vertical cavity stops Vertical acoustic fire-rated cavity stop and DPC Page 2 of 2 Installation must follow good practice for the detailing of damp proof courses, as set out in the relevant clauses of BS 5628: Part 3, BS 8215 and BS 8000: Part 3. Acousdpc should be built in as brickwork/block work proceeds. The DPC projects beyond the insulation by 50mm on each side and should be installed to compress against the inside face of the outer leaf. Supplied in 1.2mtr lengths of insulation with an additional 100mm overlap of DPC and to cavity size required. Units easily cut on site for detailing. Where more than one length is required, joining lengths is by simply butt jointing together. The upper piece must be installed with the 100mm DPC extension at the bottom, lapping to the outside of the lower piece ensuring a tight butt joint of the insulation. Vertical protection is given without breaks at floor level, but when installed in conjunction with the horizontal Acoustray, the horizontal tray will stop and restart around the vertical. To allow both systems to intersect simply notch a cut into the 50mm dpc overhang and slot over the horizontal Acoustray. Due to the flexible nature of the rockfibre insulation some local delaminating may occur during site handling or installation. This does not detract from the performance of the product. Junction between external cavity wall & party wall Manufacturer: Timloc Building Products, Rawcliffe Road, Goole, East Yorkshire, DN14 6UQ. Tel: 01405 765567, Type(s) and location(s): Acousdpc FireRated acoustic cavity stop & dpc to be installed vertically as work proceeds. Position Acousdpc s vertically where a party wall meets the cavity wall, supplied in 1.2 mtr lengths and butt jointed. Fixed in conjunction with Timloc Acoustray & Acousformer. Reference: VACS Range Options: VACS50 50mm cavity VACS65 65mm cavity VACS75 75mm cavity VACS85 85mm cavity VACS100 100mm cavity Acousdpc fire rated cavity stop Cavity size Length Dimensions Qty Product code 50mm cavity 1.2mtr 360 x 260 x 50mm 10 VACS50 65mm cavity 1.2mtr 360 x 260 x 65mm * VACS65 75mm cavity 1.2mtr 360 x 260 x 75mm 8 VACS75 85mm cavity 1.2mtr 360 x 260 x 85mm * VACS85 100mm cavity 1.2mtr 360 x 260 x 100mm 6 VACS100 * to order 46

Acoustop cavity stop socks Thermal and acoustic fire stops To restrict the spread of smoke and flames within external masonary and timber frame walls To further minimise the effect of flanking noise pollution at wall junctions Acoustop cavity stop socks are lengths of low resin, non-combustible, Rockwell mineral wool, sleeved in 50 micron polythene for on-site weather protection 4 hours (240 minutes) fire integrity - Warrington Fire Research test Polythene encapsulated cavity stop sock Available in standard widths of 65, 90, 100mm and special cavity widths are available on request Meets the requirements of the Robust Detail, Part B and NHBC Standards TCB (flanged stopsock) also available for timber frame applications Manufactured to BS EN ISO 9001 : 2000 Complies with all relevant Building Regulations Meets all relevant British Standards Non-conbustible to BS476 : Part 4 1970 (1984) Class 1 Surface spread of flame to BS476 part 7 1987 Class O to the Building Regulations Manufactured using Rockwool mineral wool Rockwool use no CFC s, HCFC s in the manufacturing process Thermal conductivity of Rockwool insulation 0.037 Timloc cavity stop socks are designed to friction fit within the cavity and are easily installed both vertically and horizontally into the cavity during construction. Care should be taken to ensure butt joints are closely fitted and the cavity sock fully fills the cavity. This method should be incorporated with a preformed horizontal cavity tray (refer to Technical Department for appropriate type) and proprietary wall weep vents (Timloc code 1143) at 900mm centres, to prevent water ingress from bridging the cavity. How to order To calculate quantities divide the overall length of the required cavity wall run by 1.2m, allow an additional unit for each corner for cutting. Always round up to the next whole number Determine and stipulate the cavity width that the Acoustop needs to suit Manufacturer: Timloc Building Products, Rawcliffe Road, Goole, East Yorkshire, DN14 6UQ. Tel: 01405 765567, Type(s) and location(s): Acoustop - thermal & acoustic fire stops to be installed vertically and horizontally as work proceeds. Position Acoustop where a party wall meets the cavity wall or at floor levels, supplied in 1.2 mtr lengths and butt jointed. Fixed in conjunction with Timloc Acoustray & Acousformers. Reference: ACSS Range Options: ACSS50 50mm cavity ACSS75 75mm cavity ACSS85 85mm cavity ACSS100 100mm cavity ACSS115 115mm cavity ACSS125 125mm cavity Acoustop cavity stop socks Width Size Qty Fire integrity Product code 50mm 65 x 65 x 1200mm 40 4 hours ACSS50 75mm 90 x 75 x 1200mm 35 4 hours ACSS75 85mm 100 x 100 x 1200mm 20 4 hours ACSS85 90mm 105 x 120 x 1200mm 20 4 hours ACSS90 100mm 120 x 100 x 1200mm 20 4 hours ACSS100 115mm 130 x 100 x 1200mm 20 4 hours ACSS115 125mm 140 x 100 x 1200mm 20 4 hours ACSS125 47

Acousformer and Slabformer horizontal cavity stops Acoustic fire-rated cavity stop and slab former To prevent the passage of sound between separating floors and party wall junctions Performs the function of shuttering when ground and separating floors are carried to the cavity face of the leaf of party walls Reduces the passage of sound and flanking noise transmission The cavity stop achieves 90 minutes fire integrity and insulation to BS 476 : Part 20 : 1987 Performs the function of a floor slab shuttering Easy fixing and saves time Manufactured in a rigid PVC Integrated high density Rockfibre insulation slab Optional 150mm & 225mm slab Passage of sound within a building is a potential problem where more than one dwelling occurs, primarily between apartment/flat type dwellings. The Building Regulations and accompanied Robust Details address this problem by stipulating that ground floors and separating floors must not be continued between dwellings and stipulate the use of a cavity stop. Breaking the floor continuity at party walls will reduce the transmission of sound via the floor. To achieve such a detail when concrete is applied in situ or when block and beam flooring is used with concrete infill, a separate (removable) shuttering and a secondary cavity stop would be required. The unique Acousformer addresses all these issues as it performs as rigid PVC shuttering that is intended to remain in place to maintain an even and clean cavity when concrete is poured. The combination of a PVC body with fixing flange and high-density Rockfibre slab will perform as an acoustic barrier and a 90-minute fire-rated cavity stop. Replicating such features with flexible low-density acoustic grade insulation within the cavity, with no secure fixing would be inadequate due to potential slippage. Uneven, reduced and even closed cavity problems will result from minimal compressive strength insulation. For concrete ground floor applications when shuttering only is required and no acoustic or fire rated cavity stop is required, then the Slabformer is to be used which has polystyrene infill for structural support only. Manufactured to BS EN ISO 9001: 2000 Complies with Building Regulations Part E Resistance to the passage of sound Complies with Building Regulations Part B Internal fire spread (structure) Complies with Robust Details edition 2 (Jan 2005) to be installed and meets all relevant Building Regulations and British Standards Manufactured in PVC Supplied in 2 metre lengths Available in white only Fixed 75mm cavity option only Rockfibre or Polystyrene fill 150mm & 225mm deep insulation options Acousformer (fixed at separating floor) Slabformer (fixed direct to foundation) Page 1 of 2 see next page 48

Acousformer and Slabformer horizontal cavity stops Acoustic fire-rated cavity stop and slab former Page 2 of 2 Acousformer The Acousformer has been designed for installation along the full length of the party wall at separating floor slab level as work proceeds to offer a shuttering and acoustic fire stop. Position and lay each unit with the exposed insulation face down within the cavity of the party wall. Ensure the support flange overhangs the masonry for support and is tight within the cavity (cavity will need to be clean and flush with no mortar drops) then nail fix along one edge. Multiple units will require butt jointing to form a continuous former and cavity stop. For corner applications the units will cross over with the support flange forming an overlap. At junctions with an external cavity wall, stop the Acousformer and continue with vertical protection with the Acousdpc. Slabformer The Slabformer has been designed for installation along the full length of the party wall at ground floor slab level as work proceeds to offer non-removable shuttering with no acoustic or fire rating properties. Position and lay each unit with exposed insulation facing up and fix to the foundation or foundation blocks by nailing through the 25mm flange. Multiple units will require butt jointing to form a continuous former. For corner applications the units will cross over with the support flange forming an overlap. At junctions with an external cavity wall, stop the Acousformer and continue with vertical protection with the Acousdpc. Slabformer (fixed direct to foundation) Slabformer (fixed to foundation block) Manufacturer: Timloc Building Products, Rawcliffe Road, Goole, East Yorkshire, DN14 6UQ. Tel: 01405 765567, Type(s) and location(s): Acousformer FireRated acoustic cavity stop to be installed horizontally along the full compartment wall of the build ing at floor slab level as work proceeds. Position and lay each Acousformer directly adjacent to the floor slab, only mortar and fix one support flange. Fixed in conjunction with Timloc Acoustdpc & Acoustray. Reference: ACSF Range Options: ACSF75/150 150mm deep ACSF75/225 225mm deep Manufacturer: Timloc Building Products, Rawcliffe Road, Goole, East Yorkshire, DN14 6UQ. Tel: 01405 765567, Type(s) and location(s): Slabformer cavity former to be installed horizontally at ground level along the base of a compartment wall of the building to accept a floor slab as work proceeds. Position and lay each Slabformer directly adjacent to the floor slab, fix along the support flanges. Reference: SF Range Options: SF75/150 150mm deep SF75/225 225mm deep Acousformer Slabformer Description Acousformer - 150mm rockfibre Acousformer - 225mm rockfibre Product code ACSF75/150 ACSF75/225 Description Slabformer - 150mm polystyrene Slabformer - 225mm polystyrene Product code SF75/150 SF75/225 49