SITE AND BUILDING NEW CONSTRUCTION FOR: BUSH'S CHICKEN RESTAURANT EXTERIOR COOLER/FREEZER PROTOTYPE. Contact Information:

Similar documents
Building Division Informational Handout

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

HOLDOWN & STRAP SCHEDULE

Pulaski County, Virginia Practical Wall Bracing

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

A Simple Solution for Meeting

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

GARAGE MAIN FLOOR PLAN

Accessory Structures- 430 Third Street Garages Farmington, MN (651) Information Sheet

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

GARAGE MAIN FLOOR PLAN

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Structural Training - Part 1:

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

GARAGE MAIN FLOOR PLAN

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

THE ASHTON PERSPECTIVE VIEW

GARAGE MAIN FLOOR PLAN

Wall bracing panel requirements

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

GARAGE MAIN FLOOR PLAN

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

Garage/Accessory Structures

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

THE CUNNINGHAM HOME PERSPECTIVE VIEW

POST AND FRAME STRUCTURES (Pole Barns)

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

POST AND FRAME STRUCTURES (Pole Barns)

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

ESR ICC Evaluation Service, Inc. Issued October 1, 2007 This report is subject to re-examination in one year.

Framing Methods Structural Components

14' x 24' Garage Plan

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHEAR WALL PANELS REPORT HOLDER: SIMPSON STRONG TIE COMPANY INC.

COMPANION FOR THE 2001

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Residential Housing Project Weed, CA

Version 2.1 IBS 2010 Special Resource Edition

Incl. Ft. In. SF Qty. Calcs Item Directions

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

RB104-09/10 R602.7, R (New), Table R (New), Figures R (1)-(2) (New)

TYPICAL BEARING WALL FRAMING

Z4 PRODUCT CATALOG

BARN MAIN FLOOR PLAN. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By SDS-CAD Specialized Design Systems 12'-0" 3'-0" 4'-0" 1'-6" 3'-0" 1'-6" 20'-0"

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

GARAGE MAIN FLOOR PLAN

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

1 & 2 Family Garage/Shed Permits City of Oshkosh Inspection Services Division

ACCESSORY STRUCTURES (Garages/Sheds) BUILDING AND ZONING REQUIREMENTS (REVISED 4/21/16)

Project Name: the candlelight. Project No. Scale: sewer line. water line 1 8"=1'-0"

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

Detached Residential Garage or Accessory Building ~ Includes Garage Conversion to Habitable Space ~

GARAGE MAIN FLOOR PLAN 1

GARAGE MAIN FLOOR PLAN 1

WALL CONSTRUCTION CHAPTER 6

Great Do you need it larger or would like to relocate windows and doors or do you need something completely different?

15/32" CDX PLY W/ RADIANT BARRIER (COMMON NAILS) 2X ROOF RAFTERS (SEE PAGE 2) R-30 BATT. INSUL / CLIMATE ZONES14 AND 16

Featuring Selection and Installation Information for Lateral Wind Loads

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

Calculated Quantities and Details

2012 IRC Wood Wall Bracing

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

GARAGE MAIN FLOOR PLAN

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

1¾" VERSA-LAM WESTERN HEAdER GuidE

Christensen Detached Garage

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

Administrative Changes

Stone and Masonry Veneer

GARAGE MAIN FLOOR PLAN SDSCAD Specialized Design Systems

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

POST FRAME BUILDING STANDARDS

2003 International Residential Building Code

Minimum required percentage of length of braced wall band on each storey 4

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Typical Single-Story Framing Section

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

NORTH CAROLINA BUILDING CODE COUNCIL 2012 NC Building, Fire, Fuel Gas and Residential Code Changes

S001 Structural General Notes and Legend

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

RUNNERS (Required to convert to real property)

front elevation right elevation

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Transcription:

SITE AND BUILDING NEW CONSTRUCTION FOR: RESPONSIBILITY MATRIX SCOPE ITEM PROVIDED BY: INSTALLED BY: REMARKS BUSH'S CHICKEN RESTAURANT EXTERIOR COOLER/FREEZER PROTOTYPE Contact Information: Architect: Mike Treadway, AIA Mike Treadway Architects, Inc. 2400 Augusta Dr. Suite 00 Houston, Texas 77057 o. 73.953.985 Structural Engineer: Eric Davis Eric L. Davis Engineering, Inc. 470 Shavano Oak, Suite 0 San Antonio, TX 78249 o. 20.408.709 MEP Engineer Rick Watson, PE Purtle + Associates, L.C. 944 Stevens Road, Suite 200 Shreveport, LA 706 o. 38.425.4500 Architects MTA Mike Treadway Architects, Inc Structural Engineers Eric L. Davis Engineering, Inc 08/22/206: ISSUED FOR PRICING MEP Engineers Purtle + Associates, L.C.

Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 Revision/Issues Copyright c 206 MTA EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 6 Copyright 2 8 4 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Floor Plan - Small Prototype A2.0

PREP AREA STORAGE THAW/ COOLER Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 COOLER FREEZER Revision/Issues Copyright c 206 MTA EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 20 6 2 Copyright 8 4 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Concrete Slab & Wall Curb Plan A2.02

2 8 4 Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 Revision/Issues Copyright c 206 206 MTA MTA MIKE INC. EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE PREP AREA STORAGE THAW/ COOLER COOLER FREEZER INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Furniture Plan & Occupant Load Analysis A2.03

Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 Revision/Issues INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Copyright c 206 206 MTA MTA MIKE INC. EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE Equipment Plan A2.04

Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 Revision/Issues Copyright c 206 206 MTA MTA MIKE INC. EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 20 2 8 4 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Reflected Ceiling Plan & Details A2.0

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 9 8 7 6 2 8 4 3 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Roof Plan & Details A2.20

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 2 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Exterior Elevations A3.0

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 2 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Exterior Elevations A3.02

Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 Revision/Issues Copyright c 206 MTA EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 20 9 7 6 5 2 9 8 7 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Enlarged Restroom Plan & Accessibility Notes A4.0

ROOM FINISH SCHEDULE Revision/Issues ROOM NUMBER ROOM NAME FLOOR BASE N WALLS E S W CEILING CLG. HT. REMARKS INTERIOR MATERIAL FINISH SCHEDULE FLOORS BASE WALLS CEILINGS 4 Copyright INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Copyright c 206 MTA TRIM / MISCELLANEOUS EXTERIOR MATERIAL FINISH SCHEDULE MARK MANUF / MODEL NO. DESCRIPTION LOCATIONS EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 7 3 2400 Augusta Drive, Suite 00 PH: 73-953-985 Houston, Texas 77057 FAX: 73-953-068 2 Room Finish Schedule & Partition Types 5 A5.0

DOOR SCHEDULE DOOR FRAME MARK SIZE (W x H x Th) TYPE TYPE HRDWR SET DETAILS - RE: A5.02 HEAD JAMB SILL REMARKS Revision/Issues 4 DOOR HARDWARE SCHEDULE HDWR SET LOCATION DESCRIPTION INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. 8 Copyright c 206 MTA 2400 Augusta Drive, Suite 00 PH: 73-953-985 Houston, Texas 77057 FAX: 73-953-068 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 7 3 6 2 Door & Window Schedules & Details 7 3 5 A5.02

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 20 8 4 3 2 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Wall Sections And Details A6.0

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 20 6 2 8 4 3 2 4 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Wall Sections And Details A6.02

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 3 2 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Wall Sections And Details A6.03

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 0 9 3 2 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Exterior Elevations A7.0

Revision/Issues Copyright c 206 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 EXTERIOR 2035 COOLER/FREEZER FM 529 ROAD PROTOTYPE 9 7 6 5 3 2 INCOMPLETE DOCUMENTS - FOR INTERIM REVIEW ONLY. THESE DOCUMENTS ARE NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION PURPOSES. Millwork Details A7.02

Revision/Issues STRAND MATERIAL LIST -0% Elongation +0% Qty. Strand Mark (in) (in) (in) S26 /6" 7/8" 2 /6" S37 2 7/6" 2 3/4" 3" S39 2 5/8" 2 7/8" 3 3/6" S40 2 /6" 2 5/6" 3 /4" 9 S43 2 3/6" 3 /8" 3 7/6" 0 S48 3 /4" 3 9/6" 3 5/6" S75 5 /8" 5 /6" 6 /4" S75 5 /6" 5 5/8" 6 3/6" 3 S77 5 /4" 5 7/8" 6 7/6" 8 S80 5 /2" 6 /6" 6 /6" 2 BS27 /6" 7/8" 2 /6" 2 BS38 2 7/6" 2 3/4" 3" 2 BS4 2 /6" 2 5/6" 3 /4" 6 BS44 2 3/6" 3 /8" 3 7/6" 8 BS49 3 /4" 3 9/6" 3 5/6" 2 BS52 3 7/6" 3 3/6" 4 3/6" 2 BS76 5 /8" 5 /6" 6 /4" 6 BS8 5 /2" 6 /6" 6 /6" Total Strand Quantity Total Strand Length 66 3640 EA FT CONCRETE CALCS. Slab Area Beam Depth Beam Volume Slab Volume Total Volume Total Volume (+5%) 3306 SF "VARIES" 52 CY 4 CY 93 CY 07 CY Copyright c 205 MTA 2400 Augusta Drive, Suite 00 PH: 73-953-985 Houston, Texas 77057 FAX: 73-953-068 2035 FM 529 ROAD Foundation Plan S.0

Revision/Issues Copyright c 205 MTA Houston, Texas 77057 FAX: 73-953-068 2400 Augusta Drive, Suite 00 PH: 73-953-985 2035 FM 529 ROAD S.02

Revision/Issues SYMBOL KEY SIMPSON STHD0 or HTT5 HOLDDOWN 2 CS6 STRAPPING, 3' MINIMUM LENGTH ATTACHED TO STUDS BOTH FLOORS BWL BRACED WALL PANEL - SEE DETAILS BRACED WALL LINE DASHED LINE INDICATES STRUCTURAL SHEATHING Copyright c 206 MTA BWL #2 BUSH'S CHICKEN 2035 FM 529 ROAD BWL # 2400 Augusta Drive, Suite 00 PH: 73-953-985 Houston, Texas 77057 FAX: 73-953-068 Shear Wall Plan ST ATE O F X TE AS BWL # BWL #2 BWL #3 P R O DONALD E. HERRERA F E S S R E G I 55045 I ON S A T E RE D L G E N E ER IN S.03

Revision/Issues GENERAL NOTES 6" TYP. 6" 6" TYP. CONTINUOUS STRUCTURAL SHEATHING ON ONE FACE WITH A MAXIMUM HEIGHT OF 0' U.N.O. NAILED WITH 8d NAILES @ 6" O.C. AT PANEL EDGES, 2" O.C. AT INTERIOR SUPPORTS. SECTION DETAIL N.T.S. DOUBLE TOP PLATE -/2" MIN. BLOCKING PANEL BLOCKING DETAIL SCALE: NTS SIMPSON H2.5A TIE LOCATED EVERY OTHER RAFTER TYP. 2X4 STUD RAFTER TO TOP PLATE DETAIL SCALE: NTS NAIL INTO BOTH TOP PLATES 2 x 4 STUDS MIN. HTT5 OR STHD0 2 HTT5 OR STHD0 SECTION DETAIL (EXTERIOR ELEVATION) N.T.S. 5/8" NUT WASHER VARIES 6" VARIES HTT5 OR STHD0 HOLDOWN ANCHOR TYPICAL (ONE STORY) 2'-8" TO 4'-0" LENGTH 7/6" OSB STRUCTURAL WOOD SHEATHING ON ONE FACE WITH A MAXIMUM HEIGHT OF 0'. NAILED PER 202 IBC TABLE 2304.9. AND BLOCKED AT ALL EDGES. TWO ANCHOR BOLTS OR 3" PINS AND WASHERS SET BY POWER ACTUATED TOOL SHALL BE INSTALLED AT QUARTER POINTS AS SHOWN. 2 SECTION DETAIL (PLAN VIEW) N.T.S. BCS2-2/4 BCS2-3/6 COLUMN HEIGHT FROM 8' TO 2' REQUIRES A MINIMUM EQUIVALENT OF 4"X4" LUMBER COLUMN HEIGHT FROM 2'-" TO 20' REQUIRES A MINIMUM EQUIVALENT OF 6"X6" LUMBER BASE PLATE ABU44 OR AB44 ABU66 OR AB66 2 x 4 STUDS MIN. 7/6" OSB SHEATHING ON EXTERIOR FACE NAILED WITH 8d NAILS @ 6" O.C. AT PANEL EDGES, 2" O.C. AT INTERIOR SUPPORTS FOR PANEL SPLICE (IF NEEDED) ADJOINING PANEL EDGES SHALL MEET OVER AND BE FASTENED TO COMMON FRAMING. MINIMUM REINFORCING OF FOUNDATION. ONE #4 BAR TOP AND BOTTOM OF FOOTING. REINFORCING SHALL BE LAPPED 5 INCHES. MINIMUM FOOTING SIZE UNDER OPENINGS 2"x2". A TURNED-DOWN SLAB SHALL BE PERMITTED AT DOOR OPENINGS. REINFORCING SHALL BE AS SHOWN ABOVE. MAX HEIGHT 0' X4 LET-IN BRACING DETAIL SCALE: NTS INSTALL CONTINUOUS "X4" WOOD OR APPROVED METAL STRAPPING AT MIN 45 TO MAX 60 DEGREES WITH TWO 8D NAILS AT EACH STUD, TOP AND BOTTOM PLATES. MAX STUD SPACING TO BE 6" O.C. STRUCTURAL SHEATHING NOTE: FOR EXTERIOR SHEAR WALL ANCHORING SEE GENERAL NOTE (5). INTERIOR: SEE GENERAL NOTE (9) OR MIN. 2 2" POWDER ACTUATED PINS AND WASHERS @ 24" O.C. IS CONSIDERED ONE OF THE FOLLOWING: MIN 7/6" OSB RED THERMOPLY BLUE THERMOPLY MIN. 3"x.25" NET HEADER 6' to 8' FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 6d SINKER NAILS @ 3" O.C. TYP. MSTC28 ON INTERIOR OF WALL MIN. 7/6" OSB SHEATHING ON EXTERIOR FACE NAILED WITH 8d NAILS @ 3" O.C. PROVIDE SIMPSON HTT5 HOLD DOWNS WITH 5/8" ATR ANCHORS SET WITH EPOXY AND 6" MIN. EMBEDMENT OR SIMPSON STHD0 INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. EXTENT OF HEADER (DOUBLE PORTAL FRAME) EXTENT OF HEADER (SINGLE PORTAL FRAME) ONE STORY: MIN WIDTH=6" FIRST OF TWO STORY: MIN WIDTH = 24" OR MIN WIDTH = 6" WITH FULL STRUCTURAL SHEATHING AT INTERIOR WALL DIRECTION OF STRENGTH AXIS MIN DBL STUDS. REFERENCE ARCHITECTURAL DRAWINGS FOR STUD SIZES AND DIMENSIONS. 2. ALL RAFTERS/LEDGERS, STUDS, HEADERS AND SHEATHING SHALL BE NAILED IN ACCORDANCE WITH THE 202 INTERNATIONAL BUILDING CODE TABLE 2304.9., UNLESS OTHERWISE NOTED. 3. SHEARWALL SEGMENTS SHALL BE CONTINUOUS FROM THE MUDSILL THROUGH THE DOUBLE TOP PLATE. 4. BRACE WALLS LESS THAN 2' IN WIDTH DO NOT REQUIRE BOLTS & WASHERS BETWEEN THE 2 INSTALLED HOLD DOWN STRAPS (HTT5/STHD0). PROVIDE -ANCHOR BOLT C/L OR 2-3" PINS AND WASHERS (SET @ /3 POINTS BY A POWDER ACTUATED TOOL) FOR BRACED WALLS FROM 2' TO 2'-8" OVERALL LENGTH. 5. MUDSILL AT ALL EXTERIOR WALLS SHALL BE ANCHORED TO THE FOUNDATION SLAB WITH /2" ANCHOR BOLTS EMBEDDED 7" INTO THE SLAB AND SPACED 6'-0" O.C. MAX. OR SIMPSON STRONG-TIE MASA MUDSILL ANCHORS @ 6'-0" O.C.. 6. WHERE RAFTERS MEET THE TOP PLATE OF EXTERIOR WALLS, INSTALL SIMPSON STRONG-TIE H2.5 ANCHORS AT EVERY OTHER RAFTER. ANCHORS WITH 445 LB. CAPACITY OR GREATER MAY BE USED AS AN ALTERNATE. 7. ALL INTERIOR WALLS TO BE /2" SHEETROCK NAILED PER TABLE 2304.9. OF THE 202 IBC. 8. LET-IN BRACING MAY BE SUBSTITUTED WITH 4X8 STRUCTURAL SHEATHING (RED T-PLY OR OSB) FROM TOP TO BOTTOM PLATE OR CS6 X-BRACING. 9. ALL INTERIOR BRACED WALLS MUST BE ANCHORED TO THE FOUNDATION USING SIMPSON TITEN HD /2" ANCHOR BOLTS OR APPROVED EQUAL. 9.. INSTALL TITEN HD ANCHOR BOLTS AT MAXIMUM SIX FEET ON CENTER, WITH MINIMUM 2-3/4" EMBEDMENT INTO FOUNDATION. 9.2. MINIMUM TWO BOLTS PER BRACED WALL SECTION, WITH ONE BOLT LOCATED NOT MORE THAN 2" OR LESS THAN SEVEN BOLT DIAMETERS FROM EACH END OF BRACED WALL SECTION. NOTE: SIMPSON STHD0 NOTE: ALL SIMPSON PRODUCTS OR HTT5 CAN BE MAY BE SUBSTITUTED WITH APPROVED EQUAL TYP. PORTAL FRAME CONSTRUCTION FOR PANEL SPLICE (IF NEEDED), PANEL EDGES SHALL BE BLOCKED, AND OCCUR WITHIN 24" OF MID-HEIGHT. ONE ROW OF TYP. SHEATHING-TO- FRAMING NAILING IS REQ. IF 2x BLOCKING IS USED, THE 2x's MUST BE NAILED TOGETHER WITH (3) 6d SINKERS Copyright c 206 MTA 2400 Augusta Drive, Suite 00 PH: 73-953-985 Houston, Texas 77057 FAX: 73-953-068 BUSH'S CHICKEN 2035 FM 529 ROAD Shear Wall Notes CONTINUOUS SHEATHING ACROSS TOP AND BOTTOM PLATES. SPACING AS REQUIRED FOR SHEARWALL PANEL EDGES. PANEL CONNECTION DETAIL AT FIRST & SECOND FLOORS SCALE: NTS EXISTING FOUNDATION SCALE: NTS 5/8" ANCHOR BOLT EMBEDDED 6" INTO FOUNDATION. EPOXY ALLYHREAD, WEDGE-ALL OR TIGHTEN HD STANDARD COLUMN DETAIL 4 PORTAL FRAME (SINGLE AND DOUBLE) N.T.S. 55045 P R O ST O S A F X DONALD E. HERRERA F E S S ATE R E G I I ON T E RE D L TE AS G E N E ER IN S.04

Revision/Issues Copyright c 206 MTA BUSH'S CHICKEN 2035 FM 529 ROAD 2400 Augusta Drive, Suite 00 PH: 73-953-985 Houston, Texas 77057 FAX: 73-953-068 Ceiling and Roof Plan ST ATE O F X TE AS P R O DONALD E. HERRERA F E S S R E G I 55045 I ON S A T E RE D L G E N E ER IN S.05