zyvex TEM Sample Lift-out Using the Zyvex Nanoprober System By Kimberly Tuck, Zyvex Corporation

Similar documents
Using Zyvex Microgrippers TM with Zyvex Nanomanipulators

MECH 466. Micro Electromechanical Systems. Laboratory Manual Laboratory #4: Microassembly of MEMS

Why Probes Look the Way They Do Concepts and Technologies of AFM Probes Manufacturing

Microfabrication of Heterogeneous, Optimized Compliant Mechanisms SUNFEST 2001 Luo Chen Advisor: Professor G.K. Ananthasuresh

Specimen configuration

Specimen Preparation Technique for a Microstructure Analysis Using the Focused Ion Beam Process

Surface Micromachining

MODEL PicoMill TEM specimen preparation system. Achieve ultimate specimen quality free from amorphous and implanted layers

3D Nano-analysis Technology for Preparing and Observing Highly Integrated and Scaled-down Devices in QTAT

Proceedings Post Fabrication Processing of Foundry MEMS Structures Exhibiting Large, Out-of-Plane Deflections

Scanning thermal microscopy probe capable of simultaneous electrical imaging and the addition of a diamond tip

Poly-SiGe MEMS actuators for adaptive optics

Maxim Integrated Global Failure Analysis (FA)

Advanced Manufacturing Choices

MODEL NanoMill TEM Specimen Preparation System. Ultra-low-energy, inert-gas ion source. Concentrated ion beam with scanning capabilities

Application Note. Sample Protection prior to FIB Processing. related instruments: Leica EM ACE600. Material Research. Life Science Research

In situ TEM Characterization of Shear Stress-Induced Interlayer. Sliding in the Cross Section View of Molybdenum Disulfide

THIN METALLIC LAYERS STRUCTURED BY E-BEAM LITHOGRAPHY. Miroslav HORÁČEK, Vladimír KOLAŘÍK, Michal URBÁNEK, František MATĚJKA, Milan MATĚJKA

Tensile Testing of Polycrystalline Silicon Thin Films Using Electrostatic

Metallic microgripper with SU-8 adaptor as end-effectors for heterogeneous micro/nano assembly applications

Surface Layer Characterization of Atomized Magnesium for use in Powder Metallurgy Products Paul Burke and Georges J. Kipouros

ENMAT101A Engineering Materials and Processes Associate Degree of Applied Engineering (Renewable Energy Technologies) Lecture 10 Practical Microscopy

ELECTRON MICROSCOPY MODERN SURFACE, LAYER AND DEFECT ANALYSIS USING REM, FIB, EDX, STEM

MODEL SEM Mill. Two independently adjustable TrueFocus ion sources

Model TEM Mill. Tabletop precision preparation for producing high-quality TEM specimens from a wide variety of materials EXCELLENCE MAGNIFIED

Microstructural Characterization of Materials

Specimen Preparation of Metals and Alloys for Atom Probe Tomography by Electropolishing

Micro-Nano Fabrication Research

Control of connecting rods

General Introduction to Microstructure Technology p. 1 What is Microstructure Technology? p. 1 From Microstructure Technology to Microsystems

Polymer Microfabrication (Part II) Prof. Tianhong Cui, Mechanical Engineering ME 8254

Silver Diffusion Bonding and Layer Transfer of Lithium Niobate to Silicon

There are basically two approaches for bulk micromachining of. silicon, wet and dry. Wet bulk micromachining is usually carried out

High Throughput Laser Processing of Guide Plates for Vertical Probe Cards Rouzbeh Sarrafi, Dana Sercel, Sean Dennigan, Joshua Stearns, Marco Mendes

Shock Testing of MEMS Devices

MODEL 1051 TEM Mill ION MILLING. Ion milling is used on physical science. specimens to reduce thickness to electron

Ion Beam Technology. FIB Nanofabrication at Its Excellence

4. Process Integration: Case Studies

Sample Repositioning Solutions for

Laser Micromachining for Industrial Applications and R&D. 3D-Micromac AG. Symposium on Smart Integrated Systems in Chemnitz. 3D-Micromac AG

Simple method for formation of nanometer scale holes in membranes. E. O. Lawrence Berkeley National Laboratory, Berkeley, CA 94720

Part Description Image Part Number

Metallurgy 101 (by popular request)

Automotive Electronics Council Component Technical Committee

SUPPLEMENTARY INFORMATION

Welcome MNT Conference 1 Albuquerque, NM - May 2010

Focused Ion Beam CENTRE INTERDISCIPLINAIRE DE MICROSCOPIE ELECTRONIQUE. Marco Cantoni, EPFL-CIME CIME ASSEMBLEE GENERALE 2007

Scanning Electron Microscope & Surface Analysis. Wageningen EM Centre Marcel Giesbers

MODEL TEM Mill. Two independently adjustable TrueFocus ion sources

MODEL Plasma Cleaner. Simultaneously cleans specimen and specimen holder. Cleans highly contaminated specimens in 2 minutes or less

Development of Heat Resistant Stainless Steel NSSC 21M for Catalysis Substrate of Motorcycle Muffler

John de Laeter Centre

CHARACTERIZATION OF ELECTROTHERMAL ACTUATORS AND ARRAYS FABRICATED IN A FOUR-LEVEL, PLANARIZED SURFACE-MICROMACHINED POLYCRYSTALLINE SILICON PROCESS

IBS/e Ion Beam Sputter Deposition and Etching System. IBS/e with KDC-10 Ion Beam Sputter Deposition and Etching System with Kaufman Ion Source

Application Note #124 VITA: Quantitative Nanoscale Characterization and Unambiguous Material Identification for Polymers

In-situ Electron Microscopy Mechanical Testing for Steels

MEMS II: January 23. Lab 1: Pop-up mirror - PolyMUMPS - Thermal actuators - Mirror CoventorWare

SUPPLEMENTARY INFORMATION

In Situ Observation of Dislocation Nucleation and Escape in a Submicron Al Single Crystal

Nanoscale Imaging, Material Removal and Deposition for Fabrication of Cutting-edge Semiconductor Devices

Tackling the optical interconnection challenge for the Integrated Photonics Revolution

Module 4 Design for Assembly

FEI Materials Science Driving Discovery Through Innovative Solutions

ise J. A. Woollam Ellipsometry Solutions

MEMS Packaging Techniques for Silicon Optical Benches

Product Information Version 2.0. ZEISS ORION NanoFab Three Ion Beams for Enhanced Flexibility in Sub-10 nm Fabrication

Research of Structure and Technology for the Micro- Machined Airflow Inclinometer

MEASUREMENTS OF MECHANICAL PROPERTIES OF MICROFABRICATED THIN FILMS

MODEL 1061 SEM Mill ION MILLING. Ion milling is used in the physical. sciences to enhance the sample s surface. characteristics. Inert gas, typically

Motorola PC603R Microprocessor

Evaluation of Mechanical Properties of Hard Coatings

MECHANICAL PROPERTIES.

Effect of titanium on the near eutectic grey iron

Industrial Applications. Cool Laser Machining.

Electrical Characterization of Tungsten Nanowires Deposited by Focused Ion Beam (FIB) *

Surface micromachining and Process flow part 1

AUTOMATION Production stud welding equipment and systems

TED PELLA, INC. Microscopy Products for Science and Industry

Maintenance and Use of the MICROPOSITION PROBE

FUSION IN SITU HEATING AND ELECTRICAL. Protochips Quantifiably Better

Cambridge University Press A Guide to Hands-on MEMS Design and Prototyping Joel A. Kubby Excerpt More information.

Chapter 3: Powders Production and Characterization

MEMS and Nanotechnology Research at TST

Sensors and Actuators Designed and Fabricated in a. Micro-Electro-Mechanical-Systems (MEMS) Course. Using Standard MEMS Processes

Transzmissziós és pásztázó elektronmikroszkópos minták készítése ionsugaras vékonyítással

INSPECTION LINE FOR RAILS

LEAP 5000 & EIKOS Consumables, Accessories, and Options

EECS130 Integrated Circuit Devices

Measuring of doping profiles with Spreading Resistance Profiling. Wolfgang Treberspurg (HEPHY Vienna)

From Eye to Insight. Leica EM ACE. Coater Family

Supporting information. In-situ TEM observation of phase transition of nanoscopic patterns on. baroplastic block copolymer film during nanoindentation

MEMS Fabrication. Beyond Integrated Circuits. MEMS Basic Concepts

Metrology at the Nanoscale What are the Grand Challenges?

Productivity and efficiency in automation SKF solutions for assembly and handling

FABRICATION PROCESSES FOR MAGNETIC MICROACTUATORS WITH POLYSILICON FLEXURES. Jack W. Judy and Richard S. Muller

Hysitron TI 980 TriboIndenter. Innovation with Integrity. Tribology and Mechanical Testing

Hysitron TI 980 TriboIndenter. Innovation with Integrity. Tribology and Mechanical Testing

For More Information Contact: Zebra Communications

Transcription:

TEM Sample Lift-out Using the Zyvex Nanoprober System By Kimberly Tuck, Zyvex Corporation Introduction The Zyvex Nanoprober System, coupled with a focused ion beam (FIB) tool, is a complete solution for TEM sample preparation. The Zyvex System has the ability to perform the following tasks in a dual beam FIB (dbfib) environment (see Figure 1). Probe bulk samples Take electrical measurements Manipulate samples Perform immediate in-situ transmission electron microscope (TEM) sample lift-out The ability to prepare site-specific specimens (that can be removed from the bulk of a sample) provides more insight into defect analysis, process monitoring and control, and materials characterization of increasingly smaller areas. This is an extremely important application. The Zyvex Nanoprober (Figure 2) is capable of performing the standard in-situ lift-out method using a tungsten probe along with FIB micro-machining and welding. Zyvex has developed a new approach to TEM sample lift-out by using NanoEffector microgrippers to grasp the FIB-cut samples. This unique approach allows samples to be removed and placed onto a TEM grid inside either a scanning electron microscope (SEM) or an FIB system using, in-situ, the Zyvex Nanoprober. Figure 1 Zyvex Nanoprober probing Zyvex Nanoprober cutting samples Zyvex Nanoprober lift-out The new Zyvex NanoEffector microgripper-based method is favorable over traditional methods since samples can be removed and manipulated without being contaminated by FIB deposition. Background Zyvex has developed an automated assembly technology for microsystems which is scaleable to nanosystems manipulation and assembly. Much of this research and development has been done using electrothermal microelectromechanicial systems (MEMS)-based microgrippers to assemble many three-dimensional structured microsystems Figure 2 Zyvex Nanoprober System

(see Figure 3). MEMS grippers allow small, delicate objects to be maneuvered with nanometer-scale precision and accuracy. These grippers have other assembly applications, including TEM sample preparation. Zyvex NanoEffector Microgrippers (see Figure 4) are used for TEM sample lift-out. The grippers use electrothermal actuation to achieve a range of motion from zero to five microns of opening at the tips. An electrical potential is applied across the two anchor pads, passing current through the bent-beam structures. Joule heating within the beams results in localized thermal expansion. This thermal expansion drives flexures which amplify and create horizontal motion at the gripper tips. Pick Rotate Place Figure 3 (a-c) Zyvex technology using microgrippers In the MEMS fabrication process, there is a minimum spacing between the tips. Zyvex packages the NanoEffector Microgrippers onto an aluminum nitride sub-mount. The sub-mount, with microgrippers attached, is then mounted on the end of the Zyvex Nanoprober plug. This gives the microgrippers the ability to move in x, y, z, and to grasp the sample and lift it out. The range of motion of the Nanoprober is excellent for this task. Probe in-situ Lift-out Method The Zyvex System is capable of performing the standard method of in-situ TEM lift-out using Zyvex NanoEffector tungsten probes. After locating the area of interest, a sample is micromachined in the dbfib system. One of the four probes on the Nanoprober is then inserted into the area of interest. The probe is placed on top of the sample and then welded to the sample using FIB deposition. The tethers are cut to ensure the sample is entirely free. To lift out the sample and find the TEM grid, the Zyvex Nanoprober then moves up in z and over in x and y. The sample is then welded to the TEM grid for further thinning (if necessary). The steps to this process are shown in Figure 5. Figure 4 Power-open electrothermal grippers Normal welding techniques are not always reliable because the probe does not weld very securely to the sample using the platinum deposition. It is easy to break the platinum deposition if the sample is not completely free at all times while trying to move the probe. Even vibrations from the gas injector can cause the platinum to crack. It should be noted that this method requires some maintenance to the probe to keep it sharp. The tip must be

re-etched every time it becomes dull from the welding and cutting contamination process. This method also risks contaminating the sample. The Zyvex in-situ Lift-out Method Current methods of probe in-situ lift-out are cumbersome, time consuming, and may contaminate the sample in the process. Zyvex believes there is a better solution to this task. By eliminating the steps of welding and milling the probe to the sample, all of the limitations above can be surmounted. The Zyvex lift-out method uses NanoEffector Microgrippers powered by electrothermal actuators. These state-of-the-art microgrippers allow the sample to be easily grasped and manipulated freely without risking contamination. When Zyvex s microgrippers are powered, they open. When the power is turned off the microgrippers close around the sample in order to retrieve it from the FIB-cut trench. The gripping motion is achieved by thermal expansion and motion amplification which has been optimized to achieve appropriate deflection with sufficient force at the tips. Ideally, for efficient TEM lift-out, the samples are picked and placed in a serial automated fashion onto a carbonbacked TEM grid. This process would be useful for a very high efficiency design. If a higher quality of analysis is necessary, and efficiency is not as much of a concern, the samples could be welded onto the side of a TEM grid. With the Zyvex microgripper lift-out process, it is possible to retrieve FIB-cut samples of varying sizes since the microgrippers have a variable opening. (d) Another benefit of this new process is that the sample need not be completely cut free to lift it out. Our samples are undercut and are left with only one tether. The gripping force causes the tether to controllably break during lift-out. As shown in Figure 6, the grippers are aligned over the sample using the Nanoprober. The power is turned on to open the grippers above the sample. Then the grippers move down, inserting the gripper tips around the sample. The power is turned off and the sample is grasped as the tether is broken. The sample is securely grasped and is then removed from the trench. Figure 7 shows the lift-out sequence. Figure 5 (a-d) In-situ probe method for TEM lift-out

Figure 6 (a-c) Preparing to lift-out using MEMS grippers Figure 7 (a-c) Lifting out the sample with MEMS grippers

The final step is to locate the sample to the TEM grid by moving in x and y and rotating the stage. Then the sample is placed into the groove of the grid, and welded in place. It is also possible to set the sample down by opening the gripper to release it. You can also perform this process on a carbon backed grid. Figure 8 shows the sample placed onto the side of the grid as a demonstration of the ability to release the samples without stiction. Welding to the side of the grid is necessary for re-thinning the sample. The Zyvex microgripper lift-out process has many advantages over the standard probe lift-out method. It avoids many of the cutting and welding steps which shortens the process saving time. Contamination is also less likely to occur since the tool is not welded to the sample. Also the microgrippers can be re-used for hundreds to thousands of lift-outs without requiring maintenance to maintain their performance. The standard probe lift-out method requires re-sharpening in the FIB after each sample lift-out. The Zyvex Nanoprober, with better than 5 nm resolution and 4 degrees-of-freedom, makes manipulation controlled and smooth. Conclusions NanoEffector Microgrippers used with the Zyvex Nanoprober for TEM sample lift-out is a new approach that overcomes some of the current limitations of probe in-situ lift-out. It is capable of performing lift-out with two processes from four different orientations. The key advantages of the NanoEffector microgripper lift-out method are: faster lift-out times, less contamination, reliable process, reusable, no maintenance, and easy to use. Future developments for this application will implement automation to minimize user interaction and increase efficiency. Figure 8 (a-c) Placement of sample onto grid Copyright 2006. Zyvex Corporation. All rights reserved. Zyvex, the Zyvex logo, NanoWorks, and NanoEffector are registered trademarks of Zyvex Corporation. Document: TEMS-ZZAN-001d