An Assessment Methodology of Shallow Geothermal Energy Projects

Similar documents
Study on the change of soil temperature in Ground Source Heat Pump System Shili Han1, a*, Shunyu Su1,b, Lamei Liu1,c, Chuanhui Zhou1,d, Lei Shi2,e

Influencing Factors on Ground Heat Balance of GSHP System Xiaohong Zhang1, a *, Zehua Liu2,b, Chao Zhang3,c and Long Ma4,d

Research on single hole heat transfer power of ground source heat pump system

Fatigue Strength Analysis on the Automobile Stabilizer Bar Based on ANSYS

*Corresponding authors. Tel.: x415, address: (N. Zhu)

Available online at ScienceDirect. Energy Procedia 78 (2015 )

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

EXPERIMENT AND NUMBERICAL ANALYSIS OF THE DISCONTINUOUS OPERATION FOR GROUND HEAT EXCHANGERS

Numerical and analytical analysis of groundwater influence on the pile ground heat exchanger with cast-in spiral coils

Open Access The Research of Capillary Pressure in the Process of CO 2 Displacement in Low-Permeability Reservoir

Heat Pump Technology Applies on Air-conditioners Impact on Electric Power

Open Access Analysis and Evaluation of Oil-water Relative Permeability Curves

Research on integrated solar and geothermal energy engineering design in hot summer and cold winter area

REGRESSION ANALYSIS ON INFLUENCE OF VARIOUS FACTORS ON HEAT TRANSFER OF VERTICAL GROUND HEAT EXCHANGER

Performance investigation of multiple-tube ground heat exchangers for ground-source heat pump

Finite Element Simulation Research on Medium Plate Multi-Pass Welding Temperature Field

A PILOT PROJECT OF THE CLOSED-LOOP GROUND SOURCE HEAT PUMP SYSTEM IN CHINA

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Tunnels, a new potential for sensible heat storage in rock: 3D numerical modelling of a reversible exchanger within tunnel

The Design of Water Intake System and Analysis of Water Quality Conditions of the Regional Energy System of Complex River Water Source Heat Pump

A review on heat transfer enhancement of borehole heat exchanger

Optimal Design for a Hybrid Ground-Source Heat Pump

Power Grid Project Cost Intelligent Evaluation Technology Based on Probability Statistics

Magda Kaczmarczyk and Michał Kaczmarczyk

Research Article Investment and Economy Analysis of Water-Source Heat Pump System in Chongqing, China

New Large Geothermal Storage Project in Zurich/Switzerland for Heating and Cooling

Numerical Simulation of Liquefaction Deformation of Sand Layer around Bucket Foundations under Dynamic Loadings

Effect of insulation ground on anti-condensation in rural residence

Temperature Field Calculation and Analysis within Steel Tube Reinforced Columns

Long-Term Heating Test Using the Semi-open Loop Ground Source Heat Pump System

Study on Water-Cooled Solar Semiconductor Air Conditioner

Optimization and Stress Analysis of Underground Oil Pipelines in High and Steep Slope Areas

Assessing the feasibility of highdensity subsurface heat extraction in urban areas

Enhancement of Heat Exchange Capacity of Ground Heat Exchangers by Injecting Water into Wells

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Heat exchanger performance of ground source heat pump by water cooling method

The research and simulation on passive solar house with the attached. sunspace in Beijing

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Energy and Buildings

DEVELOPMENT AND APPLICATION OF AN INNOVATIVE SHALLOW GROUNDWATER HEAT PUMP SYSTEM

DEVELOPMENT OF A DESIGN AND PERFORMANCE PREDICTION TOOL FOR THE GROUND SOURCE HEAT PUMP SYSTEM

SUPERVISED ROCK-MASS STORAGE OF THERMAL ENERGY PRODUCED BY A SOLAR THERMAL PANEL

Application of Low Cost Active and Passive Energy Saving Technologies in an Ultra-low Energy Consumption Building

Cutting Properties Analysis of Titanium Alloy (Ti-6Al-4V) Based on Cryogenic Cooling

Vehicle Front Structure Energy Absorbing Optimization in Frontal Impact

The design and operational analysis of ground source heat pump in large-scale construction

A Simple Engineering Analysis Method to Evaluate the Geothermal Potential from a Hot Water Aquifer

CCHP System with Interconnecting Cooling and Heating Network

RETRO-COMMISSIONING OF A HEAT SOURCE SYSTEM IN A DISTRICT HEATING AND COOLING SYSTEM Eikichi Ono 1*, Harunori Yoshida 2, Fulin Wang 3 KEYWORDS

geoexchange as an alternative energy source DESIGN APPROACHES

Production prediction model of coalbed methane wells at stable production stage

Study on Metering Scheme of Seismic Experiment for Shear Wall Built with Precast Hollow Slab

Study on feasible technical potential of coal to electricity in china

Geothermal Heat Pump Systems Efficiency in Russia

Ground-Coupled Heat Pump And Energy Storage

PREPROCESSOR FOR THE GENERATION OF G-FUNCTIONS USED IN THE SIMULATION OF GEOTHERMAL SYSTEMS

A NOVEL TECHNIQUE FOR EXTRACTION OF GEOTHERMAL ENERGY FROM ABANDONED OIL WELLS

Effects of irrigation on groundwater recharge under deep buried depth condition

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Physical Simulation for Water Injection of Horizontal Wells in Naturally Fractured Buried- Hill Reservoirs

Ground-source Heat Pumps State of the Art

Open Access Application & Research on Foundation Stabilization Structure during Work Progress of Civil Engineering

The Influence of Operation Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

LARGE-SCALE APPLICATION OF MUNICIPAL RECLAIMED WATER SOURCE HEAT PUMPS TO A DHC SYSTEM IN THE BEIJING OLYMPIC VILLAGE

Study on the heat transfer model and the application of the underground pipe system

Study on the deformation process of titanium alloy bars based on compact hot continuous rolling

First Thermal Response Test in Libya Abstract 1. Introduction 2. Background

Available online at ScienceDirect. Energy Procedia 70 (2015 )

Comprehensive experimental study on prevention of land subsidence caused by dewatering in deep foundation pit with hanging waterproof curtain

Thermal Performances Of Three Types Of Ground Heat Exchangers In Short-Time Period Of Operation

Study on the Heat Transfer Characteristics Performed in the Infrared Thermography Detection of Welded Structure

A Short Sequence Splicing Method for Genome Assembly Using a Three- Dimensional Mixing-Pool of BAC Clones and High-throughput Technology

Parametric Study for Evaluation of Design Parameters of Standing Column Well

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Open Access Experimental Study on Road Properties of High Liquid Limit Soil in Yunfu Highway

STUDY ON THE DESIGN PROCEDURE OF GEOTHERMAL HEAT PUMPS: GEOTHERMAL HEAT PUMP SYSTEM WITH

Open Access A Novel Approach to Detect Tubing Leakage in Carbon Dioxide (CO 2 ) Injection Wells via an Efficient Annular Pressure Monitoring

Open Access Different Damaged Shaft Lining Concrete Resistance to Sulfate Corrosion

Numerical Simulation on Effects of Electromagnetic Force on the Centrifugal Casting Process of High Speed Steel Roll

District GeoExchange Systems & Waste Heat Recovery

Thermal analysis of recent crude oil transportation technologies in China

CLOSED-LOOP HEAT EXCHANGER FOR GROUND COUPLED HEAT PUMPS

Song Pan et al. / Energy Procedia 142 (2017)

Building performance based on measured data

Geothermal HVAC Systems - The Basics and Applications (Draft) George Hu, P.E., LEED AP Air Water Energy Engineers, Inc.

EFFECTS OF WEATHERS AND INDOOR TEMPERATURES ON PERFORMANCE OF ENERGY RECOVERY VENTILATOR. Yanping Zhou, Jingyi Wu, Ruzhu Wang

NUMERICAL SIMULATION OF GROUND HEAT AND WATER TRANSFER FOR GROUNDWATER HEAT PUMP SYSTEM

Limitations of Using Uniform Heat Flux Assumptions in Sizing Vertical Borehole Heat Exchanger Fields

Performance Improvement on Water-cooled Cold-Plate

Research Article Experimental Study on Properties of Methane Diffusion of Coal Block under Triaxial Compressive Stress

Research on Sustainable Utilization of Shallow Geothermal Resources in Beijing, China

Overview of Geothermal Technologies

Improvement of a Two-Dimensional Borehole Heat Exchanger Model

Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

TEMPERATURE STRATIFICATION OF CIRCULAR BOREHOLE THERMAL ENERGY STORAGES

Numerical Study on the Effects of Flue-Gas Inlet Type for the Flue-Gas-Desulfurization Wet Scrubber

Field Validation of a Short Time Step Model for Vertical Ground-Loop Heat Exchangers

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

Transcription:

Send Orders for Reprints to reprints@benthamscience.ae The Open Fuels & Energy Science Journal, 214, 7, 169-175 169 An Assessment Methodology of Shallow Geothermal Energy Projects You Shuang *,1, Li Xiangyu 2, Gao Yu 1 and Tang Wendi 1 Open Access 1 University of Science and Technology Beijing, School of Civil and Environmental Engineering, Beijing, 83, China 2 China State Construction Engineering Corporation, Beijing, 44, China Abstract: Combination of theoretical and numerical analysis, an assessment approach of shallow geothermal energy project is proposed. A case study on Chongqing is carried out to verify the methods. According to the theoretical calculation, the heat transfer power per meter of typical boreholes in Chongqing is 4 W/m for cooling and 5 W/m for heating. The numerical model of m borehole heat exchanger (BHE) of ground sourced heat pump (GSHP) system is built, two sets of heating and cooling loads are input to calculate the ground thermal response, the results show that the thermal unbalance ratio equals to 1.5 would ensure the safe and reliable long time operation of GSHP system. By comparing the single and group borehole model, the heat transfer efficiency of BHE is not influenced by adjacent boreholes with 6m drilling spacing, the temperature distribution among boreholes almost uniform after a year running, however, the increase of cumulative temperature of the ground reaches 2.2 C after five years running. Keywords: Assessment methodology, borehole heat exchanger, shallow geothermal energy, thermal unbalance. 1. INTRODUCTION In order to guarantee the sustained utilization of shallow geothermal energy, reduce the development risk, and obtain the maximization of socioeconomic performance and environmental benefit, the exploration and evaluation of shallow geothermal energy is of great significance. The U.S. ASHRAE Association stipulates relevant clauses on on-site exploration of ground source heat pump engineering, and has two parts in work contents, including hydrologic condition and geological condition [1-2], China Specifications on Exploration and Evaluation of Shallow Geothermal Energy [3] also makes similar regulations, and divides the evaluation on shallow thermal energy into urban area and engineering project, the former evaluates the shallow geothermal energy at the regional scale, and the work content is mainly collecting regional geology and hydrogeological data; the latter is targeted at the site where the ground source heat pump(gshp) project is located, which provides basis for engineering design, and the work content is mainly calculation for single-borehole geothermal energy, underground thermal equilibrium evaluation, forecast evaluation of change in underground temperature field and variation of heat storage. The paper combines the theoretical equation and numerical model, and proposes an engineering project evaluation methodology of shallow geothermal energy. A case study of GSHP system on Chongqing is carried out, theoretical calculation of a single-borehole geothermal energy at m, and established three-dimensional numerical model for drilling. Simulated the heat exchange *Address correspondence to this author at the No., Xueyuan Road, Haidian District, Beijing, 83, P. R. China; Tel: +86--623321; E-mail: youshuang@ustb.edu.cn process of single-borehole and group-borehole buried pipe system under the dynamic load of two different accumulative cooling and heating load ratio, compared the average water temperature of buried pipe and temperature of rock-soil mass, and obtained some results feasible for engineering design and application. 2. SINGLE-BOREHOLE GEOTHERMAL ENERGY Single borehole geothermal energy refers to the power of heat exchange provided by each borehole in the GSHP system, can be directly used for calculating the number of buried pipes in the engineering, and is the most important parameter in design and also the direct reflection of storage of shallow geothermal energy in the engineering. The equation for the geothermal energy in the U-shape buried pipe suggested in Specification on Exploration and Evaluation of Shallow Geothermal Energy [3] as D = ΔT R = 2π L T 1 T 4 1 ln r 2 + 1 ln r 3 + 1 ln r (1) 4 λ 1 r 1 λ 2 r 2 λ 3 r 3 where λ 1, λ 2 and λ 3 refer to the heat conductivity (W/m C) of pipe, backfill materials of borehole and rock-soil mass surrounding the borehole respectively; L is the length of heat exchanger of buried pipe (m); r 1, r 2, r 3 and r 4 are equivalent radius of buried pipe (m), equivalent external diameter of buried pipe (m), radius of borehole (m), and radius of temperature influence of heat exchange (m) respectively; T 1 and T 4 are the average temperature of fluid within the buried pipe and the initial temperature of rock-soil mass. Bureau of Geology and Mineral Exploration drilled boreholes and samples in some region of Chongqing, collected 237 groups of rock-soil thermos-physical parameters [4]. The results show that in the region, the rock 1876-973X/14 214 Bentham Open

17 The Open Fuels & Energy Science Journal, 215, Volume 8 Shuang et al. constitution is mainly mudstone, shale, sandstone and limestone, and the heat conductivity measured at the laboratory is 2.~3.2 W/(m K). Besides the laboratory measurement, Thermal response test is carried out in ten places, including Shuangfengqiao and Lijia Town in the main urban area, the rock-soil comprehensive heat conductivity λ3 was calculated by using infinite line source model, the result is 1.93~3.1 W/(m K), and the average is 2.62 W/(m K). Borehole and pipe adopts vertical drilling of borehole in the stratum, and usually the HDPE pipe is positioned in the borehole, and then backfilled. The drilling depth is often 5-15m, and the diameter of borehole is 12-15mm [4]. In the following calculation, the radius of the borehole r 3 is 75mm, the length of the borehole L is m, the spacing between boreholes is 6m, which means the radius of temperature influence of heat exchange r 4 =3 m, the pipe style is double U in series, the equivalent radius r 1 of buried pipe is the internal diameter of pipe 21mm, and the equivalent external diameter r 2 of buried pipe is the external diameter of pipe 25mm. Given the data from geological exploration, the rock-soil initial temperature T 4 is measured through non-power circulation, and different boreholes are 17.79 C~21.27 C, with the average of 19.83 C. For the average temperature T 1 of fluid within the buried pipe, the current specification states that the temperature scope for the normal running of heat pump unit is ~4 C (cooling) and -5~25 C (heating) [5]. In design, the average water temperature of buried pipe in cooling season and heating season applied is 35 C and Crespectively. λ 1 and λ 2 are adopted based on the specification, and the Table 1 shows the summary of calculation parameters of single-borehole geothermal energy. Table 1. Calculation parameters of single-borehole geothermal energy. λ 1 λ 2 λ 3 r 1 r 2 r 3 r 4 L T 1 T 4 W m -1 K -1 m C.42 1.5 2.62.21.25.75 3 35/ 19.83 The single-borehole geothermal energy of the typical m borehole could be computed by Equ.1, are 4kW (cooling) and 5kW (heating) in Chongqing, and the heat transfer rate per meter of the corresponding borehole in the cooling season is 4 W/m, and that in the heating season is 5 W/m. 3. THERMAL UNBALANCE OF GSHP SYSTEMS GSHP borehole extracts energy from underground rocksoil mass through borehole heat exchangers, its heat inject and heat release in the two seasons of winter and summer tend to be different, leading to thermal unbalance. The longterm unbalance between heat inject and heat release will induce in the constant deviation of rock-soil temperature from initial temperature, and gradual decline in system operation efficiency of ground source heat pump, which has become an important issue for GSHP system design [6-8]. The rock-soil thermal unbalance arises from various elements, which usually present in three aspects [7], (i) it is rock-soil thermal parameters. GSHP adopts shallow geothermal energy, and mainly relies on the heat storage capacity of rock-soil mass. By contrast, the heat capacity of rock and soil is less, cannot extract or store more energy, so heat exchange rate is lower; (ii) the difference of cooling and heating loads in each buildings. The climates in different areas of China vary greatly, so the all-year cooling and heating loads of buildings are non-equal, and the all-year ground heat exchanger shows inconsistent heat inject and heat release for underground soil and rock, thus forming heat stack. According to Thermal Design Code for Civil Building [9], Chongqing has hot summer and cold winter, and the climate is characterized by extremely hot summer and wet and cold winter, so the cooling load of buildings is more than the heating load; (iii) the design of GSHP system. rock-soil mass is a heat accumulation body with huge volume, so the reduction in spacing between boreholes and single-borehole load both can alleviate effectively heat unbalance. This section builds the numerical model of borehole heat exchanger (BHE), selects the typical parameters of rock-soil thermal properties and heating and cooling loads from Chongqing to calculate the temperature response under different single-borehole loads, studies the thermal equilibrium, and analyzes the mutual effect between adjacent boreholes. 3.1. Numerical Model The section selects three-dimensional finite element model to simulate the heat exchange process of underground heat exchanger. FLUID116 linear elements in ANSYS can simulate the flow of fluid in buried pipe, without the increase of additional mesh in rock-soil unit, which is a simplified and efficient method []. Simulation of the finite element mesh of buried pipe of two U series connection with linear elements is shown in Fig. (1), after the fluid in buried pipe drains out of the outlet, it circularly flows into the buried pipe through a linear element. internal heat source q v Fig. (1). Sketch map of finite element mesh of BHE. Based on internal heat source qv in FLUID116 element through linear element and fluid convective heat transfer coefficient h, the process of circulating fluid heating can be simulated (Fig. 2).

An Assessment Methodology of Shallow Geothermal Energy Projects The Open Fuels & Energy Science Journal, 214, Volume 7 171 Fig. (2). Skeleton of FLUID116 element. where internal heat source q v is the source item of heat conduction differential equation, and can be directly set in element parameters as ρc T t + u T i,i = λt, jj + q v (2) Convective heat transfer coefficient h can be determined by setting four parameters of N 1 ~N 4 in Nu element fitting equation as Nu = N 1 + N 2 Re N 3 Pr N 4 (3) Pr = v α = vρc λ ; Re = ud v ; h = Nu λ d 3.2. Calculation of Cooling and Heating Load In GSHP system, the cooling and heating loads of buildings directly relates to the heat extraction and heat inject volume of buried pipe (heat exchanger), hence, the design of ground source heat pump system shall be based on the all-year hourly dynamic load as well as all-year accumulative load, namely, all-year heat inject volume and heat extraction volume, as well as reasonable selection of unit capacity and number of buried pipes and numerical simulation under dynamic load. Based on the typical meteorological year of Chongqing, the heating season is from Dec. 5 to Mar. 7 (93 days), the cooling season is from May 3 to Sep. 27 (148 days). Air conditioning system opens 12h under simulated condition, and the rest time is temperature recovery period, without GSHP. Table 2 shows the several time nodes used for analysis of calculation results. Table 2. Pipe node: K, L convection h Fluid node: I, J Time nodes for heating/cooling process. Date Days (d) Process Details t Dec. 5 1 Start of heating t 1 Mar. 7 93 End of heating t 2 May 2 149 End of recovery t 3 Sep. 27 297 End of cooling (4) season. With a view to improving the utilization efficiency of boreholes, in terms of engineering, the working condition in heating season is adopted for design of the number of boreholes, and cooling tower is selected as auxiliary cold source or the heating recovery technology is adopted so as to reduce the heat extraction volume of buried pipe in cooling season, which is called Ground Source Heat Pumps (GSHP) system [11]. On one hand, the GSHP system can reduce or eliminate underground thermal unbalance; on the other hand, it can also reduce the number of boreholes, and has good economic benefit. When dynamic load is calculated, designed cooling and heating load is usually selected based on building type and meteorological parameter and then converted into the dynamic load of buried pipe through the COP value of heat pump unit [12]. This section calculates dynamic loads a and b according to the meteorological data of Chongqing in typical meteorological year. The heat transfer rate per meter for the corresponding borehole of dynamic load a is 5 W/m during heating season, while the heat transfer rate per meter is 1 W/m during cooling season (Fig. 3), with accumulated cooling and heating load ratio of 2.; the heat transfer rate per meter for the corresponding borehole of dynamic load b is 5W/m during heating season, while the heat transfer rate per meter is 8W/m during cooling season (Fig. 4), with accumulated cooling and heating load ratio of 1.5. The starting point for the calculation cycle of dynamic load is t (Dec. 5). q (W/m) 12 9 6 - -6 6 12 18 24 36 t (d) Fig. (3). Annual dynamic load (a) in Chongqing. q (W/m) 12 9 6 The section has acquired the heat transfer rate per meter in cooling season and heating season is respectively 4 and 5 W/m, while Chongqing has hot summer and cold winter, where the cooling load of buildings is more than heating load. Therefore, the number of boreholes required in cooling season will be remarkably greater than that in heating - -6 6 12 18 24 36 t (d) Fig. (4). Annual dynamic load (b) in Chongqing.

172 The Open Fuels & Energy Science Journal, 215, Volume 8 Shuang et al. 3.3. Calculation Simulation for Single-Borehole Model According to the parameters in Table 1, build numerical model for m buried pipe, input the two dynamic loads in Figs. (3, 4) for calculation, and analyse the average water and rock-soil temperature of buried pipe. 3.3.1. Dynamic Load a The designed heat transfer rate per meter for the buried pipe of dynamic load a is 5 W/m, accumulated cooling and heating load ratio is 2., and calculation period lasts for one year. The average water temperature variation is showed as in Fig. (5) and the average water temperature at time nodes of Table 1 are listed in Table 3. Fig. (5). Average water temperature of buried pipe under dynamic load a (one year). Table 3. Average water temperature of buried pipe at time nodes under dynamic load a. Time (d) t t 1 t 2 t 3 t 4 Average water T. ( C) 19.8 13.7 19.2 22.2 2.5 According to the results of Table 3 and Fig. (5), the lowest water temperature is 11.6 C during heating season and the highest water temperature is 37.2 C during cooling season. After one-year cooling and heating, the average water temperature increases by.7 C and the heat exchange efficiency falls. 4 35 25 2 15 21 19 17 15 13 6 12 18 24 36 Fig. (6). Ground temperature diffusion curve for dynamic load a. t t1 t2 t3 t4 2 4 6 8 12 r / m After one operation cycle (Fig. 6), the temperature diffusion distance of the single-borehole model is about 5m and the temperature variation amplitude for the place 2m away from the borehole is about 1.5 C, with significant heat accumulation. And the rock-soil temperature fails to be recovered during recovery period. For further consider the accumulative effect of cooling and heating loads, the calculation duration is determined to be five years, with other model parameters constant. the average water temperature variations of buried pipe can be seen in Fig. (7). The highest average water temperature of buried pipe is 4. C during the cooling season within the fifth periodic year, which does not comply with relevant provisions on GSHP. The system cannot function correctly. It needs to be indicated that as a matter a fact, the water pump has stopped working during the recovery period and fluid in the pipe stops flowing. Theoretically, the flow velocity of numerical model should decrease to zero. However, relative to the surrounding rock and soil, the volume of fluid in pipe is so small that its temperature after long-term recovery period will be equal to the surrounding rock-soil temperature although the fluid is static. Therefore, the error can be ignored. 4 34 28 22 16 365 7 95 146 1825 Fig. (7). Average water temperature of buried pipe under dynamic load a (five years). 3.3.2. Dynamic Load b The designed heat exchange amount per liner meter for the buried pipe of dynamic load b is 5 W/m, with accumulated cooling and heating load ratio of 1.5. Fig. (8) describe for the average water temperature variations after ten-year operation. The average water temperature range is almost the same every year during periodic years, namely, 12~ C (Fig. 8). When the time reaches 365 days, the average water temperature of buried pipe is 19.87 C. Relative to the starting ground temperature, it increases by.7 C only, there is no hot stack, and the heat exchange efficiency of buried pipe has not decreased. The variations of rock-soil temperature with time at the place 3m away the buried pipe is showed in Fig. (9). After the system has worked for 1, 5 and years, the rock-soil temperature at the place 3m away from the buried pipe is 2., 2.2 and 2.3 C respectively, which reflects the heat storage and exchange capability of rock-soil mass.

An Assessment Methodology of Shallow Geothermal Energy Projects The temperature can be recovered within certain period and heat is not accumulated in rock-soil mass. The Open Fuels & Energy Science Journal, 214, Volume 7 173 2# 2#孔 borehole T/ 25 2 15 E L 1# borehole 1#孔 r=3 m ground temp. r=3m地温 365 7 95 146 1825 219 2555 292 3285 365 Fig. (). Skeleton for finite element grid of group borehole model. t /d Fig. (8). Average water temperature of buried pipe under dynamic load b (ten years). 2.4 2.2 T/ 2. 19.8 D E 19.6 T C 19.4 365 7 95 146 1825 219 2555 292 3285 365 t /d Fig. (9). Rock-soil temperature variations under dynamic load b (ten years). A R The calculation comparison for two dynamic loads indicates that when the designed heat transfer rate per meter of buried pipe is 5 W/m, and it is reasonable when the accumulated cooling and heating load ratio is 1.5, because it can ensure the system keeps working in a long time; by contrast, when the accumulated cooling and heating load ratio is 2., the cooling and heating unbalance is beyond the heat storage and exchange capability of rock and soil, thus resulting in the heat unbalance of rock and soil and failure of the ground source heat pump system. T E R A Similarly, extract the rock-soil temperature at the place 3m away from borehole 1#, and the temperature change along with time is shown as Fig. (13). The rock-soil temperature at the place 3m away from the buried pipe is respectively 2.2 C and 2.2 C after the system has operated for one and five years, which indicates that rocksoil temperature in group borehole model has certain range of accumulative temperature rise compared with the starting ground temperature due to influence of nearby borehole and realizes 2.2 C after five periodic years, however, it fails to exert remarkable influence on heat exchange efficiency of underground heat exchanger. 26 It is not typical to analyse rock-soil temperature change with single-borehole model when the underground thermal equilibrium analysis is conducted. In order to save floor space, the layout of buried pipe is usually concentrated in engineering, which not only generates thermal disturbance and results in superposition of temperature field, but shortens thermal diffusion radius of borehole, thus accelerating the change of rock-soil temperature. 22 T/ 3.4. Computational Simulation of Group Borehole Model Group borehole model for 9 boreholes are built in this section, with spacing of 6m (Fig. ), other model parameters are the same as the last section- heat exchange process of buried pipe is simulated after input of dynamic load b. C I T R In group boreholes model, borehole 1# is located at the center, and its heat exchange process is greatly influenced by nearby boreholes; borehole 2# is seated at corner, relatively speaking, its heat exchange process is closer to singleborehole model. The average water temperature of 1# borehole and 2# borehole after five years operation is respectively shown as Figs. (11) and (12). The results show that the average water temperature of buried pipe for boreholes 1# and 2# borehole is basically consistent with the result of single-borehole model in Fig. (8), with both of deviations less than.1 C thus it can be considered that 6m spacing of borehole is enough to ensure the heat exchange efficiency of buried pipe free from the influence of nearby boreholes under parameter of the dynamic load and rock-soil thermal performance. 18 14 365 7 95 146 1825 t/d Fig. (11). Average water temperature of buried pipe of group borehole model 1# borehole (five years).

174 The Open Fuels & Energy Science Journal, 215, Volume 8 Shuang et al. 21. Fig. (12). Average water temperature of buried pipe of group borehole model 2# borehole (five years). 26 22 18 14 21. 2.6 2.2 19.8 19.4 19. 18.6 365 7 95 146 1825 Fig. (13). Change of rock-soil temperature of group borehole model under dynamic load b with time. For further analysis on rock-soil temperature field, obtain a profile at the center of group borehole model, and extract rock-soil temperature at depth of H=5m, and the temperature of profile increases along with time. The curves in Fig. (14) are respectively named as the rock-soil profile temperature at the end of 1st, 2nd, 3rd, 4th and 5th year. In the central (r= m), it is borehole1#, at the distance to central (r=±6 m), there are two boreholes nearby 1#. It is known from the Fig. (). The temperature distribution of rock-soil among boreholes has become average after a year operation, and the temperature declines rapidly in the rock-soil mass outside the borehole. CONCLUSION 365 7 95 146 1825 In combination with computational equation and numerical model of single-borehole geothermal energy, the paper proposes an evaluation methodology for shallow geothermal energy resources. Taking GSHP system in Chongqing as an example, the paper calculates the singleborehole geothermal energy for m boreholes, and builds three-dimensional numerical model for borehole, calculate the dynamic load of two different accumulative cooling and heating load ratios and compare heat exchange process of buried pipe system between single borehole and group boreholes, and conduct analysis on underground thermal equilibrium. 2.8 2.6 2.4 2.2 2. 19.8 19.6-18 -12-6 6 12 18 r / m Fig. (14). Change of rock-soil profile temperature of group borehole model under dynamic load b. (1) According to the proposed equation in regulations, heat transfer rate of the typical borehole in Chongqing in cooling season is 4 W/m, and that in heating season is 5 W/m. (2) Through the calculation of two dynamic loads, when accumulative cooling and heating load ratio is 1.5, which is reasonable when the heat transfer rate of buried pipe is designed as 5 W/m, it can ensure long-term operation of the system. When the accumulative cooling and heating load ratio is 2., cooling and heating load unbalance will exceed the heat storage and heat exchange capacity of rock-soil itself, resulting in thermal unbalance of rock-soil and quick invalidation of ground source heat pump system. (3) Comparison between single borehole and group borehole models, the distance between boreholes is 6m which can ignore the heat exchange influence from nearby boreholes. The temperature distribution of rock-soil among boreholes is uniform after a year, and rock-soil temperature has a certain accumulative compared with the starting ground temperature, it can almost rise 2.2 C after five years. CONFLICT OF INTEREST The authors confirm that this article content has no conflicts of interest. ACKNOWLEDGEMENTS This work is supported by the Fundamental Research Funds for the Central Universities (FRF-TP-14-33A1). REFERENCES t=1 2 3 4 5 a [1] American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). 211 ASHRAE Handbook: Heating, Ventilating, and Air-Conditioning Applications. Atlanta, USA, ASHRAE 211. [2] H. Sachs, Geology and drilling methodsfor ground-source heatpump system installations: An introductionfor engineers, Atlanta, USA, ASHRAE 22.

An Assessment Methodology of Shallow Geothermal Energy Projects The Open Fuels & Energy Science Journal, 214, Volume 7 175 [3] Ministry of Land and Resources of the People s Republic of China. DZ/T 225-29. Technical Regulations for Shallow Geothermal Energy Investigation and Evaluation. Beijing: Standards Press of China, 29. [4] X. Y. Liu, Q. Y. Peng, J. X. Tao, Research on Investigation of Shallow Geothermal Energy Resources of Chongqing, Chongqing Architecture, vol. 13, no. 6, pp. 53-56, 214. [5] Ministry of Housing and Urban-Rural Development of the People s Republic of China. GB 5366-25. Technical Code for Ground Source Heat Pump System. Beijing, China Architecture & Building Press, 29. [6] S. Q. Wang, X. Zhang, Q. Bao, J. Liu, J. Gao, Research on Influence of Load Unbalance Ratio on Soil Temperature Field under Different Buried Pipe Layout Form, Building Science, vol. 8, pp. 64-67, 2. [7] W. B. Yang, S. S. Zhang, Research Status and Key Problem of Soil Thermal Unbalance of Ground Source Heat Pump Operated in District with Unbalanced Cooling and Heating Load, Fluid Machinery, vol. 42, no. 1, pp. 8-87, 214. [8] S. P. Kavanaugh, A design method for hybrid groundsource heat pumps, ASHRAE Transactions, vol. 4, no. 2, pp. 691-698, 1998. [9] Ministry of Housing and Urban-Rural Development of the People s Republic of China. GB5176-93, Thermal Design Code for Civil Building, Beijing, China Planning Press, 1993. [] X. L. Zhong, Analysis and Design on Geothermal Pile Foundation, Master Thesis, Beijing, Tsinghua University, 2. [11] G. Phetteplace, W. Sullivan, Performance of a hybrid GCHP system, ASHRAE Transactions, vol. 4, no. 1, pp. 763-77, 1998. [12] X. C. Chen, H. L. He, R. Wang, W. L. Xu, J. Hao, W. Zeng, Y. G. Pan, Checking Calculation for Design of Ground Source Heat Pump System-CAG Innovation & Science Research Demonstration Building, Journal of Heating Ventilating & Air Conditioning, vol. 3, pp. 6-65, 214. Received: January 6, 215 Revised: May 2, 215 Accepted: June 19, 215 Shuang et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/ by-nc/3./) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.