SECTION TAPPING SLEEVES AND VALVES

Service Saddles/ Brass Alloy/ Stainless Steel Straps for Cast, Ductile & PVC Pipe

All definitions are defined according to ANSI/AWWA C

All definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves

Water & Industrial Products Catalog

ARTICLE 26 UTILITY LINE INSTALLATION REQUIREMENTS

Effective Date: Revision #: 1. Section H: Repair Sleeves, Couplings, Clamps & Non-Pressure Adapters. Pipe Adapters, Non-Pressure

KENNEBUNK, KENNEBUNKPORT & WELLS WATER DISTRICT MATERIAL SPECIFICATIONS 10/11/2018

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

REGIONAL CONSTRUCTION STANDARDS

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

MATERIAL/MANUFACTURER SPECIFICATIONS FOR DISTRIBUTION WATER MAINS AND APPURTENANCES

SPECIAL PROVISION TO SPECIAL SPECIFICATION Water Mains and Service Lines

DETAILED WATER MAIN SPECIFICATONS INDEX. Sec. No. Items Page Nos.

SECTION 2100 WATER MAIN

SPECIFICATIONS FOR PIPE JOINT RESTRAINT SYSTEMS Revised April 2010

SECTION III: Water Main Materials Specifications

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION DUCTILE IRON PIPE, FITTINGS AND SPECIAL ITEMS

Copper-Type K soft Drawn 40, 50 HDPE 100 and larger

Iron Check Valves & Y-Strainers Illustrated Index

KENT COUNTY WATER AUTHORITY. ERRATUM to Rules and Regulations of the Kent County Water Authority

Series 2000PV Mechanical Joint Restraint for PVC Pipe

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

SECTION PIPING SPECIALS

SECTION PIPING SPECIALTIES AND ACCESSORIES

Diffused Aeration Piping Equipment

Combination Air Valves - Stainless Steel/ Sanitary Sewer/ For 2 Thru 12 Mains

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

CITY OF LEE S SUMMIT PUBLIC WORKS DEPARTMENT

EXHIBIT D SEACOAST UTILITY AUTHORITY 4200 HOOD ROAD PALM BEACH GARDENS, FL (PHONE: ) "SHOP" SPECIFICATIONS

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

7. Allowable Fittings.

CITY OF LEE S SUMMIT PUBLIC WORKS DEPARTMENT

SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE

1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME)

[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept.

SPECIFICATION SERVICE SADDLE DOUBLE BALE MODEL 314

SECTION of GENERAL. A. Description

INVITATION TO BID. August 3, Dear Vendor,

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

NOTICE OF DISCONTINUATION,

City of Lewiston. Public Works Department Inventory Management System Bid No April 12, 2017

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION

AMERICAN FLOW CONTROL 2"-12" SERIES 2500 RESILIENT WEDGE GATE VALVE

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe

SPECIFICATION SERVICE SADDLE DOUBLE STRAP MODEL 317

SECTION ROLLER GATES

SPECIFICATIONS - DETAILED PROVISIONS Section Plastic (PVC) Pressure Water Pipe & Fittings C O N T E N T S

SECTION VALVES. This section includes materials, testing, and installation of manually operated valves.

Standard Tube & Pipe Adapters

1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME).

SECTION 027 SPECIFICATIONS - PIPE MATERIALS FOR SEWERS

American Flow control 2-12 Series 2500

RSCV1 AMERICAN DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL. It s What We Know. SERIES 2100 RESILIENT SEATED CHECK VALVE

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

SPECIFICATIONS FOR PIPE FITTINGS VALVES FIRE HYDRANTS CITY OF ALLIANCE, OHIO. Alan Andreani, Ed. D. Mayor of Alliance

TOTAL PIPING SOLUTIONS, INC. Quick Cam. Rapid Seal Repair Clamp. Patent Pending Technical Specifications

Available End Connections & Size Range

SUPPLEMENTAL SPECIFICATIONS TO STANDARD SPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION NO. 2611

SAINT PETERSBURG CITY COUNCIL. Consent Agenda. Meeting of April 3, The Honorable James Bennett, Chair and Members of City Council

SECTION FIRE HYDRANTS

DUCTILE IRON PIPE AND FITTINGS

CITY OF FARGO SPECIFICATIONS SEWER AND WATER SERVICE CONNECTIONS

SECTION ALUMINUM HANDRAIL SYSTEMS

AMERICAN DARLING MARK

ITEM 442 METALS FOR STRUCTURES

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

DIVISION 15- MECHANICAL Section Fire Pumps

Stainless Steel Aeration Equipment Specification

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

Everett Water Department Specifications. & Requirements

General Service Butterfly Valves. Series 120, 140, 160, 300

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

DIVISION 33 - UTILITIES SECTION UTILITY PIPE BORING AND JACKING DIVISION 33 UTILITIES SECTION UTILITY PIPE BORING AND JACKING

STANDARD SPECIFICATION SECTION POLYVINYL CHLORIDE (PVC) DISTRIBUTION PIPE (AWWA C905)

CATALOG C-IRR-0805 AHEAD OF THE FLOW. Irrigation Valves

CATALOG C-IRR-0805 AHEAD OF THE FLOW. Irrigation Valves

MECHANICAL JOINT PIPE

4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT

SEWER FORCE MAIN HDPE PIPE

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

2 5 0 P. S. I. G. AMERICAN DARLING 5 1 /4" B-84-B FIRE HYDRANT

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section DUCTILE IRON PIPE AND FITTINGS

CATALOG C-IRR-0805 AHEAD OF THE FLOW. Irrigation Valves

CATALOG C-IRR-0805 AHEAD OF THE FLOW. Irrigation Valves

APPENDIX C TECHNICAL SPECIFICATIONS HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

AMERICAN DARLING 5 1 /4" B-62-B FIRE HYDRANT

***************************************************************************************************************

SECTION CROSS CONNECTION CONTROL AND BACKFLOW PREVENTION

PART IV MATERIALS 4.1 BACKGROUND:

This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems.

d.p. Consulting Engineers, Inc.

Class 125S/200WOG Bronze Gate Valve Non-Rising Stem, Threaded Ends Testing: BS EN 12288, BS 5154, BS EN Working Pressure: PN16

Transcription:

100-35 San Antonio Water System Material Standard Specifications REVISED DECEMER 2011 1. SCOPE These specifications cover-tapping sleeves installed on pipe from 4 and larger nominal pipe diameter. 2. GENERAL REQUIREMENTS The band shall conform to the minimum OD size ranges and lengths specified in paragraph 3. The Flange shall be manufactured in compliance with AWWA C207, Class D ANSI.16.1 drilling, recessed for tapping valve MSS-SP60. Or Mechanical Joint tapping sleeve outlet shall meet or exceed all material specifications as listed below and be suitable for use with standard mechanical joint x mechanical joint resilient wedge gate valves per ANSI/AWWA C509-94.. a) Tapping sleeves from 4 through 12 nominal pipe diameter shall meet the following minimum requirements. 1. The entire fitting shall be stainless steel type 304 (18-8). The body, lug, and gasket armor plate shall be in compliance with ASTM A240. The Flange shall be cast stainless steel in compliance with ASTM A743. The MJ outlet shall be one-piece casting made of stainless steel. The test plug shall be ¾ NPT in compliance with ANSI 2.1 and shall be lubricated or coated to prevent galling. All metal surfaces shall be passivated after fabrication in compliance with ASTMA-380. 2. The gasket shall provide a 360-sealing surface of such size and shape to provide an adequate compressive force against the pipe after assembly, to affect a positive seal under the combinations of joint and gasket tolerances. The materials used shall be vulcanized natural or vulcanized synthetic rubber with antioxidant and antioxidant ingredients to resist set after installation. No reclaimed rubber shall be used. A heavy-gauge-type 304-stainless armor plate shall be vulcanized into the gasket to span the lug area. 1

REVISED DECEMER 2011 3. The lugs shall be heliarc welded (GMAW) to the shell. The lug shall have a pass-through-bolt design to avoid alignment problems and allow tightening from either side of the main. olts shall NOT E integrally welded to the sleeve. Finger Lug designs are not approved; it is the intent of these specifications to allow a tapping sleeve that has a lug design similar to the approved models. 4. olts and nuts shall be type 304 (18-8) stainless steel and lubricated or Teflon coated to prevent galling or seizing. ent or damaged unite will be rejected. 5. Quality control procedures shall be employed to insure that the shell, Lug, armor plate, gasket and related hardware are manufactured to be free of any visible defects. Each unit, after proper installation, shall have a working-pressure rating up to 200 psi, and a test pressure of 250 psi. 6. The sleeve construction shall provide a positive means of preventing gasket cold flow and/or extrusion. 7. Each sleeve shall be stenciled, coded or marked in a satisfactory manner to identify the size range. The markings shall be permanent type, water resistant, that will not smear or become illegible. b) Tapping sleeves from 16 and larger nominal pipe diameter shall meet the following minimum requirements: 1. The body shall be in compliance with ASTM A285, Grade C or ASTM A36. The test plug shall be ¾ NPT conforming to ANSI 2.1. 2. The gasket shall provide a watertight sealing surface of such size and shape to provide an adequate compressive force against the pipe. After assembly, the gasket will insure a positive seal under all combinations of joint and gasket tolerances. Gaskets shall be formed from vulcanized natural or vulcanized synthetic rubber with antioxidant ingredients to resist set after installation. No reclaimed rubber shall be used. 2

REVISED DECEMER 2011 3. olts and nuts shall be high strength, corrosion resistant, low alloy, pre AWWA C111, ANSI A21.11. 4. Quality control procedures shall be employed to insure that the shell, gaskets, and related hardware area are manufactured to be free of visible defects. Each unit, after proper installation, shall have a working-pressure rating up to 150 psi and a maximum test pressure of 200 psi. 5. Unless otherwise noted, unit shall be protected by fusion Epoxy 8-10 mil line and cost process per AWWA C213. 6. Units for concrete, steel cylinder pipe shall be furnished with load bearing setscrews on the gland flange to transfer loads on the outlet away from the steel cylinder and onto the sleeve. Epoxy coated tapping sleeves do not require grout seal cavity (AWWA M-9 Manual). 7. Each Sleeve shall be stenciled, coded or marked in a satisfactory manner to identify the size range. The marking shall be permanent type, water resistant, that will not smear or become illegible. 3. STANDARD RANGES: (4 30 NOMINAL PIPE DIAMETER) Nominal Dia.x Min Length Flg. Outlet Range Minimum OD Range** 4 x 16 4 A 6 x 16 4 A C 6 x 16 6 A C 4.75 4.95 4.90 5.10 6.70 7.10 7.00 7.40 7.35 7.75 6.80 7.15 7.05 7.40 7.40 7.75 3

REVISED DECEMER 2011 STANDARD RANGES: (continued) Nominal Dia.x Min Flg. Outlet Range Minimum OD Length Range** 8 x 16 4 & 6 A C 9.00 9.45 9.35 9.70 9.70 10.10 8 x 20 8 A 9.00 9.35 9.35 9.70 C 9.70 10.00 10 x 16 4 & 6 A 11.03 11.47 10 x 20 8 11.60 12.00 10 x 24 10 12 x 16 4 & 6 A 13.00 13.40 12 x 20 8 13.40 13.80 12 x 24 12 x 32 10 12 C 14.10 14.50 16 x 12 4 & 6 17.33 17.87 16 x 16 8 18.62 19.19 16 x 20 10 16 x 24 12 16 x 36 16 * 20 x 12 4 & 6 A 21.51 22.15 20 x 16 8 23.46 24.16 20 x 20 10 20 x 24 12 20 x 36 16 * 20 x 40 20 * 4

REVISED DECEMER 2011 STANDARD RANGES: (continued) Nominal Dia.x Min Flg. Outlet Range Minimum OD Length Range** 24 x 12 24 x 16 24 x 20 24 x 24 24 x 36 24 x 40 24 x 48 4 & 6 8 10 12 16 * 20 * 24 * A 25.71 26.41 28.14 28.84 30 x 12 30 x 16 30 x 20 30 x 24 30 x 36 30 x 48 30 x 48 4 & 6 8 10 12 16 * 20 * 24 x 30 * A 29.78 30.48 31.52 32.22 * Range to be specified on order. ** Ranges may be broadened, but not narrowed. For concrete steel cylinder pipe, the OD of the pipe and cylinder shall be supplied with the order. 4. For pipe larger than 30 nominal diameter, tapping sleeves shall be customfabricated to fit non-standard ranges, in conformance with the intent of these specifications. 5. The San Antonio Water System may, at no cost to the manufacturer, subject random units to testing by an independent laboratory for compliance with these standards. Any visible defect or failure to meet the quality standards herein will be ground for rejecting the entire order. 6. The attached qualified products list identifies specific manufactured items by catalog number that are approved. 5

REVISED DECEMER 2011 Approved Manufacturers 4 12 Models JCM Industries #432 PowerSeal Cascade Ford Meter ox Romac Industries #3490AS or 3490MJSS CST-1 FTSS SST III Dresser Style 610/630 16 and larger Smith-lair #622 JCM Industries #412 Romac Industries Ford Meter ox PowerSeal SST III Ford Meter FTS 3490MJSS Dresser Dresser Style 610/630 Previous Specification Date: MARCH 2002 MARCH 2004 DECEMER 2011 6