COMPLETE REVISION February Process Industry Practices Structural. PIP STS05130 Structural and Miscellaneous Steel Erection Specification

Similar documents
PIP STF05501 Fixed Ladders Fabrication Details

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

COMPLETE REVISION November Process Industry Practices Structural. PIP STF05530 Grating Fabrication Details

SECTION STRUCTURAL METAL FRAMING

PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces

Mezzanines By Design Page 1

SECTION STRUCTURAL STEEL FRAMING

DIVISION 5 METALS SECTION STRUCTURAL STEEL

JONES AIRWAY, LLC CLEVELAND REGIONAL JETPORT SECTION STRUCTURAL STEEL

COMPLETE REVISION September Process Industry Practices Piping. PIP PNSM0120 Purchasing Requirements for Bolting

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

SECTION STRUCTURAL STEEL

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

PIP STF05511 Fixed Industrial Stairs

STRUCTURAL STEEL FRAMING

PIP STE05501 Fixed Ladders and Cages Design Guide

SECTION STRUCTURAL STEEL

A. Structural Steel: Elements of structural-steel frame, as classified by AISC 303, "Code of Standard Practice for Steel Buildings and Bridges.

COMPLETE REVISION November Process Industry Practices Architectural. PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

SECTION COLD-FORMED METAL TRUSSES

COMPLETE REVISION February Process Industry Practices Structural. PIP STS05120 Structural and Miscellaneous Steel Fabrication Specification

SUNY GENESEO RED JACKET DINING HALL RENOVATION SECTION STRUCTURAL STEEL FRAMING

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

SECTION STRUCTURAL STEEL FRAMING

COMPLETE REVISION October Process Industry Practices Piping. PIP PNSC0036 High Density Polyethylene (HDPE) Piping Installation Specification

STRUCTURAL STEEL FRAMING Section

SECTION STRUCTURAL STEEL

PIP PNSM0115 Purchasing Requirements for Pipe

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

COMPLETE REVISION June Process Industry Practices Architectural. PIP ARS08390 Blast Resistant Doors, Frames, and Related Hardware Specification

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

PIP RFTF1000 Ceramic Fiber Refractory Installation Qualification, Inspection, and Testing

C. Miscellaneous Metal Fabricators are specified elsewhere in Division 5.

Tnemec 394 Proprietary Long Form Coatings Schedule

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

Commission No Section

PIP RFTA1000 Refractory Anchor and Accessory Installation Qualification, Inspection, and Testing

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

PIP RFTB1000 Brick Refractory Installation Qualification, Inspection, and Testing

Report of Special Inspections

SECTION STRUCTURAL STEEL

SECTION PREFABRICATED PIPE BRIDGE(s)

STANDARD SPECIFICATION FOR ALUMINUM FRAMING FOR RAILROAD PASSENGER SHELTERS

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

SECTION MISCELLANEOUS METAL FABRICATIONS

SECTION COLD-FORMED METAL FRAMING

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

DOUGLAS ELEMENTARY SCHOOL STRUCTURAL STEEL FRAMING

B. Maintain a direct channel of communication with the Engineer, and keep the General Contractor informed of the subject of such communication.

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

1.02 SYSTEM DESCRIPTION

SECTION STRUCTURE MOUNT RAILING SYSTEM

SECTION STEEL JOIST FRAMING

SECTION TIMBER FLOATS

DIVISION 5 METALS SECTION METAL DECKING

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

Statement of Special Inspection Requirements

SECTION COLD-FORMED METAL FRAMING

SECTION STRUCTURAL STEEL FRAMING

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

PIP VESSP002 Supplemental Design and Fabrication Specification for Shell and Plate Heat Exchangers ASME Code Section VIII, Divisions 1 and 2

.2 Section Waste Management and Disposal.

SECTION CASTELLATED or CELLULAR STRUCTURAL STEEL BEAMS

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

PREFABRICATED STEEL TRUSS SPECIFICATIONS

SECTION COMPOSITE METAL DECKING

EDITORIAL REVISION January Process Industry Practices Vessels. PIP VEFV1100M Vessel/S&T Heat Exchanger Standard Details (Metric Units)

PIP PNC00001 Pipe Support Criteria for ASME B31.3 Metallic Piping

SPECIAL INSPECTION AGREEMENT

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION CANOPIES. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

March Process Industry Practices Refractory. PIP RFIA1000 Refractory Anchor and Accessory Installation Details

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION COLD-FORMED METAL FRAMING

Tnemec 394 Public Bid Long Form Specification

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

Pipeline Systems PIP PLSC0013 Non-Destructive Examination of ASME B31.4 and B31.8 Metallic Pipelines

SECTION INSTALLATION OF OWNER-FURNISHED PRODUCTS

SECTION STRUCTURAL STEEL

PIP VEFV1100 Vessel/S&T Heat Exchanger Standard Details (U.S. Customary Units)

SECTION COMPOSITE METAL DECKING

LAGUARDIA COMMUNITY COLLEGE - CUNY August 3, 2009

SECTION METAL STAIRS

PIP VEFV1100 Vessel/S&T Heat Exchanger Standard Details (U.S. Customary Units)

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION ALTERNATING TREAD STEEL STAIRS

Transcription:

COMPLETE REVISION February 2011 Structural PIP STS05130 Structural and Miscellaneous Steel Erection Specification

PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical requirements in the existing standards of major industrial users, contractors, or standards organizations. By harmonizing these technical requirements into a single set of Practices, administrative, application, and engineering costs to both the purchaser and the manufacturer should be reduced. While this Practice is expected to incorporate the majority of requirements of most users, individual applications may involve requirements that will be appended to and take precedence over this Practice. Determinations concerning fitness for purpose and particular matters or application of the Practice to particular project or engineering situations should not be made solely on information contained in these materials. The use of trade names from time to time should not be viewed as an expression of preference but rather recognized as normal usage in the trade. Other brands having the same specifications are equally correct and may be substituted for those named. All Practices or guidelines are intended to be consistent with applicable laws and regulations including OSHA requirements. To the extent these Practices or guidelines should conflict with OSHA or other applicable laws or regulations, such laws or regulations must be followed. Consult an appropriate professional before applying or acting on any material contained in or suggested by the Practice. This Practice is subject to revision at any time. (PIP), Construction Industry Institute, The University of Texas at Austin, 3925 West Braker Lane (R4500), Austin, Texas 78759. PIP Member Companies and Subscribers may copy this Practice for their internal use. Changes or modifications of any kind are not permitted within any PIP Practice without the express written authorization of PIP. Authorized Users may attach addenda or overlays to clearly indicate modifications or exceptions to specific sections of PIP Practices. Authorized Users may provide their clients, suppliers and contractors with copies of the Practice solely for Authorized Users purposes. These purposes include but are not limited to the procurement process (e.g., as attachments to requests for quotation/ purchase orders or requests for proposals/contracts) and preparation and issue of design engineering deliverables for use on a specific project by Authorized User s client. PIP s copyright notices must be clearly indicated and unequivocally incorporated in documents where an Authorized User desires to provide any third party with copies of the Practice. PRINTING HISTORY November 1994 Issued December 1998 Revision February 2002 Technical Correction February 2011 Complete Revision Not printed with State funds

COMPLETE REVISION February 2011 Structural PIP STS05130 Structural and Miscellaneous Steel Erection Specification Table of Contents 1. Introduction... 2 1.1 Purpose... 2 1.2 Scope... 2 2. References... 2 2.1... 2 2.2 Industry Codes and Standards... 2 2.3 Government Regulations... 3 3. Definitions... 3 4. Requirements... 4 4.1 General... 4 4.2 Products and Materials... 6 4.3 Execution... 6 Drawing STS05130-01 Field Located and Field Fabricated Grating Openings Page 1 of 10

PIP STS05130 COMPLETE REVISION Structural and Miscellaneous Steel Erection Specification February 2011 1. Introduction 1.1 Purpose This Practice provides the requirements for structural and miscellaneous steel erection. 1.2 Scope 2. References This Practice describes the requirements for the receipt, handling, erection, assembly, and field inspection of structural and miscellaneous steel. Structural and miscellaneous steel are as defined in AISC Code of Standard Practice. Applicable parts of the following Practices, industry codes and standards, and references shall be considered an integral part of this Practice. The edition in effect on the date of contract award shall be used, except as otherwise noted. Short titles are used herein where appropriate. 2.1 (PIP) PIP STS03600 - Cementitious Grout Specification PIP STS03601 - Epoxy Grout Specification PIP STS05120 - Structural and Miscellaneous Steel Fabrication Specification 2.2 Industry Codes and Standards American Institute of Steel Construction (AISC) AISC 303 - Code of Standard Practice for Steel Buildings and Bridges ANSI/AISC 360 - Specification for Structural Steel Buildings AISC Steel Construction Manual American Society of Safety Engineers (ASSE) ASSE A10.13 - Safety Requirements for Steel Erection American National Standard for Construction and Demolition Operations American Welding Society (AWS) AWS D1.1/D1.1M - Structural Welding Code Steel ASTM International (ASTM) ASTM A307 - Standard Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength ASTM A325 - Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength (AASHTO No. M164) ASTM A325M - Standard Specification for Structural Bolts, Steel, Heat Treated 830 MPa Minimum Tensile Strength (Metric) ASTM A490 - Standard Specification for Structural Bolts, Alloy Steel, Heat Treated, 150 ksi Minimum Tensile Strength (AASHTO No. M253) ASTM A490M - Standard Specification for High-Strength Steel Bolts, Classes 10.9 and 10.9.3, for Structural Steel Joints (Metric) Page 2 of 10

COMPLETE REVISION February 2011 PIP STS05130 Structural and Miscellaneous Steel Erection Specification Research Council on Structural Connections (RCSC) RCSC Specification for Structural Joints Using ASTM A325 or A490 Bolts Steel Deck Institute (SDI) SDI Design Manual for Composite Decks, Form Decks and Roof Decks Steel Joist Institute (SJI) SJI Standard Specifications and Load Tables 2.3 Government Regulations 3. Definitions Requirements by state or local agencies that have jurisdiction where the structural steel is to be erected, shall apply. U.S. Department of Labor, Occupational Safety and Health Administration (OSHA) OSHA 29 CFR Part 1910 OSHA 29 CFR Part 1926 contract documents: Any and all documents, including codes, studies, design drawings, specifications, sketches, practices, and data sheets, that the purchaser or engineer of record has transmitted or otherwise communicated, either by incorporation or reference, and made part of the legal contract agreement or purchase order between the purchaser and the erector. engineer of record: Purchaser s authorized representative with overall authority and responsibility for the engineering design, quality, and performance of the civil works, structure, foundations, materials, and appurtenances described in the contract documents. The engineer of record shall be licensed as defined by the laws of the locality in which the work is to be constructed, and be qualified to practice in the specialty discipline required for the work described in the contract documents. Also known as structural engineer of record in AISC Code of Standard Practice. erector: The party responsible for erecting structural and miscellaneous steel in accordance with the contract documents. The term erector shall apply also to the fabricator s subcontractor(s) and/or vendor(s). inspector: The party responsible for verifying the quality of all materials, installations, and workmanship furnished by the erector. The inspector shall be qualified by training and experience and hold certifications or documentation of their qualifications. Unless otherwise specified in the contract documents, the inspector shall be retained by the erector. manufacturer: The party who produces and warrants the performance of the products, materials, and/or items provided in accordance with the contract documents. The products, materials, and/or items are manufactured in a controlled process using standard codes, specifications, tests and possibly include shop drawings to assist in proper application, installation and/or use. The term manufacturer shall apply also to the manufacturer s subcontractor(s) and/or vendor(s). owner: The party who owns the facility wherein the structural steel will be used. Page 3 of 10

PIP STS05130 COMPLETE REVISION Structural and Miscellaneous Steel Erection Specification February 2011 professional engineer: An engineer, other than the engineer of record licensed as defined by the laws of the locality in which the steel is to be erected, and qualified to practice in the specialty discipline required for the work described in the contract documents. purchaser: The party who awards the contract to the erector. The purchaser may be the owner or the owner s authorized agent. 4. Requirements 4.1 General 4.1.1 Quality Control 4.1.1.1 Unless approved by the engineer of record, erector shall participate in the AISC Certification Program and be designated an AISC Certified Erector, Category ACSE. 4.1.1.2 The erector shall be solely responsible for the quality control of all the erector-supplied materials, installations, and workmanship. 4.1.1.3 A written Quality Control Program and Inspection Procedures document that shall provide details of how compliance with the requirements of this Practice and the shop and erection drawings shall be achieved, shall be provided. 4.1.1.4 A complete up-to-date set of erection drawings at the jobsite shall be maintained. 4.1.1.5 Bolted connections shall be installed and inspected in accordance with the RCSC Specification for Structural Joints Using ASTM A325 and A490 Bolts. 4.1.1.6 Welding procedures and individual welders shall be qualified in accordance with the requirements of AWS D1.1. 4.1.1.7 All welding shall be inspected in accordance with AWS D1.1. Inspectors shall be qualified and certified as AWS Certified Welding Inspectors in accordance with the provisions of AWS D1.1 or AWS QC1 or shall be trained by and working under the supervision of an AWS Certified Welding Inspector. 4.1.1.8 The inspector shall inspect all materials, installations, and workmanship to ensure conformance with all requirements of this Practice and the contract documents. 4.1.1.9 The purchaser shall have the right to inspect all materials, installations, and workmanship and shall have an unrestricted right of access to the work areas. 4.1.1.10 The purchaser may reject any improper, inferior, defective, or unsuitable materials, installations, and workmanship. 4.1.1.11 Rejected materials, installations, and workmanship shall be repaired or replaced in accordance with the purchaser s instructions at no cost to the purchaser. Page 4 of 10

COMPLETE REVISION February 2011 PIP STS05130 Structural and Miscellaneous Steel Erection Specification 4.1.1.12 Inspection tools and tool calibration records for tools used shall be maintained and available for examination by the purchaser. 4.1.2 Submittals 4.1.2.1 The following items shall be submitted to the engineer of record for approval. Work shall not proceed without approval. a. Safety program b. Quality control program and inspection procedures c. Welding Procedure Specification (WPS) d. Procedure Qualification Records (PQR) e. Welder(s) qualification records f. Assembly lift plan(s) as required by the purchaser or OSHA 29 CFR Part 1926 Subpart R 4.1.2.2 If requested, the following documents shall be submitted to the purchaser for recording purposes: a. Quality control inspections and test results b. Calibration or recalibration performed on the tools or equipment used during the work 4.1.3 Performance Requirements 4.1.3.1 Safety 1. A written safety program shall be provided that addresses the safety measures that shall be used during steel erection work. 2. The safety program shall be in accordance with the requirements of: a. The contract documents b. AISC Code of Standard Practice for Structural Steel Buildings and Bridges (AISC 303) c. Applicable portions of OSHA 29 CFR Part 1910 and Part 1926 d. Any other applicable federal, state, or local requirements 4.1.3.2 Assembly Lift Plan The erector shall be responsible for assuring that all preassemblies that are not specifically shown or noted on the design drawings to be preassembled before lifting shall maintain structural integrity during lifting. 1. A written assembly lift plan, prepared by a professional engineer, shall be provided for assemblies larger than 50 feet (15 meters) in one direction, larger than 2,000 square feet (186 square meters) in the plan area, greater than 50 tons (45 metric tons), or if required by the contract documents. Page 5 of 10

PIP STS05130 COMPLETE REVISION Structural and Miscellaneous Steel Erection Specification February 2011 4.2 Products and Materials 2. The assembly lift plan shall demonstrate that the proposed lift shall be performed safely and that the assemblies being lifted shall remain free from distortion or undue bending, and maintain structural integrity during the lift. 3. The assembly lift plan shall contain detailed data on the extent of the lifted assembly, its weights, the structural calculations that prove structural stability of the assembled components during lifting operations, verification of the capacity capabilities for any cranes utilized in the lift, location and positioning of the cranes, and a description of the rigging to be utilized. 4. Review of the assembly lift plan by the purchaser does not relieve the erector s responsibility for the safe erection and/or lifting of any component, structural assembly, or any other item. Unless otherwise specified, all materials shall be in accordance with PIP STS05120. 4.3 Execution 4.3.1 Receiving, Inspection, and Storage 4.3.1.1 All materials shall be received, unloaded, stored, and otherwise handled in a manner that prevents distortion, deterioration, damage, or staining. 4.3.1.2 Materials shall be kept free of dirt, grease, and other foreign matter. 4.3.1.3 Unless otherwise specified, all materials shall be inspected immediately after receipt to ensure that the materials are not damaged, that all items on the packing list have been supplied, and that all documentation has been received. 4.3.1.4 If any damage is discovered, or any parts, components, or documentation are missing or otherwise defective, the occurrence shall be immediately reported to the purchaser in writing. 4.3.2 Erection 4.3.2.1 Erection of structural steel shall be in accordance with: a. The drawings and other contract documents b. AISC Code of Standard Practice for Structural Steel Buildings and Bridges (AISC 303) c. OSHA 29 CFR Part 1910 and Part 1926 d. Applicable state, municipal, or local regulations or codes 4.3.2.2 Any circumstances discovered that affect progression, performance, or completion of the work activities shall be immediately reported to the purchaser in writing. These may Page 6 of 10

COMPLETE REVISION February 2011 PIP STS05130 Structural and Miscellaneous Steel Erection Specification include, but are not limited to, discrepancies between the erection/shop drawings and the delivered steel members, incorrectly fabricated steel members, or incomplete or unacceptable work of other contractors affecting the work. 4.3.2.3 Any damage caused during erection shall be reported to the purchaser in writing. Corrective measures shall be completed as directed by the purchaser at no cost to the purchaser. 4.3.2.4 Erection of steel joists shall be in accordance with: a. The requirements of the Steel Joist Institute (SJI) b. The joist manufacturer c. OSHA 29 CFR 1926 Subpart R 4.3.2.5 Temporary erection loads or permanent loads shall not be placed on any incomplete portions of the structure being erected unless it can be demonstrated by analysis that the contemplated action is safe. 4.3.2.6 Loose timbers, metal sheeting, bolt buckles, tools, debris, and temporary scaffolding shall be kept restrained or removed from work areas. 4.3.2.7 Lifting of painted or galvanized structural members shall be performed with a nonabrasive choker. 4.3.2.8 A daily record, by piece number, of all material erected shall be maintained. 4.3.2.9 Before commencing work, the foundations and other connection points shall be checked to confirm their location, orientation, elevation, and condition. 4.3.2.10 Erection of steel deck shall be in accordance with: a. The requirements of the Steel Deck Institute (SDI) b. The deck manufacturer c. OSHA 29 CFR 1926 Subpart R 4.3.2.11 Where connecting to existing structures, protect existing structure from weather. 4.3.3 Structural Stability 4.3.3.1 During construction, the erector shall be responsible for maintaining the structure in a stable condition; ensuring that no part shall be overstressed during construction activities. It shall be the erector s responsibility to specify, install and locate all temporary bracing and/or guy cables to maintain the partassembled structure in a stable condition under a combination of construction and wind loads. This responsibility shall also extend to temporary bracing required to ensure safe and stable conditions of partially completed structural assemblies. Page 7 of 10

PIP STS05130 COMPLETE REVISION Structural and Miscellaneous Steel Erection Specification February 2011 4.3.3.2 The structure shall be plumbed, leveled, and braced before any final bolted or welded connections are made and before grouting of base plates. 4.3.4 Setting Base Plates 4.3.4.1 The top of bearing surfaces and the bottom of base plates shall be cleaned. 4.3.4.2 The column base plates shall be set and shimmed to correct positions, elevations, and locations as shown on the erection drawings. 4.3.4.3 Shims or wedges shall be provided where required. 4.3.4.4 If setting nuts are used, they shall be loosened before grouting. 4.3.4.5 Unless otherwise specified in the contract documents, base plates shall be grouted in accordance with PIP STS03600 or PIP STS03601. Grout shall fill any anchor bolt sleeves and/or shear key openings. Cut off exposed edges of grout at 45 degrees along the edges of base plates after grout has acquired its initial set. 4.3.4.6 If required in the contract documents, anchor bolts shall be tightened to the specified tension. 4.3.4.7 Anchor bolts shall be fully tightened to the specified tension only after the base plates have been grouted and the grout has sufficiently set in accordance with manufacturer s recommendations. 4.3.5 Bolted Connections 4.3.5.1 If structural joints are made using high-strength bolt assemblies, the materials, methods of installation, tension control, types of wrenches to be used, and inspection methods shall be in accordance with the RCSC Specification for Structural Joints Using ASTM A325 and A490 Bolts and the contract documents. 4.3.5.2 If used, direct tension indicator (DTI) washers shall be installed according to the washer manufacturer s published specifications. 4.3.5.3 All bolts shall be as noted on the shop drawings, erection drawings, or other contract documents. 4.3.5.4 Mechanically galvanized bolts and nuts shall not be intermixed with hot-dip galvanized nuts and bolts. 4.3.5.5 If ASTM A307 bolt assemblies are used for connecting appurtenances (i.e., handrail assemblies, pipe supports, gates, etc.) to structural steel members, the bolts shall be tightened to a snugtight condition. 4.3.5.6 ASTM A490/A490M bolts and galvanized ASTM A325/A325M bolts shall not be reused. Page 8 of 10

COMPLETE REVISION February 2011 PIP STS05130 Structural and Miscellaneous Steel Erection Specification 4.3.5.7 Bolts that have been pretensioned shall be color coded, die punched, or otherwise marked on the ends indicating that the bolts have been properly tensioned and are ready for inspection. 4.3.6 Welded Connections 4.3.6.1 All welding shall be in accordance with AWS D1.1. 4.3.6.2 Unless approved otherwise by the purchaser, all welds shall be continuous. 4.3.6.3 Minimum fillet weld size shall be AISC minimum 3/16 inch (5 mm), whichever is larger, for structural welds. 4.3.6.4 Seal welds shall be 1/8-inch (3-mm) minimum fillet weld. 4.3.6.5 Welds to connection plates embedded in concrete shall be deposited in a sequence that minimizes distortion of the embedment to plus or minus 1/8 inch (3 mm) of flat or true. 4.3.6.6 If the contract documents require welding to existing facilities that were constructed before 1963 and/or using steel other than ASTM A36, erector shall follow the welding procedure provided by the engineer of record. 4.3.7 Correction of Errors 4.3.7.1 Fit-up bolts and drift pins shall not be used to bring improperly fabricated members and parts into place (springing). 4.3.7.2 Drift pins shall not be driven with such a force as to damage adjacent metal areas. 4.3.7.3 Holes in connections that misfit by more than 1/16 inch (1 mm) shall be corrected as directed by the engineer of record. 4.3.7.4 Enlargement of holes shall be made only when approved by the engineer of record, and made by reaming or drilling only. Flame cutting, burning, gouging, chipping, or drift punching shall not be permitted. 4.3.7.5 Unless approved by the engineer of record, packing, shimming, filling, or wedging shall not be permitted to correct faulty work. 4.3.7.6 One filler plate up to 1/8-inch (3-mm) thickness may be used in spaces between members to be bolted. The engineer of record s approval shall be required for filler plate requirements greater than 1/8 inch (3 mm). 4.3.8 Steel Joists 4.3.8.1 Field welding or bolting joists to supporting steel framework shall be in accordance with the SJI specifications for the type of joists used, the erection/shop drawings, and other contract documents. 4.3.8.2 Modifications or repairs to steel joists shall not be performed without prior written approval of the engineer of record. Page 9 of 10

PIP STS05130 COMPLETE REVISION Structural and Miscellaneous Steel Erection Specification February 2011 4.3.8.3 Use of power-driven or powder-actuated fasteners in the diagonal and bottom chord members of the joists shall not be permitted. 4.3.9 Floor Plate and Grating 4.3.9.1 All field-cut floor plate or grating openings requiring toe plate protection or banding shall be installed in accordance with detail STS05130-01. 4.3.9.2 The grating and floor plate shall be fastened in accordance with the design drawings. A minimum of four fasteners per panel shall be used. 4.3.10 Metal Decking for Floors and Roofs 4.3.10.1 Floor and roof deck sheets shall be installed in accordance with the deck manufacturer s installation instructions and the contract documents. 4.3.10.2 All sags, deformations, holes, and other irregularities shall be repaired. 4.3.10.3 If damage has occurred to shop-applied coatings on metal decking, field touch-up shall be in accordance with the decking manufacturer s recommendations. 4.3.11 Shear Connectors 4.3.11.1 All shear stud attachments shall be welded in strict accordance with the stud manufacturer s recommendations for welding procedure and welding equipment. 4.3.11.2 If two or more stud welding guns are operated from the same power source, the guns shall be interlocked so that only one gun can be operated at a time to ensure that the power source has fully recovered from making one weld before another weld is started. 4.3.11.3 All ceramic insulators shall be removed from the base of the studs after welding. 4.3.12 Coating Repairs 4.3.12.1 All erection damage to hot-dip galvanized coatings shall be repaired in accordance with PIP STS05120. 4.3.12.2 All erection damage to shop-applied paint coatings shall be repaired in accordance with the purchaser s coating specification. 4.3.12.3 All galvanized bolt assemblies tightened against shop-applied paint shall be painted. 4.3.12.4 Where twist-off bolt assemblies are used, ends of bolts shall be coated to match the steel coating system. Page 10 of 10

PROCESS INDUSTRY PRACTICES FABRICATION/INSTALLATION DETAILS FIELD LOCATED AND FIELD STS05130-01 JAN 2011 PAGE 1 OF 1 FABRICATED GRATING OPENINGS NON BANDED OPENING, OPENING SHALL BE BANDED IF MORE THAN THREE BEARING BARS OR 10% OF PANEL WIDTH ARE CUT. SEE BANDED OPENING DETAIL BELOW. WHERE OPENINGS ARE NOT BANDED, BEARING BARS SHALL BE CUT TO PRESENT A NEAT, FINISHED APPEARANCE. C PIPE & OPENING OPENING DIA.= PIPE, INSULATION, OR CONDUIT O.D.+ 1 (25) C PIPE & OPENING A A GRATING OPENING DIA.= PIPE, INSULATION, OR CONDUIT O.D.+ 4 (100) 1/4" x 5" (6x125)TOE PL C PIPE & BANDED OPENING OPENING PLAN 1/4" x 5" PL OR CARBON STEEL PIPE w/ 1/4" MINIMUM WALL THICK 1/8 (3) 1/8 (3) EACH BEARING BAR 4 (100) GRATING 1/8 (3) SECTION A-A FIELD LOCATED AND FIELD FABRICATED OPENINGS (FOR FIELD LOCATED OPENINGS > 12 (300) DIA. OR RECTANGUALR OPENINGS, CONTACT DESIGN ENGINEER) DIMENSIONS ARE GIVEN IN FEET AND/OR INCHES. METRIC DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS, UNLESS NOTED OTHERWISE.