Uni-Just & Stak-Cap Pedestal System

Similar documents
IPE WOOD DECK TILES National Distribution SPEC - SECTION 07760

ROOF PAVER SYSTEM National Distribution SPEC - SECTION 07760

Tile Tech Porce-PaveTM Paving America one step at a time!

AGA Roof Deck Pavers. AGA Concrete Paver. Technical. Pavers: Hydraulically pressed concrete pavers: 460 tons of pressure.

Tile Tech IPÊ-Tile. Paving America one step at a time! MANUFACTURER OF IPÊ WOOD TILES & ADJUSTABLE PEDESTAL SYSTEMS

Mbrico Tile Rooftop/Raised Floor Installation Guidelines

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Level.It L-Series Specification SECTION Plastic Structural Assemblies PART 1 GENERAL

DETAIL INSTRUCTION No. 1

SECTION ROOF PEDESTAL PAVER SYSTEM

Contract18. Vitrified paving FLAT ROOF BALCONY ROOF TERRACE DISPLAY AREA

4 EXTREME FOUNDATION PANELS

2018

I N S T A L L A T I O N

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

SPECIFICATIONS Section Cantilevered Walkway Cover

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Versadjust V-Series Specification SECTION Plastic Structural Assemblies PART 1 GENERAL

Versadjust V-Series Specification SECTION Plastic Structural Assemblies PART 1 GENERAL

10 EXTREME BASEMENT PANELS

Elevations Roof Deck and Tile Systems

skydeck usa, LLC pavers. pedestals. green roof SKYJACK Adjustable Pedestal System Taking the P.I.A. out of paver installs

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

Roofgard Paving Support System

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

CONCRETE TILE PAVERS

Light-Metal Roof Edge, Raised

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

Bison Innovative Products 1975 W. 13 th Ave. Phone February 2012 P.O. Box Toll Free Denver, CO Fax

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems

Shower Tray - Timber Floors

Exterior System installation instructions

Building permits are not required for patios made of concrete or pavers on grade.


Installation Instructions

ZS880 Linear Shower Drain Installation Instructions

WEIGHT PER PIECE (LBS.)

COUNTY BLOCK. Construction Guidelines on County Block Steps. Special Considerations When Building Steps. Natural Beauty Absolute Strength

SPECIFICATIONS Section Gable Walkway Covers

INSTALLATION CHECKLIST 2 ND EDITION. Fox Blocks Abbott Drive Omaha, NE

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

DEXERDRY INSTALLATION INSTRUCTIONS - PAGE - 1

ASHLEY AVE. PARKING GARAGE CHILLER TOWER ROOF REPAIRS

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

SECTION MANUFACTURED ROOF EXPANSION JOINTS

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

NRDCA GUIDELINE FOR APPLICATION of CEMENTITIOUS WOOD FIBER ROOF DECK SYSTEMS

Detailed Deck Building

Suggested Materials and Tools:

1 PVC or ABS drain with strainer

GEOGRID CONNECTION DETAIL OLYMPIA RADIUS UNIT

ROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

Leveling Foot RB210. Leg Extender RLT66

Tremline. Fascia System. Installation Procedures

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

GroundTrac. Installation Manual

A-ONE Insulated Forms Installation Manual

Plans created at home centers are acceptable for plan review. These computer designs do not allow homeowners to duplicate conditions at their home.

BioPrism Solid Surface

Bison Innovative Products 1975 W. 13 th Ave. Phone February 2012 P.O. Box Toll Free Denver, CO Fax

SECTION NON-STRUCTURAL METAL FRAMING

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Interior Hangers. Application

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

AXIOM Building Perimeter System Assembly and Installation Instructions

Revision Date: April 01, Premier Vinyl Enclosure

SECTION ROOF SPECIALTIES

Suggested Materials and Tools:

(800) (562) A Subsidiary of the International Code Council

Basic Suspension Systems

Silva Cell. Silva Cell Two-Deep Installation Instructions. Helping Trees Live in the Urban Environment

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

Fig. 1 - Standard Clevis Hanger

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

Five Stone System. Trench Depth Compactible Rock. Foundation. 57 lbs 41 lbs 31 lbs 47 lbs. Patent Pending. Approximate Weight

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

IMPORTANT: Levelness of the walk-in floor is critical. If the floor is not level, vertical panels cannot be aligned properly.

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number

Insulated Concrete Forms (ICFs)

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

INSTALLATION MANUAL for DARVOLEX D (decking) Relief profile D6 lip metal Screw 3.9x32. Smooth profile D51 underlying profile tray Clip PVC

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

RS24-10 Single-Section Skylight System

Rack-in-a-BoxTM INSTALLATION MANUAL

AL13. Intro. Vol 2 AL13. architectural panel system. Version 1. patent pending

Architectural Wall Products Guide Specifications

Attached are examples of drawings which are intended as a GUIDE ONLY!!

DECK PERMIT APPLICATION

Transcription:

Tile Tech Pedestal Uni-Just & Stak-Cap Pedestal System Single Model Design PVC Pipe Adjustable Screw Adjustable Self-Leveling Pat. # 8,453,39 & Pat. Pen Stackable HYBRID PEDESTAL SYSTEM - TECHNICAL DETAILS

TILE TECH PEDESTAL SYSTEM TABLE OF CONTENTS Toll Free: 888-380-5575 Fax: 23-380-556 3. COMPONENTS LIST 6. DIAGONAL PERIMETER APPLICATION 4. COMPONENT ASSEMBLY INSTRUCTIONS STAK-CAP PEDESTALS 7. LOW HEIGHT PEDESTAL APPLICATION 5. INSTALLATION INSTRUCTIONS STAK-CAP PEDESTALS 8. DRAIN PEDESTAL APPLICATION 6. COMPONENT ASSEMBLY INSTRUCTIONS UNI-JUST PEDESTALS 9. PERIMETER EDGE RESTRAINT METAL FLASHING AND WOOD FASCIA CONTAINMENT 7. INSTALLATION INSTRUCTIONS UNI-JUST PEDESTALS 20. PERIMETER EDGE RESTRAINT STEP-DOWN AND GREEN ROOF CONTAINMENT 8. BASE SLOPE COMPENSATION 2. STEP-DOWN PEDESTAL APPLICATION 9. UNI-SHIM APPLICATION 22. IPE WOOD TILE APPLICATION 0. PEDESTAL COMBINATION & CONFIGURATION 23. WOOD TILES 20X20 DETAILS. SAMPLE DECK LAYOUT - OVERVIEW 24. WOOD TILES 24X24 DETAILS 2. SAMPLE INITIAL INSTALLATION 25. JOIST DECK PEDESTAL APPLICATION 3. THRESHOLD PEDESTAL APPLICATION 4. RADIUS PEDESTAL APPLICATION 26. WIN-LOC PAVER PAVER LOCK DOWN SYSTEM FOR WIND UPLIFT. 27. HEX-TRAY PAVER SNOW MELT SYSTEM. 5. CORNER PEDESTAL APPLICATION COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 2

TILE TECH PEDESTAL SYSTEM COMPLETE PRODUCT LINE & COMPONENTS LIST PRODUCT LINE MODEL NUMBER DESCRIPTION SPACERS /8 & /4 ALLOW FOR /8 SPACING GAP BETWEEN PAVERS FOR DRAINAGE. TABS A PERFORATED FOR EASY REMOVAL. UNI-SHIM - /8 & /6 USED FOR FINE TUNING OF INDIVIDUAL PAVERS. CAN BE USED ON TOP OR BOTTOM OF PEDESTALS. CAN BE STACKED & BROKEN IN TO QUARTERS OR HALVES. STAK-CAP USED OF LOW HEIGHT REQUIREMENTS. ROTATE AND STACK CAPS FOR SLOPE & HEIGHT ADJUSTMENT. CAN ALSO BE USED WITH PVC PIPE TO REACH 6 MAX. UNI-CAP SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE. ALIGN & LOCK TO UNI- INSERT. UNI-INSERT -75 (3/4 ) UNI-INSERT -50 (-/2 ) UNI-COLLAR USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES- TAL. SCREWS IN TO UNI-COLLAR. PROVIDES ADDI- TIONAL 3/4 OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE. USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES- TAL. SCREWS IN TO UNI-COLLAR. PROVIDES ADDI- TIONAL -/2 OF HEIGHT ADJUSTMENT IN ADDITION TO PVC PIPE. USED FOR SCREW HEIGHT ADJUSTABILITY OF PEDES- TAL SYSTEM. COMPRESSION FITS ON TO TOP END OF PVC PIPE. UNI-BASE BASE SLOPE PLATE (BSP) BUFFER PAD USED AS BASE OF PEDESTAL SYSTEM. COMPRESSION FITS ON TO END OF PVC PIPE. CAN ALSO BE USED WITH UNI-INSERT FOR LOW HEIGHT APPLICATIONS. LARGE SURFACE AREA PROVIDE ADDED STABILITY. USED FOR SLOPE COMPENSATION AT BASE OF PEDESTALS. EACH PLATE COMPENSATES FOR /4 PER FOOT (2%) SLOPE AND ADDS 3/8 TO THE OVERALL HEIGHT OF PEDESTAL. MAXIMUM OF FOUR PLATES MAY BE STACKED FOR COMPEN- SATION OF UP TO PER FOOT (0-8%) SLOPE. PROVIDES PROTECTION TO WATERPROOFING MEM- BRANE FROM WEAR AND PROVIDES SLIP RESISTANCE TO PEDESTAL. ATTACHES TO BOTTOM OF BASE. ALIGN PERIMETER NOTCHES WITH CHALK LINES. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 3

STAK-CAP PEDESTAL SYSTEM COMPONENT ASSEMBLY INSTRUCTIONS. HEIGHT ADJUSTMENT FROM /2 TO 2-¼ & SLOPE ADJUSTMENT FROM 0% TO 5% ROTATE PRODUCT CHARACTERISTICS: EACH CAP WILL COMPENSATE FOR UP TO /8 PER FOOT SLOPE (%) & ADD 3/8 TO THE OVERALL HEIGHT OF A PEDESTAL. PVC PIPE SHOULD NOT BE USED. ROTATE ONE CAP RELATIVE TO ANOTHER BY ALIGNING THE ALPHABETS TO CHANGE SLOPE. A & A WILL REACH MAXIMUM SLOPE AND A & E WILL CANCEL SLOPE. A MAXIMUM OF 5 CAPS CAN BE STACKED WITH TOTAL SLOPE OF 5/8 PER FOOT (5%) & WITH TOTAL HEIGHT OF 2-¼ INCLUDING THE USE OF BUFFER PADS. STACK CONFIGURATION CHART: CAP = 5/8 HIGH /8 PER FOOT % MAX 2 CAPS = HIGH /4 PER FOOT 2% MAX (A+A) 3 CAPS = -3/8 HIGH 3/8 PER FOOT 3% MAX (A+A+A) 4 CAPS = -7/8 HIGH /2 PER FOOT 4% MAX (A+A+A+A) 5 CAPS = 2-/4 HIGH 5/8 PER FOOT 5% MAX (A+A+A+A+A) PVC + 2 CAPS = VARIABLE HEIGHT 0% MAX PVC + 3 CAPS = VARIABLE HEIGHT % MAX PVC + 4 CAPS = VARIABLE HEIGHT 2% MAX PVC + 5 CAPS = VARIABLE HEIGHT 3% MAX COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 4

STAK-CAP PEDESTAL INSTRUCTIONS INSTALLATION INSTRUCTIONS - /2 to 2-¼ HIGH & 0%-5% SLOPE ROTATE Notch STACK. Chalk grid lines starting from door threshold based on paver size plus /8 gap. 2. Position Buffer Pads on chalk grid lines using the v-notch as a reference point. 3. Using a laser determine final height of pedestals from ½ to 2-¼ high. Consider in calculation the Buffer Pads as /8 thick. Spacer Tabs Laser line Notch Chalk line 4. Assemble by rotating & aligning alphabets of one Stak-Cap with the Stak-Cap bellow it for slope compensation. 5. Complete assembly by snapping on Spacer Tabs in order to provide proper spacing of pavers. Spacer tabs are perforated and can be ripped or cut off. 6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Orient the pedestal assembly so that the top Stak-Cap pair high side points towards decline of slope. Final project grade Level Level Leveling Shims Laser line Deck 7. Adjust final pedestal height by using Uni-Shims whole or in segments at the top of pedestal assembly. 8. Use a spirit level to check level and use additional half or quarter Uni-Shims for fine tuning of individual corners of pavers. 9. For IPE wood insert the lock washer in to the kurf-cut on the corners of wood tiles then insert screw through lock washer and hand tighten. 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.tiletechpavers.com COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 5

UNI-JUST PEDESTAL SYSTEM COMPONENT ASSEMBLY INSTRUCTIONS. HEIGHT ADJUSTMENT FROM 2-/4 TO 24 & SLOPE ADJUSTMENT FROM 0% TO 4% SPACER TABS - /8 TABS CAN BE BROKEN OFF ALLOW DIFFERENT PAVING CONFIGURATION UNI-CAP SELF-LEVELING & ADJUSTABLE IN ANY DIRECTION FROM 0% TO 4% SLOPE UNI-INSERT - 3/4 & -/2 SCREW ADJUSTMENT FROM 3/4 TO -/2 OF ADDITIONAL HEIGHT UNI-COLLAR SNAPS ON TO END OF 4 ø SDR35 PVC PIPE 4 ø SDR35 PVC PIPE USER SUPPLIED & CUT TO REQUIRED HEIGHT UNI-BASE SNAPS ON TO END OF 4 ø SDR35 PVC PIPE OR CAN BE USED WITH UNI-INSERT BUFFER PAD USED UNDER BASE TO PROVIDE SLIP RESISTANCE, NOISE DAMPENING & MEMBRANE PROTECTION PRODUCT CHARACTERISTICS: ADJUSTABLE HEIGHT FROM 2-/4 TO 24 WITH USE OF 4 ø SDR35 PVC PIPE. SELF-LEVELING CAP AUTOMATICALLY ADJUST SLOPE FROM 0% TO 4%. SCREW ADJUSTABLE WHILE PEDESTALS ARE LOADED FOR FINAL HEIGHT ADJUSTMENT OF -/2 RESISTANT & IMPERVIOUS TO FREEZE-THAW, WATER, MOLD, ACID & ULTRAVIOLET DETERIORATION. RESISTANT TO TEMPERATURES BETWEEN -22 F AND +250 F. LARGE FOOT PRINT SPREADS WEIGHT OVER ROOFING MEMBRANE AND SUBSTRATE BUFFER PADS PROVIDE NOISE DAMPENING, SLIP RESISTANCE AND PROTECTION TO ROOFING MEMBRANE AND SUBSTRATE. MAXIMUM DESIGN CAPACITY OF 2,OOO LBS PER PEDESTAL. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 6

UNI-JUST PEDESTAL INSTRUCTIONS INSTALLATION INSTRUCTIONS /2 to 24 HIGH & 0%-4% SLOPE. Chalk grid lines starting from door threshold based on paver size plus /8 gap. 2. Using a laser determine final height of pedestals. Deduct ¼ for base & cap assembly. Measure & mark PVC pipe to be cut. 3. Cut PVC pipe to required height with a 2 chop saw. Using sand paper remove any burrs from cut ends. Laser line Notch Chalk line 4. Assemble by inserting cut PVC pipe in to Uni-Base and Uni-Collar in to other end of PVC pipe. Screw Uni-Insert in to Uni-Collar minimum of 2 threads. 5. Complete assemble by rotating & aligning Uni-Cap with Uni-Insert. Align & attach Buffer Pad to Uni-Base. 6. Position pedestal under laser line and align Buffer Pad notch with chalk line. Final project grade Final project grade Allen Key Laser line Level Laser line Deck Deck 7. Adjust final pedestal height by using Allen Key from top to screw up or down Uni-Insert. 8. Use a spirit level to level Uni-Cap in any direction. 9. Use Allen Key to fine tune loaded pedestal for a perfect level & height. 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.tiletechpavers.com COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 7

BASE SLOPE PLATE BASE SLOPE ADJUSTMENT FROM 0 TO (0-8%) PER FOOT SLOPE. STACK AND ROTATE ONE PLATE RELATIVE TO ANOTHER TO COMPENSATE FOR A RANGE OF SLOPES. POINT BOTH FINGER TABS DOWN HILL FOR MAXIMUM SLOPE COMPENSATION. 90 FINGER TABS BUFFER PAD FOR BASE LEVELING, BASE SLOPE PLATES (BSP) CAN BE STACKED UNDER UNI-BASE AND EACH PLATE COMPENSATES FOR /4 PER FOOT (2%) SLOPE AND ADDS 3/8 TO THE OVERALL HEIGHT OF PEDESTAL. A MAXIMUM OF FOUR PLATES MAY BE STACKED BELOW A PEDESTAL IN ORDER TO COMPENSATE FOR UP TO PER FOOT (0-8%) SLOPE. ALWAYS USE A BUFFER PAD UNDER COMPLETE PEDESTAL ASSEMBLY. BASE SLOPE PLATE APPLICATION - SECTION DETAILS UNI-JUST PEDESTALS 2 TO 22 HIGH 0% SLOPE 2% SLOPE x BASE PLATE 4% SLOPE 2 x BASE PLATE 6% SLOPE 3 x BASE PLATE 8% SLOPE 4 x BASE PLATE COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 8

UNI-SHIM APPLICATION /8 & /6 RIGID SHIMS USED ON TOP AND UNDER PEDESTAL UNI-SHIM /8 & /6 A UNI-SHIM /8 OR /6 MAY BE PLACED ON TOP OF EACH PEDESTAL. UNIQUE INTERLOCKING FEATURE ALLOWS SHIMS LOCK TO EACH OTHER AND TO PEDESTAL TOPS, NO GLUING REQUIRED. SHIMS MAY BE USED WHOLE OR BROKEN INTO SEGMENTS FOR FINE TUNING & LEVELING. MAY BE CUT INTO SEGMENTS UNI-SHIM TOP OF PEDESTAL UNI-SHIMS MAY BE PLACED ON TOP OF PEDESTALS FOR MINOR LEVELING OF PAVERS WITH THICKNESS VARIATIONS. USE NO MORE THAN 3 SHIMS STACKED PER CORNER. UNI-SHIM UNDER PEDESTAL PLACE UNI-SHIMS, WHOLE OR IN SEGMENTS, UNDER EACH PEDESTAL IN A STAIR STEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE NO MORE THAN 2 SHIMS, AND ADHERE THEM TO EACH OTHER WITH CONSTRUCTION ADHESIVE. ADHERE W/ POLYURE- THANE CONSTRUCTION ADHESIVE DO NOT ADHERE TO SUBSTRATE COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 9

STAK-CAP & UNI-JUST PEDESTALS SAMPLE PEDESTAL CONFIGURATION & COMBINATION COMPENSATION FROM /2 TO 36 HIGH & 0% TO 4% SLOPE SPACER FIXED HEIGHT /8 STAK-CAP HEIGHT 3/8 SLOPE % Max STAK-CAP X2 HEIGHT SLOPE 2% Max STAK-CAP X3 HEIGHT -3/8 SLOPE 3% Max STAK-CAP X4 HEIGHT -7/8 SLOPE 4% Max STAK-CAP X5 HEIGHT 2-¼ SLOPE 5% Max UNI-JUST w/o PVC PIPE HEIGHT 2-¼ TO 3 SLOPE 0% TO 4% UNI-JUST w/ PVC PIPE HEIGHT 3 TO 3-¾ SLOPE 0% TO 4% UNI-JUST w/ PVC PIPE HEIGHT VARIABLE MAX 36 SLOPE 0% TO 4% COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 0

SAMPLE DECK LAYOUT OVERVIEW OF PEDESTAL PLACEMENT SEE ENLARGED SECTION PLANS: A DOOR THRESHOLD PEDESTAL PLACEMENT E LOW THRESHOLD PEDESTAL PLACEMENT B RADIUS PERIMETER PEDESTAL PLACEMENT F ROOF DRAIN PEDESTAL PLACEMENT C CORNER PERIMETER PEDESTAL PLACEMENT D DIAGONAL PERIMETER PEDESTAL PLACEMENT HP E A D B F HP LP SLOPE /4 PER RD FOOT LP RD C LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page

2 SAMPLE INITIAL INSTALLATION USING T SHAPED PATTERN MAXIMUM /8 GAP AT PERIMETER HP REMOVE SPACER TABS FROM PERIMETER PEDESTALS AS NECESSARY START PAVER AND PEDESTAL INSTALLATION FROM HIGH POINT OR THRESHOLD USING WHOLE PAVER START PAVER AND PEDESTAL INSTALLATION IN T SHAPED PATTERN LP LP - LOW POINT HP - HIGH POINT RD - ROOF DRAIN DETERMINE CAVITY HEIGHT AT ALL THRESHOLDS, DRAINS AND HIGH POINTS. DEDUCT THE THICKNESS OF THE PAVERS FROM THE MEASURED DISTANCE BETWEEN THE TOP OF THE MEMBRANE AND THE TOP OF THE PAVERS TO DETERMINE THE PEDESTAL HEIGHT NEEDED FOR EACH LOCATION. USE A LASER LEVEL TO MARK THE TOP OF PEDESTAL ELEVATION AROUND THE DECK. PLAN PAVER & PEDESTAL LAYOUT PATTERN BEFORE STARTING, BY MARKING GUIDELINES ON THE ROOF IF NEEDED. USING THE GUIDELINES INSTALL A T SHAPED PORTION OF THE NEW DECK STARTING FROM THE THRESHOLD OR HIGH POINT. PAVERS ON BOTH ROWS OF THE T SHOULD BE ADJUSTED TO THE CORRECT HEIGHT AND LEVELED BEFORE PROCEEDING. INSTALLATION ON ALL SIDES OF THE T CAN THEN PROCEED AT THE SAME TIME. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 2

A THRESHOLD PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW SLOPE DIRECTION UNI-JUST PEDESTAL PERIMETER GAP /8 MAX SLOPE UNI-JUST PEDESTAL VALLEY LINE THRESHOLD PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTAL BOTTOM OF THRESHOLD TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING UNI-JUST PEDESTALS 2 TO 24 HIGH & 0%-4% SLOPE SLOPE TO DRAIN SDR35 PVC ROOF DECK THRESHOLD & PEDESTAL HEIGHT WILL VARIE INSULATION 60psi MIN SELF-LEVELING CAP 0% TO 4% SLOPE COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 3

B RADIUS PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW ADHERE EDGE CUT PAVER TO TOP OF PEDESTAL WITH SILICONE ADHESIVE UNI-JUST PEDESTAL REMOVE EXTRA TABS ON PERIMETER PEDESTAL TO SUPPORT PAVER EDGES SLOPE PERIMETER GAP /8 MAX RADIUS PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTAL RE-INSERT REMOVED TABS & ADHERE WITH SILICONE UNI-JUST PEDESTAL ADJUSTABLE /2 TO 24 HIGH TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING SLOPE TO DRAIN ADHERE EDGE CUT PAVERS TO PEDESTAL TOP WITH SILICONE ADHESIVE SELF-LEVELING CAP 0% TO 4% SLOPE ROOF DECK INSULATION 60psi MIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 4

C CORNER PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW UNI-JUST PEDESTAL ADHERE EDGE CUT PAVER TO TOP OF PEDESTAL WITH SILICONE ADHESIVE REMOVE EXTRA TABS ON PERIMETER PEDESTALS TO SUPPORT PAVER EDGES PERIMETER GAP /8 MAX CORNER PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX RE-INSERT REMOVED TABS & ADHERE WITH SILICONE REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTALS UNI-JUST PEDESTALS ADJUSTABLE /2 TO 24 HIGH TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING SLOPE TO DRAIN ADHERE EDGE CUT PAVERS TO PEDESTAL TOP WITH SILICONE ADHESIVE ROOF DECK SELF-LEVELING CAP 0% TO 4% SLOPE INSULATION 60psi MIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 5

D DIAGONAL PERIMETER APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW UNI-JUST PEDESTAL ADHERE EDGE CUT PAVER TO TOP OF PEDESTAL WITH SILICONE ADHESIVE REMOVE EXTRA TABS ON PERIMETER PEDESTALS TO SUPPORT PAVER EDGES SLOPE PERIMETER GAP /8 MAX DIAGONAL PEDESTAL APPLICATION - SECTION DETAILS PERIMETER GAP /8 MAX REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTALS RE-INSERT REMOVED TABS & ADHERE WITH SILICONE UNI-JUST PEDESTALS ADJUSTABLE /2 TO 24 HIGH TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING SLOPE TO DRAIN ADHERE EDGE CUT PAVERS TO PEDESTAL TOP WITH SILICONE ADHESIVE SELF-LEVELING CAP 0% TO 4% SLOPE ROOF DECK INSULATION 60psi MIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 6

E LOW HEIGHT PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW STACK & ROTATE PEDESTAL CAPS TO ADD HEIGHT AND CHANGE SLOPE USE UNI-SHIM FOR FINE TUNING OF INDIVIDUAL PAVERS HP STAK-CAP PEDESTAL SPACER TABS /8 SLOPE PERIMETER GAP /8 MAX STACKABLE CAPS (5 MAX) /2 TO 2-/4 HIGH 0% TO 5% SLOPE B REMOVE EXTRA TABS ON PERIMETER PEDESTALS TO SUPPORT PAVER EDGES B LOW HEIGHT PEDESTAL APPLICATION - SECTION DETAILS REMOVE EXTRA SPACER TAB ON PERIMETER PEDESTALS RE-INSERT REMOVED TABS & ADHERE WITH SILICONE STAK-CAP (5 MAX) /2 TO 2-/4 HIGH 0% TO 5% SLOPE TOP OF PAVER DECK TOP OF PEDESTAL TOP OF WATERPROOFING PERIMETER GAP /8 MAX ROOF DECK SLOPE TO DRAIN USE UNI-SHIM ON TOP OR UNDER PEDESTAL FOR FINE HEIGHT & SLOPE ADJ. INSULATION 60psi MIN 4. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.tiletechpavers.com COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 7

F DRAIN PEDESTAL APPLICATION ENLARGED PLAN VIEW & SECTION DETAILS ENLARGED PLAN VIEW UNI-JUST PEDESTALS ADJUSTABLE HEIGHT 2-/4 TO 24 0% TO 4% SLOPE A STAK-CAPS PEDESTALS /2 TO 2-/4 HIGH 0% TO 5% SLOPE 5 UNITS MAX ROOF DRAINS OVER DRAIN PAVERS OR STEEL PLATE (/4 MIN) USE ADDITIONAL PEDESTAL A DRAIN PEDESTAL APPLICATION - SECTION DETAILS OVER DRAIN PAVERS OR STEEL PLATE (/4 MIN) USE ADDITIONAL PEDESTAL CLAULKING ROOF WALL JUNCTURE USE UNI-SHIMS ON TOP OR UNDER PEDESTAL FOR FINE HEIGHT & SLOPE ADJ. STAK-CAPS PEDESTALS /2 TO 2-/4 HIGH UNI-JUST PEDESTALS 2-/4 TO 24 HIGH METAL COUNTERFLASHING WATERPROOF MEMBRANE SLOPE TO DRAIN SLOPE TO DRAIN ROOF DECK 60psi MIN INSULATION ROOF DRAIN COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 8

PERIMETER EDGE RESTRAINT OPTIONS METAL FLASHING AND WOOD FASCIA CONTAINMENT DETAILS METAL FLASHING CONTAINMENT TWO PIECE EDGE METAL LEDGER BOARD DECK SCREWS PRE-FINISH METAL 22GA. GALV. METAL FLASHING MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA- PET. BOTTOM OF METAL FLASHING CAN BE BENT OR CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN. ROOF DECK WOOD FASCIA CONTAINMENT FASCIA BOARD FLUSH WITH TOP OF PAVER LEDGER BOARD DECK SCREWS FASCIA BOARD MUST FULLY CONTAIN PAVER AND TIE BACK INTO BUILDING WALL OR PARA- PET. BOTTOM OF FASCIA BOARD CAN BE CUT ABOVE SUBSTRATE TO ALLOW WATER TO DRAIN. ROOF DECK COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 9

PERIMETER EDGE RESTRAINT OPTIONS STEP-DOWN AND GREEN ROOF CONTAINMENT DETAILS STEP-DOWN CONTAINMENT FASCIA BOARD FLUSH WITH TOP OF PAVER VARIABLE RISER HEIGHT (PER CODE) LEDGER BOARD UNI-JUST PEDESTALS 2-/4 TO 24 HIGH ROOF DECK LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS. GREEN ROOF CONTAINMENT ENGINEERED GREEN ROOF SOIL ROOF DECK FILTER FABRIC L-CHANNEL WITH DRAIN HOLES COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 20

2 STEP-DOWN PEDESTAL APPLICATION STEP-DOWN PEDESTAL APPLICATION SECTION DETAILS LEDGER BOARD IS FASTENED TO VERTICAL PVC PIPE OF PEDESTAL WITH DECK SCREWS. THE FASCIA BOARD IS FASTENED TO THE LEDGER BOARD WITH FINISH SCREWS AND FUNCTIONS AS CONTAINMENT TO PREVENT LATERAL MOVEMENT OF PAVERS. FASCIA BOARD FLUSH WITH TOP OF PAVERS LEDGER BOARD VARIABLE RISER HEIGHT (PER CODE) UNI-JUST PEDESTALS 2-/4 TO 24 HIGH ROOF DECK COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 2

WOOD TILE & PEDESTAL APPLICATION TRANSITION, ALIGNMENT & LOCK DOWN DETAILS DECK SCREW -/4 LONG LOCK WASHER INSERT THE LOCK WASHER IN TO THE KURF CUT BETWEEN THE UPPER SLAT AND BOTTOM RAIL OF 3 WOOD PAVERS. INSERT THE 4th PAVER IN TO THE 4TH CORNER. ONCE ALL 4 PAVERS ARE TIGHTLY IN PLACE INSERT DECK SCREW (-/4 LONG) THROUGH LOCK WASHER AND HAND TIGHTEN IN TO PEDESTAL TOP UNTIL ALL 4 PAVERS ARE SECURELY FASTENED TO THE PEDES- TAL. DO NOT OVER TIGHTEN. UNI-JUST PEDESTAL IPE WOOD & PAVER TRANSITION AND ALLIGNMENT UNI-SHIM USED FOR INDIVIDUAL WOOD / PAVER ALIGNMENT TILE TECH IPE WOOD COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 22

IPE WOOD TILES DETAILS 20 x 20 x -/2 Toll Free: 888-380-5575 Fax: 23-380-556 CROSS MEMBER TOP VIEW 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.tiletechpavers.com COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 23

IPE WOOD TILES DETAILS 24 x 24 x -5/8 CROSS MEMBER TOP VIEW 3. CONTRACTOR S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.tiletechpavers.com COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 24

JOIST DECK & PEDESTAL APPLICATION JOIST DECK INSTALLATION DETAILS & SPANNING CHART JOIST HANGER UNI-SHIM JOIST SPAN JOIST PLATE DECK PLANKS JOIST JOIST HANGER JOIST SPACING PEDESTAL SPACING BEAM SIZE -4x OR 2-2x 2" O.C. JOIST SPACING UNI-JUST PEDESTAL WITH JOIST CAP JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING 2x6 0' - 0" 4x6 OR (2) 2x6 24" O.C. 2x8 2x0 3' - 2" 6' - 0" 4x8 OR (2) 2x8 4X0 OR (2) 2x0 24" O.C. 24" O.C. 6" O.C. JOIST SPACING JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING 2x6 9' - " 4x6 OR (2) 2x6 24" O.C. NOTE: THIS DIAGRAM AND CHART ARE FOR CONVENIENCE ONLY. COMPATIBILITY OF DECKING MATERIAL AND JOIST SPANNING WILL VARY DEPENDING ON THE TYPE / SIZE OF CONCRETE PAVERS, WOOD OR COMPOSITE MATERIALS BEING USED. ADDITIONALLY CODE REQUIREMENTS VARY PER LOCATION AND IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE DECK MEETS CODE REQUIREMENTS. 2x8 2' - 0" 4x8 OR (2) 2x8 24" O.C. 2x0 5' - 2" 4X0 OR (2) 2x0 24" O.C. 20" O.C. JOIST SPACING JOIST SIZE JOIST SPAN BEAM SIZE PEDESTAL SPACING 2x6 7' - " 4x6 OR (2) 2x6 24" O.C. 2x8 0' - 2" 4x8 OR (2) 2x8 24" O.C. 2x0 2' - 5" 4X0 OR (2) 2x0 24" O.C. COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 25

WIND-LOC PAVER & PEDESTAL APPLICATION PAVER LOCK DOWN SYSTEM DETAILS. PLAN AND PROFILE VIEW Toll Free: 888-380-5575 Fax: 23-380-556 WIND-LOC SCREW WIND-LOC PLATE WIND-LOC BASE WIND-LOC PEDESTAL IS MADE OF HIGH IMPACT POLYPRO- PYLENE & ABS AND IS MADE TO LOCK THE PAVER SYSTEM TOGETHER AND PREVENT WIND UPLIFT. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON GRID LINES. SET THE WIND-LOC BASE ON TOP OF THE PEDESTAL SYSTEM AND SET WIND-LOC PAVERS ON TO WIND-LOC BASE. BE SURE TO ALIGN RECESS ON BACK SIDE OF PAVER WITH THE DOMES ON THE WIND-LOC BASE. POSITION & ALIGN WIND-LOC PLATE ON TO WIND-LOC PAVERS IN A DIAMOND CONFIGU- RATION. INSTALL WIND-LOC SCREW IN TO WIND-LOC BASE WITH A HEX BIT. TIGHTEN DOWN TO 80 PSI. DO NOT OVER TIGHTEN. WIND-LOC PAVERS Pat. # 8,453,39 & Pat. Pen WIND-LOC - PROFILE VIEW WIND-LOC SCREW WIND-LOC BASE WIND-LOC PLATE Patent Pending WIND-LOC PAVERS UNI-JUST PEDESTAL COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 26

HEX-TRAY SNOW MELT SYSTEM Tile Tech Inc. PAVER SNOW MELT SYSTEM DETAILS. PLAN AND PROFILE VIEW National Distribution Toll Free: 888-380-5575 Tel: 23-380-5560 Fax: 23-380-556 TILE TECH PORCELAIN HEAT TRANSFER PLATE PEX TUBING CHANNELS HEX-TRAY FOAM INSULATION HEX-TRAY SNOW MELT SYSTEM COMPONENTS INCLUDES A HONEYCOMB STRUCTURAL TRAY WITH PEX TUBING CHANNELS, A FOAM INSULATION PANEL, ALUMINUM HEAT TRANSFER PLATE AND USER SUPPLIED ½ PEX TUBING. PRE ASSEMBLE THE FOAM INSULATION PANEL TO THE BACK OR BOTTOM SIDE OF THE HEXTRAY AND SECURE WITH SUPPLIED CORK-SCREW. POSITION AND LEVEL HYBRID PEDESTAL SYSTEM ON TO GRID LINES. PLACE SEMI ASSEMBLED HEX-TRAY ON TO PEDESTAL SYSTEM. LEVEL & SECURE FOUR ADJACENT CORNERS TO PEDESTAL SYSTEM USING HEX-LOCK DISK AND SECURE WITH DECK SCREW (-/4 LONG). POSITION AND ALIGN HEAT TRANSFER PLATE TO TOP OF HEXTRAY. AT TERMINATION POINTS AND WALLS, CUT BACK HEAT TRANSFER PLATE TO EXPOSE THE U SHAPED CHANNELS IN ORDER TO LOOP BACK PEX TUBING. INSTALL PEX TUBING AND TEST FOR LEAKS. INSTALL PORCELAIN PAVERS. Hex-Tray Snow Melt System PEX TUBING CHANNELS HYBRID PEDESTAL SYSTEM Pat. # 8,850,753 & Pat. Pen Patent Pending HEX-TRAY SNOW MELT - PROFILE VIEW TILE TECH PORCELAIN PAVERS PEX TUBING HEAT TRANSFER PLATE HEX-TRAY FOAM INSULATION COPYRIGHT 205 TILE TECH INC., ALL RIGHTS RESERVED. Page 27

Tile Tech Pedestal 888-380-5575 23-380-556 Sales@tiletechpavers.com www.tiletechpavers.com HP-D 0/5 205 Tile Tech Inc Visit our website at www.tiletechpavers.com for complete design details and photo gallery MADE IN AMERICA