Similar documents
SECTION CONCRETE FORMWORK

SECTION CONCRETE FORMWORK PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION CONCRETE FORMWORK AND ACCESSORIES

TECHNICAL SPECIFICATION

SECTION CONCRETE FORMWORK

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Division 03 - Concrete Section New Westminister Multi-Use Civic Facility & Office Building Project No Page 1

CONCRETE WALKS AND CURBS SECTION CONCRETE WALKS AND CURBS PART 1 - GENERAL

DIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK

Division 03 Concrete Section includes various guidelines for general concrete use, curing, forming, reinforcing, finishing and concrete accessories.

SECTION MISCELLANEOUS CAST-IN-PLACE CONCRETE

SECTION ARCHITECTURAL CONCRETE

SECTION RIGID PAVEMENT

***************************************************************************************************************

SECTION CAST-IN-PLACE CONCRETE

SECTION CAST-IN-PLACE CONCRETE

CONCRETE FORMWORK. .2 CSA , Supplement No.1 to CAN/CSA , Engineering Design in Wood. .4 CSA O151, Canadian Softwood Plywood.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

***************************************************************************************************************

STRUCTURAL PRECAST CONCRETE

A. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.

***************************************************************************************************************

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

SECTION ARCHITECTURAL PRECAST CONCRETE. A. American Society for Testing and Materials (ASTM):

SECTION CAST IN PLACE CONCRETE PART 1 GENERAL 1.01 RELATED DOCUMENTS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION CONCRETE PAVING

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

This section applies to the design and installation of cast-in-place concrete, shotcrete, precast concrete, and post-tensioned concrete.

SECTION UNIT MASONRY

SECTION PORTLAND CEMENT CONCRETE

Columbia Public Schools Shepard Elementary School Classroom Building Addition PWA I 1 CONCRETE REINFORCEMENT ~4 ASSURANCE

SECTION CAST-IN-PLACE CONCRETE

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

SECTION TILT-UP PRECAST CONCRETE. A. Work includes, but is not limited to, the following:

San Antonio Water System Standard Specifications for Construction ITEM NO. 307 CONCRETE STRUCTURES

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

1. Cast-in place structural concrete including footers, foundations, and other non-slab applications. 2. Formwork 3. Reinforcement

SECTION SHOTCRETE Cast-In-Place Concrete Precast Prestressed Concrete Joists and Beams.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION PRECAST CONCRETE COVER SYSTEM

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Master Specifications for Microcotta November 2017

.1 Formwork for cast-in-place concrete with shoring, bracing, and anchorage.

SECTION US Patent 8,857,130 B1 CAST-IN-PLACE CONCRETE WITH ARDEX CONCRETE MANAGEMENT SYSTEMS (ACMS ) EARLY MC APPLICATION

SECTION CAST-IN-PLACE CONCRETE

1.02 RELATED WORK: Refer to the following sections for related work:

1. Manufacturer certified according to NRMCA's "Certification of Ready Mixed Concrete Production Facilities."

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Student Services & Classroom Addition

STRUCTURAL STEEL FRAMING

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

San Antonio Water System Standard Specifications for Construction ITEM NO. 808 REINFORCED CONCRETE VAULTS

REINFORCED CONCRETE MASONRY SECTION

Product Guide Specification

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

A. Submittal Procedures: See Article 13 of the General Conditions.

SECTION RESILIENT SHEET FLOORING

Project Address: Name of Person Completing Form:

Architectural Wall Products Guide Specifications

MATERIALS A Concrete A.1 Concrete Walk... Mix No. 3F52. A.2 Concrete Walk, Exposed Aggregate Finish... Mix No.

BENTONITE WATERPROOFING

TILE TILE

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION CONCRETE FORMWORK

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION CONCRETE PAVING

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

Octaform Quick Liner Wall & Ceiling Panels Guide Specification CAN Page 1

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SECTION ORCHESTRA PIT FILLER

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

ITEM NO. 307 CONCRETE STRUCTURES

SECTION LIMESTONE SEGMENTAL RETAINING WALLS

Section PANEL SIGNAGE

1. Cast-in-place concrete is specified in Section

SECTION STRUCTURAL STEEL

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Comm. No Multi-Purpose Building (Phase 1) 1 December 2015 First United Methodist Church Waynesboro, Georgia

SECTION METAL STAIRS

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

Transcription:

03100 CONCRETE FORMWORK *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 03 11 00 *************************************************************************************************************** PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 03200 - Concrete Reinforcement 2. 03300 - Cast-in-Place Concrete 3. 04221 - Concrete Unit Masonry 4. 04222 Concrete Unit Masonry (Unreinforced only) 1.2 REFERENCES A. American Society for Testing and Materials (ASTM), latest edition: 1. D994 Specification for Preformed Expansion Joint Filler for Concrete (Bituminous Type). 2. E154) Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls or as Ground Cover. 1.3 QUALITY ASSURANCE A. Codes and Standards: Comply with the following codes, specifications, and standards, except where more stringent requirements are shown or specified: 1. ACI 117/117R Tolerances Compatibility for Concrete Construction. 2. ACI 301 Specifications for Structural Concrete. 3. ACI 318 Building Code Requirements for Structural Concrete. 4. ACI 347R Guide to Formwork for Concrete. B. Qualifications: 1. Formwork Engineer: Professional engineer, with Florida registration and experience in design of formwork and related items. 2. Formwork Contractor: Florida licensed contracting firm having 5 years successful experience in fabrication and erection of formwork systems of similar scope and complexity as required for this project. Contractor shall have sufficient capacity to produce formwork without causing delay in work. 1.4 FORMWORK AND RESHORING DESIGN A. Formwork: 1. Comply with Chapter 4 of ACI 301. 2. Formwork engineer shall perform or oversee design, drawings, erection, and removal. Project No. SPECIFICATION GUIDELINES 03100-1

3. Design according to ACI 117 and ACI 347, including provisions for construction loads and placing equipment to be used on project. 4. Verify strength and stiffness of in-place building elements to resist required loads and restrict deformations to specified tolerances. 5. Earth cuts shall not be used as forms for vertical surfaces. Natural rock formations maintaining a stable vertical cut may be used as side forms. Comply with OSHA's "Trench Safety Act". 6. Design and Installation of Formwork: Form ties that leave through holes in the concrete are not allowed. 7. Removal Strength: B. Reshoring: a. Wall forms and column forms may be removed 12 hours after pouring. b. Slabs supported by precast joists may have forms removed as follows: 1) Joist spacing 4'-6" or less, 24 hrs. 2) Joist spacing between 4'-6" and 6'-8", 48 hrs. 3) Joist spacing between 6'-8" and 8'-8", 72 hrs. c. Beams and other slabs shall not have forms removed until the concrete has achieved 75 percent of its design strength. Beams shall be reshored immediately upon removal of forms. d. In addition to the above, flat slab forms and stair slab forms shall not be removed for 5 days. Upon removal of forms, reshores shall be placed and remain in place until concrete is 14 days old. 1. Design reshoring to resist active loads. 2. Space shoring so no lower floor or member will be excessively loaded from design live loads or will induce tensile stress in concrete members where no reinforcing steel is provided. 3. Extend shores beyond minimums to ensure proper distribution of loads throughout structure. 4. Consider special loading requirements to support load of special elements where elements of similar size and capacity do not exist in supporting structure below. 1.5 FORMWORK SUBMITTALS A. Product Data: Submit manufacturer's product data with application and installation instructions for proprietary materials and items. B. Formwork: 1. Submit shop drawings, signed and sealed by formwork engineer, for fabrication and erection of specific finished concrete surfaces as indicated. Show construction of forms as required. 2. A/E S review is for general applications and features only. Design of formwork for structural stability and efficiency is Contractor's responsibility, and will not be reviewed. C. Reshoring: Project No. SPECIFICATION GUIDELINES 03100-2

1. Submit shop drawings, signed and sealed by formwork engineer, for reshoring system showing: a. Arrangement and sequencing of reshores required. b. Specific areas where reshores do not align vertically. c. Required installation procedures. d. Removal criteria. 2. Submit calculations showing: a. Loading diagrams for each floor or differently loaded area showing maximum imposed loads at each critical sequence. b. Ratio of total load to strength at actual age. c. Verification of member strength where shores do not align vertically. d. Verification of structure to resist required lateral loads. D. Foundations for Formwork and Reshoring: 1. Submit shop drawings, signed and sealed by formwork engineer, or include with formwork and reshoring shop drawings, showing: a. Subgrade preparation required including compaction and moisture control. b. Size and description of sill assemblies. E. Formwork Removal: 1. Authorization for Removal: Formwork engineer shall furnish a signed and sealed report establishing the criteria for removal of formwork, shoring, and reshoring. Deviation from established criteria is not allowed. PART 2 PRODUCTS 2.1 FORM MATERIALS A. Forms for Exposed Finish Concrete: 1. Unless otherwise indicated, construct formwork for exposed concrete surfaces with plywood, metal, or other acceptable panel-type materials. Provide continuous, straight, smooth, exposed surfaces. 2. Furnish in largest practicable sizes to minimize number of joints and to comply with joint system shown on drawings. 3. Provide form material with sufficient thickness to withstand pressure of newly-placed concrete, restricting bow and deflection to specified tolerances. 4. Use plywood complying with U.S. Product Standard PS-1 "B-B (Concrete Form) Plywood", Class I, Exterior Grade or better, mill-oiled and edge-sealed, with each piece bearing legible inspection trademark. 5. Where concrete is scheduled to have Smooth Rubbed Finish (Sm Rb-Fn), use plywood complying with U.S. Product Standard PS-1 "B-B (Medium Density Overlaid Concrete Form", Class I, with each piece bearing legible inspection trademark. Project No. SPECIFICATION GUIDELINES 03100-3

B. Forms for Unexposed Finish Concrete: Form concrete surfaces to be concealed in finished structure with plywood, lumber, metal, or other material. C. Forms for Textured Finish Concrete: 1. Form textured finish concrete surfaces with units of face design, arrangement, and configuration as shown on drawings or as required to match A/E S control sample. 2. Provide form supports to ensure stability of textured form liners. D. Cylindrical Columns and Supports: 1. Form round-section members with paper or fiber tubes, constructed of laminated plies using water-resistant adhesive with wax-impregnated exterior for weather and moisture protection. 2. Prefabricated fiberglass or steel forms may be used. 3. Provide units with sufficient wall thickness to resist loads imposed by wet concrete and restrict deformation to specified tolerances. E. Form Ties: Ties that leave plastic tube lined holes through members are not allowed. F. Form Coatings: Provide commercial formulation form-coating compounds that will not bond with, stain, nor adversely affect concrete surfaces, and will not impair subsequent treatments of concrete surfaces. G. Forming Accessories: CRD-C572-74 polyvinyl chloride (PVC). 1. Waterstops: Flat dumbbell type at construction joints and center bulb type at building expansion joints. 2. Chamfers: 1/2" radius on outside corners of exposed-to-view concrete unless drawings show other size or shape. 3. Drips: 3/8" wide x 1/2" high drip groove placed 3/4" back from edge in cast-in-place exterior soffits. H. Premolded Expansion Joint: ASTM D994, 1/2" thick. I. Vapor Retarder: 1. Provide moisture retarder cover over prepared base material where indicated. 2. Use polyethylene sheet not less than 6 mils thick or other materials resistant to decay when tested according to ASTM E154. PART 3 EXECUTION 3.1 FORMS A. Erect, support, brace, and maintain formwork to support applied vertical and lateral loads until such loads can be supported by concrete structure. Construct formwork so concrete members and structures are of correct size, shape, alignment, elevation, and position. B. Design formwork to be readily removable without impact, shock, or damage to cast-inplace concrete surfaces and adjacent materials. Project No. SPECIFICATION GUIDELINES 03100-4

C. Construct forms to sizes, shapes, lines, and dimensions shown to obtain accurate alignment, location, grades, and level and plumb work in finished structures. 1. Provide for openings, offsets, sinkages, keyways, recesses, moldings, rustications, reglets, chamfers, blocking, screeds, bulkheads, anchorages and inserts, and other features required in work. 2. Use selected materials to obtain required finishes. 3. Solidly butt joints and provide backup at joints to prevent leakage of cement paste. D. Fabricate forms for easy removal without hammering or prying against concrete surfaces. Provide crush plates or wrecking plates where stripping may damage cast concrete surfaces. 1. Provide top forms for inclined surfaces where slope is too steep to place concrete with bottom forms only. 2. Kerf wood inserts for forming keyways, reglets, recesses, and the like, to prevent swelling and for easy removal. E. Provide temporary opening where interior area of formwork is inaccessible for clean out, for inspection before concrete placement, and for placement of concrete. 1. Securely brace temporary openings and set tightly to forms to prevent loss of concrete mortar. 2. Locate temporary openings on forms at inconspicuous locations. F. At chamfers exposed to view, provide corners and edges with 1/2" radius PVC accessories to produce uniform smooth lines and tight edge joints, unless otherwise indicated or accepted by A/E. G. Form Ties: 1. Factory-fabricated, adjustable-length, removable or snapoff metal form ties, designed to prevent form deflection, and to prevent spalling concrete surfaces upon removal. 2. Unless otherwise indicated, provide ties so portion remaining within concrete after removal is at least 1-1/2" inside concrete. 3. Unless otherwise shown, provide form ties that will not leave holes larger than 1 inch diameter in concrete surface. H. Provisions for Other Trades: 1. Provide openings in concrete formwork to accommodate work of other trades. 2. Determine size and location of opening, recesses, and chases from trades providing such items. 3. Accurately place and securely support items built into forms. I. Cleaning and Tightening: 1. Thoroughly clean forms and adjacent surfaces to receive concrete. 2. Remove chips, wood, sawdust, dirt, or other debris just before concrete is placed. Project No. SPECIFICATION GUIDELINES 03100-5

3.2 JOINTS A. Construction Joints: Locate and install construction joints not shown on drawings to not impair strength and appearance of the structure, as acceptable to A/E. B. Provide keyways at least 1-1/2" deep in construction joints in walls, slabs, and between walls and footings. Accepted bulkheads designed for this purpose may be used for slabs. C. Place construction joints perpendicular to the main reinforcement. Continue reinforcement across construction joints. D. Waterstops: 1. Provide waterstops in construction joints as indicated. 2. Install waterstops to form continuous diaphragm in each joint. 3. Make provisions to support and protect exposed waterstops during progress of work. 4. Fabricate field joints in waterstops according to manufacturer's printed instructions. E. Isolation Joints in Slabs-on-Ground: 1. Construct isolation joints in slabs-on-ground at points of contact between slabs on ground and vertical surfaces, such as column pedestals, foundation walls, grade beams, and elsewhere as indicated. 2. Joint filler and sealant materials are specified in Division 7 sections of these specifications. F. Contraction (Control) Joints in Slabs-on-Ground: 1. Construct contraction joints in slabs-on-ground to form panels of patterns as shown. 2. Use inserts 1/4" wide x 1/4 of slab depth, unless otherwise indicated. G. Form contraction joints by inserting premolded hardboard or fiberboard strip into fresh concrete until top surface of strip is flush with slab surface. After concrete has cured, remove inserts and clean groove of loose debris. 1. 2. Contraction joints may be formed by saw cuts as soon after slab finishing as possible without dislodging aggregate. 3.3 RE-USE OF FORMS A. Clean and repair surfaces of forms to be re-used in work. Split, frayed, delaminated, or otherwise damaged form facing materials are not acceptable for exposed surfaces. Apply new form coating compound as specified for new formwork. B. When forms are extended for successive concrete placement, thoroughly clean surfaces, remove fins and laitance, and tighten forms to close joints. Align and secure joint to avoid offsets. Do not use "patched" forms for exposed concrete surfaces, except as acceptable to A/E. END OF SECTION Project No. SPECIFICATION GUIDELINES 03100-6