Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Similar documents
Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Specification for: All Aluminum Alloy (AAAC) Type AL3 Stranded conductor For distribution overhead lines

11-SDMS-01 REV. 03 ( )

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

P.V.C. INSULATED UNARMOURED COPPER CABLES

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

SPECIFICATION FOR LUGS WITH CONE CLAMP SLEEVE FOR ROUND COPPER BUSBAR

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

NPS/002/023 Technical Specification for 132kV Power Cables.

MATERIAL STANDARD FOR CABLES AND WIRES

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

SPECIFICATION FOR BIMETALLIC COMPRESSION CABLE LUGS

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

SPECIFICATION FOR STOCKBRIDGE TYPE VIBRATION DAMPERS FOR DISTRIBUTION AND TRANSMISSION OVERHEAD LINES

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 22 kv, SINGLE CORE, 95mm 2 COPPER

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY)

SPECIFICATION FOR FRLS POWER CABLES

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts

Technical Specification for Plastic-Insulated Low Voltage Cables

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

MGVCL/MM/ 3Cx240 mm 2 XLPE Cables/2077 TECHNICAL SPECIFICATION FOR 11 KV XLPE POWER CABLE (CROSS LINKED POLYTHELENE DRY GAS CURED) SECTION I

SPECIFICATION FOR ALL ALUMINIUM ALLOY STRANDED CONDUCTOR

TECHNICAL SPECIFICATION FOR CONDUCTORS

SECTION 07. TECHNICAL SPECIFICATIONS OF 11 KV XLPE CU CABLE (1x500 mm 2 )

THE KENYA POWER AND LIGHTING CO. LTD

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification.

Technical Specification for Insulated Low Voltage Single Core Copper Cable

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

Clark Public Utilities

Test Report No.: Page 2 of 35

SPECIFICATION FOR STAY INSULATORS (PORCELAIN)

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION The ELECTRICITY (PEDE) TENDER DOCUMENTS FOR

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4

project 36 MW 1.0 INTRODUCTION AND PROJECT INFORMATION

26/35kV Copper XLPE Insulation Electric Cable

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

NATIONAL ELECTRIC POWER COMPANY (NEPCO) TENDER NO.8/2013 FOR THE SUPPLY OF CONDUCTORS FOR DOUBLE AND QUADRUPLE CIRCUITS 132 kv OHTL's

6A-51 DV wire (C rank)

TECHNICAL SPECIFICATIONS OF LAYING OF UNDER GROUND POWER CABLE FOR TRANSMISSION LINE

SPECIFICATION FOR RUBBER INSULATING GLOVES FOR MEDIUM VOLTAGE CLASS 2, 3

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

Test Report No.: Page 2 of 34

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

12-SDMS-01 Rev.02 SPECIFICATIONS FOR

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S)

INTERNATIONAL STANDARD

Technical Specification for Substation 11kV and 22kV Single Core Underground Cable

3 MODIFICATIONS TO EXISTING STANDARDS

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES

NPS/001/007 Technical Specification for Overhead Line Conductors

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

COMPILED BY FUNCTIONAL RESP APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE TYPES... 3

INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED.

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

NPS/002/013 Technical Specification for Telephone and Pilot Cable Joints

SPECIFICATION FOR 11 & 33kV COMPOSITE INSULATORS Part 1: Pin Type

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

REFERENCE CP_TSSPEC_024 2 DATE: DECEMBER 2008 PAGE: 1 OF 11 SPECIFICATION FOR FITTINGS FOR USE WITH LV ABC TABLE OF CONTENTS

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

XLPE CABLE (11KV - Aluminium)

WIRES, CABLES AND CORDS

SPECIFICATION FOR DISC INSULATORS (Standard Type)

*** Supercedes: BECO E and COM , , & ***

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

TECHNICAL SPECIFICATION

SPECIFICATION FOR LOW VOLTAGE H.R.C. FUSE RAILS SIZES "00", "2", "3"

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

TECHNICAL SPECIFICATION FOR. FOUR CORE AND TWO CORE XLPE CABLES of Various SIZES 16mm 2, 10mm 2 & 6mm 2 INSULATED & XLPE SHEATHED ARMORED LT CABLES

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

Cables for Railway Signalling Applications General Requirements

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

THE KENYA POWER AND LIGHTING CO. LTD

Transcription:

Edition Nº: 7 Issued date: February, 2017 NPS 91 Specifications for THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-91 for Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage U0/U = 0.6/1.0 kv This specification supersedes specification No. NPS-91/7 Haifa - Israel JUNE, 2017

Page 1 of 17 Content 1 - General 2 - Documents to be supplied with the Bid 3 - Standards 4 - Technical Requirements 5 - Tests 6 - Marking 7 - Packing 8 - Quality Assurance 9 - Prototype Approval 10 - Questionnaire Annex A - Spec. No. S.RL 2702 (R&D Lab.) Annex "B"- Procurement Quality Requirements (Spec.. Q-APP-02) Annex "C"- Schedule up to prototype approval Annex "D" Statement of manufacturing experience Prepared by: A. Lavian (-signed) Approved by: Dr. N. Grinberg (-signed)

Page 2 of 17 1 General 1.1 Scope This specification applies to unarmored, sectorial, four core, aluminum conductor power cables with extruded solid cross-linked polyethylene insulation (XLPE) for rated voltage U 0 /U (Um) = 0.6/1 (1.2) kv (henceforth referred to as Cables ). 1.2 The IECo. cat. No. Table 1 Type of Cable NA2XY (sm) Conductor Cross Section (mm 2 ) The IEC Cat. No. 4 X 95 3966041 4 X 240 3966058 2 Documents to be supplied with the Bid The Proposer shall submit all the following documents** to the IECo. with the bid documents. 2.1 Complete and fill in Questionnaire signed by the manufacturer; 2.2 A complete Type Test Reports, according to Israeli standard IS 1516-1(IEC standard 60502 part 1), issued within the last 7 years preceding the date of the bid, for the proposed cable or for a similar* cable 2.3 Certificate issued by the Standards Institution of Israel (SII) or any agreed accredited institution, attesting that the Manufacturer meets the requirements of the Israeli Standard IS 1516-1 for LV power cables ( IEC standard 60502 part 1), or submission of declaration that the offered cables meets the requirements of the Official Israeli Standard SII 1516-1 for LV power cables ( IEC standard 60502 part 1) and a commitment that three (3) month after notification of award the bidder will submit approval issued by the Standards Institution of Israel (SII) or other certified laboratory the Israeli Standard IS 1516-1 for LV power cables. (see Appendix A) 2.4 Cross-section drawings including dimensions; 2.5 Approval of conformance with ISO 9001 requirements shall be in a form of a certificate issued by a Certification Body (CB) which is accredited by an Accreditation Body (AB). The

Page 3 of 17 certificate should bare the logo of the CB and of its AB and/or the logo of the IAF. The certificate shall be valid on the date set for submission of the proposal. The certificate shall be valid for the scope of activities requested in the request for proposal. 2.6 Document approving experience: the manufacturer actively produced and supplied at least 150 km of the proposed cable or similar* cable during a period of at least 3 years during the last 7 years preceding the date of the bid. If required, the manufacturer shall submit reference list indicating the quantities of the cables manufactured and sold during these years; * Similar cable: Same construction, same conductor cross-section or bigger, the conductor may be either copper or aluminum. ** All the above documents shall be in English. 3 Standards 3.1 Standards referenced in this specification and in supplement to this specification, form an integral part of this specification; 3.2 All the standards referred to the most current issue, including all amendments and supplements, as of the date of the bid; 3.3 The cables that are provided under this specification shall be designed, manufactured inspected, tested and preserved in compliance with the standards as specified herein; 3.4 In case of differences between the present specification and the above standards, the present specification prevails. Relevant standards: Israeli Standard IS 65 (IEC Publication 60228) "Conductors of Insulated Cables"; Israeli standard IS 1516-1 (IEC Publication 60502-1) "Extruded Solid Dielectric Insulated Power Cable for Rated Voltages from 1kV up to 30kV". Part 1: "Cables for rated voltage of 1 kv (Um = 1.2 kv)"; CENELEC HD 603 S1 "Distribution Cables of Rated Voltage 0.6/1 kv"; ISO 9001 Quality Management

Page 4 of 17 4 Technical Requirements 4.1 Operating Temperatures 4.1.1 Maximum rated conductor temperature: 90 C. 4.1.2 Short circuit maximum conductor temperature (for duration up to 5 sec): 250 C 4.1.3 The conductor temperature under emergency condition: 130 C for duration of 8 hours continuously. The total duration of such overloads may exceed 100 hours per annum. 4.2 Construction 4.2.1 Conductor 4.2.1.1 Material: The conductor shall be made of plain aluminium, complying with table 2 of IS 65. 4.2.1.2 Form: The conductor shall be circular or sectorial shaped compacted stranded. 4.2.1.3 Dimensions: Table 2 hereafter sets out the shape, cross-sectional areas and characteristics of the conductors covered by this specification. Table 2 Nominal Cross Section (mm 2 ) Minimum Number of Wires Max. DC Resistance at 20 0 C ( /km) 95 15 0.320 240 30 0.125 Shape of the Conductors Sectorial shaped stranded (sm)

Page 5 of 17 4.2.2 Insulation 4.2.2.1 The insulation shall be of extruded cross-linked polyethylene (XLPE). 4.2.2.2 Nominal and minimum thickness values of the insulation, not including the thickness of any Table 3 separator or sheath over the insulation, shall be as specified in Table 3 hereafter (in compliance with IS 1516-1 table 6) Nominal Cross-Section (mm 2 ) 95 Construction sm Nominal Insulation Thickness (mm) Minimum Insulation Thickness (mm) 1.1 0.89 240 1.7 1.43 4.2.3 Cores Identification 4.2.3.1 The identification code color of the phases and neutral of the four core cable (3~ + N) shall be as follows: a) Neutral (N) - BLUE (Preferable light-blue RAL 5012 or sky-blue RAL 5015) b) Phase 1 (R) - BROWN (Preferable loam brown RAL 8003) c) Phase 2 (S) - BROWN with ORANGE strip (Preferable pastel orange RAL 2003) d) Phase 3 (T) - BROWN with BLACK strip 4.2.3.2 The core identification color strips shall be applied by co-extrusion with the core insulation and shall be at the external side of the core. 4.2.3.3 The width of the identifying color strip shall be 15% - 40% of the outer circumference of the insulated core, but not less than 2 mm. 4.2.3.4 The strips shall have decisive contrast compared with the brown background. 4.2.4 Twisting of Cores The four cores shall be twisted together to form a circular cable, keeping a lay ratio max 40 as to the calculated diameter.

Page 6 of 17 4.2.5 Inner Coverings and fillers 4.2.5.1 The material of the inner cover and filler shall be of extruded, non-hygroscopic one that shall be compatible with the insulation material and shall withstand the operating temperatures specified in para. 4.1 of this specification. 4.2.5.2 The extruded inner covering shall have an approximate thickness as specified in table 8 of IS 1516-1 and not less than 0.4 mm at any point of the cable. 4.2.5.3 The filler and the inner cover shall be easily stripped away from the insulation, without leaving any remainders or cause any damage to them. 4.2.6 Oversheath 4.2.6.1 The oversheath shall be of polyvinyl chloride (PVC/A), ST2 type (acc. IS 1516-1 tables 3 and 4); 4.2.6.2 The nominal and minimum thickness of the oversheath shall be as specified in table 4 hereafter (according to sub-clause 13.3 of IS 1516-1); 4.2.6.3 The average of the measured oversheath wall values, rounded to 0.1 mm, shall be not less than the nominal thickness (tn) and the smallest value (tm) measured shall not fall below the nominal thickness by more than 0,1 mm + 15% of the nominal value; Table 4 Nominal Cross-Section (mm 2 ) 95 Construction sm Nominal Oversheath Thickness - tn (mm) Minimum Oversheath Thickness* - tm (mm) 2.2 1.77 240 2.8 2.28 * tm tn (0.1 + 0.15 tn) 4.2.6.4 The color of the oversheath shall be green. 5 Tests 5.1 Type Test

Page 7 of 17 Within 3 months after notification of award, the Contractor shall submit type test report that was performed on the first manufactured batch of the cable to be supply to the IECo. The type test shall be performed according to Annex "A" in an independent authorized laboratory (ISO/IEC 17025 or EN 45011 approved).; The IECo. reserves the right to attend during the performance of the Type Test Exemption: If the Contractor had supplied identical cable to the IECo. during the last 7 years preceding the date of the present bid, and if the manufacturing method was not changed, the Contractor can introduce type test report if it was approved by the IECo. in the former supply. 5.2 Routine Tests The Contractor shall perform and submit test reports for all routine tests for each cable that is wrapped on each drum. The Contractor shall submit to IE Co. the routine test reports for approval prior to delivery of the cable The cable shall be delivered only after approval of the routine test report of the cable. 5.3 Acceptance Test Acceptance tests shall be performed according to the standards in para. 3 and shall include tests required in Routine Test, Special Test and the following tests from Type Test: Test Strength and elongation Test of insulation, before and after ageing. In case that the cable under test will not fulfill all requirements specified in Annex "B" the IECo. has the right to reject the consignment. 5.4 The tests shall be performed by and at the expense of the Contractor. The contractor shall make all the necessary arrangements to enable the IECo. s inspectors to be present at the tests. 5.5 The following data shall be indicated on each test certificate: Manufacturer's name; Name and address of the testing laboratory; Serial number of the test certificate; The certificate issue date; Test report of special test shall specify the pertained batch number of the cables; Manufacturer evaluation of the test result; A signature of the person responsible for tests and his position. 5.6 The test certificate should contain results for each test according to the test requirements with reference to appropriate Clauses and Sub-clauses of standards and this specification.

Page 8 of 17 6 Marking 6.1 Throughout whole cable length, at intervals not exceeding 1 m, the following identification, in white or black marks shall be indelibly imprinted, embossed or by reproduction in relief on the outersheath. Manufacturer s name or trade mark (logo) The structure: "NA2XY (sm) - 4 x (cross-sectional area in mm 2 )" Year of production Nominal rated voltage (U0/U =) 0.6/1.0 kv "Property of the Israel Electric Corp." Running length (in meters) 6.2 The following data shall be printed legibly on a tag strongly attached on each drum: a) Manufacturer's Name b) The IECo. Order. c) Drum Serial. d) Manufacturing Date e) Cable Type (NA2XY) f) 4 X Cross Sectional Area in mm 2 g) Cable Length h) Running length. marked on each of the cable ends ( the first and the last.) i) Gross Weight j) Cable Standard k) The IECo. Catalog. l) The IECo. specification (NPS-91) 7 Packing

Page 9 of 17 7.1 The cables shall be furnished in lengths of 500 (±5) meters wound on seaworthy wooden drums. The cable on the drum shall be protected against damage by suitable cover mounted around the drum flanges. 7.2 Drums dimensions: flange diameter: 2240 mm max., outer width: 1200 mm max., 7.3 spindle hole diameter: 40 80 mm, 7.4 The loosed cable end of at least 1 meter should be fastened to the outer side of the drum's flange with a proper clamp (nails or pegs are unacceptable). The last running meter mark should be visible from the outside. 7.5 An electronic drum-locator device, which will be supplied to the Contractor by the IECo. shall be fixed on the drum side before shipment. 7.6 The cables shall be supplied with hermetically sealed watertight caps that shall prevent the ingress of humidity and fine dust into the cable. 8 Quality Requirements 8.1 For quality system and other specific quality requirements, see Appendix B: Q-APP-02. 8.2 The Bidder shall submit with his proposal the following (In English): Quality system Certificate; Quality manual; Certificates that demonstrate the Bidder's compliance with the requirements specified or implied in this specification; Example of an inspection & test plan and/or Quality plan which pertain to the cable to be supplied; 8.3 Formal confirmation that he will conform to the requirements of Q-APP-02. 9 PROTOTYPE APPROVAL

Page 10 of 17 9.1 Prototype approval for new suppliers. New supplier Supplier that didn t supply the ordered item to the IECorp. in the last five (5) years. 9.1.1 In a period of max three (3) months from notification of award, and before production for IEC of all ordered items, the Contractor shall perform Prototype Approval 9.1.2 For purposes of the Prototype approval, the manufacturer shall perform the complete type tests as required in this specification. 9.1.3 The contractor shall be responsible to conduct successfully all the necessary tests, and to deliver to the Israel Electric Corp. all the necessary required reports, in a manner, which will not interfere with or delay any of the time schedules, pertaining to any action or undertaking, required of the winning bidder, including, but not limited to delivery schedule. Such responsibility shall include proper and reasonable advance notifications to the Israel Electric Corp., prior to any action, required of it. If type and special tests have already been conducted with reference to the identical cable which is offered by the proposed and the Israel Electric Corp. approves the reports, pertaining to such tests, the Israel Electric Corp. shall have a right (but not a duty) to waive all or part of the required tests. 9.1.4 The Israel Electric Corp. reserves the right to cancel the order for the supply of equipment if the prototype will not be approved by the Israel Electric Corp. In any case, the contractor shall not resume manufacture of the rest of the ordered equipment before receiving the Israel Electric Corporation's final approval of the prototype. 9.1.5 Required schedule up to prototype approval (after notification of award) is attached in APPENDIX: "C". 9.2 Prototype approval for existing suppliers. Existing supplier Supplier who supplied the ordered item to the IECorp. in the last five (5) years. 9.2.1 Existing supplier is exempted from prototype if in the technical bid the supplier will provide to IECorp. a letter with the following data: - The period and type of the ordered item supplied to IECorp. - A statement that was no any changes in the production line. 10 - Questionnaire

Page 11 of 17 Tender No.: Name of Proposer: Subject Insert all data in this column Manufacturer s name and address: Specify the standards that the cable will comply: 1 Cable 1.1 Coding 1.2 Rating voltage (U0/U) (kv) 1.2 Current rating in soil (at 30 0 C, thermal resistivity: 1.5 0 Km/W) (A) 1.4 Current rating in air (at 35 0 C ) (A) 1.5 Short circuit rating current for 1 sec duration (ka) 1.6 External diameter of the cable (mm) 1.7 Bending radius (mm) 1.8 Cable weight (kg/m) 1.9 Manufacturing method 2 Conductor 2.1 Material 2.2 Nominal cross-sectional area and form (mm 2 ) 2.3 Number of wires 2.5 DC resistance at 20 0 C (Ω/km) 2.6 Max permissible continuous temp. ( 0 C) 2.7 Max permissible short circuit temp. ( 0 C)

Page 12 of 17 3 - Insulation 3.1 Material 3.2 Nominal thickness (mm) 3.3 Minimum thickness (mm) 3.4 The core identification shall be as in para. 4.2.3 (Yes/No) 4 - Inner Cover and filler 4.1 Material 4.2 Minimum thickness (mm) 5 - Oversheath 5.1 Material 5.2 Minimum thickness (mm) 6 Marking embossed according clause 6 (Yes/No) 7 - Drum 7.1 Type 7.2 Material (wooden/metal) 7.3 Weight of empty drum (kg) 7.4 Flange diameter (mm) 7.5 Barrel diameter (mm) 7.6 Overall Width (mm) 7.7 Gross weight (drum with cable) (kg) 7.8 Length of cable per drum (m) 7.3 The drum shall be protected as required in para.7.2 (Yes/No)

Page 13 of 17 8 - Packing 8.1 A tag with all details as required in sub-clause 7.5 shall be attached (Yes/No) 8.2 The cable shall have sealing caps (Yes/No) 9 - Attached Documents 9.1 Valid ISO 9001 certificate (Yes/No) 9.2 Catalogue (Yes/No) 9.3 Inspection and test plan, QA manual (Yes/No) 9.4 Type test report (Yes/No) Proposer s address: Email address: Contact : Tel. No. : Cellular: Fax. No.: Date: Signature: Annex A,B,C,D

Page 14 of 17 The Israel Electric Corporation Ltd Planning, Development & Technology Division Electrical R & D Laboratory Annex "A" SPECIFICATION NO. S.RL 2702 TEST REQUIREMENTS for CABLES MANUFACTURED ACCORDING TO The IEC SPECIFICATION NPS - 91 Haifa - Israel March, 2017

Page 15 of 17 Annex "B" ORGANIZATION, QUALITY AND SAFETY DIVISION QUALITY CONTROL UNIT APPENDIX FOR CONTRACTS / ORDERS REV. 4 Volume 04 / 2011 Spec. No. Q - APP - 02 QUALITY REQUIREMENTS

Page 16 of 17 APPENDIX "C" - Schedule up to prototype approval (after notification of award) Remarks: 1. Starting point is the date on which a binding contractual obligation has been created, as specified in the invitation to submit proposal. 2. One month before performance of the type tests the contractor shall submit the final test schedule. Week No. STAGE 1 2 3 4 5 6 7 8 9 10 11 12 Submitting of: 1 2 3 4 1. Cross-section drawings including dimensions 2. Test plan: - The name of the performer laboratory and address (country, city, etc.) -List of tests - Plan and schedule of the type test Israel Electric Corp. approval of the above documents after clarifications Execution and submission of the type test report for the proposed item Israel Electric Corp. approval of Type Test Reports 3. The period of time for the delivery approval from the starting point as indicated above will not take more than three 3 months Signature: Date:

Page 17 of 17 APPENDIX "D" - STATEMENT OF MANUFACTURING EXPERIENCE I, (Enter name), do hereby state the following: 1. I am a position holder at ("The factory") occupying the position of (Enter job title and description, i.e. partner, production manager, sales manager, etc.) 2. I have been occupying this position since (Enter date). 3. I give this statement in regards to I.E.C Tender number ("The Tender"). 4. The facts/details given in this statement have been checked and verified by me. 5. (The factory) has experience in production of L.V Cable requested in this Tender at the time of Tender proposal submission and for at least years prior to submission. Signature