Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

Similar documents
SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL FRAMING

STRUCTURAL STEEL FRAMING

DIVISION 5 METALS SECTION STRUCTURAL STEEL

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

STRUCTURAL STEEL FRAMING Section

SECTION STRUCTURAL METAL FRAMING

SECTION STRUCTURAL STEEL

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

SECTION COLD-FORMED METAL TRUSSES

SECTION STEEL JOIST FRAMING

Commission No Section

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

SECTION METAL STAIRS

2. Clarification: The notice to proceed construction period of 60 days will begin after the Contractor receives all materials and equipment.

C. Miscellaneous Metal Fabricators are specified elsewhere in Division 5.

UC Denver Guidelines and Design Standards SECTION STRUCTURAL METAL FRAMING

.2 Section Waste Management and Disposal.

SECTION STRUCTURAL STEEL

D I V I S I O N 05: M E T A L S

1.02 SYSTEM DESCRIPTION

SECTION METAL STAIRS

SUNY GENESEO RED JACKET DINING HALL RENOVATION SECTION STRUCTURAL STEEL FRAMING

Special Provision No. 915S03 December References, Materials, Construction, and Quality Assurance for Sign Support Structures

SECTION METAL WELDING

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

Mezzanines By Design Page 1

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces

JONES AIRWAY, LLC CLEVELAND REGIONAL JETPORT SECTION STRUCTURAL STEEL

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

1.02 SYSTEM DESCRIPTION

SPECIAL INSPECTION AGREEMENT

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION COMPOSITE METAL DECKING

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

A. American Society for Testing and Materials (ASTM):

A. Structural Steel: Elements of structural-steel frame, as classified by AISC 303, "Code of Standard Practice for Steel Buildings and Bridges.

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

ITEM 442 METALS FOR STRUCTURES

Tnemec 394 Proprietary Long Form Coatings Schedule

SECTION STRUCTURAL STEEL

PROJECT: 4/30/14 DATE: REVISIONS: 6/10/14 7/28/14 11/3/14 11/12/14 11/14/14 OF 6

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

SECTION METAL FABRICATIONS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

A. Product Data: For each type of cold-formed steel framing product and accessory.

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION MISCELLANEOUS METALS

SECTION 2 DIVISION 05 METALS

SECTION ALTERNATING TREAD STEEL STAIRS

Item 442 Metal for Structures

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

SECTION HANGERS AND SUPPORTS PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 2

UNIFIED FACILITIES GUIDE SPECIFICATIONS

. SECTION HANGERS AND SUPPORTS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

STATEMENT OF SPECIAL INSPECTION FORM

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

SECTION 15 STRUCTURAL STEEL

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION METAL BUILDING SYSTEMS

SECTION COLD-FORMED METAL FRAMING

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 2

SECTION CASTELLATED or CELLULAR STRUCTURAL STEEL BEAMS

1. Cast-in-place concrete is specified in Section

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS

Report of Special Inspections

SECTION (05300) - STEEL DECKING

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Statement of Special Inspections 2013 CBC

SECTION PREFABRICATED PIPE BRIDGE(s)

DIVISION: METALS SECTION: STRUCTURAL STEEL FRAMING REPORT HOLDER: CAST CONNEX CORPORATION

Statement of Special Inspection Requirements

SECTION DECORATIVE METAL RAILINGS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

SECTION LATCHWAYS CONSTANT FORCE POSTS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Transcription:

SECTION 05120 STRUCTURAL STEEL PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03342 - Insulating Cellular Concrete. 2. 05210 - Steel Joists. 3. 09900 - Painting. 1.02 REFERENCES A. America Society for Testing and Materials (ASTM): 1. A36/A-96 Specification for Carbon Structural Steel. 2. A53-96 Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless. 3. A123-89a Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products. 4. A307-94 Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength. 5. A325-96 Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength. 6. A385-80(96) Practice for Providing High Quality Zinc Coatings (Hot Dip). 7. A490-93 Specification for Heat-Treated Steel Structural Bolts, 150 ksi Minimum Tensile Strength. 8. A500-93 Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes. 9. A501-93 Specification for Hot-Formed Welded and Seamless Carbon Steel Structural Tubing. 1.03 QUALITY ASSURANCE A. Standard Building Code, 1994 with 1996 revisions. B. American Institute of Steel Construction, Inc., (AISC): Manual of Steel Construction, Eighth Edition. 1. Specification for Design, Fabrication and Erection of Buildings. 2. Code of Standard Practice for Steel Buildings and Project No. SPECIFICATION GUIDELINES 05120-1

Bridges. 3. Structural Joints Using ASTM A325 or ASTM A490. C. American Welding Society (AWS); Structural Welding Code, AWS D1.1. D. Steel Structures Painting Council (SSPC). E. Where requirements of AWS are in conflict with requirements of AISC, requirements of AISC shall take precedence. 1.04 SUBMITTALS A. Submit both shop and erection drawings with indexes for structural steel for review before starting work. PART 2 PRODUCTS 2.01 MATERIALS A. Rolled Shapes and Plates: ASTM A36. B. Anchor Bolts: ASTM A307, with regular series hexagonal head nuts, unless otherwise specified, hot dipped galvanized where noted. C. Nuts and Bolts Except Anchor Bolts: ASTM A325, washers as required. Bolts connecting galvanized members shall also be galvanized. D. Electrodes: E70 or F7 Series, as appropriate. E. Shop Paint: Manufacturer's standard, compatible with finish coats. Refer to Section 09900. F. Structural Tubing: ASTM A500, Grade B, Fy=46KSI. G. Pipe: ASTM A501, Fy=36 ksi or ASTM A53, type E or S, Grade B, Fy=35 ksi. PART 3 EXECUTION 3.01 INSPECTION A. Do not proceed with the work of this section until conditions detrimental to the proper and timely completion of the work have been corrected in an acceptable manner. 3.02 INSTALLATION Project No. SPECIFICATION GUIDELINES 05120-2

A. Unless otherwise specified, comply with AISC specifications and "Standards" for fabrication and erection. B. Connections: 1. Shop connections shall be welded or bolted at the option of the Contractor, unless otherwise indicated. 2. Field connections shall be bolted except where specifically indicated to be welded. Field moment connections may be welded. 3. Bolts shall be ASTM A325, friction type, unless otherwise indicated. 4. Connections shall be as generally indicated where the complete connection is shown. 5. Connections not detailed will be designed by the Contractor for the controlling stresses indicated using AISC requirements. 6. Minimum connection is two 3/4" diameter ASTM A325, bolts or equivalent in weld, (15.5K). 7. For framed connections in non-composite construction and for beams without concentrated loads, where reactions are not indicated, design the connection for one-half of the total uniform load capacity of the beam shown in "Tables for Allowable Loads on Beams", AISC. 8. Where moment connection or continuous framing is indicated, design connections for the moment indicated, but not less than 50 percent of the moment capacity, however, where the design moment is not given, design the connection for 100 percent of the moment capacity. Moment connections shall be Type 1, rigid frame. 9. Columns shall be detailed as indicated, bearing surfaces shall be finished (planed). 10. Moment connections, shop or field, shall not have bolts through the top flange plates to avoid interference with the metal decking. 11. Stiffened seats, unless indicated, are not allowed unless the Contractor verifies architectural clearances are maintained and interferences with any elements of the building will not occur. C. Shop Cleaning: Clean steel to the requirements of SSPC-SP2. D. Shop Painting: Shop paint steel except steel intended to be encased in concrete and steel to be hot dipped galvanized. E. Erection Marks: 1. Column marks shall be the column number assigned on the structural drawings supplemented by tier or level Project No. SPECIFICATION GUIDELINES 05120-3

number. 2. Beam marks shall be prefixed by floor or level number. F. Hot Dip Galvanize After Fabrication: According to ASTM A123, ASTM A385, and ASTM A123, all steel exposed to the weather, namely. Erect those members with galvanized ASTM A325 bolts. Seal weld all members to be hot dipped galvanized. G. Camber: Shop or mill camber beams indicated. 3.03 TESTING A. The Board may elect to inspect work in shop or field or both by nondestructive means as specified. 1. Contractor shall make no claim for extra work or delay using as a basis the inspection of work by the Board. B. Welding Inspection: 1. Inspector designated by the Board will assume the duties and responsibilities of "Inspector" specified in Chapter Six of AWS D1.1-79. 2. Acceptance Criteria: a. Visual: AWS D1/1, Para.3.7 and 8.15. b. Radiographic, Ultrasonic, Magnetic Particle, and Dye Penetrant: AWS D1.1, Para.8.15. c. Where more than one type of testing is used, acceptance criteria is "passing" all testing procedures used. 3. Inspector will spot inspect by ultrasonic means, 100 percent (one spot per weld) of all tension groove welds and 50 percent of all compression groove welds shop and field. a. Where metal thickness is less than 5/16", radiographic spot testing will be used. 4. Inspector will inspect welds by visual rules. 5. Inspector may use radiographic means where ultrasonic testing is not feasible. 6. Inspector may supplement any testing with dye penetrate, magnetic, radiographic, or ultrasonic plans. 7. Contractor shall be responsible for associated costs of inspections including handling, surface preparation and repair of discontinuities. Project No. SPECIFICATION GUIDELINES 05120-4

C. Provide ladders or other appropriate means for inspecting personnel to properly gain access to field joints. D. Bolting Inspection: Inspector will test bolts both in the shop and in the field by methods specified in "Structural Joints Using ASTM A325 or ASTM A490 Bolts". END OF SECTION Project No. SPECIFICATION GUIDELINES 05120-5