Civil Engineering. Punching of reinforced concrete flat slabs with holes and shear reinforcement. Engenharia Civil. Abstract. 1.

Similar documents
COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Comparison of One-way and Two-way slab behavior. One-way slabs carry load in one direction. Two-way slabs carry load in two directions.

SAFETY ON PUNCHING OF PRESTRESSED FLAT SLABS

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

RESILIENT INFRASTRUCTURE June 1 4, 2016

Topology Optimization of Reinforced Concrete Plane Frames

Shear studs in slab-column connections with rectangular column

Punching shear resistance of reinforced concrete slabs under pneumatic loads

CHAPTER 4 PUNCHING SHEAR BEHAVIOUR OF RECYCLED AGGREGATE CONCRETE TWO WAY SLABS

SEISMIC PERFORMANCE OF FLAT-SLAB SHEAR REINFORCEMENT

A NEW CFRP STRENGTHENING TECHNIQUE TO ENHANCE PUNCHING SHEAR STRENGTH OF RC SLAB-COLUMN CONNECTIONS

Use of Mortar Plaster and Reinforcement For Repairing and Stiffening of Non-Structural Masonry Walls

Two-way slabs. Flat plate with or without drop panels / capitals

Global Journal of Engineering Science and Research Management

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

The Use of Bolted U-Link Swimmer Bars in the Reinforced Concrete Beams

CUREe-Kajima Flat Plate 1 Kang/Wallace

Seismic Behaviour of RC Shear Walls

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 2, 2012

Seismic-Resistant Connections of Edge Columns with Prestressed Slabs

FLEXURAL CAPACITIES OF REINFORCED CONCRETE TWO-WAY BUBBLEDECK SLABS OF PLASTIC SPHERICAL VOIDS

REAL SCALE EXPERIMENTAL ANALYSES OF CIRCULAR HOLLOW SECTION MULTI-PLANAR STEEL TRUSSES

Punching shear in concrete reinforced flat slabs with steel fibers and shear reinforcement

ctbuh.org/papers A Study of Flat Plate Slab Column Connections with Shear Plate in Tall Concrete Building using Experimental and Numerical Analysis

Punching Shear Resistance of Flat Slabs By Shear Heads

Investigating the Use of Spliced Swimmer Bars as Shear Reinforcement in Reinforced Concrete Beams

PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA

10-COLUMNS: 10.1 Introduction.

Sabah Shawkat Cabinet of Structural Engineering 2017

AC : STUDENT FEEDBACK AND LESSONS LEARNED FROM ADDING LABORATORY EXPERIENCES TO THE REINFORCED CONCRETE DESIGN COURSE

DESIGN FOR PROGRESSIVE COLLAPSE 1

EXPERIMENTAL RESEARCH ON LOAD RESISTANCE PERFORMANCE OF CFT COLUMN/FLAT PLATE CONNECTION

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

VARIOUS TYPES OF SLABS

Failure Characteristics and Critical Punching Perimeter of High Strength Concrete Panels

Experimental investigation of reinforced concrete slabs with punching shear reinforcement

ON YIELD LINE ESTIMATES OF THE PUNCHING STRENGTH OF FULL PANEL UNBONDED POST-TENSIONED FLAT SLABS AT INTERNAL COLUMNS

13-14 May 2011 B.V.M. Engineering College, V.V.Nagar,Gujarat,India

TECHNICAL MANUAL. PSB Punching Reinforcement. Shear Reinforcement for Concrete Structures

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS

CONFINEMENT CAPACITY OF SQUARE AND CIRCULAR CONCRETE COLUMNS REINFORCED WITH PREFABRICATED CAGE REINFORCEMENT SYSTEM

Crossroads at Westfields Building II

SEISMIC PERFORMANCE OF POST TENSIONED INTERIOR SLAB-COLUMN CONNECTIONS WITH AND WITHOUT DROP PANEL

Progressive Collapse Mitigation in Flat-Slab Buildings

Reinforced concrete waffle flat slabs under shearing

BEHAVIOUR OF RCC FLAT SLAB STRUCTURE UNDER EARTHQUAKE LOADING

Tips For Designing Constructable Concrete Buildings

Study on Minimum Shear Reinforcement of Reinforced Concrete Flat Slabs

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

ISSN: Page 14

THE FORENSIC MEDICAL CENTER

INVESTIGATION OF FINITE ELEMENT MODEL OF SLAB COLUMN CONNECTIONS UNDER ECCENTRIC LOAD

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loading P.Rajaram 1 A.Murugesan 2 and G.S.

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Section A A: Slab & Beam Elevation

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

IJESRT. [Najmi, 2(5): May, 2013] ISSN: Keywords: Bent-up, Deflection, Beam, Crack, Stirrup

SEISMIC BEHAVIOR AND DESIGN OF STEEL SHEAR CONNECTIONS WITH FLOOR SLABS

Effect of web reinforcement on shear strength of shallow wide beams

Keywords: steel structures, cold-formed steel angles, structural stability, numerical analysis, non-linear analysis.

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Council on Tall Buildings

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

Design of Reinforced Concrete Slabs

FLAT PLATE AND FLAT SLAB CONSTRUCTION

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

twenty two concrete construction: flat spanning systems, columns & frames Reinforced Concrete Design Reinforced Concrete Design

Applications of sustainable post-tensioned concrete slabs

PUNCHING TESTS ON RC FLAT SLABS WITH ECCENTRIC LOADING

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

STRUCTURAL PERFORMANCE OF MIXED MEMBER COMPOSED OF STEEL REINFORCED CONCRETE AND REINFORCED CONCRETE

A STUDY COMPARISON OF DROP PANELS UNDER INFLUENCE OF PUNCHING SHEAR USING ANSYS.16.0

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Behavior of Reinforced Concrete Walls with Mesh Reinforcement Subjected to Cyclic Loading

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

twenty two concrete construction: flat spanning systems, columns & frames ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN

Replacement of Conventional Rebar With Non-Conventional Prefabricated Cage System in RC Column

TECHNICAL MANUAL. ARMATA Punching Reinforcement. Deformed Shear Reinforcement to Reduce Congestion

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

SEISMIC PERFORMANCE OF FLAT SLAB WITH DROP AND CONVENTIONAL SLAB STRUCTURE

EXPERIMENTAL ANALYSIS OF MECHANICAL BEHAVIOR OF LINTELS IN STRUCTURAL MASONRY

OPTIMAL SEISMIC DESIGN METHOD TO INDUCE THE BEAM-HINGING MECHANISM IN REINFORCED CONCRETE FRAMES

Advances in Structural Engineering

Numerical Analysis and Experimental Studies on Welded Joint for Buildings

Experimental Study of Composite Beams Made of Steel Tubes Filled with Concrete under the Confinement Effect of U-Links and Stud-Plate

EXPERIMENTAL INVESTIGATION OF THE JACK ARCH SLAB RETROFITTED BY CONCRETE LAYER

SIMPLE INVESTIGATIONS OF TENSILE MEMBRANE ACTION IN COMPOSITE SLABS IN FIRE

twenty two concrete construction: flat spanning systems, columns & frames Reinforced Concrete Design Reinforced Concrete Design

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Shear Behavior of RC Slender Beams with Corrosion-Damaged Stirrups

Punching shear behavior of Lightweight foamed RC slabs

INTERNATIONAL JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (IJCIET)

Comparative Study of Reinforced Concrete Flat Slabs with and without Openings using Finite Element Analysis

DUCTILITY OF T-SHAPE RC BEAMES STRENGTHENED BY CFRP SHEET ABSTRACT

BEHAVIOUR OF REINFORCED CONCRETE STRUCTURES IN FIRE

Transcription:

Civil Engineering Engenharia Civil http://dx.doi.org/10.1590/0370-44672017700022 Jales Almeida Silva Engenheiro Civil da Colmeia Consultoria e Projetos Goiânia Goiás Brasil jales.jas@gmail.com Marília Gonçalves Marques Professora-Mestre Universidade Federal de Viçosa - UFV Rio Paranaíba Minas Gerais Brasil mariliagmarques@outlook.com Leandro Mouta Trautwein Professor-Doutor Universidade Estadual de Campinas UNICAMP Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Departamento de Estruturas Departamento de Estruturas Campinas São Paulo Brasil leandromt@gmail.com Punching of reinforced concrete flat slabs with holes and shear reinforcement Abstract Punching shear is a possible type of failure that occurs in reinforced concrete flat slabs, which can develop with an ultimate load below flexural capacity. Several researchers have studied the punching resistance of flat slabs over recent years. Although they have made great advances, there are codes that show different approaches to a singular design. Some codes show that there exist contradictions, even in the simplest situations, such as concentric loads. Most codes prescribe empirical expressions based in a theoretical model to analyze punching strength, but for flat slabs with holes around the column and shear reinforcement there are divergences between codes, justifying research in this area. This paper presents an experimental analysis of nine square reinforced concrete flat slabs under concentric loading (width: 1800 mm; thickness: 130 mm). The main variables used in the tests were: a) two square openings (150 mm) adjacent to the smallest side of the column and b) the use of shear reinforcement containing 3 layers, with 6 or 8 elements in each layer and radially distributed around the column. The research concludes that openings adjacent to the column affect punching shear strength, while the correct use of the shear reinforcement can minimize and even compensate this loss. Keywords: punching, slabs, studs, holes. Ronaldo Barros Gomes Professor Titular Universidade Federal de Goiás - UFG Escola de Engenharia Civil e Ambiental Goiânia Goiás - Brasil rbggomes@gmail.com Gilson Natal Guimarães Professor Titular Universidade Federal de Goiás - UFG Escola de Engenharia Civil e Ambiental Goiânia Goiás - Brasil rgilson.natal@gmail.com 1. Introduction The conventional structure system (slab-beam-column), for some situations, has been substituted by the slab-column system in civil construction projects. The slab-column system does not have the support of the beams, where the slabs are supported directly onto the column. This structural concept brings advantages, such as facilitating the use of the formwork in order to reduce cuts influenced by beams. This produces greater agility in the construction process with a decrease in costs regarding material waste. The level of detail given to the reinforcement is simpler and consequently easier to execute, whereby there also exists the possibility of adapting the site for other ends due to the inexistence of beams. On the other hand, this structure does have its disadvantages in using flat slabs. As beams do not exist, there may occur a reduction in the global stability of the structure, and as the flat slab is normally less rigid than a conventional slab (with beams), it is open to greater vertical displacements, when compared to conventional slabs. According to code NBR6118:2014, a punching shear failure is an ultimate limit state near the concentrated forces, determined through reinforcement. Rupturing due to punching failure from a flat structural element such as a slab or foundation element can occur with the application of a concentrated force on a particular area of this element, producing an intense shear force in the region. The punching failure can occur in buildings in regions between the column and 407

Punching of reinforced concrete flat slabs with holes and shear reinforcement slab, where the column is supported on a slab. Another region that is also subject to damage through punching is the meeting point between the column and foundation. This damage may occur in an abrupt and fragile manner, without giving warning. Holes adjacent to the columns for the passage of ducts used for electrical and hydraulic installarions can aggravate the rupture through punching shear. Research performed in Brazil and the exterior evaluated the use of stud type reinforcement to increase resistance to punching. The studies evaluate slabs with variable loads, holes and bending moment. There have been research studies 2. Materials and methods This paper shows a summary of the experimental results for nine square reinforced concrete flat slabs with the same dimensions, and flexural reinforcement with a load on their center. All of the slabs were square with side lengths of 1800 mm and a thickness of 130 that resulted in some empirical formulations based on shear stress and control perimeter. A formulation is differentiated one from another basically in terms of position and form of the control perimeter. The first rational theory concerning punching was presented by KINNUNEN & NYL- ANDER (1960), based on circular slab trials without reinforcement. Ha et. al. (2015) studied eight flat slabs with round holes, varying the amount and position of the hole. The authors concluded that the amount and position modifies the failure surface mode. Holes adjacent to the column reduce the shear strength of the slabs, and holes positioned at the column corner mm (SILVA, 2003). A study is made of the central punching failure scenario, a common situation in the central columns of buildings with flat slabs, and with a symmetric load, which is transmitted to the slab without irregularity. The slabs and the adopted test can result in further reduction. In order to make the column/slab connection safer, an increase in the ductility and the resistance capacity of a flat slab s shear reinforcement is used to avoid punching. Research studies such as those by GOMES e REGAN (1999), ANDRADE (2000), SILVA (2003), SOUZA (2009) and BORGES (2013), FERREIRA (2010) e TRAUTWEIN (2011) demonstrate that the use of shear reinforcement can be extremely efficient in preventing punching failure, even to the point of changing the rupture due to flexure. This study aimed to provide increased punching resistance when using a shear reinforcement stud type, and when using an increased column perimeter. arrangement correspond to an area of negative bending on the column, approximately equal to 1/5 of the span in real scale and equivalent to a span of 4125 mm, considering a situation of internal column and symmetrical loading, as shown in Figure 1. Figure 1 Hypothetical frame featuring the region studied in ANDRADE (1999). 2.1 Characteristics of the trial slabs The main characteristics of the slabs are: a) effective height of 90 mm, b) the existence of two holes of 150 mm x 150 mm arranged adjacent to the column, c) the use of shear reinforcement (SR) with a radial distribution in 3 layers and diameter φ = 8 mm, d) dimensions of the column with a constant side "a" equal to 150 mm and the other side "b" 408 with values of 150 mm and 300 mm, as shown in Figure 2. The high ratio flexural reinforcements were adopted to avoid flexural failure. In the slabs without holes the ratio was 1.45 % and in the slabs with holes was 1.57 %. This difference is due to the addition of two perpendicular bars in the direction of the holes. Slabs L1 and L2 are the reference slabs, without holes and shear reinforcement, slabs L3, L4, L7 and L8 have holes adjacent to the column, being that L7 and L8 are with shear reinforcement. Slabs L5 and L6 do not have holes but have shear reinforcement. Slab L9 has a circular section column without holes or shear reinforcement, Table 1.

Figure 2 Main features of the slabs under study. Source: Silva, 2003 Slab Dimensions of column a (mm) b (mm) Effective height d (mm) ρ (1) (%) Hole Shear Reinforcement (SR) stud L1 150 150 90 1.45 no no L2 150 300 90 1.45 no no L3 150 150 90 1.57 yes no L4 150 300 90 1.57 yes no L5 150 150 90 1.45 no yes (2) L6 150 150 90 1.45 no yes (2) L7 150 150 90 1.57 yes yes (3) L8 150 300 90 1.57 yes yes (3) Table 1 Slab features. L9 - - 90 1.45 no no (1) ρ= (ρ x ρ y ), reinforcement rate, calculated with a width equal to 1034 mm; (2) 8 lines; (3) 6lines. 2.2 Test arrangement The load was applied upward from a jack, with a capacity of 1500 kn, placed at the middle of the bottom face of the slab, and the reactions were provided by four ties fixed to the strong floor and through a set of steel beams (beams 1 and 2 of Figures 3 and 4) onto a reaction slab at each edge. This reaction was performed through 8 equidistant points positioned in a circumference with a radius equal to 825 mm. 2.3 Details of the tested models The flexural reinforcement used on the slabs presents different details due to the holes and loading areas (columns). For the slabs without holes, the negative reinforcement (top) is composed of an orthogonal mesh of 19 bars of 12.5 mm in diameter (CA-50) in each direction. The positive reinforcement (bottom) is composed of an orthogonal mesh of 11 bars of 6.3 mm in diameter (CA-50 steel) in each direction. In the U-type form, 19 bars of 6.3 mm in diameter were added at both ends of each flexural reinforcement to help the anchorage and were fixed on each bar. 409

Punching of reinforced concrete flat slabs with holes and shear reinforcement Figure 3 Test arrangement (Top view). Only slabs L5, L6, L7 and L8 used shear reinforcement (Table 1) of the stud type, where steel bars CA-50 (φ = 8 mm and a length of 105 mm) were welded at their extremities to steel plates of 30 mm in length and 100 mm in thickness. These studs were made through a manual welding process with a coated electrode of type OK 48.04 of 3.5 mm from ESAB. Figure 5 shows Figure 4 Test arrangement (side view). a scheme with the dimensions of the shear reinforcement and a photograph that illustrated the positioning of the shear reinforcement in relation to the flexural reinforcement. 410 Figure 5 Shear Reinforcement.

In all slabs, the concrete had cylinder compressive strength between 39.4 MPa and 49.4 MPa. The mix proportion to 3. Results and discussion weight ratio used to fabricate the concrete for all slabs was calculated by the company Betonmaster Concrete and Artefacts from Cement Ltda. The superplasticizer additive was added minutes before concreting to improve the workability of the mixture. The experimental results included the ultimate load, mode of failure and cracking pattern. 3.1 Load and failure mode The loads were applied in increments and tested up to failure for all slabs and had punching failure. The failure load adopted was the maximum value Dimensions of column reached in the load cell, Table 2. Slab f c (MPa) a (mm) b (mm) C (1) (mm) ρ (%) Hole (2) A.C. (3) P u (kn) L1 39.6 150 150 600 1.45 no no 273 L2 40.4 150 300 900 1.45 no no 401 L3 39.4 150 150 600 1.57 yes no 225 L4 39.6 150 300 900 1.57 yes no 350 L5 49.0 150 150 600 1.45 no yes (4) 420 L6 49.4 150 150 600 1.45 no yes (4) 452 L7 40.0 150 150 600 1.57 yes yes (5) 325 L8 40.8 150 300 900 1.57 yes yes (5) 350 L9 42.3 402 (6) 1262 1.45 no no 525 (1) Perimeter of the column; (2) Two holes of 150x150 mm placed adjacent to the side of the column; (3) Shear reinforcement of the stud type, f = 8mm, with 3 layers; Table 2 Slab Rupture Loads. (4) 8 lines; (5) 6 lines; (6) Circular column, value of diameter of the column. The failure load of the tested slabs obtained results depending on the perimeter of the column, and the number of holes with the use or not of shear reinforcement. The slabs with the same characteristics with higher perimeter and shear reinforcement increased the failure loads of the slabs. For slabs L1, L2 and L9, without holes and shear reinforcement, a notable increase was observed in the failure load of slabs L2 of 46 % and L9 92 %, when compared to the rupture load of slab L1. This increase occurs, in all probability, because of the increase of the column perimeter on slab L5. The strength drop due to the existence of the two holes arranged adjacent to the smaller sides of the column, in relation to the slabs without holes (L1-b/a = 1, L2-b/a = 2), was 48kN and 51kN, respectively. Note for these models that the load loss was practically constant for a "b/a" ratio of less than 2. The reduced failure load due to the existence of holes placed adjacent to the column and without shear reinforcement, L3 and L4, were 18 % and 13 % respectively. However, when shear reinforcement is used, as with L7, the load increased by 16 % compared to the L1 reference slab. In terms of the slab without the hole but with shear reinforcement (L5), the increase of the failure load reached 35 %. When comparing the failure loads of the slabs L8 (with two holes and shear reinforcement) and L4 (with two holes and without shear reinforcement), it was verified that the shear reinforcement adopted was ineffective, since it did not contribute any increase in the failure load. Slabs L1, L2 and L12 showed signs of failure surface on the face of the column in two directions. The failure surface around the holes of slabs L3 and L4 initiated at the column face and extended to the other side of the hole. In the slabs that had shear reinforcement (L5, L6, L7 and L8), the failure surface initiated after the last layer of studs, constituting an external rupture. 3.2 Cracks The first visually apparent cracks were radial and these occurred in all slabs for a load between 50 kn and 100 kn, as presented on Table 3. Noted here is that the first radial crack started between of 17 % to 19 % of the failure load for slabs without holes, and from 22 % to 24 % of the ultimate load for slabs with holes. Figure 6 presents the crack pattern after the failure of slabs L1, L3 and L4. 411

Punching of reinforced concrete flat slabs with holes and shear reinforcement Slab Pu (kn) Pu (1) (kn) Pu /Pu (%) L1 273 50 18.3 L2 401 75 18.7 L3 225 50 22.2 L4 350 75 21.4 L5 420 75 17.6 L6 452 75 16.6 L7 325 75 23.1 L8 350 75 21.4 L9 525 100 19.0 (1) Load at the moment of the first visible radial crack Table 3 Comparisons on the appearance of the first radial crack. After the rupture, the slabs presented a similar development regarding radial cracks and with some difference in 4. Conclusions relation to the circumferential cracks. For slabs L3 and L6, the appearance of the circumferential cracks was considerable, Figure 6 Crack pattern after the failure of slabs L1, L5, L7 and L8. practically surrounding the entire loading area and the radial cracks arrived near the supports. 412 The design of reinforced concrete flat slabs requires special care for punching shear, especially with the presence of holes near the column. The ultimate load at these columns supporting flat slabs may be distinctly below the flexural capacity and with a brittle failure. All the slabs tested had punching shear failure, and the research herein was directed to this failure mode. The slabs with shear reinforcement presented external failures, with the failure surface initiating after the last layer of the shear reinforcement. The existence of holes adjacent to the column can affect the strength to the punching of flat slabs. Results show that the failure load decreased in up to 13%, when the strength portion of the concrete is reduced in the critical region, with two square holes of 150 mm side by side. The process associated with the appearance of radial cracks and the development of circumferential cracks followed differentiated characteristics for slabs with and without holes and shear reinforcement. For slabs without shear reinforcement, the circumferential crack appeared at 26 % to 48 % of the failure load, and at 33 % to 86 % for the slabs with shear reinforcement. The results also show that the use of this shear reinforcement can be a possibility to increase the punching strength in flat slabs with holes. This increase may even be higher when compared to slab without shear reinforcement and without holes (19 % - from slab L7 to L1). The analyses performed in this study were limited by the slab dimensions (length and height) and by the size of the column. Different positions and dimensions of holes and shear reinforcement can contribute more towards understanding the problem of punching.

References Received: 07 february 2017 - Accepted: 03 july 2017. ANDRADE, M.A.S. Punching of flat slabs study of the positioning of shear reinforcement in relation flexural reinforcement. Goiânia: Escola de Engenharia Civil / UFG, 1999. (Dissertação de Mestrado). ANDRADE, J.L.S. de. Experimental investigation on open stirrups with different inclinations in reinforced concrete flat slabs. Brasília, Brazil: Universidade de Brasília, 2000. 142 p. (MSc. Thesis). BORGES L.L.J., MELO G.S., GOMES R.B. Punching shear of reinforced concrete flat plates with openings. ACI Structural Journal, v.110, n. 4, p. 1-10. July-Aug. 2013. BRAZILIAN ASSOCIATION OF TECHNICAL STANDARDS (ABNT). (2014) NBR 6118: Standard for concrete Stuctures Design (in Portuguese). Rio de Janeiro. GOMES, R. B.; REGAN, P. E. Punching resistance of RC flat slab with shear reinforcement, Journal of Structural Engineering. New York, EUA, v.125, p. 684-692, 1999. FERREIRA, M. P. Punching of concrete flat slabs with shear reinforcement and unbalanced moment. Brasília: Universidade de Brasília, 2010. 299 p. (Tese de Doutorado em Engenharia Civil). HA,T., LEE, M., PARK, J., KIM, D. Effects of openings on the punching shear strength of RC flat-plate slabs without shear reinforcement. The Structural Design of Tall and Special Buildings. John Wiley & Sons, Ltd. p. 895-911, 2015. KINNUNEN, S., NYLANDER, H. Punching of concrete slabs without Shear Reinforcement. Civil Engineering n. 6. Stockholm, Transactions of The Royal Institute of Technology. n. 158, 1960. 112 p. REGAN, P.E. Punching tests of concrete slabs with riss star shear reinforcement for riss AG. London: School of Architecture & Engineering, University of Westminster, 1993. SILVA, J.A. Punching of flat slabs rectangular columns, openings and shear reinforcement. Goiás: Universidade Federal de Goiás, 2003. (MSc. Thesis). SOUZA, R. M., MELO, G. S., GOMES, R. B. Punching shear in reinforced concrete with hole adjacent to the column and moment transfer. In: BRAZILIAN CONCRE- TE CONGRESS - IBRACON, 51, 2009. Curitiba, Brazil. TRAUTWEIN, L. M., BITTENCOURT, T. N., GOMES,R.B., BELLA, J.C.D. Punching strength of flat slabs with unbraced shear reinforcement. ACI Structural Journal, 2011. 413