The Positive Displacement Pipetting Reference

Similar documents
Ergonomic Pipetting for Problem Liquids!

Accessing the E-Gel 96 System via the Quad-Z 215 with Disposable Tips

Reformatting Procedures Employing a Quad-Z 215 with Disposable Tips

Maximize reproducibility of your biological sample prep

Fast Preparative Column Liquid Chromatography (PCLC)

Automated On-Line SDS Removal from Diminutive Protein Samples Prior to Capillary HPLC Application Note 221

Fully-Automated Workstation for Direct camp Enzyme Immunoassay Kit

Optimizing Purified Sample Recovery on Reverse-Phase HPLC Systems

Mitochondrion DNA site Mutation Real Time PCR Kit

Varicella Zoster Virus Real Time PCR Kit

HBV Quantitative & YMDD Mutation Real Time PCR Kit

Campylobacter Jejuni Real Time PCR Kit

HBV Quantitative & YMDD Mutation Real Time PCR Kit

Streamlined Purification of Assay-Ready Oligonucleotides by Automated HPLC

Simultaneous Preparative HPLC Fraction Collection and Column Regeneration

HBV Genotype B&C Real Time PCR Kit

Brucella Real Time PCR Kit

Vibrio Vulnificus Real Time PCR Kit

One Step SYBR PrimeScript RT-PCR Kit II (Perfect Real Time)

High Quality Pipette Tips for Consistent and Reliable Results

BIOFOOD Kits Kits for vertebrate species detection and identification in food using genetic markers (Ref )

Simplexa EBV Quantitation Standards

Automated 2-D HPLC Using Trap Columns for the Fractionation, Isolation and Screening of Natural Products

HPV 16&18 Real Time PCR Kit

Table of Contents. I. Kit Components...2. Storage...2. Principle...2. IV. Precautions for operation...3. V. Protocol : reverse transcription...

GPC Clean-up Systems. Benefits to GPC post-extraction clean-up:

High-throughput Miniaturized Quantitative PCR with the Echo 525 Liquid Handler

HDV Real Time RT-PCR Kit

HBV Quantitative Real Time PCR Kit

Transport Medium for Storage and Transportation of Respiratory Swabs

A Top Tip System! H I G H - T E C H D I S P O S A B L E S

Table of Contents. Pipette Tips. Table of Contents

Transfusion-transmitted Virus(TTV) Real Time PCR Kit

Ureaplasma Urealyticum Real Time PCR Kit

A Picofluor method for RNA quantitation using RiboGreen

Schistosoma Japonicum Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

High Quality Pipette Tips for Consistent and Reliable Results

Salmonella Typhi Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

Entry Level Assessment Blueprint Biotechnology

DNAse I qualification and sample treatment

Enteroinvasive E. Coil(EIEC) Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

Table of Contents. Pipette Tips. Table of Contents

AccuPrep 96 Genomic DNA Extraction Kit Cat. No.: K

The best products and services

Using the SOLO for PCR Automation Alan H. Katz, PhD Hudson Control Group

AmpliSens HCV-EPh PCR kit

AFP mrna Expression in Peripheral Blood Real Time RT-PCR Kit

DEVELOP YOUR LAB, YOUR WAY. The FLOW Solution: Expand your potential today

Hy-Fy High Fidelity Mix (x2)

Ureaplasma Urealyticum Real Time PCR Kit

PrimeScript One Step RT-PCR Kit Ver.2 (Dye Plus)

-<1 ABD0S ' Pipette Tips. Trusted Partner in Life Sciences Plastic Laboratory Products.

Yersinia pestis Real Time PCR Kit

5X WGS Fragmentation Mix

AmpliSens Enterovirus-EPh PCR kit

Table of Contents. 2. Preparation of cell lysate from adherent cells cultured on 96-well plates...4

MANUAL 96-CHANNEL PIPET TING

PIPETMAX : Automation of the Illumina Nextera XT DNA Library Preparation Kit

Code: IDK-006 Ver: 1 MTHFR A1298C. Detection system of the A1298C mutation in the human Methylen-tetraydrofolate reductase gene. Reg.

Catalog No. SA-40004: 50 preparation SA-40003: 100 preparation

Isolation of genomic DNA from buccal swabs - a brief protocol. Assessment of DNA concentration and purity

Liquidator 96. Pipette 96 Wells at Once With the Simplicity of a Manual Pipette

Listeria Monocytogenes Real Time PCR Kit

Event-specific Method for the Quantification of Soybean SYHT0H2 by Real-time PCR. Validated Method

RPM. Rapid Pure Miniprep Kit preps preps preps preps preps

Protocol for amplification of measles sequencing window (N-450)

Better Pipetting: Better Data, Better Science.

500U. Unit Definition. Storage Buffer. 10X PCR Buffer with Mg 2+

AmpliSens HCV-genotype-EPh PCR kit

Taq DNA Polymerase Pfu DNA Polymerase. For DNA Amplification

HELINI White spot Syndrome virus [WSSV] Real-time PCR Kit

PCR-ReIated Products User's Instruction

Taq + dntps #EZ U

Gene expression runs on Rob.

Spin Micro DNA Extraction Kit

genesig Easy AnimalFINDER Kit for use on the genesig q16

genesig Easy AnimalFINDER Kit for use on the genesig q16

Table of contents. I. Description...2. II. Principle...2. III. Kit Components...3. IV. Storage...3. V. Features...4. VI. Precautions for Operation...

Job Ready Assessment Blueprint. Biotechnology. Test Code: 4075 / Version: 01. Copyright 2014 NOCTI. All Rights Reserved.

Job Ready Assessment Blueprint. Biotechnology. Test Code: 4075 / Version: 01. Copyright 2014 NOCTI. All Rights Reserved.

Vibrio Vulnificus Real Time PCR Kit

version BROCHURE MS Pipette

mrna Selective PCR Kit (AMV) Ver.1.1

Automated Protocol for Extract-N-Amp Blood PCR Kits Using the Sciclone ALH 3000 Workstation (Caliper Life Sciences)

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

ProNex DNA QC Assay Calibration Kit, 7500

foodproof Sample Preparation Kit II

Rift Valley Fever Virus RT-PCR Kit

Multiplex PCR Assay Kit Ver.2

Changing the world of laboratory developed testing

For in vitro Veterinary Diagnostics only. DNA Extraction and PCR Detection Kit for Pasteurella multocida.

Use of the GenePrint 10 System with the Applied Biosystems 3500 and 3500xL Genetic Analyzers and POP-7 Polymer

TaKaRa One Step RNA PCR Kit (AMV)

DIRECTION FOR USE. Art. No / /25 reactions in vitro Diagnosticum for birds

Automated Protocol for Extract-N-Amp Plant PCR Kits Using the Tecan Freedom EVO 150 Workstation

General Product Insert. End-Point PCR/RT-PCR Kit Product# EPxxxxx

SunScript One Step RT-PCR Kit

Teacher Assessment Blueprint. Biotechnology. Test Code: 5189 / Version: 01. Copyright 2014 NOCTI. All Rights Reserved.

Measles Virus Real Time RT-PCR Kit

Transcription:

The Positive Displacement Pipetting Reference

Extreme accuracy and precision Problem liquids Contamination-free working

MICROMAN The Positive Displacement Pipetting Reference How does it work? 1. Aspirate 2. Dispense > No air-to-liquid interface. > The desired volume is aspirated rapidly and completely. CP } Piston Capillary > The positive wiping action of the piston against the capillary wall assures accurate dispensing of even the most viscous sample and avoids any carry-over. Improve accuracy and precision with problem liquids Accuracy and precision with viscous and dense samples The most convenient solution when pipetting liquids such as oil, enzyme solutions, syrup, buffers, blood, cosmetic cream. % Random error 3.5 3 Regular Air displacement Pipette 2.5 2 1.5 1 0. 5 0 MICROMAN % Systematic error 5 4.5 4 Regular Air displacement Pipette 3.5 3 2.5 2 1.5 1 0.5 MICROMAN 0 0 40 70 80 85 90 95 100 Viscosity/Density % Glycerol 0 40 60 80 85 90 95 100 Viscosity/Density % Glycerol Reference: Gilson S.A.S. Glycerol pipetting* % Regular air displacement pipette Accuracy and precision with volatile samples The most convenient solution when pipetting volatile liquids such as acetone, chloroform, hexane, alcohol and other solvents. Microman % Random error % Systematic error Reference: Gilson S.A.S. Acetone pipetting* * For further information, read Gilson's Application Note «How to deal with biological procedures and problem liquids» available at www.gilson.com

100% protection against contamination The safest solution when pipetting liquids such as DNA fragments, PCR templates, enzyme solutions, radio labeled components. Piston Unprotected air space: - Vapor contamination - Aerosol contamination Protected air space: - No aerosol contamination - No vapors Regular Air Displacement Pipette Microman Positive Displacement Pipette Pipette Protection: - Acid, base and solvent - Radio labeled components Disposable CP Pipette's shaft never in contact with corrosive vapors or liquids Sample Protection: - Molecular biology - Forensic Sciences No air cushion No aerosol Users Protection: - Infectious solution - Radio labeled components Built-in ejector No hand contact More reliable than filter tips According to Roche, leader of PCR based technologies, one of the critical factors for successful PCR is «a dedicated (used only for PCR) set of pipettes, preferably positive displacement pipettes.»** Sambrook, Fritsch and Maniatis highly recommend the use of positive displacement pipettes for critical PCR protocols.*** ** Copyright 2005 Roche. «Critical factors for Successful PCR,» Roche Molecular Biochemicals PCR Application Manual, 2 nd edition. www.roche-applied-science.com/prod_inf/manuals/pcr_man/#2 *** Sambrook, Fritsch and Maniatis. «In Vitro Amplification of DNA by the Polymerase Chain Reaction,» Molecular Cloning: A Laboratory Manual, 2 nd edition 14:14, 1989.

Microman Range > 6 models cover a large volume range from 1 µl to 1000 µl. > Permanently calibrated. > Lightweight design, only 50 g! > Designed for both right and left handed users. > Color-coded push-button with volume range. > Built-in ejector. > Delivered with the Gilson's original ISO 8655 certificate of conformity. > Red push-button for autoclavable models. Capillaries and Pistons Range (CPs) > Disposable CP, capillaries made of pure polypropylene. > Easy to fit and to eject. > Pre-assembled, ready-to-use and racked CPs in Tipacks from 1 µl to 1000 µl. > Sterilized CPs from 1 µl to 1000 µl. > Slim and long CPs fit into even the narrowest and deepest test tubes. Tipack CP1000 > Entry level CP available non-assembled. Tipack CP1000ST

Microman Models Gilson Maximum Permissible Errors ISO 8655 Maximum Permissible Errors Model Capillary Reference Volume Systematic Random Systematic Random Piston Number (µl) error (µl) error (µl) error (µl) error (µl) M10 CP10 F148501 Min. 1 ± 0.09 0.03 ± 0.20 0.10 5 ± 0.10 0.03 ± 0.20 0.10 AUTOCLAVABLE Max. 10 ± 0.15 0.06 ± 0.20 0.10 M25 CP25 F148502 Min. 3 ± 0.25 0.08 ± 0.70 0.30 10 ± 0.27 0.08 ± 0.70 0.30 Max. 25 ± 0.30 0.10 ± 0.70 0.30 M50 CP50 F148503 Min. 20 ± 0.34 0.20 ± 0.70 0.30 Max. 50 ± 0.70 0.30 ± 0.70 0.30 M100 CP100 F148504 Min. 10 ± 0.50 0.20 ± 1.50 0.60 50 ± 0.75 0.30 ± 1.50 0.60 AUTOCLAVABLE Max. 100 ± 1.00 0.40 ± 1.50 0.60 M250 CP250 F148505 Min. 50 ± 1.50 0.30 ± 6.00 2.00 100 ± 1.70 0.30 ± 6.00 2.00 Max. 250 ± 2.50 0.50 ± 6.00 2.00 M1000 CP1000 F148506 Min. 100 ± 3.00 1.60 ± 12.00 4.00 500 ± 5.00 2.50 ± 12.00 4.00 Max. 1000 ± 8.00 4.00 ± 12.00 4.00 Microman Capillary Pistons Capillary Microman Reference Quantity/Box Sterilized Assembled Piston Model number and Racked in Tipack CP10 M10 F148412 192 No Yes CP10 M10 F148312 960 No Yes CP10ST M10 F148413 192 Yes Yes CP10ST M10 F148313 960 Yes Yes CP25 M25 F148112 200 No No CP50 M50 F148113 200 No No CP100 M100 F148414 192 No Yes CP100 M100 F148314 960 No Yes CP100ST M100 F148415 192 Yes Yes CP100ST M100 F148315 960 Yes Yes CP250 M250 F148114 200 No No CP1000 M1000 F148560 182 No Yes CP1000ST M1000 F148180 182 Yes Yes Distributed by World Headquarters Gilson, Inc. 3000 W. Beltline Hwy., P.O. Box 620027, Middleton, WI 53562-0027, USA Telephone: (1) 800-445-7661 or (1) 608-836-1551 Fax: (1) 608-831-4451 Internet: www.gilson.com E-mail: sales@gilson.com, service@gilson.com, training@gilson.com Gilson S.A.S. 19, avenue des Entrepreneurs, BP 145, F-95400, Villiers-le-Bel, FRANCE Telephone: (33-1) 34-29-50-00 Fax: (33-1) 34-29-50-20 LT800458E. Copyright 2005. Gilson S.A.S. All rights reserved. Printed in France, March 2005. Specifi cations subject to change without notice. Gilson, Inc., Gilson S.A.S., and Cyberlab, Inc. are ISO 9001 certified.