XIAMEN MIBET NEW ENERGY CO., LTD. SOLAR PANEL SUPPORT FRAME ADJUSTABLE TRIPOD MOUNTING SYSTEM FOR CONCRETE AND METAL ROOF

Similar documents
Just Makes Cents... Per Watt. Compliance Report Composition L-Foot Kit State of California September 25th SOLARACK INC.

STRUCTURAL DESIGN CERTIFICATE No: CSM SC Job No: 14S 391

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

B-RAIL SPAN CHART REPORT

B-RAIL SPAN CHART REPORT

Ground Mounting System I Installation Manual

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

PV-ezRack SolarRoof Klip-Lok Interface

DPA Solar Racking Solutions Ground Mount Installation Guide V1.5

MRac Tile Roof Installation Guide

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads)

BOXSPAN RESIDENTIAL SPAN TABLES

MRac Trapezoidal Metal Roof Mounting System. Installation Guide

Radiant PV-Solar Tripod System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

Solar Panel Mounting Kits

MOUNTING SYSTEMS PRODUCT CATALOG

Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

STRUCTURAL REPORT. Magerack Series 101 PV Mounting System. 130 mph Wind, Exposure B & C. California DESIGNER OF RECORD

PV-ezRack SolarRoof Longline Interface

HelioFix Solar mounting Systems

National Construction Code Series (NCC 2012) Building Code of Australia (BCA)

Absco Garden Shed Products Snow Support Frame Model: SNOW3018

Chiko V Solar Ground Mount

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

Rack-in-a-BoxTM INSTALLATION MANUAL

Clean Energy Creating A Bright Future

mounting systems applications overview

Stone and Masonry Veneer

PER See all Pei ES Listings at: Report Owner (Fabricator) Vinyl By Design State Road 15 New Paris, IN 46553

Structural Design Documentation

TWO STOREY MASONRY VENEER DESIGN SOLUTION - FIRTH 10 SERIES HOLLOW MASONRY, MANORSTONE

SECTION STRUCTURE MOUNT RAILING SYSTEM

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing

MANUFACTURERS OF METAL BUILDING SYSTEMS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

The Racking System Designed By Installers for Installers

SECTION FACILITY LIGHTNING PROTECTION

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

PITCHED ROOF DESIGN GUIDE A WALKTHROUGH OF THE SOLAR MOUNTING DESIGN PROCESS

This Addendum forms part of the Tender Documents and amends the Tender Documents as described below.

Always be your solar support

Installation Manual Solar Mounting System (Flat Roof Tilted Solution)

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

GUIDELINES FOR SOLAR WATER HEATERS INSTALLATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

TRAPEZOIDAL SHEET METAL RAIL

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For POWER-STRUT Mounting System only

UL Design System HW-D-1012 continued

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

Test 1 Non Cyclonic Testing of 0.42mm BMT KlipLok Classic 700 (Lysaght) Roof Sheeting with 75mm Spacer and 100mm Insulation

SECTION COLD-FORMED METAL TRUSSES

Code Compliance Research Report CCRR-0238

LINTEL. Western Australia Lintel Span Tables. High Strength Steel and Now More Durable. Effective from December 2014

Light-Metal Roof Edge, Raised

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

POST FRAME BUILDING STANDARDS

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

Code Compliance Research Report CCRR-0238

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

New! Söll. Designed for light-weight industrial and commercial roof applications.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

ROOFING & SHEET METAL MANUFACTURERS

Uncovered Decks & Porches

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

DynoRaxx EVOLUTION PR Guide to Code Compliant Installation

SECTION PRE-ENGINEERED METAL BUILDING

TYPICAL ROOF CONDITION LAYOUT

******************************************************************************

Western Australia OZLintel Span Tables. High Strength Steel and Now More Durable.

PV-ezRack SolarTerrace III

ROOFING & SHEET METAL MANUFACTURERS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Building Integrated PV System (BIPV) Tile-in Roof PV Mounting System Integrated Roof Carport Façade PV Greenhouse

ETALLODOMI S.A. Head Office: 12, Kastorias str Athens GREECE. Main Warehouse: 49, Agiou Orous str. GREECE

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

At last! Construction bracing made easy...

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Solar Panel Installation in the NT

MK004 DOMESTIC. SLATE Roof 4 x panel requirement LS Roof tile fixing support

SECTION CLADDING SUPPORT SYSTEMS

SRP CEILING SYSTEMS HANDBOOK

SECTION EXTERIOR GRILLS AND SCREENS

Do not place bundles of deck so as to overload the supporting structure.

ST-AK 1/12. Photovoltaic Mounting Systems. Assembly Instructions. Mounting system for roofing with trapezoidal sheet metal

Conergy SolarFamulus II

The Finnish Quality Since 1960

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

HelioFix Solar mounting Systems

SECTION STAINLESS STEEL WALL PANELS

DynoRaxx EVOLUTION PR Quick Guide Installation Steps

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Structural Criteria for Residential Rooftop Solar Energy Installations

Transcription:

Project number: R119_03A Xiamen Mibet New Energy Co., Ltd. No. 69 Xintian Road Jimei District Xiamen China Attention : Cathy Xu. Dear Madam, RE: XIAMEN MIBET NEW ENERGY CO., LTD. SOLAR PANEL SUPPORT FRAME ADJUSTABLE TRIPOD MOUNTING SYSTEM FOR CONCRETE AND METAL ROOF As requested, we have reviewed the structural adequacy of the Aluminum support framing components as detailed in the drawings issued by Mibet (Xiamen) New Energy Co. Ltd. We have design investigated for the Aluminum Railing as shown below. The section of the railing is shown below. The panels are supported by two rows of railing. The railings are fixed directly to Adjustable Tripod Mounting System, where is anchored into reinforced concrete roof. The spacing of the tripods shall be limited as tabulated below in tables 1 and 2. Rail 45 Adjustable Tripod Mounting System anchor to concrete roof slab Two Rows Railing Rail 45 1650 X 990 or 1970X 990 Panel Portrait Mode tel: +61 (2) 9565-5558 fax: +61 (2) 9565-5606 info@spadengineer.com.au www.spadengineer.com.au Director: Paheer C Paheerathan BScEng, MEngSc, FIEAust, CPEng, NPER (Civil & Structural)

Terrain Category 2 (TC2) Open terrain, including grassland, with well-scattered obstructions having heights generally from 1.5 m to 5 m, with no more than two obstructions per hectare, e.g. farmland and cleared subdivisions with isolated trees and uncut grass. Table 1. 1650 Long Panel Inclination 20 to 30 degrees Maximum spacing of the fixing of the Back Legs (mm) Railing: Rail 45 Roof Height Region A Region B Region C Region D 5m 1510 1040 670 440 10m 1240 860 550 370 15m 1140 860 510 330 20m 1090 740 480 320 Table 2. 1970 Long Panel Inclination 20 to 30 degrees Maximum spacing of the fixing of the Back Legs (mm) Panel size: 1970 Long. Railing: Rail 45 Roof Height Region A Region B Region C Region D 5m 1420 980 630 410 10m 1170 810 520 340 15m 1070 810 480 310 20m 1030 700 450 300 Page 2 of 5

Our design investigation is based on the following Australian Standards and sections of Building Code of Australia relevant to structural issues. AS 1170.0-2002 Structural design Actions Part 0: General principles AS 1170.2-2002 Structural design Actions Part 2: Wind actions AS 1664.1-1997 Aluminum structures Part 1: Limit state design AS 4673-2001 Cold Formed Stainless Steel AS 1684.1-1999 Residential timber-framed construction - Design criteria AS 1684.2-2010 Residential timber-framed construction - Non-cyclonic areas AS 1684.3-2010 Residential timber-framed construction - Cyclonic areas AS 1720.1-2010 Timber structures - Design methods.pdf AS 3566.1-2002 Self-drilling screws for the building and construction industries AS 3566.2-2002 Part 2: Corrosion resistance requirements ISO 3506:1-2009 Mechanical Properties of Corrosion-Resistance Stainless Steel Fasteners Following design criteria has been used for the structural verification. Design Life Importance Level 25 years Annual Probability of exceedance 1/200 Terrain Category to AS1170.2 2 Service Deflection Snow loading Earthquake Loading Maximum Roof Pitch Aluminum Rails Maximum dimensions of Solar panels. Type 2: Ordinary Not limited Not considered Not considered 7 degrees 6005 - T5 16 Kg panel 1650X990 23 Kg panel 1970X990 Page 3 of 5

List of components related to this framing system are as tabulated below. Components Part Number Description End Clamp Kit MR-EC-ST Fastening parts Inter Clamp Kit MR-IC-ST Fastening parts C Clamp Kit MR-CC-T Fastening parts Adjustable Tripod MR-RM2-SPT Fixed on roofs Rail 45 MR-R-45 Rail L3100mm Splice for rail 45 MR-SP-45 Expanding rail length Seppan Clip MR-VI-11 Fixed on roofs Subject to the following qualifications we certify that the above mentioned frames are structurally adequate and conform to the above Australian standards. 1. Each row of 1650/1970 long solar panels shall have a minimum of two rows of railing to support the panels. The upper railing is supported with back legs (struts). The struts shall be directly fixed to the purlins. The lower railing shall be fixed to the roof purlins with shorter legs of with a use of a base bracket. 2. The connections between the solar panels shall be flexible to accommodate deflection of the railing. 3. The panel edge that is supported by the longer leg shall not be located within the edge zone, minimum of 0.2b, or 0.2d, or h, as defined in Clause 5.4.4 of AS1170.2. 4. The panel edge that is supported by the short leg shall have a clearance of 300 from the roof edge. 5. The deflection of the railing has not been controlled in the design. If defection has to be limited then spacing shall be reduced as advised by a practicing structural engineer. 6. The roofing to which the panels are to be installed shall conform to the relevant Australian Standards including AS4100 and AS3600. 7. The buildings to which the panels are to be installed shall be of approved construction and conform to BCA and the relevant Australian Standards. The roof framing and the building shall be regularly maintained as required. 8. The installation of the framing shall conform to relevant Australian Standards, Manufacturer s specifications and good building practice. Page 4 of 5

9. The spacing of the rail fixings shall not exceed the recommended spacing, and shall be reduced to match the location of the roof rafters. 10. The cantilever span of the panel shall not exceed 25% of panel length (ex 400mm for 1600 long). 11. The cantilever span of the railing shall not exceed 50% of the adjacent spacing of the installed fixings. 12. The panels shall not be located within the edge zone as per AS1170.2 13. Use 2M12 Chemset anchors or similar. The water proof membrane shall be reinstated. Use tungsten carbide bots for drilling. Slab reinforcement shall not be damaged. 14. For light framed roofing each fixing shall have a minimum 2 gauge 14 screws. 15. The screws used to attach the railing to the roof framing shall conform to AS3566, ISO 3506.1. 16. The cold formed steel purlins shall have a minimum base material thickness of 1.2mm in Regions A & B and 1.9mm in Regions C & D. 17. Timber with Joint Type classification J4 to J6 are excluded unless tested for Screw capacity. i.e. minimum joint strength requirement shall be J3. 18. Predrilled holes shall be used for all screw fixings into timber. The width of Timber purlins shall not be less than 35mm. The minimum embedment for each screw shall be 50mm. 19. Dissimilar metals shall be separated with a suitable inert material to prevent galvanic corrosion. 20. The installation and fixings shall be periodically inspected and maintained. 21. The following are excluded from this certification. x x Framing of the PV Cell. Verification of test certificates for the materials and components. Should you have any queries, please feel free to call Paheer on 9565-5558. Yours faithfully, SPAD PTY LTD Paheer C Paheerathan BScEng, MEngSc, FIEAust, CPEng, NPER (Civil & Structural) 142156; RPEQ-09066; NTBPB 216724ES Director Page 5 of 5