>> Australia s leading manufacturer of quality pole products with representation in every state and territory.

Similar documents
Services & Accessories

Standard Pole Range 5. In-Ground Mounted 6. Ground Line Protection 6. Base Plate Mounted 6. Quality & Design Standards 7. Quality Standard 7

MANUFACTURING SOLUTIONS UTILITY POLES L Y P R O U D. Quality ISO 9001 A U

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

TABLE OF CONTENTS INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

Fire Rated Cable Support Systems

RHINO-STOP Modular Vehicle Impact Barriers

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POLES

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

Access. Step Iron. Designed and Manufactured in Australia

Specification for Transport and Erection of Tower Structures

TRACC. Crash Attenuation Cushion. Product Manual

TRACC. Crash Attenuation Cushion. Product Manual

SPECIFICATION SS-20 / 4 STEEL STRUCTURES FOR SUBSTATION AND SWITCHING STATION MATERIAL

OVERSHOT GATE TECHNICAL DATA SHEET

TRACC. Product Manual. Crash attenuation cushion. Release 10/14

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

Technical Specification for Galvanised Fabricated Steelwork

Our world is continually changing and with it, are our ideas, our needs and our challenges.

Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery

BETAFRAMES. Engineered products for the building industry Solutions without compromise. Industry Knowledge. Flexible Manufacturing.

SECTION 2 DIVISION 05 METALS

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED

Product Catalogue Telecommunication Hardware

Conserving Resources. Improving Life.

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

Made in U.S.A. Sunrise Bike Rack Submittal Sheet. Materials: Finishes: Mount Options: Capacity: Setbacks:

Company Directive ENGINEERING SPECIFICATION EE SPEC : 20/4. Relating to Substation Security Fences

National Construction Code Series (NCC 2012) Building Code of Australia (BCA)

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECURING A CONNECTION ANYWHERE RAPID DEPLOYMENT SOLUTIONS RAPID DEPLOYMENT TOWER (RDT)

Specification for the Fabrication of Tower Structures

Technical Specification for Steel Forged Fittings

Technical Memorandum: Road Safety Hardware Series. technical memorandum

STANDARD TECHNIQUE : OH4L/1

BoSS Climalite Camera and lighting tower

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.


T-39 Thriebeam. Product Manual. NCHRP 350 Test Level 3 & 4 Compliant Barrier. Release 01/11

Made in U.S.A. Moai Bike Rack Submittal Sheet. Materials: Finishes: Mount Options: Capacity: Setbacks: 2 Bikes

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Technical Specification for LV ABC Fuse Switch Disconnectors

Electrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

SECTION CHAIN-LINK FENCES AND GATES 02821/1

MSME Testing Centre, 65/1, G. S. T. Road, Guindy, Chennai, Tamil Nadu. Discipline Electrical Testing Issue Date

HOTEL SPECIFICATION SECTION 08100

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

bondek structural steel deck

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces

PRODUCT INFORMATION Dero Hoop Rack

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

STRUT METAL FRAMING SYSTEMS

SECTION CHAIN LINK FENCES AND GATES

SUPPORT AND ANCHORS SECTION 15090

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

Why do Transmission Asset Owners Need a Transmission Restoration System (ERS)? Transmission Line Emergencies Do Occur

STREET LIGHTING GENERAL INFORMATION

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Steel Floor Framing Solutions

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

A-Series Aluminum Gantry Crane

Specification for Fabrication of Steelwork for Pole Structures

FORMDECK. constructions. constructions

TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

SECTION METAL STAIRS

Product Specification

PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces

Chapter 2. Current Design Practice

STRUCTURAL STEEL FRAMING

PRODUCT INFORMATION Dero Rolling Racks

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

Title Transmission Line Maintenance Standards. Reference Number PMP 17 - (RIC Standard: EP SP)

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Special Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following:

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

Flotation Docking Systems, Inc.

Made in U.S.A. Wave Style Bike Rack Submittal Sheet. Materials: 1.5 Schedule 40 Steel Pipe (1.

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

Transcription:

Power Poles

>> Australia s leading manufacturer of quality pole products with representation in every state and territory.

INGAL EPS is a division of Industrial Galvanizers Corporation Pty Ltd which is ultimately owned by Valmont Industries Inc. Actively involved in the Australian pole market since 1969, INGAL EPS has strived to continuously lead the industry in research, design, innovation, quality of product and quality of service. Establishing industry benchmarks such as the Seesaw pole, 60km/h and 110km/h Impact Absorbing poles and the largest steel poles ever installed in both Australia and New Zealand. The company employs around 150 staff and has offices located in every state and territory of Australia and on the North Island of New Zealand. With manufacturing facilities in Brisbane and Perth and full access to three modern facilities in China owned by Valmont Industries Inc, INGAL EPS is well positioned to meet the broad requirements of the pole market. Due to our extensive experience, national coverage, resources and manufacturing capacity we have the ability to provide the most comprehensive product range available. The INGAL EPS product range includes: Street Lighting poles Floodlighting poles Power poles Lowering Systems, for ease of maintenance Special Application poles including banner poles, camera poles, traffic signal and communication poles Services & Accessories providing individual design, drafting, installation and accessories including foundation materials, adaptors, headframes and cross arms. With our dedicated design service, material control, quality assured manufacturing processes and after sales service, INGAL EPS has established itself as Australasia s largest pole supplier. INGAL EPS has over four decades of experience leading the industry in Australia and our ever improving product range and expanded manufacturing resources will continue to ensure we re at the cutting edge of providing new and innovative solutions to a growing and ever more demanding market.

Marlborough Lines 33kV (66kV)

Power Poles PAGE 5 Distribution and Sub Transmission Poles INGAL EPS Distribution and Sub Transmission Poles are the lightest poles available across the full range of length and tip loads. All of the standard range conforms to AS/NZS standards, ASCE/SEI 48-05 and to the ENA Pole Supply and Performance Specification. The length and tip loads of the standard range make INGAL EPS steel poles a direct replacement for the most common timber and concrete poles and with significant advantages. Benefits Lightest poles across the full range of length and tip loads Conform to all relevant AS/NZS standards Conform to ASCE/SEI 48-05 Conform to ENA Pole Supply and Performance Specification (separate documentation) Non combustible with proven bush fire performance Self bonding Impervious to insects and rot Fully recyclable with end of life salvage value Standard poles comprise of, -- 12-sided pole shaft -- Welded top cap -- Mounting holes -- Identification plate -- Earth point above nominal ground line -- Additional in-ground corrosion protection 200mm above and 400mm below nominal ground line -- Anti sink strap -- Hot dip galvanized finish. Pole Shaft and Top Cap The poles shafts are manufactured from sheet steel that has a minimum tensile strength of 450MPa. The welded top cap is usually made from Grade 250 equivalent steel and is not a structural element of the pole. Shafts are all 12-sided to allow for lateral stability and ease of mounting cross arms and other hardware. Mounting Holes Up to ten mounting holes are included in standard pricing (in a configuration to suit the customer) but more can be provided or the poles can be supplied without mounting holes. Drilling mounting holes at the time of dressing a pole is simple and carried out in very much the same way as a timber pole. When holes are drilled post galvanizing, we recommend the use of an organic zinc rich primer on the exposed surfaces prior to assembly. Standard steel distribution poles could have 22mm through holes (two holes at the same level and at 180 degree apart), every 75mm down the pole with negligible affect on strength. In general, 22mm holes could be spaced closer at 50mm apart for groups of six to ten through holes without significantly affecting the design capacity of the overall pole. Generally up to four to eight 22mm holes on adjacent flats of the pole could be placed at the same level if required. The section capacity at that level will be slightly lower but generally the overall pole design capacity should still be able to be achieved.

PAGE 6 Power Poles Additional In-Ground Corrosion Protection Hot dip galvanizing provides an excellent means of corrosion protection above ground and in many circumstances this is all that is required below ground when direct burying poles. However, in some areas soil conditions are such that additional in-ground protection is desirable to extend the life of the pole. The simple theory behind additional in-ground corrosion protection is that by separating soil and oxygen from the metal, you therefore exclude oxidisation. The experience of nearly the last 40 years and research into conditions and performance of products in other markets has led INGAL EPS to recommend three options for additional in-ground protection. Concrete encasing Two-pack epoxy coating Polyethylene wrap Concrete encasing is a time proven performer for additional inground protection. Concrete encasing is not to be confused with foundation mounted poles as encasing is only required from just above the ground line to a depth of 400mm. Two-pack epoxy coatings provide the same tough barrier between the pole and the soil with the additional benefit of being very resistant to line trimmers. The benefits of polyethylene are that it is relatively inexpensive, is self adhesive and can be quickly repaired on site if there s damage during transportation and handling on site. INGAL EPS recommends Coroplast polyethylene wraps. You can read more about Coroplast products at www.coroplast.de. Additional in-ground protection should extend from about 200mm above ground (can be less for concrete encasing) to 400mm below ground. INGAL EPS has also carried out successful UV testing with the CSIRO on the products we recommend, independent of the companies we buy them from. Whether you choose one of our recommendations or specify based on your own preferences, INGAL EPS can apply it so it s ready to go in the ground when it s delivered. Earth Point An M12 steel nut is welded to the pole 200mm above the nominal ground line to serve as an earth point prior to hot dip galvanizing. A hole is drilled in the pole prior to attaching the nut to allow clearance for an M12 bolt. Anti-Sink Strap All distribution poles are provided with an anti-sink strap for across the bottom of the base section. For one piece poles the strap is welded on prior to hot dip galvanizing and for two piece poles it is provided loose with mounting bolts and the top section is transported inside the base section. In this case the holes are predrilled for the bolts provided and the strap is still hot dip galvanized. Hot Dip Galvanizing All hot dip galvanizing is carried out to conform to AS/NZS 4680. Cross Arms Timber, steel and composite cross arms can all be mounted to INGAL EPS steel poles in virtually the same manner as they are mounted to timber poles. No special brackets or cross arm modifications are required. Transformer Mounting and Transition Arrangements The sufficiency of a steel pole to take a transformer is governed by the moment capacity of the steel section at and below the transformer mounting position and in any case the steel pole s ability to carry moment is not inferior to equivalent timber or concrete products. Similarly, you can treat INGAL EPS steel poles in the same manner for transition conductors as you would with a timber pole. The only difference need be the use of a drill bit suitable for drilling steel instead of timber. Polyethylene wrap at the ground line Double circuit 33kV underslung 11kV

Power Poles PAGE 7 Pole Assembly and Handling Poles with an overall length above 12.5m are supplied in multiple sections. These poles require joining (slipping) as per common street lighting poles. The pole slipping and handling process is quite simple and procedures are available. INGAL EPS staff can also be made available for initial on site instruction. Note that although a measurement is used to check the pole has slipped properly, all slip joints are completed to a tonnage applied by a wire rope puller and not by a measurement. After assembly it is safe working practice to temporarily brace the sections together for a crane or helicopter lift. Pole Installation The installation process is very much the same as for other pole types used by electrical utilities but if required installation instruction is available from INGAL EPS. Options and Accessories De-Glare dull galvanising Unlimited variations in the length, diameters, tip loads and hole arrangements Climbing rungs, stiles and ladders Cross arms Other fabricated items as required Product Codes Distribution Poles Distribution Poles 9.5m 11.0m 12.5m 14.0m 15.5m 17.0m DP095016 DP110016 DP125016 DP140016 DP155016 DP170016 DP110024 DP125024 DP140024 DP155024 DP170024 DP=Distribution Pole 095=9.5m 16=16kN Product Codes Sub Transmission Poles Sub Transmission Poles 18.5m 20.0m 22.0m 24.0m 26.0m 28.0m 30.0m 32.0m 34.0m STP185024 STP200024 STP220024 STP240024 STP260024 STP280024 STP300024 STP320024 STP340024 STP185040 STP200040 STP220040 STP240040 STP260040 STP280040 STP300040 STP320040 STP340040 STP185060 STP200060 STP220060 STP240060 STP260060 STP280060 STP300060 STP320060 STP340060 STP185080 STP200080 STP220080 STP240080 STP260080 STP280080 STP300080 STP320080 STP340080 STP=Sub Transmission Pole 185=18.5m 24=24kN 11kV underslung 415V Cross arm arrangement Transformer mounting Transition arrangement

PAGE 8 Power Poles Product Details Distribution Poles Product Code Drawing No. Length (m) Ultimate Tip Load (kn) Weight (kg) Pole Diameter (mm) Top Base Number of Sections Nominal In-ground Depth (m) DP095016 GA2543 9.5 16 224 125 330 1 1.55 DP110016 GA2544 11.0 16 279 125 362 1 1.70 DP110024 GA2545 11.0 24 343 155 440 1 1.70 DP125016 GA2546 12.5 16 338 125 395 1 1.85 DP125024 GA2547 12.5 24 413 155 479 1 1.85 DP140016 GA2548 14.0 16 429 135 413 2 2.00 DP140024 GA2549 14.0 24 532 160 517 2 2.00 DP155016 GA2550 15.5 16 496 135 444 2 2.15 DP155024 GA2551 15.5 24 616 160 556 2 2.15 DP170016 GA2552 17.0 16 568 135 475 2 2.30 DP170024 GA2553 17.0 24 706 160 595 2 2.30 Product Details Sub Transmission Poles Product Code Drawing No. Length (m) Ultimate Tip Load (kn) Weight (kg) Pole Diameter (mm) Top Base Number of Sections Nominal In-ground Depth (m) STP185024 GA3162 18.5 24 838 180 639 2 2.45 STP185040 GA3163 18.5 40 1,236 255 708 2 2.45 STP185060 GA4474 18.5 60 1,696 310 774 2 2.6 STP185080 GA4469 18.5 80 2,045 380 826 2 2.8 STP200024 GA3164 20.0 24 941 180 677 2 2.6 STP200040 GA3165 20.0 40 1,379 255 746 2 2.6 STP200060 GA3166 20.0 60 1,863 310 813 2 2.8 STP200080 GA4468 20.0 80 2,278 380 864 2 3 STP220024 GA3167 22.0 24 1,102 180 727 2 2.8 STP220040 GA3168 22.0 40 1,598 255 796 2 2.8 STP220060 GA3169 22.0 60 2,147 310 864 2 3 STP220080 GA3170 22.0 80 2,606 380 913 2 3.2 STP240024 GA3171 24.0 24 1,316 180 769 3 3 STP240040 GA3172 24.0 40 1,898 255 835 3 3 STP240060 GA3173 24.0 60 2,546 310 902 3 3.2 STP240080 GA3174 24.0 80 3,109 380 948 3 3.4 STP260024 GA3175 26.0 24 1,670 180 819 3 3.2 STP260040 GA3176 26.0 40 2,125 255 885 3 3.2 STP260060 GA3177 26.0 60 2,840 310 954 3 3.4 STP260080 GA3178 26.0 80 3,467 380 997 3 3.6 STP280024 GA4482 28.0 24 1,845 180 870 3 3.4 STP280040 GA4478 28.0 40 2,417 255 935 3 3.4 STP280060 GA4473 28.0 60 3,218 310 1,006 3 3.6 STP280080 GA4467 28.0 80 3,924 380 1,047 3 3.8 STP300024 GA4481 30.0 24 2,080 180 920 3 3.6 STP300040 GA4477 30.0 40 2,878 255 985 3 3.6 STP300060 GA4472 30.0 60 3,546 310 1,057 3 3.8 STP300080 GA4466 30.0 80 4,319 380 1,097 3 4 STP320024 GA4480 32.0 24 2,329 180 971 3 3.8 STP320040 GA4476 32.0 40 3,198 255 1,036 3 3.8 STP320060 GA4471 32.0 60 3,889 310 1,109 3 4 STP320080 GA4465 32.0 80 4,733 380 1,147 3 4.2 STP340024 GA4479 34.0 24 2,733 180 1,010 4 4 STP340040 GA4475 34.0 40 3,600 255 1,074 4 4 STP340060 GA4470 34.0 60 4,707 310 1,147 4 4.2 STP340080 GA4459 34.0 80 5,436 380 1,181 4 4.4

Power Poles PAGE 9 16kN Distribution Poles 24kN Distribution Poles 18.5m 20.0m 22.0m 24.0m 26.0m 28.0m 30.0m 32.0m 34.0m 18.5m 20.0m 22.0m 24.0m 26.0m 28.0m 30.0m 32.0m 34.0m 24kN Sub Transmission Poles 40kN Sub Transmission Poles 18.5m 20.0m 22.0m 24.0m 26.0m 28.0m 30.0m 32.0m 34.0m 18.5m 20.0m 22.0m 24.0m 26.0m 28.0m 30.0m 32.0m 34.0m 60kN Sub Transmission Poles 80kN Sub Transmission Poles

Transpower Double Circuit 220kV

Power POLES PAGE 11 Transmission Poles INGAL EPS individually engineers all Power Transmission poles to suit the specific requirements of each project. Our design flexibility allows for unlimited options such as special cross arms, climbing systems, non-standard pole lengths and varying strength values. Steel poles are an aesthetic alternative to traditional high voltage towers and offer far greater corrosion resilience due to the self cleaning nature of a tapered structure. Steel poles can be designed for use to be installed in lieu of towers without needing to compromise on height and span lengths and offer the advantages of a much smaller easement and greater public acceptance. Longer spans enable line designers to minimise the use of structures and maximise spans to match the limits of the conductor being used. Spacing can be achieved without consideration of pole strength and INGAL EPS can design a pole to meet any loading requirement you have as the conductor will always be the limiting factor. Because of the tapered design of our poles and the grade of material used in our designs, INGAL EPS steel poles are invariably the lightest pole structures available for any transmission line. Benefits Conform to all relevant AS/NZS standards (can be designed for US standards) Poles can be designed up to 75m in height, and with ultimate tip loads of up to 900kN Self bonding Impervious to insects and rot Non combustible with proven bush fire performance Fully recyclable with end of life salvage value Hot dip galvanized finish. Options and Accessories Unlimited variations in lengths, diameters, tip loads, hole arrangements, pole hardware and accessories Poles can be either base plate or in-ground mounted Poles are typically 12 or 16 sided, but can be produced as tapered octagonal or tapered round. Substation Structures

Bass Link 400kV DC

Powerlink Double Circuit 275kV Western Power 132kV Powerlink Double Circuit 110kV Delta River Crossing Structure 66kV

Western Power 132kV

Power Poles PAGE 15 >> street lighting poles >> floodlighting poles >> POWER Poles >> lowering systems >> Special application Poles >> Services & Accessories To view our entire product range, or for the most up to date product information, please visit our comprehensive on-line catalogue at www.ingaleps.com.au

ABN 40 000 545 415 Freecall 1800 623 302 sales@ingaleps.com.au www.ingaleps.com.au www.valmont.com