SECTION MECHANICALLY STABILIZED EARTH 1.01 SUMMARY

Similar documents
SECTION SPECIFICATION FOR MECHANICALLY STABILIZED EARTH TWO STAGE WALL SYSTEM

SECTION MECHANICALLY STABILIZED EARTHEN SLOPES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SPECIFICATION FOR GALVANIZED STEEL WIRE FORMED, STONE FILLED MECHANICALLY STABILIZED EARTH RETANING WALL

SPECIFICATION FOR SEGMENTAL RETAINING WALLS Mesa Retaining Wall System

SPECIFICATION FOR MAGNUMSTONE GEOGRID REINFORCED Mechanically Stabilized Earth (MSE) SYSTEM

MagnumStone Specifications Gravity

SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SAMPLE CONSTRUCTION AND MATERIAL SPECIFICATIONS FOR THE ULTRABLOCK GRAVITY WALL SYSTEM

INS T A LLA T I O N G U I D E

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

CITY OF FARGO SPECIFICATIONS GEOTEXTILES AND GEOGRIDS

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

Wmega Retaining Wall Specification

Section ( ) MODULAR CONCRETE RETAINING WALL

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

CONCRETE SEGMENTAL RETAINING WALLS

Section ( ) KEYSTONE CONCRETE RETAINING WALL

MODULAR CONCRETE RETAINING WALL

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

Section ( ) SPECIFICATION FOR SEGMENTAL CONCRETE UNIT RETAINING WALL

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012

TION GUIDE ALLA T INS

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Reinforced Soil Slopes (RSS)

1.03 Submittals A. Submit the following in accordance with Section 01300:

FLORIDA DEPARTMENT OF TRANSPORTATION

SECTION ASPHALT INTERLAYER REINFORCEMENT SYSTEM. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 867 TEMPORARY WIRE FACED MECHANICALLY STABILIZED EARTH WALL.

SECTION Segmental Concrete Unit Masonry Retaining Wall Height Over 5-0 High

Section Specification for Geogrid Base Reinforcement of Flexible Pavement Structures

Retaining Wall Systems

ROAD COMMISSION FOR OAKLAND COUNTY. SPECIAL PROVISION FOR GABION WALL RCOC/DESIGN: AB Page 1 of 8 RCOC12SP706F 10/28/2013

SECTION SEGMENTAL CONCRETE UNIT MASONRY RETAINING WALL MAXIMUM HEIGHT OF 5-0 HIGH

SECTION ( ) MODULAR CONCRETE RETAINING WALL SYSTEM WEATHERED MULTI SHAPE 8 (203mm) HIGH UNITS

Wall Modular Block Mechanically Stabilized Earth, Item S.

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

Michigan State University Construction Standards SEGMENTAL CONCRETE RETAINING WALLS PAGE SECTION SEGMENTAL CONCRETE RETAINING WALLS

Section (02830) MODULAR CONCRETE RETAINING WALL

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SEGMENTAL RETAINING WALL KEYSTONE / MEGA-CELTIK

SECTION ASPHALT CONCRETE

CYPRESS Stone Geogrid Reinforced Retaining Wall Installation Specification SECTION CONCRETE SEGMENTAL RETAINING WALL PART 1 GENERAL

Section (1997 Section 02795) PERMEABLE, FLEXIBLE and PLANTABLE CONCRETE EROSION CONTROL SYSTEM

GABIONS AND REVET MATTRESSES

SECTION SEGMENTAL RETAINING WALL

CONTENT. INTrOduCTION 3. units & CONNECTOrs 4. standard INsTallaTION PrOCEdurEs 5

67665_MesaInstallationGuide_2 12/10/07 2:12 PM Page 1 E ID U G TION ALLA T INS

Celtik Pro TM Wall Spec

Description. This work shall consist of furnishing materials and placement of modular block wall constructed in accordance with

Geosynthetic Materials for Separation and Stabilization

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

GEOGRID CONNECTION DETAIL OLYMPIA RADIUS UNIT

SPECIFICATION FOR REINFORCED SOIL WALL

Section Soil Erosion Protection Tender No. [ ] Page 1

SECTION 1208 CHAIN LINK FENCING DESCRIPTION

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION LIMESTONE SEGMENTAL RETAINING WALLS

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

LANDSCAPE RETAINING WALLS

1. Concrete pavers, with ungrouted joints, over sand base. a. Large precast sections in random mix with smaller concrete pavers

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM BIG BLOCK / WETCAST

SPECIFICATIONS FOR DRAINTUBE DRAINAGE GEOCOMPOSITES

ROLLED EROSION CONTROL PRODUCTS (RECP)

PRODUCT SPECIFICATION CSI FORMAT Earth Retention System April 2009

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

SIERRASCAPE RETAINING WALL SYSTEM. design and installation guide

02632 Segmental Concrete Retaining Wall System Page - 1

Gravity Wall. A force to be reckoned with... Gravity (SRW) segmental retaining wall systems are structures

INSTALLATION AND ENGINEERING MANUAL

A. Modular Unit - A concrete wall interlocking element, machine made from portland cement, water and aggregates.

KU Design Guidelines APPENDIX II PERMEABLE BITUMINOUS PAVEMENT

BIAXIAL GEOGRID REINFORCEMENT

TERRASTOP SYSTEM 2 RETAINING WALLS. Section Page 1 PART 1 - GENERAL 1.1 SUMMARY

SECTION EROSION CONTROLS

REINFORCED CONCRETE MASONRY SECTION

Uwall UNIVERSAL CONSTRUCTION MANUAL

GABIONS PVC Coated. Product Standard Specifications Installation Instructions Method of Measurement and Payment. Update: May 1999

QUALITY CONTROL PROGRAM OUTLINE

DRIVABLE GRASS GUIDELINE FOR NON PLANTED DRY INFILL INSTALLATIONS

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

CONSTRUCTION SPECIFICATION FOR STRUCTURAL WOOD SYSTEMS

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

2018 Intertape Polymer Group GEOSYNTHETIC RAIN COVER INSTALLATION GUIDE

Five Stone System. Trench Depth Compactible Rock. Foundation. 57 lbs 41 lbs 31 lbs 47 lbs. Patent Pending. Approximate Weight

C. Foundation stabilization for pipe and utility structures.

Transcription:

SECTION 028300 PART 1 GENERAL 1.01 SUMMARY A. Section includes Basis of Design Mechanically Stabilized Earth System: SierraScape Mechanically Stabilized Earth (MSE) retaining wall system having high density polyethylene or polypropylene geogrids positively connected to steel welded wire mesh facing units. B. Other approved, comparable systems will be considered and allowed. C. The MSE Stabilized Earth is a permanent below grade installation that is to prevent earth loads from being exerted on adjacent below grade walls and utilities. Refer to drawings. D. Related Sections 1. Section 31 10 00 Site Clearing and Demolition 2. Section 31 20 00 Earth Moving 1.02 REFERENCES for BASIS OF DESIGN MSE RETAINING WALL SYSTEM A. American Association of State Highway and Transportation Officials (AASHTO) 1. T289 Determining ph of Soil for Use in Corrosion Testing 2. M288 96 Standard Specification for Geotextiles 3. Standard Specification for Highway Bridges (2002 Interim) B. American Society for Testing and Materials (ASTM) 1. A123/A 123M 97 Standard Specification for Zinc Hot Dipped Galvanized Coating on Iron and Steel Products 2. A186 85 Standard Specification for Steel Welded Wire Fabric for Concrete Reinforcement 3. D698 98 Standard Test Method for Laboratory Compaction Characteristics of Soil Using Standard Effort 4. D1388 96 Standard Test Method for Stiffness of Fabrics, Option A 5. D4355 92 Standard Test Method for Deterioration of Geotextiles from Exposure to Ultraviolet Light and Water (Xenon Arc Type Apparatus) 6. D4595 94 Standard Test Method for Tensile Properties of Geotextiles by the Wide Width Strip Method 7. D4716 95 Test Method for Constant Head Hydraulic Transmissivity (In Plane Flow) of Geotextiles and Geotextile Related Products 8. D4759 92 Practice for Determining the Specification Conformance of Geosynthetics 9. D5262 97 Standard Test Method for Evaluating Unconfined Tensile Creep Behavior of Geosynthetics 10. D5818 95 Practice for Obtaining Samples of Geosynthetics from a Test Section for Assessment of Installation Damage 11. D6637 01 Standard Test Method for Determining Tensile Properties of Geogrids by the Single or Multi Rib Tensile Method 12. F904 91 Standard Test Method for Comparison of Bond Strength or Ply Adhesion of Similar Laminates Made from Flexible Materials C. Geosynthetic Research Institute (GRI) 4-14-17 Page 1 of 6 028300

1. GG1 87 Standard Test Method for Geogrid Rib Tensile Strength 2. GG2 87 Standard Test Method for Geogrid Junction Strength 3. GG5 91 Standard Method for Geogrid Pullout D. Tensar International, Inc. (TET) 1. Design Guidelines for Tensar Geogrid Reinforced Soil Walls with SierraScape Facing Units, TTN:SierraScape DG. 1.03 DEFINITIONS and REFERENCES for BASIS OF DESIGN MSE RETAINING WALL SYSTEM A. Ultimate Tensile Strength Breaking tensile strength when tested in accordance ASTM D6637 01 B. Junction Strength Breaking tensile strength of junctions when tested in accordance with GRI GG2 as modified by AASHTO Standard Specification for Highway Bridges, 2002 Interim, using a single rib having the greater of 3 junctions or 8 inches and tested at a strain rate of 10 percent per minute based on this gauge length. Values shown are minimum average roll values. C. Tensar Structural Geogrids A polymeric grid formed by a regular network of integrally connected tensile elements with apertures of sufficient size to allow interlocking with surrounding soil, rock or earth and function primarily as reinforcement. D. SierraScape Facing Units A 9.1 foot long by 3 to 3.5 foot wide steel welded wire mesh sheet that is bent 90 degrees at its long center line to form an L shaped unit. The vertical 18 inch high section provides a face that retains the fill. The horizontal 1.5 to 2 foot leg extends into the fill. Diagonal wire struts connect the top horizontal wire on the face to the parallel wire at the rear edge to increase the stiffness of the face and increase lateral support of the soil or stone fill. They are placed at the ends and at about 22 inch spacings along the facing unit. E. Sierrascape Connection The horizontal leg of the welded wire mesh facing form has an inverted U shaped loop bent into the transverse wires near its rear edge. The loops fit up through the apertures of the geogrid and bear against the cross machine bars of the geogrid. This forms a structural connection that transfers load between the facing unit and the geogrid. A connection rod is placed through the loops and over the geogrid ribs to secure the connection. F. Facing Fill Soil or stone fill placed immediately behind the vertical leg of the Facing Units if different than Reinforced Backfill. This can be planting soil, sand, small or large stone. G. Reinforced Backfill Compacted structural fill placed within the geogrid reinforced volume. H. Long Term Design Strength (LTDS or T al ) The maximum allowable stress level of the polymeric grid used in the internal stability design calculations of the retaining wall. Ultimate Tensile Strength reduced by the effects of installation damage and durability. I. Long Term Allowable Design Strength (T a ) The Long Term Design Strength (LTDS or T al ) reduced by the Factor of Safety for design uncertainties (T a = T al /FS UNC ).. 1.04 BASIS OF DESIGN SYSTEM DESCRIPTION A. Basis of Design Description: The SierraScape system is a MSE retaining wall that uses high density polyethylene or polypropylene Tensar Geogrids to reinforce soil fill. The wall facing units are welded wire mesh sheets that have been bent into an L as described in 1.03 D. The geogrid is connected to the facing units as described in 1.03 E. SierraScape can be constructed to provide a vertical or a stepped back, inclined face. It can be designed for temporary or permanent applications. B. The SierraScape MSE Wall System shall be designed by a Professional Engineer in accordance with the design guidelines of Tensar International, Inc. 1.05 SUBMITTALS A. Product Data Manufacturer's materials specifications, installation instructions, and general recommendations. 4-14-17 Page 2 of 6 028300

B. Certifications The SierraScape System supplier shall provide certification that the ultimate strength of the Tensar Structural Geogrid, per ASTM D6637 01, is equal to or greater than the ultimate strength specified on the Plans. C. Plans Engineering drawings, elevations, and large scale details of elevations, typical sections, details, and connections. D. Samples 1. Geogrid 4 in. by 16 in. piece 2. Facing Unit 12 in long section 3. Erosion Control Materials 4 in by 8 in pieces E. Quality Control Submittals 1. Design Data Design calculations and plans for the retaining wall system sealed by a Registered Professional Engineer. 2. Certificates Manufacturer's certification that the Ultimate Tensile Strength and the Junction Strength of the geogrid are equal to or greater than those specified. 1.06 QUALITY ASSURANCE A. Designer A Professional Engineer, registered in Washington State, who is employed by a firm that has designed at least 200,000 square feet of MSE retaining walls, and who can provide a certificate of Errors and Omissions insurance to the Engineer and/or Architect with a minimum value of $2,000,000 per occurrence and in the aggregate. B. Mock Ups 1. Prior to construction of retaining walls, erect a sample wall using materials shown and specified. Build mock up at the site, where directed, approximately 20 feet long by 4.5 feet high. This may be a part of the final wall construction if approved. 2. Do not start final construction until the Architect and/or Engineer approves the mock up. Retain mock up during construction as a standard for judging completed work. Do not alter or destroy mock up until work is completed. C. Pre Construction Conference Prior to erection of retaining walls, hold a meeting at the site with the retaining wall materials supplier, the retaining wall installer, and the Designer to review the retaining wall requirements. Notify the Owner, the Engineer and/or Architect at least 3 days in advance of the time of the meeting. 1.07 DELIVERY, STORAGE, AND HANDLING A. Storage and Protection 1. General a. Prevent excessive mud, wet concrete, epoxy, or other deleterious materials from coming in contact with and affixing to retaining wall materials. 2. Polymeric Materials a. Store at temperatures above 20 degrees F ( 29 degrees C). b. Rolled materials may be laid flat or stood on end. PART 2 BASIS OF DESIGN PRODUCTS 2.01 MANUFACTURERS A. The SierraScape Facing Units and connection hardware shall be produced by a manufacturer approved by The Tensar Corporation, Morrow, GA. Contact Gary Sander, PE, 360 981 0222, Poulsbo, WA 98370 B. Tensar Structural Geogrids shall be manufactured by The Tensar Corporation, Morrow, GA. C. Geotextiles and Drainage Composites shall be manufactured by North American Green Corp, N.C. 4-14-17 Page 3 of 6 028300

D. Substitutions Refer to Division 1 specifications. 2.02 MATERIALS A. Tensar Structural Geogrids To be selected based on design requirements. 1. UX MESA2 a. Ultimate Tensile Strength: 3700 lbs. per linear ft., minimum average roll value. b. Junction Strength: 3330 lbs. per linear ft. c. Ultimate Connection Strength: 1780 lbs. per linear ft., minimum average roll value. 2. UX MESA3 a. Ultimate Tensile Strength: 4720 lbs. per linear ft., minimum average roll value. b. Junction Strength: 4410 lbs. per linear ft. c. Ultimate Connection Strength: 2000 lbs. per linear ft., minimum average roll value. 3. UX MESA4 a. Ultimate Tensile Strength: 7550 lbs. per linear ft., minimum average roll value. b. Junction Strength: 6795 lbs. per linear ft. c. Ultimate Connection Strength: 3500 lbs. per linear ft., minimum average roll value. 4. UX MESA5 a. Ultimate Tensile Strength: 9850 lbs. per linear ft., minimum average roll value. b. Junction Strength: 8865 lbs. per linear ft. c. Ultimate Connection Strength: 4370 lbs. per linear ft., minimum average roll value. 5. UX MESA6 a. Tensile Strength: 12,000 lbs. per linear ft., minimum average roll value. b. Junction Strength: 10,530 lbs. per linear ft. c. Ultimate Connection Strength: 5000 lbs. per linear ft., minimum average roll value. B. SierraScape Facing Unit: 1. 1.78 in x 12 in (0.192 x 0.225 ) x 9.1 ft galvanized WWM Facing Form. C. Wire Support Struts: 1. 26.3 in (0.25 ) Wire Support Strut with 1.5 in hooks each end, galvanized. D. SierraScape Interlocking Struts 1. Approved connection strut fabricated of galvanized steel. 2.03 ACCESSORIES A. Drainage Composite 6 oz. per sq. yd. polypropylene non woven geotextile, AASHTO M288 96, Class 2, bonded to both sides of a polyethylene net structure, produced by Evergreen Technologies, Inc. or equal as approved by Tensar International, Inc. 1. Minimum Allowable Transmissivity Not less than 1.5 gal. per min. per ft. of width when tested in accordance with ASTM D4716 95 at a confirming pressure of 10,000 lbs. per sq. ft. 2. Minimum Allowable Peel Strength of Geotextile from the Polyethylene Net Not less than 250 gm. per in. of width when tested in accordance with ASTM F904 91. B. Geotextile 6 oz. per sq. yd. polypropylene non woven geotextile, AASHTO M288 96, Class 2, produced by Evergreen Technologies, Inc. or equal as approved by Tensar International, Inc. C. Erosion Control Blanket Lofty web of polyolefin fibers between two high strength, biaxially orientated nets and bound together by parallel stitching with polyolefin thread. All components shall be inert to chemicals normally encountered in a natural soil environment. The SierraScape System 4-14-17 Page 4 of 6 028300

designer must include a reinforced, polymeric, permanent erosion control blanket on all soil structures/slope facings adjacent to the retaining walls. 1. Tensile Strength Not less than 175 lb. ft. by 100 lb. ft. when a 2 inch strip is tested in accordance with ASTM D5035 95. 2. Durability Retain a minimum of 80 percent of tensile strength after 1,000 hours of ultraviolet exposure when tested in accordance with ASTM D4355 92. 2.04 BACKFILL MATERIALS A. Stone Fill Free draining, uniformly graded stone that may be placed immediately behind the face of the 1.78 in x 12 in SierraScape Facing Unit as set forth in the plans. 1. 100 percent passing a 4 in. sieve 2. 0 to 10 percent passing a 2 in. sieve C. Reinforced Backfill Granular fills with a ph range of 2 to 12 and graded as follows: 1. 100 to 75 percent passing a 2 in. sieve 2. 100 to 75 percent passing a 3/4 in. sieve 3. 100 to 20 percent passing a No. 4 sieve 4. 0 to 60 percent passing a No. 40 sieve 5. 0 to 35 percent passing a No. 200 sieve** PART 3 CONSTRUCTION 3.01 QUALIFICATION A. Contractor and site supervisor shall have proven qualified experience to complete the installation of the retaining wall system. 3.02 EXCAVATION A. The subgrade shall be excavated vertically to the plan elevation and horizontally to the designed geogrid lengths. B. Overexcavated or filled areas shall be well compacted and inspected by an Engineer. C. Excavated materials that are used for backfilling the reinforcement zone shall be protected from the weather. 3.03 FOUNDATION PREPARATION A. Foundation trench shall be excavated to the dimensions indicated on the construction drawings. B. The foundation area shall be examined by an Engineer to ensure proper bearing strength. C. Soils not meeting required strength shall be removed and replaced with the proper materials as approved by the Engineer. D. Foundation materials shall be compacted to a minimum of 95 percent Standard Proctor Dry Density in accordance with ASTM D698 98. 3.04 BASIS OF DESIGN FACING UNIT INSTALLATION A. The first course of SeirraScape Facing Units shall be placed with the leg of the form having the geogrid connection loops placed on the foundation material. B. The first row of Facing Units shall be level from end to end and from front to back. C. The ends of the front faces of adjacent Facing Units shall be butted end to end. The vertical wires of adjacent facing units may be tied together as required to maintain alignment and prevent escape of backfill material. 4-14-17 Page 5 of 6 028300

D. A string line or equivalent shall be used to align straight sections of the structure. E. Place six wire Support Struts on approximately 22 inch centers connecting the upper horizontal wire of the face of the form to the back wire behind the connection loop after placement of geogrid as described in 3.05. Two of the Support Struts shall be located in the apertures of the facing units. F. Subsequent courses of Facing Units shall be placed on previous courses at a setback, if any, as shown on plans. H. Subsequent courses of Facing Units shall be aligned using a string line or other suitable method that is independent of the final position of the underlying course of Facing Forms. 3.05 BASIS OF DESIGN GEOGRID REINFORCEMENT INSTALLATION A. Unroll the geogrid and cut it to the length shown on the plans minus the distance between the front face and the front of the connection loop of the Facing Form, approximately 15 inches. The Geogrid shall be cut at the far end of the last aperture along the front side of the cross machine direction, (CMD), bar. B. 1. Place the Geogrid over the connection loops of the 1.78 in x 12 in Facing Units such that the loops extend up through every other aperture of the geogrid. Pull the geogrid back such that the CMD bar is in contact with the connection loops. Use two full widths of Geogrid per Facing Unit. 2. Where the CMD bar cannot engage the wire connection loop due to misalignment of apertures and wire loops, the CMD bar shall be cut midway between the wire loops to allow the geogrid to be spread or overlapped slightly to achieve correct alignment of grid apertures with connection loops. C. Thread the connection rods through the wire connection loops over the geogrid ribs. 3.07 BACKFILL A. Face Fill 1. Place Stone face fill over the horizontal leg of the 1.78 in x 12 in Facing Unit to the dimensions shown on plans and cover with geotextile separator. Compacted lift thickness shall be no greater than 9 inches or 2. Place the geotextile inside the Facing Unit and place the Reinforced Backfill as shown on plans. Compacted lift thickness shall be no greater than 9 inches. B. Pull the connection tight and place reinforced backfill or facing fill over the connection to secure it prior to placement of Reinforced Fill over the rest of the Geogrid. C. The Reinforced Backfill material shall be placed in maximum compacted lifts of 9 inches and shall be compacted to a minimum of 95 percent Standard Proctor Dry Density in accordance with ASTM D698 98. D. Only hand operated compaction equipment shall be used within 3 feet of the front face. E. Soil density testing shall not be performed within 3 feet of the front face. F. The backfill shall be smooth and level so that the geogrid lays flat. END OF SECTION 4-14-17 Page 6 of 6 028300