Upgrade of an Oxidation Ditch Using Bio-Mass Carriers

Similar documents
Water Technologies. The AGAR Process: Make Your Plant Bigger Without Making it Bigger

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) and Integrated Fixed-Film Activated Sludge (IFAS)

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Global Leaders in Biological Wastewater Treatment

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

2015 HDR, Inc., all rights reserved.

MEMBRANE AERATED BIOFILM REACTOR

Oxidation Ditch Technologies

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

We Know Water. AnoxKaldnes. Moving Bed Biofilm Reactor (MBBR) Integrated Fixed-Film Activated Sludge (IFAS) and ANITA Mox Deammonification

Case Study. Biological Help for the Human Race. Bathurst Municipal Wastewater Treatment Works, New South Wales, Australia.

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

Palmer Wastewater Treatment Plant Environmental Impacts. A summary of the impacts of this treatment alternative are listed below:

SBR PROCESS FOR WASTEWATER TREATMENT

COMPARISON STUDY BETWEEN INTEGRATED FIXED FILM ACTIVATED SLUDGE (IFAS), MEMBRANE BIOREACTOR (MBR) AND CONVENTIONAL ACTIVATED SLUDGE (AS) PROCESSES

Oxidation Ditch Technologies WATER TECHNOLOGIES

WASTEWATER TREATMENT SYSTEM

Bioprocess Intelligent Operating System -Beyond Ammonia Control-

Energy Savings Through Denitrification

orld water works Clean Water and Energy from Wastewater IDEAL MBBR IDEAL IFAS

Case Study. BiOWiSH Aqua has Positive Long-Term Effects. Biological Help for the Human Race

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

2015 Spring Conference

CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements

SBR FOR LOW FLOW APPLICATIONS

Appendix D JWPCP Background and NDN

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2018

Review of WEFTEC 2016 Challenge & Overview of 2017 Event. Malcolm Fabiyi, PhD, MBA Spencer Snowling, PhD. P.Eng

BIOSPHERE MOVING BED BIOLOGICAL SYSTEMS

MEMBRANE AERATED BIOFILM REACTORS OXYGENATED FUN WITH LESS CARBON COST KELLY MARTIN AND SANDEEP SATHYAMOORTHY

40 years experience in fine bubble aeration. 20 years innovation in IFAS textile fixed bed technology

Pavel Hajda, Ph.D., P.E., Symbiont

AquaNereda Aerobic Granular Sludge Technology

NITROGEN REMOVAL GRANT WEAVER, PE & WWTP OPERATOR PRESIDENT THE WATER PLANET COMPANY. Create Optimal Habitats

GRANULAR ACTIVATED SLUDGE

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

CLR Process. Vertical Loop Configuration

Integrated Water & Wastewater Treatment Solutions Extending Nature s Capacity

Operation of a small scale MBR system for wastewater reuse

Making Your Plant Denitrify

UPGRADING FOR TOTAL NITROGEN REMOVAL WITH A POROUS MEDIA IFAS SYSTEM

Increasing Denitrification in Sequencing Batch Reactors with Continuous Influent Feed

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

TWO YEAR CASE STUDY OF INTEGRATED FIXED FILM ACTIVATED SLUDGE (IFAS) AT BROOMFIELD, CO WWTP West 124th Street Broomfield, CO 80020

AMMONIA REMOVAL USING MLE PROCESS EXPERIENCES AT BALLARAT NORTH. David Reyne. Central Highlands Water Authority

Demonstration of IFAS Technology for Cold Temperature Nitrification in Lagoon WWTFs at Clare and Ludington, Michigan

Design, Construction and Startup of the First Enhanced Nutrient Removal Plant in Maryland Funded by the Chesapeake Bay Restoration Fund

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

LEMNA BIOLOGICAL TREATMENT PROCESS LEMTEC TM TECHNOLOGIES, INC.

Module 17: The Activated Sludge Process - Part III Answer Key

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea

Nutrient Removal Optimization at the Fairview WWTP

Membrane Biofilm Reactor (MBfR): A New Approach to Denitrification in Wastewater Setting

Compact Waste Water Treatment MBR /MBBR Technology

Upgrading Lagoons to Remove Ammonia, Nitrogen, and Phosphorus *nutrient removal in cold-climate lagoon systems

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2014

Presentation Outline

Waste water treatment

Presenters: Rodrigo Pena-Lang, PE (D&B Engineers), Magdalena Gasior, PE (D&B Engineers) and Paul D. Smith, PE (NYCDEP)

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

Bloomingdale WWTF Private/Public Partnership Works. Bob Wilcox, PE Fleis & VandenBrink May 10, 2016

A SUBMERGED ATTACHED GROWTH BIOREACTOR FOR DECENTRALIZED WASTEWATER TREATMENT

Aeration University Advanced Concepts in Energy Efficiency

SECTION 8.0 NEWPCC SECOND PRIORITY CONTROL ALTERNATIVES

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

Wet Weather and Advanced Treatment: Procurement Strategies to Secure the Right Technology

Effect of oxidation ditch horizontal velocity on the nitrogen removal process

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012

OPTIMIZATION OF AN INTERMITTENTLY AERATED AND FED SUBMERGED MEMBRANE BIOREACTOR

Aqua MSBR MODIFIED SEQUENCING BATCH REACTOR

Wastewater Nitrogen Characteristics, Treatment and Removal Options. Bob Smith, Orenco Systems, Inc. GEC 2013

Considerations for the Use of ORP in Wastewater Treatment Applications

The High-Tech of a Creek. The Biofilm Technology for Large Wastewater Treatment Plants.

PLANNING FOR NUTRIENT REMOVAL: WHAT STEPS CAN WE BE TAKING NOW?

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

Rabea-Luisa, Schubert Kompetenzzentrum Wasser Berlin 16/05/2018, POWERSTEP Conference, Munich

WWTP Side Stream Treatment of Nutrients Considerations for City of Raleigh s Bioenergy Recovery Project. Erika L. Bailey, PE, City of Raleigh

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

RTC-N: Modelling Ammonia-Based Aeration Control in Real Time for Deeper Process Control

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

MBBR Technology: - A cost effective solution for upgrading existing Waste water Treatment Works. Bruno Bigot

Optimizing Nutrient Removal. PNCWA - Southeast Idaho Operators Section Pocatello, ID February 11, 2016 Jim Goodley, P.E.

Enhanced Nutrient Removal by Extended Aeration. Christina Edvardsson MicroSepTec, Inc

SECTION 9.0 SEWPCC SECOND PRIORITY CONTROL ALTERNATIVES

Integrated Fixed Film Activated Sludge (IFAS) System for Additional Nitrification at the Coldwater WWTP

Upgrade of the Marathon Louisiana Refining Division s Wastewater Treatment Plant to a State-of-the-Art Nitrification-Denitrification Facility

NITROGEN AND PHOSPHOROUS REMOVAL FROM HIGH STRENGTH WASTEWATERS

Baltimore City Department of Public Works

Biological Phosphorus Removal Technology. Presented by: Eugene Laschinger, P.E.

General Operational Considerations in Nutrient and Wet Weather Flow Management for Wastewater Treatment Facilities Part II

RE ENGINEERING O&M PRACTICES TO GET NITROGEN & PHOSPHORUS REMOVAL WITHOUT FACILITY UPGRADES

DESIGNING LAGOON-BASED WWTP FOR <1 MG/ L AMMONIA (AND TN) IN <34 F WATER. Nick Janous Regional Manager

Probabilistic Modeling of Two-Stage Biological Nitrogen Removal Process: Formulation of Control Strategy for Enhanced Process Certainty

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection

EFFECT OF FERROUS SULPHATE ON THE SIMULTANEOUS ORGANIC MATTER AND NUTRIENT REMOVAL PERFORMANCE OF SEQUENCING BATCH REACTOR

Transcription:

Upgrade of an Oxidation Ditch Using Bio-Mass Carriers Nir Assulin and Yigal Master Aqwise - Wise Water Technologies Ltd. The Problem Oxidation ditches (OD) are very popular wastewater treatment processes for small to medium sized municipalities that have to meet stringent water quality standards in terms of BOD and nitrogen removal. However, when an upgrade is required due to increase in wastewater quantities or due to stricter regulations, there is usually a need to increase the OD volume in order to comply with the new quality standards. Introduction of biomass carriers into an existing OD is a potential method of enhancing the treatment capacity of the system without increasing its footprint. The advantage of biomass carriers over activated sludge-based systems becomes more prominent especially at low temperatures when an increase in nitrification capacity is required. This approach, however, cannot be implemented in a straightforward manner due to the unique hydraulic patterns within the oxidation ditch. Goals of Presentation This paper presents a case study of an OD upgrade in Spain by introducing biomass carriers and performing some internal structural and hydraulic changes in the existing ditch. The performance of the upgraded OD module has been compared to an existing OD module at the same site that had not been upgraded. A Case Study The existing OD was operating with two parallel modules at a total flow rate of 1,100 m 3 /d, exhibiting very poor nitrification capacity. The wastewater characteristics and the required effluent quality are presented in Table 1. It was required to upgrade one of the two existing modules in order to double its inflow rate to 1,100 m 3 /d, while improving the OD treatment capacity in terms of organic matter and nitrogen removal. (Page 1 of 6)

The process configuration chosen to upgrade the treatment capacity of the system was IFAS (Integrated Fixed Film Activated Sludge; Figure 1). The IFAS configuration allows simultaneous removal of BOD by the suspended biomass and efficient nitrification by the fixed biomass upon the carriers. The original aerobic zone was separated from the anoxic zone by vertical partitions and filled with Aqwise Biomass Carriers (ABC), possessing a protected surface area of ~650 m 2/ m 3 carriers (Figure 2). Additional structural changes included installation of wedge wire screens on the installed partition to retain the biomass carriers within the aerobic zone and rearrangement of diffusers on the floor of the aerobic zone to enable carriers mixing. Since the installation of the vertical partitions resulted in a change in the original OD mixed liquor flow pattern, the liquid was transferred from the anoxic to aerobic zone by means of air-lift pumps at a rate of ~ 300 m 3 /h. Several coarse bubble diffusers were placed in several regions within the anoxic zone in order to prevent sludge sedimentation. The two modules were operated at an average flow rate of 550 m 3 /d in order to compare between their performances. Results and Discussion Figures 3 to 5 present the effluent qualities in the original and upgraded modules in terms of total N, ammonia and nitrate during one month of operation. It can be clearly seen that N removal was excellent in the upgraded module, reaching the required effluent quality of <15 mg/l (Figure 3), while in the original OD the effluent levels were as high as 35 mg/l. The ammonia and nitrate results (Figures 4 and 5, respectively) clearly demonstrate the advantages of the IFAS configuration over the original design at low temperatures. The effluent concentrations remained stable and low, as the water temperature went down from ~23 o C in summer to ~ 17 o C in the beginning of November, demonstrating excellent (Page 2 of 6)

nitrification and denitrification capacities of the system. On the other hand, nitrification has been steadily inhibited in the original module with decrease in the temperature, resulting in ammonia effluent levels as high as 30 mg/l in the beginning of November. Absence of nitrate in the effluent also implied that ammonia oxidation was not taking place in the original OD. Table 2 presents the values of the quality parameters averaged over a period of one month in the two modules. It can be seen that the performance of the upgraded module is better than the performance of the original one in terms of organic matter and nitrogen removals. The performance of the upgraded module under increasing flows and loads at temperatures lower than 17 o C is being tested these days. (Page 3 of 6)

Table 1. Wastewater characteristics and effluent requirements. Parameter Units Design value INFLUENT Flow rate m 3 /d 1,090 Temperature o C 10-22 COD T mg/l 440 T BOD 5 mg/l 220 TSS mg/l 145 TKN mg/l 52 TP mg/l 8 EFFLUENT REQUIREMENTS COD T mg/l < 125 T BOD 5 mg/l < 25 TSS mg/l < 35 TN mg/l < 15 Figure 1. A schematic representation of the upgraded OD (Page 4 of 6)

Figure 2. ABC (Aqwise Biomass Carriers) used in the upgrade of the OD Effluent total N [mg N/L] 40 35 30 25 20 15 10 5 0 Original module Upgraded module Design 7.10.08 12.10.08 17.10.08 22.10.08 27.10.08 1.11.08 6.11.08 11.11.08 Date Figure 3. Comparison between effluent total N levels in the upgraded and original modules (Page 5 of 6)

Effluent ammonia [mg N/L] 35 30 25 20 15 10 5 0 Original module Upgraded module 7.10.08 12.10.08 17.10.08 22.10.08 27.10.08 1.11.08 6.11.08 11.11.08 Date Figure 3. Comparison between effluent ammonia levels in the upgraded and original modules Effluent nitrate [mg N/L] 8 7 6 5 4 3 2 1 0 Original module Upgraded module 7.10.08 12.10.08 17.10.08 22.10.08 27.10.08 1.11.08 6.11.08 11.11.08 Date Figure 3. Comparison between effluent nitrate levels in the upgraded and original modules Table 2. Effluent quality parameters in the two modules averaged over one month of operation. Parameter Requirement Original Upgraded TN 15 23.3 8.8 NH + 4 -N - 15.9 2.8 NO - 3 -N - 2.5 0.5 T BOD 5 25 16.8 11.0 (Page 6 of 6)