Simplexa EBV Quantitation Standards

Similar documents
Simplexa Spectral Calibration Panel

HBV Quantitative & YMDD Mutation Real Time PCR Kit

HBV Quantitative & YMDD Mutation Real Time PCR Kit

HELINI Hepatitis B virus [HBV] Real-time PCR Kit (Genotype A to H)

HBV Quantitative Real Time PCR Kit

HPV 16&18 Real Time PCR Kit

Varicella Zoster Virus Real Time PCR Kit

HELINI White spot Syndrome virus [WSSV] Real-time PCR Kit

GI DNA Extraction Kit

Brucella Real Time PCR Kit

HDV Real Time RT-PCR Kit

Luteinizing Hormone ELISA kit

Transfusion-transmitted Virus(TTV) Real Time PCR Kit

STI Extraction Kit. REF: ; 48 extractions. Store at 15 C - 35 C. For use with the Nextractor Instrument. For Professional Use Only

HBV Genotype B&C Real Time PCR Kit

Vibrio Vulnificus Real Time PCR Kit

Campylobacter Jejuni Real Time PCR Kit

Mitochondrion DNA site Mutation Real Time PCR Kit

Enteroinvasive E. Coil(EIEC) Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

Ureaplasma Urealyticum Real Time PCR Kit

Product Insert 1 1 Quantified RNA Standards are provided as 100 ng/µl, 10 ng/µl, 1 ng/µl, 100 pg/µl, 10 pg/µl and 1 pg/µl

Ureaplasma Urealyticum Real Time PCR Kit

Vibrio Vulnificus Real Time PCR Kit

Yersinia pestis Real Time PCR Kit

Schistosoma Japonicum Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

AFP mrna Expression in Peripheral Blood Real Time RT-PCR Kit

DIRECTION FOR USE. Art. No / /25 reactions in vitro Diagnosticum for birds

For in vitro Veterinary Diagnostics only. DNA Extraction and PCR Detection Kit for Pasteurella multocida.

For in vitro Veterinary Diagnostics only. Kylt Brachyspira spp. Real-Time PCR Detection.

AmoyDx JAK2 Mutation Detection Kit

foodproof SL GMO Maize Multiplex Detection Kit

For in Vitro Diagnostic Use IVD

foodproof SL GMO Maize Multiplex Detection Kit

ZIKA Virus (ZIKAV) Real Time RT-PCR Kit

West Nile Virus Real Time RT-PCR Kit

Salmonella Typhi Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

foodproof SL Staphylococcus aureus Detection Kit

RealLine HBV qualitative Uni-Format

Protocol for amplification of measles sequencing window (N-450)

Taura Syndrome Virus (TSV) RT-PCR Kit

For in vitro Veterinary Diagnostics only. Kylt Chlamydiaceae Screening. Real-Time PCR Detection.

Rift Valley Fever Virus RT-PCR Kit

Measles Virus Real Time RT-PCR Kit

For in vitro Veterinary Diagnostics only. Kylt MHRS Triplex. Real-Time PCR Detection.

Coxsackie Virus Real Time RT-PCR Kit

For in vitro Veterinary Diagnostics only. Kylt MHRS. Real-Time PCR Detection kit for Mycoplasma hyorhinis and hyosynoviae.

Plasma-Serum HPV 6/16 TaqMan PCR Kit Product# TM42000

For in vitro Veterinary Diagnostics only. Kylt E. coli F18, F41, Stx2e. Real-Time PCR Detection.

Salmonella paratyphi Real Time PCR Kit

Trioplex Real-time RT-PCR Assay. For use under an Emergency Use Authorization only

Clostridium difficile TaqMan PCR Kit Product# TM37100

For in vitro Veterinary Diagnostics only. Detection Reagents specific for. Chlamydia psittaci Real-Time PCR.

Direct amplification of FTA and swab samples using the Investigator Argus X-12 QS Kit

Human IL-1 alpha ELISA Kit

DNA Extraction and Real-Time PCR Detection Kit for Mycoplasma gallisepticum live vaccine strain ts-11.

Product# TM Intended Use. use only and not for use in diagnostic procedures.

Multiplex RT for TaqMan Array Human MicroRNA Panel

3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: (905) Fax: (905)

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for Reticuloendotheliosis Virus

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Real-Time PCR Detection Reagents for Detection of Marek Disease Virus and differentiation between field strains and Rispens vaccine CVI988 strain

Clostridium difficile Toxin Genes A and B. Real-Time PCR Detection Kit for detection and differentiation of.

Listeria Monocytogenes Real Time PCR Kit

Human IL-6 ELISA Set

Spin Micro DNA Extraction Kit

foodproof Sample Preparation Kit II

PicoKine ELISA. Catalog number: EK7102. For the quantitation of Human concentrations in Serum and Plasma

QuickGene SP kit DNA whole blood (SP-DB)

RIBO-prep. nucleic acid extraction kit Instruction Manual

Isolation of total nucleic acids from animal and human cells using the EZ1 RNA Cell Mini Kit

For in vitro Veterinary Diagnostics only. Kylt Avian Hepatitis E. Real-Time RT-PCR Detection.

TruSeq Custom Amplicon Dx FFPE QC Kit

Human CRP Precoated ELISA kit

AmpliSens HBV-genotype-FRT PCR kit

Product# TM Product Description

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: (905) Fax: (905)

Blood DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62600

Campylobacter jejuni TaqMan PCR Kit Product# TM36100

Maxwell 16 Viral Total Nucleic Acid Purification System INSTRUCTIONS FOR USE OF PRODUCT AS1155.

Lysis Buffer A Wash Solution A Elution Buffer B Mini Filter Spin Columns 50 Collection Tubes 50 Elution tubes (1.7 ml) 100 Product Insert 1

For in vitro Veterinary Diagnostics only. Kylt Avian Nephritis Virus. Real-Time RT-PCR Detection.

Fentanyl (Human) ELISA Kit

Transport Medium for Storage and Transportation of Respiratory Swabs

For in vitro Veterinary Diagnostics only. PCR Detection Kit for Salmonella Gallinarum, Pullorum (separate detection) & DIVA 9R.

AmpliSens HCV-EPh PCR kit

(Spin Column) For purification of DNA and RNA from formalin-fixed, paraffin-embedded. tissue sections. Instruction for Use. For Research Use Only

BIOFOOD Kits Kits for vertebrate species detection and identification in food using genetic markers (Ref )

For in vitro Veterinary Diagnostics only. Kylt Chicken Astrovirus. Real-Time RT-PCR Detection.

For in vitro Veterinary Diagnostics only. PCR Detection Kit for Fowl Adenovirus.

Product Description Norgen s E. coli O157:H7 TaqMan PCR Kit is designed for the detection of E. coli O157:H7

Intended Use Norgen s HSV-1&2 TaqMan PCR Kit is designed for the detection of HSV-1&2 specific DNA in a

Product# TM Intended Use. research use only and not for use in diagnostic procedures.

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for beta-actin.

AmoyDx TM JAK2 V617F Mutation Detection Kit

General Product Insert. End-Point PCR/RT-PCR Kit Product# EPxxxxx

DRG Anti-Tissue Transglutaminase

EliGene MTB Isolation Kit

(Spin Column) For purification of DNA and RNA from formalin-fixed, paraffin-embedded tissue sections. Instruction for Use

Transcription:

Simplexa EBV Quantitation Standards REF MOL2410 Rev. C Simplexa EBV Quantitation Standards are intended to establish a standard curve with the Simplexa EBV assay on the 3M Integrated Cycler. For in vitro Diagnostic Use INTENDED USE The Focus Diagnostics Simplexa EBV Quantitation Standards are intended to establish a standard curve with the Simplexa EBV assay on the 3M Integrated Cycler. MATERIALS PROVIDED The Focus Diagnostics Simplexa TM EBV Quantitation Standards set contains sufficient materials for two reactions. Kit Component Standard 1 (QS-1) Standard 2 (QS-2) Standard 3 (QS-3) Standard 4 (QS-4) Standard 5 (QS-5) REF Description of the Quantitation Standard (QS) Kit Focus Diagnostics Standards ( REF # MOL2410) Number of tubes per Kit Reactions per Vial Volume (µl) per Vial Component Description MOL2411 MOL2412 MOL2413 MOL2414 MOL2415 MATERIALS REQUIRED BUT NOT SUPPLIED 1. Simplexa EBV ( REF MOL2400) 2. 3M Integrated Cycler with 3M Integrated Cycler Studio version 3.0 or higher 3. Universal Discs for use on the 3M Integrated Cycler 4. Universal Disc Cover Tape 5. a Roche MagNA Pure LC System and associated consumables. 6. a Roche MagNA Pure LC Total Nucleic Acid Isolation Kit (Roche Cat. No 3038505001) 7. b biomérieux NucliSENS easymag instrument and associated consumables and reagents 8. b Biohit/bioMérieux multi-channel pipette 9. b ELISA strip plate 10. Single, multi-channel and/or repeater micropipette(s) with an accuracy range between 1-10 µl, 10-100 µl and 100-1000 µl 11. Freezer (manual defrost) at -10 to -30 C (for kit component frozen storage) 12. Refrigerator at 2 to 8 C (for thawed kit components and standards) 13. Biosafety cabinet (laminar flow hood) for extractions 14. Microcentrifuge 15. Vortex mixer 16. Sterile, RNase/DNase-free disposable aerosol-barrier micropipettor tips 17. 1.5 ml polypropylene microcentrifuge tubes and racks (RNase/DNase-free tubes are recommended but not required) 18. Disposable, powder-free gloves 19. Nuclease-Free Water (Used during extraction and as the No-Template Control (NTC)) 20. Cooler racks for 1.5 ml microcentrifuge tubes a For use with Roche MagNA Pure LC extraction method b For use with biomerieux easymag extraction method

Standards Page 2 SHELF LIFE AND HANDLING 1. Store standards at -10 to -30 C (do not use a frost-free freezer). 2. After initial use store thawed standards at 2 to 8 C for no more than five (5) days. 3. Do not use standards beyond their expiration dates. WARNINGS AND PRECAUTIONS 1. For in vitro diagnostic use. 2. All human based products should be treated as potentially infectious. Source materials from which this product were derived have been screened for Hepatitis B surface antigen, Hepatitis C antibody and HIV-1/2 (AIDS) antibody by FDA-approved methods and found to be negative. However, as no known test methods can offer 100% assurance that products derived from human blood will not transmit these or other infectious agents, all controls, serum specimens and equipment coming into contact with these specimens should be considered potentially infectious and decontaminated or disposed of with proper biohazard precautions. CDC and the National Institutes of Health recommend that potentially infectious agents be handled at the Biosafety Level 2. 1,2 3. Wear personal protective equipment, such as (but not limited to) gloves and lab coats when handling kit reagents. Wash hands thoroughly when finished performing the test. 4. Do not pipette by mouth. 5. Do not smoke, drink, eat, handle contact lenses or apply make-up in areas where kit reagents and/or human specimens are being used. 6. Dispose of unused standards according to local, state and federal regulations. 7. Contamination of patient specimens or reagents can produce erroneous results. Use aseptic techniques. 8. Pipette and handle standards carefully to avoid mixing of standards from adjacent wells. 9. Use proper pipetting techniques and maintain the same pipetting pattern throughout the procedure to ensure optimal and reproducible values. 10. Do not substitute or mix standards from different lots or from other manufacturers. 11. Do not interchange the tube caps. This may cause contamination and compromise the test results. 12. Do not re-use Universal Discs that have already been exposed to patient samples or reagents. 13. Dispose of used disc without detaching or removing cover tape. INSTRUCTIONS FOR USE C. QUANTITATION STANDARD EXTRACTION AREA Perform in a dedicated area for extraction. Quantitation standard preparation for extraction should be performed in a biosafety cabinet. Extraction using Roche MagNA Pure LC extraction method 1. Extract quantitation standards using the Roche MagNA Pure Total Nucleic Acid kit and the Roche MagNA Pure LC Automated Nucleic Acid Extractor instrument. Refer to the manufacturer s Instructions for Use for nucleic acid extraction using this kit. 2. Under the Protocol drop-down menu on the MagNA Pure LC System, select Total NA, and then Total NA Variable_elution_volume.blk from the list. This will load the appropriate settings for the run. 3. The Sample Protocol should be Total NA Variable_elution_volume. 4. 200 µl should be set for the Sample Volume, and the elution volume should be set at 50 µl. 5. The dilution volume should be set at zero for all specimens. 6. Ensure that the Post Elution Protocol is set to None. 7. Ensure that quantitation standards and NTC are in the correct position on the Sample Cartridge. 8. Vortex each standard, and NTC for 2 to 4 seconds and briefly centrifuge to pull contents down to bottom of tube. 9. Pipette 200 µl of each standard and NTC into the corresponding position in the sample cartridge. 10. Visually check the level of standard and NTC in the Sample Cartridge to ensure standards were added. 11. Pulse vortex Extraction & Amplification Control DNA (IC) 2 times and briefly centrifuge to pull contents down to bottom of tube. 12. For each set of standards, pipette 100 µl of the IC into 6 ml lysis buffer in a conical tube. Mix by vortexing briefly. Add to the appropriate tray on the MagNA Pure extraction instrument. 13. Transfer the sample cartridge to the MagNA Pure LC Automated Nucleic Acid extractor and begin the extraction run. 14. After nucleic acid extraction is complete, the cartridge containing the extracted standards can be removed from the MagNA Pure and sealed. Store the extracted DNA at 2 to 8 C prior to use. Long-term storage of extracted standards at this temperature is not recommended. Keep extracted DNA specimens on a cooler block while loading disc. Extraction using biomérieux NucliSENS easymag extraction method 1. Refer to the NucliSENS easymag User Manual for operation of the instrument and software.

Standards Page 3 2. Choose the Generic template on the NucliSENS easymag software with the following settings; Default Request: Generic 2.0.1 (or equivalent) Run Name Prefix: (as appropriate) Sample ID prefix: (as appropriate) Sample Type: Primary Workflow Defaults: On-board lysis Incubation On-board Silica Incubation Sample Addition Guidance Off Reagent Tracking: Lysis, Silica, Internal Control reagent tracking disabled 3. Enter individual specimen information into Extraction Request screen as below. Sample ID: (Enter sample name) Request: Generic 2.0.1 (or equivalent) Volume (ml): 0.100 Eluate (µl): 25 Type: Primary Priority: Normal Matrix: Other 4. Create Extraction Run in NucliSENS easymag software per User Manual. 5. Vortex each standard for 2 to 4 seconds and briefly centrifuge to pull contents down to bottom of tube. 6. Pipette 100µL of standard and NTC to sample vessel(s). 7. Pulse vortex IC 2 times and briefly centrifuge to pull contents down to bottom of tube. 8. Pipette 5µL of IC to each standard and all control wells. Change tips in between standards. 9. Load sample vessel(s), new aspirator disposables, and reagents onto the easymag instrument per User Manual. 10. Initiate the on-board lysis and incubate the lysed specimens for 10 minutes before addition of magnetic silica mixture. 11. During lysis incubation period, prepare magnetic silica mixture. Mix silica and dilute in nuclease-free water by adding 1 part magnetic silica to 1 part nuclease-free water (e.g., 540µL of magnetic silica + 540µL nuclease-free water). Prepare minimally 135µL of magnetic silica mixture per specimen. 12. To transfer silica mixture into ELISA strip wells, mix magnetic silica mixture and use 1 tip and operating mode P2 of the Biohit pipette. Press Start to aspirate 1050µL of the magnetic silica mixture and press Start again to dispense the first shot back into silica mixture tube. Press Start to dispense 125µL of the magnetic silica mixture into 8 individual wells of the ELISA strip. Repeat as necessary for additional ELISA strips. 13. After the 10 minute lysis incubation, use 8 tips (per ELISA strip) and operating mode P3 of the Biohit pipette to transfer 100µL of magnetic silica mixture to each standard and NTC in the sample vessel. Place tips into the ELISA strip wells and press Start to mix and aspirate magnetic silica mixture. 14. Transfer magnetic silica mixture to appropriate sample vessel and place pipette tip(s) into specimens below the liquid level. Press Start to aspirate, dispense and mix (x3) the magnetic silica and specimens. Ensure pipette tips remain below the liquid level to ensure proper mixing. 15. Repeat steps 13 and 14 for additional sample vessels. 16. After addition of magnetic silica mixture to all sample vessels, start the extraction run. 17. Upon completion of run, remove sample vessel(s) from the instrument. If the extracted standards and NTC are not going to be used immediately, transfer into individual tubes to minimize chance of magnetic silica falling back into sample. Store the extracted DNA at 2 to 8ºC prior to use. Long-term storage of extracted samples at this temperature is not recommended. Keep extracted DNA on a cooler block while loading disc. B. REAL-TIME PCR INSTRUMENT SETUP 1. Refer to Integrated Cycler Operator Manual for details on how to configure the Integrated Cycler Studio Software to add an assay definition, establish a Standard Curve (Calibration Run), and analyze runs on the Integrated Cycler. Note: Only the Quantitation Standards and NTC may be loaded on the calibration run. Patient specimens and positive controls may be run after a valid calibration run has been established.

Standards Page 4 Example Disc Layout 1 2 3 A QS-1 QS-3 QS-5 B QS-1 QS-3 QS-5 C QS-1 QS-3 QS-5 D QS-1 QS-3 QS-5 E QS-2 QS-4 NTC F QS-2 QS-4 G QS-2 QS-4 H QS-2 QS-4 4 5 6 7 8 9 10 11 12 C. REAGENT PREPARATION AREA Dedicated area for preparation of Simplexa TM EBV assay reaction mix. 1. Thaw the Primer Mix and the Master Mix at room temperature (approximate range 18 to 25 C). Each kit component vial contains sufficient reagents for 50 reactions. Prior to each use, gently mix the Primer Mix and Master Mix kit components by inverting 6 to 8 times and briefly centrifuge to pull contents down to bottom of tube. 2. Prepare the required volume of the Reaction Mix in an appropriately sized polypropylene microcentrifuge tube by pipetting the volume of each component as indicated in the table below. Reaction Mix Volumes Reagent Reaction Mix Reaction Mix Volume / 1 reaction Volume / 24 reactions Simplexa Master Mix 4.0 µl 96 µl Simplexa EBV Primer Mix 1.0 µl 24 µl Total Volume 5.0 µl 120 µl 3. Gently mix the Reaction Mix by inversion or by pipetting 8 to 10 times. 4. Briefly centrifuge to pull contents down to bottom of tube. 5. Proceed to PCR setup. 6. Use the Reaction Mix within one hour of preparation. Store Reaction Mix at 2 to 8 C if PCR setup will not be performed immediately after the Reaction Mix is prepared. D. REAL TIME PCR AMPLIFICATION AREA Perform in a dedicated area for preparation of the 96-well Universal Disc for the Simplexa EBV assay. Refer to example disc layout in section B while performing the following setup: 1. Add 5.0 µl of the Reaction Mix to each well. 2. Add 5.0 µl of extracted quantitation standard to the appropriate QS well. 3. Add 5.0 µl of extracted No-Template Control to the NTC well. 4. Cover the disc with the Universal Disc Cover Tape. 5. Open the lid of the Integrated Cycler. 6. Place the sealed Universal Disc onto the platen. 7. Close the lid gently. 8. Click Run. 9. Click Start. E. STANDARD CURVE (CALIBRATION RUN) ANALYSIS 1. The Integrated Cycler Studio will automatically determine if a calibration run is valid. LIMITATIONS a. If valid, the calibration run will automatically be saved for use. b. If invalid, the calibration run will be discarded and a new calibration run must be performed before patient specimens can be tested. 1. For use with the Simplexa EBV kit. 2. Analysts should be trained and familiar with testing procedures and interpretation of results prior to performing the assay. 3. The Integrated Cycler Studio retains the last valid calibration run to quantify unknown patient specimens. The Quantitation Standards and the patient specimens must be extracted using the same extraction methodology or you will receive erroneous results.

Standards Page 5 REFERENCES 1. NCCLS H18-A2. Procedures for the Handling and Processing of Blood Specimens; Approved Guideline. 2nd Ed. (1999). 2. CDC-NIH Manual. (1999) Biosafety in Microbiological and Biomedical Laboratories. 4th ed. And National Committee for Clinical Laboratory Standards (NCCLS). Protection of Laboratory Workers from Instruments, Biohazards and Infectious Disease Transmitted by Blood, Body Fluids and Tissue (NCCLS M29-A). AUTHORIZED REPRESENTATIVE mdi Europa GmbH, Langenhagener Str. 71 30855, Langenhagen-Hannover, Germany ORDERING INFORMATION Telephone: Fax: (800) 838-4548 (U.S.A. only) (562) 240-6510 (562) 240-6500 (International) PI.MOL2410.OUS Rev. C Date written: 20-April-2012 TECHNICAL ASSISTANCE Telephone: (800) 838-4548 (U.S.A. only) Fax: (562) 240-6526 Visit our website at www.focusdx.com (562) 240-6500 (International) Cypress, California 90630 USA