Introduction to Geothermal Comfort Systems in INDIA

Similar documents
Introduction to Geothermal Comfort Systems in INDIA

Ground Source Heat Pumps for Homes. Things are changing. International Ground Source Heat Pump Association (IGSHPA)

Geothermal Heat Pumps: Harnessing On-Site Renewable Energy to Meet Energy-Efficiency and Climate Change Goals

BETTER BUILDINGS BY DESIGN Sheraton Conference Center Burlington, Vermont. February 8, 2012

Welcome Everyone. Not Quite this kind! Geothermal Heat Pumps are a indirect solar heating system! Introduction to Geothermal

GEOTHERMAL OVERVIEW. Presented by John Cole East Coast Account Rep. for RENEWABLE ENERGY. Construction Automotive Industry

Geothermal Alliance of Illinois Sales and Marketing for Technicians

DOE Webinar Residential Geothermal Heat Pump Retrofits

GEOTHERMAL HEAT PUMPS CONFIGURATIONS/INSTALLATION

The basic elements of the system include: Buried loops of piping (the ground loop); A biodegradable liquid antifreeze;

G eothermal. S ystems. The Earth Connection

White Paper. Geothermal Heating and Cooling

WaterFurnace Explains

Geothermal HVAC Systems - The Basics and Applications (Draft) George Hu, P.E., LEED AP Air Water Energy Engineers, Inc.

Geothermal energy can be harnessed through

Geothermal Heating & Cooling in Health Care Applications

Go Green, Get Geo! GEOTHERMAL SYSTEMS GEOEXCEL: ULTIMATE PERFORMANCE AND RELIABILITY GEO-411. Geothermal Loop Types

geoexchange as an alternative energy source DESIGN APPROACHES

Cares renewable ENERGY

Geothermal Heat Pumps What are they and how do they work?

Geothermal Heat Pump Systems Being Green by using the Ground

Chapter 9: Applications of the Laws of Thermodynamics

Geothermal Comfort Systems

WaterFurnace Explains GEOTHERMAL HEATING & COOLING

Mechanical System Study

Ground Source Heat Pumps

For more information about Ground Source Heat Pumps, call the Member Service Department at or visit our website at

RESIDENTIAL Q&A IS GEOEXCHANGE HEATING & COOLING RIGHT FOR YOU?

Ground-source Heat Pumps State of the Art

The Role of Thermal Potential in Enhancing Energy Efficiency / Productivity

PROPOSAL FOR THE PROMOTION OF GEOTHERMAL HEATING FOR THE TOWN OF MONO. June 2009 CONTENTS

The American Council for an Energy-Efficient Economy Emerging Technologies Report. Residential Ground-Source Heat Pumps July, 2007

CITY OF ORONO HENNEPIN COUNTY, MINNESOTA

Section II: Defining Ground Source

Evaluation of Vertical and Horizontal Geoexchange Systems

What is a ground source heat pump?

Magma On the other hand, molten rock is under active volcanoes at accessible depths. The temperatures excess 650 o C.

Green Movement Energizes Growth at ClimateMaster. Product Focus: Heating and Cooling. Company Profiles. plumbing heating cooling.

Bifluid Geothermal System New Generation

Global Warming and Geothermal Heat Pumps

Applying Geothermal Technology for Large Scale Projects

District GeoExchange Systems & Waste Heat Recovery

Quality concrete paving products

Mechanical Redesign. Existing System: The following schematic was devised below.

Alaska Geothermal LLC Geothermal Heat Pumps. Alternatives for Heating, Cooling & Domestic Hot Water Production

Danish Development Center for District Energy

3/6/2017 Past president & currently on the board of directors for the Wisconsin Geothermal Association

Mechanical Depth. Redesign and Analysis

MULTI-YEAR OPERATION EFFECT OF GEOTHERMAL HEAT EXCHANGER ON SOIL TEMPERATURE FOR UNT ZERO ENERGY LAB. Vinayak P. Walikar

Energy Savers: Air-Source Heat Pumps

GPC ONE PLANETS CONSULTANTS LTD

Special to Licensed Architect Ground Source Heat Pumps - Conditioning a Building Near You

EXPERIMENT FOR VERIFICATION OF GROUND SOURCE HEAT PUMP USING THE DIRECT EXPANSION METHOD

THE GEOTHERMAL ADVANTAGE

Geothermal Heat Pump Systems Metropolitan Washington Council of Governments Built Environment and Energy Advisory Committee May 19, 2016

Multi-Positional Vertical Packaged

Geothermal H.V.A.C. Systems in High Performance Buildings

2 nd Law of Thermodynamics

Renewable Energy. Visible light. Cool air. Warm air. Condensation. Precipitation. Evaporation

In-Depth Exploration of Ground Source Heat Pump Technologies

Physics 100 Lecture 23. Geothermal Energy April 23, 2018

Second Law of Thermodynamics

Energy from the Earth. Geothermal Two very different methods Tides, waves, currents. Unit 12 Energy from the earth - Slide 1

Heat pumps. WP5 Education and Economic Promotion

Geo-Exchange Technology and Application. Ontario Building Officials Association 2013 Annual Meeting and Training Session B.

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

Research and Development Initiative

EVALUATION OF GROUND COUPLED HEAT PUMPS FOR THE STATE OF WISCONSIN

Required Treatment of District Thermal Energy in LEED-NC version 2.2 and LEED for Schools

The Implementation of Low Temperature District Energy Systems using GeoExchange Technology

GeothermalXperts, Inc. A DIVISION OF

Geothermal Heating and Cooling Overview. Why should I consider it?

Geothermal Heat Pump Systems Being Green by using the Ground. Presented by: Warren (Trey) Austin, PE, CEM, CGD, LEED-AP Geo-Energy Services, LLC

Other Names for Ground Loop Systems

DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

30 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Ground Source Heat Pumps (AKA Geothermal Heat Pump or Geoexchange): E3A Folder Forthcoming. Milton Geiger, CEM, REP Fairbanks, AK April 15, 2014

ABS Group of Companies. Thermal Energy Rejector.

Chapter 8. Vapor Power Systems

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Ground-Coupled Heat Pump And Energy Storage

Energy Efficiency & Renewable Energy Resources

Exploiting the Free, Renewable Energy, Above and Below your Farm. Michigan State University March 10, 2016

A PILOT PROJECT OF THE CLOSED-LOOP GROUND SOURCE HEAT PUMP SYSTEM IN CHINA

Renewable Energy Alternatives

ECONET Meeting #3. Bucharest the 12 th of November, 2017

30 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Renewable Heat for Renewable Cities: Geoexchange Heating and Cooling: Introduction and Case Study of St Peters College Sports Centre

Trane Water-Source Variable Refrigerant Flow

Renewable Energy Systems 10

Guide. Heat Pump Boilers. Information. Issue Ten >

EPUB // WHAT IS GEOTHERMAL HEAT DOCUMENT

Turn off fossil fuels. Turn on the power of nature. Energy Audits Hot Water Solutions. Solar Electricity Heat Pumps

Ground Source Heat Pump System Performance: Measuring the COP

AIR FORCE INSTITUTE OF TECHNOLOGY

Energy Source Uses. Biomass

Geothermal Comfort System. 5 Series 500A11

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

GEOTHERMAL HEAT PUMPS. Q & a. Modern Geothermal HVAC Engineering Applications and Controls- McGraw-Hill 2013

Transcription:

Introduction to Geothermal Comfort Systems in INDIA History Ancient earth sheltered homes 1912 Swiss Patent 1945 -First GSHP operating in North America in Indianapolis 1949 Canada s s first GSHP installation in Toronto 1970 -First European installations

Alternate Energy Sources have Tax Credit Wind Generators Wind farms, Wind turbines easy to see Works great when wind blows Solar Panels Solar panels on roofs easy to see Works great when sun shines Ground Source Heat Pump (GSHP) Homes, schools, businesses, gov Can t t see it work and no noise Works 24hrs/7days per week /365 days a year 4

Defining Geothermal Energy Dictionary definition Relating to the internal heat of the earth High Temperature Geothermal Refers to heat temperatures from typically hundreds of feet deep within the earth, sometimes exceeding 300 F. These include geysers and other hydro- geothermal reservoirs. Defining Geothermal Energy Low Temperature Geothermal Refers to shallow earth temperatures found anywhere, utilizing a mechanical device (geothermal heat pump) to transfer heat to and from the ground.

What is Geothermal Energy? The transfer of energy to and from the earth for the purposes of heating or cooling a building or process. Two primary energy sources or sinks: Earth core dominated Surface dominated The Technology Goes by Many Different Names Ground source heat pumps (GSHP) Ground coupled heat pumps (GCHP) Geothermal heat pumps (GHP) Geo Exchange (GX) Earth energy systems Water source heat pump (WSHP) Refers to units used in boiler/cooling tower applications without a direct connection to the earth, WSHP systems are not geothermal applications

What is a Geothermal Heat Pump? It s an electrically-powered device that uses the natural heat storage ability of the earth and/or the earth s groundwater to heat or cool your home or business. How do you get earths energy? Earth absorbs almost 50% of all solar energy and remains a nearly constant temperature of 50 F F to 70 F F depending on geographic location. Cooling-In the summer,, the system reverses and expels heat from your home to the cooler earth via the loop system. This heat exchange process is not only natural, but is a truly ingenious and highly efficient way to create a comfortable climate in your home. Heating-In winter,, water circulating inside a sealed loop absorbs heat from the earth. Here it is compressed to a higher temperature and sent as warm air to your indoor system for distribution 10 throughout your home.

How is heat transferred between the earth and the home? Using the stored energy of the earth, heat is extracted through a liquid medium (groundwater or an anti-freeze solution) and is pumped to the heat pump or heat exchanger. There, the heat is used to heat your home. In summer, the process is reversed and indoor heat is extracted from your home and transferred to the earth through the liquid. How does it work? Like any type of heat pump, it simply moves heat energy from one place to another. Your refrigerator works using the same scientific principle. By using the refrigeration process, geothermal heat pumps remove heat energy stored in the earth and/or the earth s groundwater and transfer it to the home.

How Low Temperature Ground Heat is Converted to Home Heating 145 F OUT 55 F 60 F Air Temp 105 F IN 61 F 56 F 92 F 13 Heating and Cooling System all in one! You can change from one mode to another with a simple flick of a switch on your indoor thermostat. In the cooling mode, a geothermal heat pump takes heat from indoors and transfers it to the cooler earth through either groundwater or an underground loop system.

Overall Concept A Ground Source Heat Pump System consists of a water-to to-air or water-to to-water heat pump, connected to a series of long plastic pipe buried below the earth's surface, or placed in a pond. These systems can also utilize well water in place of the earth loop. As fluid from the earth loop or well water is moved through the unit, the heat pump transfers thermal energy. Energy Source The earth serves as a giant solar collector, storing heat energy. Air temperatures may fluctuate as much as 50 F F above and below the annual average. However, only a few feet below the surface, the changes in earth temperatures are much less severe.

Energy Source During the heating season, the earth serves as a heat SUPPLY. (HE - Heat of Extraction) Source During the cooling season, the earth serves as heat STORAGE. (HR - Heat of Rejection) Sink Typical Traditional HVAC System

How do you get earths energy? 100% 17% reflected by clouds. Space 6% reflected by surface. 19% absorbed by water vapor, dust 4% absorbed by clouds. Atmosphere 19 46% absorbed by ground The earth is like a solar battery absorbing nearly half of the sun s energy. The ground stays a relatively constant temperature through the seasons, providing a warm source in winter & a cool heat sink 19 in summer. Earth Laws of Thermodynamics In order to fully understand HOW a geothermal system works, you need a basic understanding of the First & Second Laws of Thermodynamics.

The First Law of Thermodynamics Otherwise known as the Law of Conservation of Energy Basically, you can t t get more energy out than you put in. The Second Law of Thermodynamics The first statement in the Second Law of Thermodynamics is that heat energy flows from an area of high heat to a area of low heat. You cannot stop this process, only speed it up or slow it down.

180 F HWS 160 F HWR Air Air 82 F 82 F Natural Gas Boiler 100 F 52 F 42 F Chiller 90 F Cooling Tower How Does a Geothermal System Fit in an HVAC System??

The Basic Ground Source Heat Pump System The earth loop is placed in the ground either horizontally or vertically, or it can be placed in a pond. Water and anti-freeze is circulated through the pipe, transporting heat to the heat pump during the heating mode and away from the heat pump during the cooling mode. The heat transfer takes place inside the heat pump in a water-to to-refrigerant heat exchanger called the coax. The Renewable Energy Component Electricity 1 Unit 4 Units of Space Heat Delivered 3 Units Earth Energy 1 unit of energy is used to transfer 3: COP=4

Transfer Rather Than Generate It requires less thermodynamic effort to transfer heat than to generate it through combustion. How do we Pump Energy? The mechanical refrigeration cycle!

Heat Pump Operation Geothermal heat pumps consist of four circuits: Distribution circuit The system that distributes the conditioned air or water solution throughout the home or building and returns it to the unit. Refrigerant circuit A sealed and pressurized circuit of refrigerant including compressor, expansion valve, water-to to-refrigerant heat exchanger(s), air coil, reversing valve. The refrigerant is either R-22 or R-410A. R Heat Pump Operation Geothermal heat pumps consist of four circuits: Ground loop circuit The piping system buried in the ground has fluid that is circulated by pumps to and from the geothermal unit. Hot water circuit Domestic water can be heated in a geothermal unit with a device called a desuperheater.. A piping connection is made from the geothermal unit to the water heater.

Geothermal System Components Ground-Loop Ground-Loop Pump (in unit) A Source Heat Exchanger A Refrigeration Circuit A Compressor A Metering Device A Load Side Heat Exchanger A Load Side Fan or Pump How the earth works to save you energy! Cooling Geo4VA - This is a Special Energy Project funded by the U.S. Department of Energy's State 32 Energy Program through the Virginia Department of Mines, Minerals, and Energy.

How the earth works to save you energy! Heating 60 F 145 F 60 F Air 105 F 55 F 61 F 56 F 130 F 145 F 92 F 92 F Geo4VA - This is a Special Energy Project funded by the U.S. Department of Energy's State 33 Energy Program through the Virginia Department of Mines, Minerals, and Energy. Heat Pump Operation Each of these circuits is closed and sealed from the others there there is no direct mixing. However, heat energy does transfer from the refrigeration circuit to the other three circuits. The refrigerant flow will change direction when the unit changes modes (heating or cooling).

Heat Pump Operation The Four Circuits in a Geothermal Heat Pump Distribution Circuit = Flow of Energy (Heat) Refrigeration Circuit Earth Loop Circuit Hot Water Circuit The Basic Refrigeration Cycle Compressor Low Pressure Vapor State High Pressure Vapor State Evaporator Condenser Low Pressure Liquid State High Pressure Liquid State TXV

The Refrigeration Cycle Heating Mode Operation The Refrigeration Cycle Cooling Mode Operation

The Refrigeration Cycle Hot Water Assist Operation & Piping Equipment Performance Ratings Geothermal and ground water heat pumps are tested under ISO Standard 13256-1, which replaces the former standards of ARI-330 (ground loop), ARI-325 (ground water / open loop) and ARI-320 (water loop / boilertower).

Equipment Performance Ratings This standard uses different entering water temperatures for heating and cooling. The following are rating points for ground water and ground loop heat pumps. ISO Standard 13256-1 Testing Criteria Ground Water Units Units @ Part and full capacity operation Entering water temperature cooling 59 F F (15C) Entering water temperature heating 50 F F (10C)

ISO Standard 13256-1 Testing Criteria Ground Loop Units Units @ full capacity operation Entering water temperature cooling 77 F F (25C) Entering water temperature heating 32 F F (0C) Units @ part capacity operation Entering water temperature cooling 68 F F (20C) Entering water temperature heating 41 F F (5C) Equipment Performance Ratings The efficiency ratings for water-to to-air heat pumps as: Energy Efficiency Ratio (EER) EER = BTU output divided by power watt input For cooling operation under steady state test conditions Coefficient of Performance (COP) COP = BTU total output divided by BTU input For heating operation under steady state test conditions

The Ground Loop. The ground/earth loop provides the infrastructure for accessing and continually exchanging thermal energy between the earth and the building. Closed-loop loop system a continuous, sealed, underground or submerged heat exchanger through which a heat-transfer transfer fluid is circulated between the ground and the heat pump during a run mode. Open loop or groundwater system a system designed to use groundwater for the purpose of extracting or rejecting heat by use of a liquid-source heat pump. Closed Ground Loop Closed Loop systems are installed in various configurations dependent upon site characteristics: Vertical closed loop: A tighter footprint to install the ground loop. Horizontal closed loop: A large area of exposed land. Lake loop (closed): A water source is close to the building.

How a Ground Source Heat Pump System Works for a Residence Horizontal System Vertical System Image courtesy of Climate Master Image courtesy of Climate Master 47 Other Ground Source Systems Lake Loop Open Loop Image courtesy of Climate Master Lake Loop are usually very economical to install. If a pond or lake at least 8 feet deep is available, lake loops can utilize the water (rather than soil) for heat transfer. Reduced installation costs are characteristic of this type of loop system. Image courtesy of Climate Master Open Loop installations actually pump water from an underground aquifer through the geothermal unit and then discharge that water to a drainage ditch or pond. Discharging water to a pond or lake is 48 considered ideal.

Ground Open Loop System Groundwater systems -groundwater is available at reasonable depth and temperature. The groundwater is pumped from the delivery well to the heat pump and from there to the sink well or lake or ditch. Heat Pump 49 Closed Ground Loop Ground temperatures Depth < 15 m (49.21 ft): Ground temperature fluctuates according to ambient conditions. Depth ~ 15 m (49.21 ft): Ground temperature approximates mean annual air temperature. Depth > 15 m (49.21 ft): Ground temperature increases slightly with depth. This increase called the geothermal gradient is about 2 C per 100 m (1 F per 100 ft).

Ground Closed Loop System Trenching Trenching-horizontal horizontal loops with one or more pipes in loops. 4-5 4 deep. Or Vertical Boring vertical loop bore hole with one pipe down hole looping back to surface. Restricted space. Or Directional Boring -horizontal loop that can be under a building or parking lot. Vertical Boring Directional Boring 51 Closed Ground Loop Typical Vertical Ground Loop Circuit Tie-In U-tube can range in diameter from ¾ to 1 ¼ inch (1 inch most common) 150 300 ft. typical depth Reverse Return piping arrangement

Closed Ground Loop Multiple borehole piping fused together in reverse return configuration creating a circuit Geothermal Potential in India

ADVANTAGES OF GEOTHERMAL WATER SAVING ENERGY EFFICIENT LONG LIFE NO MAINTENANCE EASY INSTALLATION ADVANTAGES OF GEOTHERMAL Reduces Pressure from Grid Reduces Dependence on Imported Oil Reduces Installation Size and Operating Cost of Captive Power Generator Going Geothermal adds Points towards Higher level of LEED Certification with Indian Green Building Council

INTRODUCTION Indian Chapter was formed in February 2013 Initiated by Dr Prem C Jain and Mr Kamal Meattle Working committee was formed All statuary registrations were done. Opened the forum for taking 100 founding members Regular committee meetings are conducted PROMOTIONS At ACREX 2013 at Mumbai E-mailers with membership form were sent. Forms are being distributed at select Ishrae and Ashrae functions Supporting and partnering ACREX 2014 being held in New Delhi in February, 2014

Government Affairs Held meetings with MNRE, IREDA and BEE Dr R N Sawant,, Director (Geothermal) of MNRE is supporting the movement. Finalization of two zones in Five climatic conditions of India for testing (Thermal Conductivity) of Geothermal potential is in progress. Subsidy options on Geothermal cooling systems is being initiated Government Affairs Promoting Geothermal as Renewable Energy Promoting Geothermal as Energy Efficient system Working out financing options for Geothermal System under Energy Efficiency funds. Pilot project of Government being initiated. Talks with Bureau of Energy Efficiency (BEE) for promoting Geothermal to be initiated.

INDIAN CLIMATIC ZONES FEW PROJECTS IN INDIA Ministry of Environment and Forest, New Delhi DRDO in Himachal Pradesh. Hotel in Mohali.

FEW COMPANIES PRESENT IN INDIA Carrier Geo-infinity GIBBS Climate Master BOSCH Water Furnace WAY FORWARD Pilot Project Arranging Training for Design Engineers Arranging Training for Drillers Steps to enhance awareness with Regulators Steps to expand subsidy to GSHP projects Awareness in Building Industry

QUESTIONS PLEASE? THANK YOU FOR YOUR TIME AND ATTENTION!