Code Compliance Research Report CCRR-0225

Similar documents
Code Compliance Research Report CCRR-0225

Code Compliance Research Report CCRR-0257

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR 0277

Code Compliance Research Report CCRR-0118

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0262

Code Compliance Research Report CCRR-0187

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0223

Code Compliance Research Report CCRR-0208

Code Compliance Research Report CCRR-0171

Code Compliance Research Report CCRR-0106

Code Compliance Research Report CCRR-0234

Code Compliance Research Report CCRR-0137

Code Compliance Research Report CCRR 0232

Code Compliance Research Report CCRR-0164

Code Compliance Research Report CCRR 0241

Code Compliance Research Report CCRR-0114

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0185

Code Compliance Research Report CCRR-0153

Code Compliance Research Report CCRR-0186

Code Compliance Research Report CCRR 0270

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125

Code Compliance Research Report CCRR-0266

Code Compliance Research Report CCRR-0205

Code Compliance Research Report CCRR-0176

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0101

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

WESTERN SPINDLE LLC TEST REPORT

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

ATI Evaluation Service A Division of Architectural Testing Certification Services

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

ATI Evaluation Service A Division of Architectural Testing Certification Services

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

ATI Evaluation Service A Division of Architectural Testing Certification Services

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0100

ATI Evaluation Service A Division of Architectural Testing Certification Services

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

SECTION COLD-FORMED METAL TRUSSES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

Advantage ICF System Product Information Bulletin

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0131

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

ATI Evaluation Service A Division of Architectural Testing Certification Services

The Perfect Block OEM ICC Equivalent Product Compliance Report

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI-ES Code Compliance Research Report

ATI Evaluation Service A Division of Architectural Testing Certification Services

CITY OF LOS ANGELES CALIFORNIA

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

ATI-ES Code Compliance Research Report

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

ATI Evaluation Service A Division of Architectural Testing Certification Services

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: SRL INDUSTRIES LTD.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-40

HAWORTH TECCRETE WITH PORCELAIN FLOOR COVERING - CSI Specifications 04/25/2017

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Transcription:

Code Compliance Research Report CCRR-0225 Issue Date: 02-04-2016 Revision Date: 05-30-2018 Renewal Date: 02-10-2019 DIVISION: 09 00 00 - FINISHES Section: 09 69 00 Access Flooring REPORT HOLDER: Global Integrated Flooring Solutions Inc. 3700 32 nd Street Southeast Grand Rapids MI, 49512 www.globalifs.com REPORT SUBJECT: TecCrete Access Flooring System 1.0 SCOPE OF EVALUATION 1.1 This Research Report addresses compliance with the following Codes: 2015 and 2012 International Building Code (IBC) 2015 and 2012 International Residential Code (IRC) Evaluated in accordance with ICC-ES AC300 Acceptance Criteria for Access Floors revised March 2014. 1.2 The TecCrete Access Flooring System has been evaluated for the following properties (see Table 1): Structural Performance Fire Resistance 1.3 The TecCrete Access Flooring System has been evaluated for the following uses (see Table 1): TecCrete Access Flooring System provides a raised floor surface that enables the area below the raised floor to be utilized for the distribution of building utilities such as communication and data wiring, HVAC and other similar utilities. The access floor systems recognized in this report are not for use in residential occupancies (IBC Groups R-1, R-2, R-3 and R-4). 2.0 STATEMENT OF COMPLIANCE The TecCrete Access Flooring System complies with the Codes listed in Section 1.1, for the properties stated in Section 1.2 and uses stated in Section 1.3, when installed as described in this report, including the Conditions of Use stated in Section 6. 3.0 DESCRIPTION 3.1 Panels: The TecCrete Access Flooring System panels consist of 24 x 24 galvanized steel panels filled with a polished lightweight high-strength concrete that can be left exposed or covered with other floor finishes. See Figures 1, 2, and 3 for panel types and details. 3.2 Pedestals: The floor support pedestals consist of a square steel base plate of various dimensions welded to square or round vertical pedestal posts. The heights of the pedestals range from 1-1/2" to 60". See Table 3 and Figures 4-13 for pedestal details. The pedestals may be either anchored mechanically or with approved adhesives to clean solid structural concrete surfaces. 3.3 Connections: 3.3.1 The TecCrete panel is fastened directly to the pedestal head for the TecCrete Cornerlock systems. See Figure 1 and 2. The connection is made via 1/4" 20 TPI flat head Phillip-drive, carbon steel screw with a case hardness HRC 45. See Figure 12. 3.3.2 For the gravity-held TecCrete Non-CornerLock Panel system, the TecCrete panel rests directly on stringers without fastening. See Figure 3. 3.4 Stringers: The stringers can consist of either the Standard or Heavy Duty models. The Standard stringers consist of Grade 55 steel in thicknesses of 0.040 to 0.044 and lengths of 23 or 47 inches. The Heavy Duty stringers consist of 0.058 0.064 High Strength Low Alloy Improved Formability, HSLA-F Grade 50, galvanized G60 steel members. Both types of stringers include felt padding on the top surface of the stringer for noise reduction and proper seating of the floor panels.

Code Compliance Research Report CCRR-0225 Page 2 of 14 3.5 Pedestal Adhesives: Pedestal adhesives are listed in Table 4. See Table 3 for allowable lateral loads. 4.0 PERFORMANCE CHARACTERISTICS 4.1 TecCrete Access Flooring System complies with the uniform and concentrated loads specified in IBC Table 1607.1 for access floor systems for office and computer use. 4.2 The TecCrete Access Flooring System utilizing the Bare Panel was tested and found to be non-combustible in accordance with 2012 and 2015 IBC, Section 703.5.1. 5.0 INSTALLATION 5.1 General: The TecCrete Access Flooring System must be installed in accordance with the manufacturer s published installation instructions, the applicable Code, and this Research Report. A copy of the manufacturer s instructions must be available on the jobsite during installation. 5.2 The stringer layouts can use 24 inch or 48 inch stringers to provide a 24 x24 grid. See Figure 16. 5.3 The various types of supporting floor substrate material surfaces must be prepared per the manufacturer's installation instructions and the appropriate method of pedestal connection used. 5.4 The adhesion of the pedestal bases to sealed concrete surface is outside the scope of this report. Contact the manufacturer regarding the use of concrete sealants and their effect on the adhesives listed in this report. 5.5 Seismic design of lateral bracing for the access flooring system is beyond the scope of this report and must be designed by a Licensed Design Professional in the jurisdiction where the project is located to meet the specific lateral loads of each project. 6.0 CONDITIONS OF USE 6.1 Installation must comply with this Research Report, the manufacturer s published installation instructions, and the applicable Code. In the event of a conflict, this report governs. 6.2 The raised access floor system may be mechanically attached to concrete and/or steel with approved anchors. Anchors must satisfy the design load requirements specified in Chapter 16 of the Building Code and must meet the following minimum requirements. 6.2.1 A minimum of four anchors must be used in the four pre-drilled holes in the pedestal base plate. 6.2.2 The anchors must be stainless steel, galvanized steel, or other approved material compatible with the pedestal base plate. 6.2.3 The anchors must have a minimum diameter of 3/8 inch. 6.3 Where required by the building official, engineering calculations and details shall be provided. The calculations shall verify that the anchorage complies with the Building Code for the type and condition of the supporting construction. 6.4 The access floor must be supported directly on a concrete floor of fire-resistive construction. 6.5 All designs and calculations shall be prepared by a licensed design professional according to the requirements in the jurisdiction where the project is located. 6.6 The raised floor system is not evaluated for equipment anchored to the access floor system. 6.7 Floor finishes shall comply with IBC Section 804. 6.8 The TecCrete Access Flooring System is manufactured under a quality control program with inspections by Intertek Testing Services NA, Inc. 7.0 SUPPORTING EVIDENCE 7.1 Reports of tests in accordance with AC300 Acceptance Criteria for Access Floors revised March 2014. 7.2 The panels were tested per ASTM E 2322-03 Standard Test Method for Conducting Transverse and Concentrated Load Tests on Panels used in Floor and Roof Construction to determine the maximum deflection and permanent set of the access floor system under uniform loading.

Code Compliance Research Report CCRR-0225 Page 3 of 14 7.3 The non-combustible fire test was in accordance with ASTM E 136-04 - Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C. ASTM E136-12 reviewed and deemed equivalent to ASTM E136-04. 7.4 Reports of testing on pedestal adhesives per AC05 Acceptance Criteria for Sandwich Panel Adhesives in accordance with AC300 Section 4.4. 7.5 Documentation of an Intertek approved quality control system for the manufacturing of products recognized in this report. 8.0 IDENTIFICATION The TecCrete Access Flooring System is identified with the manufacturer s name (Global IFS), address and telephone number, the product name (TecCrete Access Flooring System), the statement See CCRR-0225 at https://bpdirectory.intertek.com for uses and performance levels., the Intertek Mark as shown below, and the Code Compliance Research Report number (CCRR-0225). 9.0 OTHER CODES This section is not applicable. 10.0 CODE COMPLIANCE RESEARCH REPORT USE 10.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 10.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 10.3 Reference to the https://bpdirectory.intertek.com is recommended to ascertain the current version and status of this report. This Code Compliance Research Report ( Report ) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.

Code Compliance Research Report CCRR-0225 Page 4 of 14 TABLE 1 TECCRETE ACCESS FLOOR SYSTEM CODE CLASSIFICATION Model Panel Thickness (inches) Stringers Code Occupancy Classification 1250 1-1/8 None (See Fig. 1) 1500 1-1/8 Standard (See Fig. 2 & 3) 1500SL 1-1/2 None (See Fig. 1) 2000 1-1/2 Standard (See Fig. 2 & 3) 2500 1-1/2 HD (See Fig. 2 & 3) IBC - ALL USE GROUPS TABLE 2 PROPERTIES EVALUATED PROPERTY IBC SECTION Structural Loading Table 1607.1 Fire Resistance 703.5.1 TABLE 3 PEDESTAL TYPES AND ALLOWABLE LATERAL LOADS Model Ultra- Low Max Pedestal Height (inches) 1.5 Low 4.7 0 27 1 60 3 60 4 5 60 60 Pedestal Mechanical Anchors (4) 3/8 16 Bolts w/ 1" OD washer (4) 3/8 16 Bolts w/ 1" OD washer (4) 3/8 16 Bolts w/ 1" OD washer (4) 3/8 16 Bolts w/ 1" OD washer (4) 3/8 16 Bolts w/ 1" OD washer (4) 3/8 16 Bolts w/ 1.5" OD washer (4) 3/8 16 Bolts w/ 1.5" OD washer Allow Lateral Load @ Max Height (Mechanical Attachment) (in-lbs) (SF=3) Allow Lateral Load @ Max Height (Envirotec 105 Adhesive) (in-lbs) (SF=5) Allow Lateral Load @ Max Height (Seal Bond 95 Adhesive) (in-lbs) (SF=5) 418 207 160 440 248 315 396 328 262 975 583 566 1434 593 853 2314 1272 1345 2236 1597 1294

Code Compliance Research Report CCRR-0225 Page 5 of 14 TABLE 4 ADHESIVES Adhesive Type NAME Standard Envirotec 105 AC05 Type I, Class1 Seal Bond 95 AC05 Type I, Class1 FIGURE 1 - CORNERLOCK INSTALLATION. NO STRINGERS MODELS 1250 AND 1500SL (Shown with optional air seal between panels. Not evaluated for Air Plenum use)

Code Compliance Research Report CCRR-0225 Page 6 of 14 FIGURE 2 CORNERLOCK INSTALLATION WITH HD STRINGERS MODEL 1500, 2000 OR 2500

Code Compliance Research Report CCRR-0225 Page 7 of 14 FIGURE 3 NON-CORNERLOCK INSTALLATION WITH STANDARD STRINGERS MODELS 1500, 2000 OR 2500

Code Compliance Research Report CCRR-0225 Page 8 of 14 FIGURE 4 ULTRA-LOW PEDESTAL FIGURE 5 LOW PEDESTAL FIGURE 6 TYPE 0 PEDESTAL FIGURE 7 TYPE 1 PEDESTAL

Code Compliance Research Report CCRR-0225 Page 9 of 14 FIGURE 8 TYPE 3 PEDESTAL FIGURE 9 TYPE 4 PEDESTAL FIGURE 10 TYPE 5 PEDESTAL

Code Compliance Research Report CCRR-0225 Page 10 of 14 FIGURE 11 HEAD PLATE, ADJUSTABLE CONNECTION STUD, PEDESTAL AND BASE PLATE

Code Compliance Research Report CCRR-0225 Page 11 of 14 FIGURE 12 TYPICAL PEDESTAL / PANEL CROSS-SECTION WITHOUT STRINGERS FIGURE 13 PEDESTAL WITH STRINGER AND CONNECTIONS

Code Compliance Research Report CCRR-0225 Page 12 of 14 FIGURE 14 STANDARD STRINGER PROFILE AND DIMENSIONS

Code Compliance Research Report CCRR-0225 Page 13 of 14 FIGURE 15 HEAVY DUTY STRINGER PROFILE AND DIMENSIONS

Code Compliance Research Report CCRR-0225 Page 14 of 14 FIGURE 16 2' AND 4' STRINGER LAYOUT CONFIGURATIONS