Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

Similar documents
MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

OVERALL STRUCTURAL SYSTEM

TECHNICAL REPORT 1. Structural Concepts / Structural Existing Conditions. Penn State Hershey Medical Center Children s Hospital. Hershey, Pennsylvania

William W. Wilkins Professional Building Columbus, Ohio

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

[TECHNICAL REPORT 3] Lateral System Analysis

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Project. San Jose City College Physical Education Building. Prepared For. Prepared By PLACE IMAGE HERE. Ken Bauer, AIA Principal

Hilton Baltimore Convention Center Hotel Western Podium

181 Fremont San Francisco, CA. Tech Report 3 10/17/2014. PSUAE Structural Option Advisor: Dr. Thomas Boothby

Crossroads at Westfields Building II

David A. Walenga Technical Assignment #1

Table of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5

Thesis Proposal. La Jolla Commons Phase II Office Tower San Diego, California. December 13, 2013

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Temecula Medical Center Temecula, CA

Southwest Housing, Arizona State University

Letter of Transmittal

90% Design Submittal Structural Calculations Parking Garage CDRL

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Pro-Con Structural Study for Alternative Floor Systems October 27, 2004

Technical Report #2. Matthew R Peyton

1000 CONTINENTAL SQUARE

Dead Loads (psf): Concrete Floor Slab on Metal Deck 45 psf Mechanical and Ceiling 7 psf Miscellaneous 5 psf Exterior Wall 80 psf

Franklin Square Hospital Center Patient Tower

STRUCTURAL TECHNICAL REPORT 1

Technical Report #1. Matthew R Peyton

CORPORATE HEADQUARTERS

Kaleida Health Global Heart and Vascular Institute University at Buffalo CTRC/Incubator. Buffalo, New York. Technical Report #2

HIGH RISE CONDO SOHO, NEW YORK, NY

Simplified Building Schematic for Typical Floor (Levels 9 through 22):

Technical Report 1. Seneca Allegany Casino Hotel Addition. Salamanca, NY

Jonathan R. Torch Technical Report 2 Columbia University. Technical Report 2. Pro-Con Structural Study of Alternate Floor Systems

Lateral System Analysis and Confirmation Design

Technical Report #3. Matthew R Peyton

Xyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan

Hilton Baltimore Convention Center Hotel Western Podium

Johns Hopkins Graduate Student Housing. Thesis Proposal. 929 North Wolfe Street Baltimore, Maryland Brad Oliver Structural Advisor: Professor Memari

1000 CONNECTICUT AVENUE

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

Belmont Executive Center; Building A

Traci Peterson Option: Structural Faculty Consultant: Memari. Executive Summary

John Jay College Expansion Project

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

Technical Report #1. Indiana Regional Medical Center Indiana, PA. Cody A. Scheller. Structural Concepts & Existing Conditions Report

The Harry and Jeanette Weinberg Center Mercy Hospital Medical Office Building Baltimore, MD. Thesis Proposal

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Technical Report 1. Kingstowne Section 36A 5680 King Center Drive Kingstowne, VA James Chavanic. Structural Option. Advisor: Dr.

Structural Technical Report 1 Structural Concepts/ Structural Existing Conditions Report

Structural Technical Report 1 Structural Concepts / Existing Conditions

Christopher McCune Structural Option 2006 Senior Thesis Penn State Architectural Engineering. Eight Tower Bridge Conshohocken, Pennsylvania

Rutgers University Law School Building Addition and Renovation Camden, NJ

Technical Assignment 3 December 3, 2007

Structural Inspection

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Executive Summary Building Description: Introduction... 13

Structural Engineering, Mechanics, and Materials. Preliminary Exam - Structural Design

Structural Redesign Gravity System

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

Structural Technical Report I October 5, 2006 Structural Concepts / Structural Existing Conditions Report

Caitlin Ferrell Structural Option Dr. Boothby, AE Faculty Consultant. Erie Convention Center and Sheraton Hotel

CORPORATE HEADQUARTERS

FINAL REPORT. Structural Redesign of Hershey Medical Center Children s Hospital. Penn State Hershey Medical Center Children s Hospital

Executive Summary...2 Introduction...3 Structural System Overview Buffalo,...4 Foundation...4 Floor System...4 Gravity System...4 Lateral System...

Erie on the Park. Timothy Moore Penn State University Architectural Engineering Structural Emphasis Advisor: Prof. Ali Memari

GEN*NY*SIS CENTER FOR EXCELLENCE IN CANCER GENOMICS Rensselaer, NY

TECHNICAL REPORT III LATERAL STRUCTURAL SYSTEM ANALYSIS

Thesis Proposal. Piez Hall Extension. Oswego, NY

THE FORENSIC MEDICAL CENTER

UNION STATION EXPANSION AND RESTORATION

UNION STATION EXPANSION AND RESTORATION TECHNICAL REPORT I

Trump Taj Mahal Hotel

Visteon Village Corporate Center

ENTRY FORM. DVASE 2014 Excellence in Structural Engineering Awards Program

181 Fremont San Francisco, CA. Tech Report 1 9/12/2014. Caroline Klatman Structural Option Advisor: Dr. Thomas Boothby

Hershey Research Park Building One. Technical Report 2. Jonathan Krepps Structural Option Advisor: Dr. Hanagan 10/12/12

Technical Report #3: Lateral System Analysis. Executive Summary

STATEMENT OF SPECIAL INSPECTION FORM

Best Buy Corporate Building D (4) Richfield, MN

SEISMIC DESIGN GUIDELINES

Thesis Proposal. University Hospitals Case Medical Center Cancer Hospital. Daniel C. Myers. December 12, 2009

Park Potomac Office Building E

Earth and Engineering Sciences Building University Park, Pennsylvania

HARVEY MUDD COLLEGE TEACHING AND LEARNING CENTER SECTION Page 1 of 6 VOIDED CONCRETE SLAB

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

STRUCTURAL CALCULATIONS SEISMIC EVALUATION PEER REVIEW

Building Division Informational Handout

Kevin Wigton Structural Option. Technical Report III. Simmons College School of Management, Boston, Ma

Office Building-G. Thesis Proposal. Carl Hubben. Structural Option. Advisor: Dr. Ali Memari

Thesis Proposal. Office Building. Sayre, PA. Faculty Advisor: Dr. Thomas E. Boothby Revised: January 9, 2013

111 MORGAN ST. Ryan Friis

Lintel Tables Design Notes and Limitations

Thesis Proposal. Office Building. Sayre, PA. Faculty Advisor: Dr. Thomas E. Boothby Revised: April 1, 2013

Point Pleasant Apartments Point Pleasant, NJ Ryan P. Flynn Structural Option Faculty Consultant: Dr. Hanagan

Simplified Building Schematic for Typical Floor (Levels 9 through 22):

Statement of Special Inspections 2013 CBC

Transcription:

120 Montgomery Street, Suite 1410 San Francisco, California 94104 415/781-1505 Fax 415/781-2718 sde@sdesf.com Rajendra Sahai, SE Principal John W. Laws, SE Principal Steven Lepisto, SE Principal STRUCTURAL DESIGN CRITERIA (DRAFT-3) DATE: July 28, 2011 PROJECT: ARCHITECT: California Alumni Association University of California Berkeley, California Knapp VerPlanck Preservation Architects 235 Montgomery Street, Suite 747 San Francisco, CA 94104-2918 I. GENERAL CONDITIONS FOR DESIGN A. Existing Site Conditions 1. Geotechnical Report: (TBD) 2. Relatively flat site with various thicknesses of fill over Bay Mud (TBD) 3. Existing liquefaction potential (TBD) 4. Significant long-term and seismic-induced settlement (TBD) 5. Groundwater Elevation: (TBD) B. Existing Foundations 1. Existing Foundations for the East Wing and the Lobby is spread footings, and the ground floor slab is 4 inch thick concrete reinforced with 6X6-#10/10 welded wire fabric. The Lobby foundation is also spread footing with a crawl space, however the Lobby foundation is integral with the West (Office) Wing, which is scheduled to be demolished and which is on drilled pier foundation and is once story lower. The east basement wall of the office wing retains lobby structure foundation and the soils up to the grade that leads to the entry and needs to be retained. Thus this needs to be retained and integrated with the new West Wing structure. 2. The existing foundation of the West Wing consist of 18 inch diameter drilled piers with the bell bottom, bearing diameter of 3-6 interconnected at the basement slab level with tie beams 6 inches wide and 8 inches of depth integrated with the 4 inch concrete slab reinforced with welded wire mesh. 3. Demolishing of the West Wing will leave the existing east side basement and retaining wall unsupported at the top and will deflect laterally due to the soil pressures. Therefore, this wall will need to be shored by installation of temporary braces and a whaler at the top and for which the existing piers may be used for

Page 2 of 8 foundation of the temporary braces if the contractor s engineer finds it of usefulness. 4. The existing foundations in both the East Wing and the Lobby are spread continuous footings. In the East Wing these support the concrete end reinforced concrete shear walls in the N-S direction and the center bearing and shear wall in the E-W direction. The columns on the north and south sides are supported on continuous concrete footings that run the whole length of the building. In the Lobby, the exterior walls are supported on stem walls which in turn are supported on continuous reinforced concrete footings, and a center continuous footing under the crawl space columns. C. Existing Ground Floor Slab 1. Nominal 4 inches thick concrete slab on grade in the East Wing with 6x6-10/10 WWF reinforcing. Entry Lobby is supported 4 inch thick reinforced concrete slab and spanning from exterior stem wall and footing to a beam at the center spanning in the E-W direction to 10 inch square reinforced concrete column supported on a continuous footing five fee below the ground floor slab to provide a crawl space. The crawl space has 6 inch thick reinforced concrete slab which slopes up to the exterior wall footing. Concrete strength is unknown. (TBD) D. Roof Framing Systems 1. Both the East Wing and Lobby are framed using steel framing systems, employing pipe columns, steel girders, and 10 inches deep open web steel bar joists, which in turn support the roof Steel-Tex lath, and 2 inches a to 2 to 3 inches varying thickness light weight concrete fill. The strengths of the concrete and unit weight of the concrete are unknown. (TBD) 2. Mechanical Mezzanine: In the East wing there is approximately 500 square feet mezzanine supported in wood stud walls and framed using 6 inch deep light gage metal joists and two layers of ¾ inch thick tongue & groove wood decking. Lateral force resistance to the seismic forces for the mechanical mezzanine is provided by the lath and plaster wood stud walls of the corridor, powder room, and toilets on the floor directly below the mezzanine. These are not qualified lateral force resisting systems for new building under the current code. (TBD) E. Exterior Wall Construction and Support 1. Glass Curtain Wall: mullions supported at edge of slab F. Lateral Load Resisting Systems 1. East Wing i. Load bearing exterior reinforced concrete shear walls in the N-S direction and one interior reinforced concrete shear wall in the E-W direction. Concrete strength is unknown. (TBD)

Page 3 of 8 ii. Roof diaphragm is 2-1/2 inches thick vermiculite concrete with very light reinforcing (STEELTEX - an old product used in 1950s, with light gage steel mesh and heavy paper that spans 24 inches to the open web joists and provides formwork and reinforcing for the vermiculite concrete deck (unit weight generally of 20 to 35 PCF with 28 day compressive strengths in 100 PSI to 275 PSI range) attached to the walls with wall dowels into the slab. The adequacy of attachment of concrete deck to open web steel joists is unknown. (TBD) Vermiculite concrete strength is unknown as well as the STEELTEX as a reinforcement in concrete is an unknown. (TBD) 2. Lobby Building i. The bolted connection between the pipe columns and the steel W8 girder and its relatively rigid connection with the slab and foundation wall in the N-S direction provides for a moment frame not conforming to current standards in the code and is not a qualified system. In the E-W direction the columns act as cantilevered columns in the inverted pendulum system. This is not a qualified lateral system in the current code of standards. ii. Roof diaphragm for this lobby structure is vermiculite concrete varying in thickness from 2 inch to 3 inches with STEELTEX lath and paper as formwork and light reinforcing. The attachment of the deck concrete to the open web steel joists is unknown. (TBD) All three structures, West Wing, Lobby and East Wing that together constitute Alumni House presently, i.e., as of 2009 are rated as Good in the University of California s four category rating system (Good, Fair, Poor & Very Poor). 3. Replacement West Wing Building design Criteria a. Local Building Code i. 2010 California Building Code ii. Foundations: Drilled reinforced concrete piers and grade beams iii. Gravity floor and roof framing system: Steel framed construction with composite metal deck and concrete floors and roof. iv. Lateral Load resisting Systems: All qualified systems appropriate to the design may be used per ASCE 7-05 Table 12.14-1 in the following list: B.1, B.2, B.3, B.5, B.14, B.15, B.25, B.26 or B.27. b. Referenced Codes and Standards

Page 4 of 8 i. ACI 318-05, Building Code Requirements for Structural Concrete ii. American Institute of Steel Construction (AISC) 1. AISC 360-05, Specification for Structural Steel Buildings 2. AISC 341-05, Seismic Provisions for Structural Steel Buildings 3. AISC 358-05, Pre-qualified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications 4. Steel Guide Series 11, Floor Vibration Due to Human Activities iii. ASCE 7-05, Minimum Loads for Buildings and Other Structures iii. LOAD CRITERIA AND DESIGN LOADS a. Dead and Live Loads i. All Loads as per code requirements ii. M/E/P shafts: design for slab to be removed in future; apply slab dead load and live load; model as noncomposite deck iii. Stairs: Apply line load around stair opening for tributary dead and live load of stairs; assume stair may span either direction b. Seismic Loads and Parameters i. Seismic Mass for calculations by hand or computer modeling: 1. Uniform dead loads and self-weight: uniform masses applied at each level 2. Exterior walls: line masses applied at each level 3. Equipment: Assumed equipment weights plus concrete pads applied as uniform masses at specific areas 4. Penthouses: dead loads and self-weights applied at roof level as uniform masses at specific areas 5. Soil pressures and retaining wall masses if part of the lateral load resisting system.

Page 5 of 8 ii. Code Parameters 1. S ds = 1.318 seconds 2. S 1 = 0.512 seconds 3. Distance to Seismic Fault = 0.5 km 4. Dynamic linear elastic response spectrum analysis procedure; if applicable, Code spectrum (2010 CBC) c. Wind Loads and Parameters i. Basic wind speed, V = 85 mph (TBC) ii. Importance factor, I w = 1.0 iii. Exposure = B iv. Mean Roof Height = (TBD) v. Mean Parapet/Roof Screen Height = (TBD) vi. Method 2; projected area method vii. Lateral Earth Pressure: As per geotechnical Report (TBD) d. Elevator Loads: traction elevator (TBD) i. Machine beam reactions Total loads (including impact) ii. Guide rail support reactions Tube columns designed for seismic loads with ¼ deflection limit iii. Pit buffer reaction To be designed for pit reactions e. Window Washing System: (TBD) f. Load Combinations: CBC 2010 Chapter 2. iv. DETAILED DESIGN CRITERIA a. Concrete Strength: Minimum 3,000 PSI at 28 days b. Reinforcing steel: ASTM A615 and ASTM A706 Deformed and Plain Reinforcing bars. c. Sustainable : i. Recycled Aggregate for Concrete: ii. Cement Substitution: d. Analysis and Methods i. Gravity Load Analysis and 1. Concrete Slab and Grade Beams: Computer standard software or manual calculations. 2. Post-tensioned Two Way Concrete Slab: Standard Computer software. Balance a

Page 6 of 8 maximum of 80% of concrete slab weight by post tensioning. 3. Concrete Columns: Manual or standard computer software. e. Lateral Load Systems & Analysis and Option - A 1. Use Concrete Shear Wall for Lateral Load Resistance 2. Use concrete slabs for diaphragms and collectors. 3. ETABS or SAP or RISA computer software a. Fixed base model b. Dynamic linear elastic response spectrum analysis 4. Spreadsheets and manual calculations ii. Deflection Limits 1. Interior Slabs, Beams and Girders: Live Load deflections = Span/360; 2. Framing Supporting Exterior Walls: Live Load = Span/360; Maximum = One-Half (½) inches; Total load Deflection = Span/240, Maximum One (1) inch. iii. Columns 1. Standard Computer Software verified by manual calculations 2. Skip live load around columns 3. Deformation Compatibility: manual calculation; seismic moment equal to the axial load times the story drift is to be added to the controlling load case from computer modeling; iv. Reference geotechnical report: Geotechnical Investigation, Alumni House, California, by -------- ------------------(TBD) f. Lateral Load Systems & Analysis and Option - B 1. Concrete Slab and Grade Beams: Computer standard software or manual calculations. 2. Composite metal deck and concrete on steel beams and girders floor system.

Page 7 of 8 3. Steel braced frame: Either (a) Special steel concentrically braced frames, (b) Steel eccentrically braced frame, (c) Buckling restrained braced frames, or (d) Special steel moment frames ii. Composite Flooring Framing 1. LRFD design by RAMSTEEL or other standard software or manual calculations 2. Assume Un-shored Deck 3. Construction LL = 20 PSF 4. Camber: 80% of Construction DL; ¾ minimum; ¼ increments 5. Floor Vibration: Human comfort for vibrations due to human activities based on ASIC Guide Series 11; by RAMSTEEL or similar standard software iii. Deflection Limits 1. Interior Beams and Girders: post-composite LL = L/360; post-composite superimposed load = ¾ ; net total load = L/240 2. Framing Supporting Exterior Walls: postcomposite LL = L/360; post-composite superimposed load = ½ ; net total load = L/240 iv. Columns 1. Standard Computer Software verified by manual calculations 2. Skip live load around columns 3. Deformation Compatibility: manual calculation; seismic moment equal to the axial load times the story drift is to be added to the controlling load case from computer modeling; g. Buckling Restrained Braced Frames (BRBF) if used i. AISC 341-05, Seismic Provisions for Structural Steel Buildings ii. Buckling restrained braces placed in chevron configuration

Page 8 of 8 h. Steel Special Moment Resisting Frames (SMRF) i. AISC 341-05, Seismic Provisions for Structural Steel Buildings ii. AISC 358-05, Pre-qualified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications End of Document