VELUX INTEGRA VCM/VCE VELUX INTEGRA Solar VCS

Similar documents
RAPiD Safe Setup and Operation

The skylight has a specific top and bottom and can not be rotated.

itemp Anywhere Wireless Sensors and Cellular Gateway User s Guide

MOSQUITO HD VIDEO DRONE WITH LED LIGHTS. Item No User Manual

TallSlateTM Grandee Installation Manual

VIDEO CAMERA DRONE WITH LED LIGHTS

Product Guide PG A A3 ALPHA Meter/Node (ILC2)

AVerMedia AVerDVR POS Capture Box Quick Guide

Operation and Maintenance Manual

ALLMET CONTINENTAL INSTALLATION GUIDE

4-UP QUICK START GUIDE SAVE THIS GUIDE FOR FUTURE USE.

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

Pacific Tile Counter Batten and Batten

Pacific Tile Counter Batten and Batten

RAPiD VEHICLE SAFE. Owner s Manual. Instructional videos for Hornady Security products are available at hornady.com. With patented RFID technology.

Classic and NB Tile Counter Batten and Batten

USER MANUAL FOR MORE INFORMATION

INSTALLATION GUIDE.

MERGE-8. 8 into 2 MIDI Merge Box. Operating manual

STEALTH ROOFLIGHTS. Product. Scope. Appraisal No. 987 [2018] Appraisal No. 987 (2018) BRANZ Appraisals

Xerox Wide Format Stacker HS

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

SECTION BASIC ELECTRICAL REQUIREMENTS

Age User s Guide. Dominator Drone

Proud of its Heritage, Preparing for its Future

MA SERIES Owner's Manual

Metal Roofing. The Devil is in the Details SSRLU3B. I LU/HSW Hour

Infrared Digital Scouting Camera

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

NANO Q4 CAM PLUS NO. H002

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM UNDER METAL ROOFING

Instruction Manual ODY-1012

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

A. Hazardous Areas: Hazardous areas as defined by the NEC as Class I, Division 1, Group D, or Class I, Division 2, Group D hazardous are as follows:

Conversion Station Model 812

SRP-AirOutshield ROOF Issued:

Instruction Manual ODY-1012

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

Sub-construction for Wall-mounted Longlight

U51. Operations Guide

BARREL VAULT Tile Counter Batten and Batten Installation Guide

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

SECTION GENERAL ELECTRICAL REQUIREMENTS PART 1- GENERAL

Operable / Fixed Skylight Milgard Aluminum Window

Bituminous Building Paper

Patio Covers Building Guides for Homeowners

DUST FREE ACTIVE Total Home Air Purification

Chapter 4 Test. Directions: Write the correct letter on the blank before each question.

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

User Manual ebee and ebee Ag Revision 13 / November 2014 Copyright sensefly Ltd

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

Power Distribution Module Replacement Instructions

INSTALLATION INSTRUCTIONS

Product information Top-operated centre-pivot polyurethane roof window GGU

SRP-AirOutshield UV Issued:

User Manual. Precision Balances XSR models

New Residential Building and Major Alterations / Additions

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Verea Spanish S Roof Tile Installation Guide

TABLE OF CONTENTS INTRODUCTION SAFETY & PRECAUTIONS DRONE DIAGRAM TRANSMITTER DIAGRAM INSTALLING THE TRANSMITTER BATTERY INSTALLING THE DRONE BATTERY

ADDENDA #5- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

BUILDING EXTERIOR SHELL TRAINING

ROOFING APPLICATION STANDARD (RAS) No. 109

A. Section includes busway and fittings including plug-in units.

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS

Installation. Basic Rack Power Distribution Units AP9560 AP9561

Sub-construction for Atrium Ridgelight

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

Bituminous Roofing Underlay & Valley Guard

W A R R A N T Y. mr.steam I Feel Good, Inc. I

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

How Molekule Works. After two decades of research and development, a fundamentally new approach to air purification has arrived to your home.

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

International Existing Building Code 2006

LOG COLLEGE MIDDLE SCHOOL

Product information Additional window element GIU

RAY-CORE Structural Insulated Roof and Wall Panels

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

SECTION SELF-ADHERING SHEET FLASHING

SECTION STRUCTURAL INSULATED PANELS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

Eradicating ice dams begins below the roof deck. by Maciek Rupar

RESIDENTIAL BUILDING PLAN REQUIREMENTS

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

Tindo Karra. Installation and Specifications Manual. Introduction

General Conditions for Roofing Warranties. Section 2 Specific conditions for material warranty - Roofing products Eligibility and duration

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

Pre-Delivery Instructions

FLEXITHERM Double layer with Graphite Core Insulation

Transcription:

VELUX INTEGRA VCM/VCE VELUX INTEGRA Solar VCS VCM/VCE VCS Curb Mounted Skylight Installation Instructions 15-90 0-60 VAS 454191-2017-03

ENGLISH: Quick start guide 日本語 : クイックスタートガイド Index Important installation requirements 2 VCS Turn on power before installation 2 VCE/VCS Important information/warnings 3 Clearance around installations 4 Outside curb dimensions 5 Roof framing 6-7 Light shaft application 7 Installing underlayment 8-10 Installing flashing 11 Mounting skylight 11 VCS - Electrical connection 12 VCE - Electrical connection 13-14 Important installation requirements Roof pitch VCM/VCE/VCS is designed for roof pitches 0-60 (0:12-21:12). Special consideration for applications below roof pitch 15 : Any condensation that forms on the glass due to high humidity may drip. Standing water and dirt left on the glass may over time cause smudging and corrosion of the glass. Neither of the two above stated occurrences are covered under the VELUX warranty. Flashing Flashing ECL is designed for roof pitches 10-60 (2:12-21:12). Flashing ECW is designed for roof pitches 14-60 (3:12-21:12). Vapor barrier Where a vapor barrier is part of the roof construction, this barrier must be extended and connected to the skylight curb. Importance of proper installation Satisfactory product performance depends on proper installation. Seller accepts no responsibility whatsoever for failure of an installer to install VELUX roof windows and skylights in accordance with these installation instructions. Although VELUX roof windows and skylights are designed and manufactured to the highest standards, severe climatic exposure as well as adverse indoor conditions (i.e. high humidity) may produce temperature conditions which exceed product performance standards. In these cases, special preventive measures may be necessary. Seller reserves the right to implement product changes for improvement without prior notification. Refer to instructions for accessory type in question or contact your VELUX sales company for further information. Seller assumes no obligation whatsoever for failure of an architect, installer or building owner to comply with all applicable laws, ordinances, building codes and safety requirements. VCS Turn on power before installation VELUX INTEGRA KLR 200 ESPAÑOL: Guía rápida FRANÇAIS : Guide de démarrage rapide Before mounting the skylight: Turn on power. Control: See enclosed Quick start guide. 2 VELUX

VCE/VCS Important information/warnings Read instructions carefully before installation and operation as incorrect installation can lead to severe injury. Please keep instructions for future reference and hand them over to any new user. Safety The skylight can be used by persons (aged 8 years and above) with sufficient experience and knowledge if they have been given instruction concerning its safe use and understand the hazards involved. Cleaning and user maintenance must not be made by unsupervised children. Children must not play with the skylight and its electrical products. The remote control should be kept out of reach of children. Do not allow children near an open skylight. Before operating, ensure that the skylight with electrical products can be operated without risk of damage to property or injury to people or animals. For personal safety, never have head, hand, arm or any other body part out of or through the opening of the skylight without first having switched off main power supply. If repair or adjustment work is needed, disconnect main power supply and ensure that it cannot be reconnected unintentionally. It is recommended to place a remote control in the room where the skylight and its electrical products have been installed. If the skylight is positioned within reach, the opening of the skylight operator must be adjusted to reduce the maximum size of the opening (see section Adjusting the maximum opening in the user manual for the control). Failure to make such adjustment can result in serious injury or death. Make sure that the insect screen is installed before putting the skylight into use. FCC ID: XSG863829 and IC ID: 8642A-863829: Remote control Certificate of Radio Equipment in Japan: No. 10215191/AA/00 FCC ID: XSG863765 and IC ID: 8642A-863765: Window operator (skylight operator). This device complies with part 15 of the FCC and RSS-210 of the IC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the device and receiver. Connect the device to an outlet on a circuit different from that to which the reciver is connected. Consult the dealer or an experienced radio/tv technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the device. FCC Radiation Exposure Statement: This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The term "IC:" before the device certification number signifies that the Industry Canada technical specifications were met. Function If the rain sensor gets wet, the skylight automatically closes. Disabling the rain sensor while the skylight is open implies a risk of rain water entering the building. If the rain sensor is activated, the skylight will close within approximately 30 seconds. If the skylight is activated with the remote control or another activation control, it will take up to one minute until the skylight is completely closed. Therefore, in case of sudden rain, water may enter the room before the skylight is closed. In case of snow and/or ice, the operation of the skylight may be blocked resulting in damage to the skylight. Product This product has been designed for use with genuine VELUX products. Connection to or use with other products may cause damage, malfunction or injury. Electrical products must be disposed of in conformity with all local codes, ordinances, rules and regulations for electronic waste and not with household waste. Used remote control batteries have to be disposed of in conformity with the relevant environmental regulations and ordinances. Expected battery lifetime of the remote control: Approx 1 year. The packaging can be disposed of with usual household waste. Radio frequency band: 2.4 GHz. Radio frequency range: 110 yards (100 m) free field. Depending on building construction, the indoor range is approx 30 ft (10 m). However, constructions with reinforced concrete, metal ceilings and plaster walls with steel members may reduce the range. Maintenance and service Disconnect main power supply before carrying out any maintenance, repair, adjustment or service work to the skylight or products connected to it (including battery backup KLB 100, if installed) and ensure that it cannot be reconnected unintentionally. Maintenance and installation must be carried out in consideration of Health and Safety at work requirements. There are no serviceable parts inside the skylight operator. Spare parts are available through your VELUX sales company. Please provide information from the data plate. If you have any technical questions, please contact your VELUX sales company, see telephone list or www.velux.com. io-homecontrol provides advanced and secure radio technology that is easy to install. io-homecontrol labelled products communicate with each other, improving comfort, security and energy savings. www.io-homecontrol.com VELUX 3

Clearance around installations 18"/450 mm 12" 300 mm 12" 300 mm 18"/450 mm 24"/600 mm 12" 300 mm 12" 300 mm 24"/600 mm Maintain illustrated clearances between skylight frame and critical areas such as valleys, ridges, slope changes and roof-to-wallintersections. 4 VELUX

Outside curb dimensions 1 H H H W W W Skylight size Outside curb dimensions Maximum flashing dimensions 2222 25½" x 25½" 648 mm x 648 mm 665 mm x 665 mm min 3½" min 90 mm 2234 25½" x 37½" 648 mm x 952 mm 665 mm x 970 mm 1½" (38 mm) 2246 25½" x 49½" 648 mm x 1257 mm 665 mm x 1275 mm 3030 33½" x 33½" 851 mm x 851 mm 870 mm x 870 mm 3046 33½" x 49½" 851 mm x 1257 mm 870 mm x 1275 mm 4646 49½" x 49½" 1257 mm x 1257 mm 1275 mm x 1275 mm Build curb according to measurements in the chart. Use lumber with an actual thickness of 1½" (38 mm) and a minimum height of 3½" (90 mm). Curb height and attachment should comply with building codes and regulations and be secure enough to transfer the skylight loads to the framing members. Note: Skylight VCM/VCE/VCS cannot be rotated. The skylight operator has to be installed at the bottom of skylight curb. VELUX 5

Roof framing For cyclonic or high wind area requirements, contact your VELUX sales company or visit the national VELUX websites for more and detailed information. 2 Remove batten. 3 W H Install framing members and support battens. 6 VELUX

4 Install curb and roof batten. Light shaft application 5 Roof rafter Drywall Framing Vapor barrier Insulation VELUX 7

Installing underlayment 6 7" 180 mm 3" 75 mm 6" 150 mm Skylight curbs should be completely wrapped in self-adhesive membrane to ensure waterproofing. To achieve this waterproofing, use VELUX roofing underlayment ZOZ 216 (9" wide). ZOZ 216 must be applied before installing the flashing. First cut back felt 3" (75 mm) at bottom and sides of skylight, and 7" (180 mm) at top of skylight. Note: In case of roof pitches below 15 and if snow accumulation on the roof is likely, waterproofing is achieved by installing a continuous self-adhesive waterproof membrane beneath the roofing material and flashing material. Waterproof membrane around the skylight curb must be properly integrated with waterproof membrane on roof decking. Skylight curbs with heights over 3½" (90 mm) may require additional ZOZ 216 material for proper installation. 3" 75 mm 6" 150 mm ½" 13 mm 8 VELUX

Installing underlayment 7 Wrap the curb with VELUX roofing underlayment ZOZ 216 and create watershedding laps over felt at bottom and sides of skylight 6, 7. Note: Observe the measurements stated in 6 and 7. 6" 150 mm 6" 150 mm 3" / 75 mm 6" 150 mm ½" 13 mm VELUX 9

Installing underlayment 8 Wrap the curb at top frame of skylight with VELUX roofing underlayment ZOZ 216 and create proper water-shedding lap. 6" 150 mm ½" 13 mm 9a 9b 2 1 To allow for proper drainage, interweave felt with additional standard roofing underlayment as shown in 9a for new construction applications. For retrofit applications, interweave felt with additional standard roofing underlayment as shown in 9b. 10 VELUX

ECW Installing flashing 10 For thin roofing materials, use flashing ECL. ECL is designed for roof pitches 10-60 (2:12-21:12). For profiled roofing materials, use flashing ECW. ECW is designed for roof pitches 14-60 (3:12-21:12). ECW ECW Mounting skylight 11 Center the skylight on top of the curb and secure with #8 1¾" (45 mm) pan head stainless steel screws provided. Screws will penetrate the curb by at least ¾" (19 mm). Apply downward pressure to the top of the skylight frame while securing the screws. VELUX 11

VCS - Electrical connection Connect wire as shown. Install solar panel as shown and secure the screws. If not done already, turn on power and refer to KLR 200 instructions for registration and operation of skylight. 12 VELUX

VCE - Electrical connection 9" / 225 mm Prepare the framing for electrical wire (applies to VCE only). All wiring must be done with factory attached power cable. Wiring of power cable must be done in accordance with the latest edition of the National Electrical Code (NFPA 70) and all local codes and ordinances. ¾" / 20 mm by ½" / 15 mm VELUX 13

VCE - Electrical connection A junction box or an outlet box (not provided with skylight) is required for permanent connection of the 20 ft (6 m) skylight power cable. AU/NZ: A single phase 240 V, 50 Hz, 40 W branch circuit (continuous electrical feed) is required. The branch circuit must be protected by a 15 A circuit breaker or time delay fuse. The junction or outlet box in which the skylight power cable is terminated must be accessible for inspection after installation is complete. A listed junction or outlet box and listed wire nuts must be used for the connection to the branch circuit. A Cable (supplied with skylight): 20 ft (6 m) B Junction or outlet box (not provided with skylight) B A 14 VELUX

VELUX 15

Home owner information Please complete and give to home owner. Date:... Product number (stamped on product exterior):... Quantity:... Flashing:... AU: NZ: Accessories installed: Model... Size... Variant code... Roofing material:... Installation contractor:... Dealer purchased from:... VELUX Australia Pty. Ltd 1300 859 856 VELUX New Zealand Ltd. 0800 650 445 www.velux.com VCM/VCE/VCS CURB MOUNTED SKYLIGHT INSTALLATION INSTRUCTIONS. 2017 VELUX GROUP VELUX, THE VELUX LOGO, VELUX INTEGRA, io-homecontrol, AND THE io-homecontrol LOGO ARE REGISTERED TRADEMARKS USED UNDER LICENCE BY THE VELUX GROUP